Milwaukee Tool 6815 User Manual [en, es, fr]

Cat. No.
No de cat.
6805 6815
OPERATOR'S MANUAL MANUEL de L'UTILISATEUR MANUAL del OPERADOR
16 GAUGE SHEAR/ 14 GAUGE SHEAR CISAILLE DE CALIBRE 16/ CISAILLE DE CALBIRE 14 CIZALLA CALIBRE 16/CIZALLA CALIBRE 14
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL MANUAL DEL OPERADOR.
GENERAL POWER TOOL SAFETY WARNINGS
WARNING READ ALL SAFETY WARNINGS AND ALL INSTRUCTIONS. Failure
to follow the warnings and instructions may result in electric shock, fi re and/or serious injury. Save all warnings and instructions for future reference. The term "power tool" in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.
• Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
• Do not operate power tools in explosive at­mospheres, such as in the presence of fl am- mable liquids, gases or dust. Power tools create
sparks which may ignite the dust or fumes.
• Keep children and bystanders away while operating a power tool. Distractions can cause
you to lose control.
ELECTRICAL SAFETY
WORK AREA SAFETY
• Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Unmodi ed plugs and matching outlets will
reduce risk of electric shock.
• Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
• Do not expose power tools to rain or wet con­ditions. Water entering a power tool will increase
the risk of electric shock.
• Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords
increase the risk of electric shock.
• When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use
of a cord suitable for outdoor use reduces the risk of electric shock.
• If operating a power tool in a damp location is unavoidable, use a residual current device (RCD) protected supply. Use of an RCD reduces
the risk of electric shock.
PERSONAL SAFETY
• Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use a power tool while you are tired or under the infl uence of drugs, alcohol or medication. A
moment of inattention while operating power tools may result in serious personal injury.
• Use personal protective equipment. Always wear eye protection. Protective equipment such
as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries.
• Prevent unintentional starting. Ensure the switch is in the off-position before connecting to power source and/or battery pack, picking up or carrying the tool. Carrying power tools with
your fi nger on the switch or energising power tools that have the switch on invites accidents.
• Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left
attached to a rotating part of the power tool may result in personal injury.
• Do not overreach. Keep proper footing and
balance at all times. This enables better control
of the power tool in unexpected situations.
• Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewel- lery or long hair can be caught in moving parts.
• If devices are provided for the connection of dust extraction and collection facilities, ensure these are connected and properly used. Use of
dust collection can reduce dust-related hazards.
POWER TOOL USE AND CARE
• Do not force the power tool. Use the correct power tool for your application. The correct
power tool will do the job better and safer at the rate for which it was designed.
• Do not use the power tool if the switch does not turn it on and off. Any power tool that cannot be
controlled with the switch is dangerous and must be repaired.
• Disconnect the plug from the power source and/or the battery pack from the power tool before making any adjustments, changing accessories, or storing power tools. Such
preventive safety measures reduce the risk of starting the power tool accidentally.
• Store idle power tools out of the reach of chil­dren and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool. Power tools are dangerous in the
hands of untrained users.
• Maintain power tools. Check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the power tool’s operation. If damaged, have the power tool repaired before use. Many accidents
are caused by poorly maintained power tools.
• Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control.
• Use the power tool, accessories and tool bits etc., in accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the power tool
for operations different from those intended could result in a hazardous situation.
SERVICE
• Have your power tool serviced by a qualifi ed repair person using only identical replacement parts. This will ensure that the safety of the power
tool is maintained.
2
SPECIFIC SAFETY RULES
• Hold tools by insulated gripping surfaces when performing an operation where the cutting tool may contact hidden wiring or its own cord.
Contact with a “live” wire will make exposed metal parts of the tool “live” and shock the operator.
• Maintain labels and nameplates. These carry important information. If unreadable or missing, contact a MILWAUKEE service facility for a free replacement.
• WARNING: Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth defects or other reproductive harm.
Some examples of these chemicals are:
• lead from lead-based paint
• crystalline silica from bricks and cement and other masonry products, and
• arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending
on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to fi lter out microscopic particles.
SPECIFICATIONS
Capacity Minimum Radius
Cat. No. Steel Stainless
6805 1.5 mm (16 GA) 1.2 mm (18 GA) 120 4000 1/2" 1" 6815 1.9 mm (14 GA) 1.5 mm (16 GA) 120 4000 3/4" 1"
FUNCTIONAL DESCRIPTION
1
2
11
4
10
5
9
8
1. Motor housing
2. Power cord
3. Toggle switch (not shown)
4. Guard
5. Locking nut
6. Blade positioning screw
7. Lower blade clamping screw (not shown)
8. Lower blade
9. Upper blade
10. Yoke
11. Gear case
7
6
3
Volts
AC/DC RPM Left Right
SYMBOLOGY
Double Insulated
Volts Alternating Current/
Direct Current Amps
SPM
3
Strokes per Minute Underwriters Laboratories, Inc.,
United States and Canada
GROUNDING
WARNING Improperly connecting the
grounding wire can result in the risk of elec­tric shock. Check with a qualifi ed electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the cord or plug is damaged. If damaged, have it repaired by a MILWAUKEE service facility before use. If the plug will not t the outlet, have a proper outlet installed by a qualifi ed electrician.
Grounded Tools: Tools with Three Prong Plugs
Tools marked “Grounding Required” have a three wire cord and three prong grounding plug. The plug must be connected to a properly grounded outlet (See Figure A). If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of electric shock. The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool's grounding system and must never be attached to an electrically “live” terminal. Your tool must be plugged into an appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in Figure A.
Double Insulated Tools: Tools with Two Prong Plugs
Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfi es OSHA requirements and complies with the applicable standards of Underwrit­ers Laboratories, Inc., the Cana­dian Standard Association and the National Electrical Code. Double Insulated tools may be used in ei­ther of the 120 volt outlets shown in Figures B and C.
Fig. A
Fig. B
Fig. C
Grounded tools require a three wire extension cord. Double insulated tools can use either a two or three wire extension cord. As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage. Refer to the table shown to determine the required minimum wire size. The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. When using more than one extension cord to make up the total length, be sure each cord contains at least the minimum wire size required. If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum wire size.
Guidelines for Using Extension Cords
• If you are using an extension cord outdoors, be sure it is marked with the suffi x “W-A” (“W” in Cana- da) to indicate that it is acceptable for outdoor use.
• Be sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualifi ed person before using it.
• Protect your extension cords from sharp objects, excessive heat and damp or wet areas.
Recommended Minimum Wire Gauge
For Extension Cords*
Nameplate
Amperes
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 16.0
16.1 - 20.0
* Based on limiting the line voltage drop to fi ve volts at
150% of the rated amperes.
Extension Cord Length
25' 50' 75' 100' 150'
18
18
18
18 18 18 18 16 14 12
18 18 16 14 12 10
18 16 14 12 10
--
16
14
12
10
16 14 12 12
--
--
--
--
--
READ AND SAVE ALL
INSTRUCTIONS FOR FUTURE USE.
EXTENSION CORDS
OPERATION
WARNING To reduce the risk of injury ,
always unplug tool before attaching or remov­ing accessories or making adjustments. Use only specifi cally recommended accessories. Others may be hazardous.
WARNING To reduce the risk of injury ,
wear safety goggles or glasses with side shields.
In all cutting operations, keep the shear at right angles to the surface of the workpiece and the back as low as possible for fast cutting. Use an even forward pressure to insure effi cient operation. To obtain the least amount of metal distortion and smoothest edge, keep waste portion of metal to the right of the shear. Cutting line should be lubricated before cutting 16 gauge steel or heavier.
Blade Clearance
The clearance between the blades is not set at the time of manufacture. Cleaner edges and longer blade life will result when the gap is properly set for the gauge of the metal to be cut. Use 20% of the material thickness for an approximate blade clear­ance setting. Make minor adjustments, if necessary.
Fig. 1
Blade clearance
To adjust the gap:
1. Unplug the tool and loosen the lower blade clampling screw 1/3 of a turn with the socket wrench provided.
2. Turn the blade positioning screw, on the side of the yoke, in or out to decrease or increase the gap.
NOTE: If lowerblade clamping screw is loose
more than a 1/3 of a turn, the blade clearwance may be misadjusted.
3. Measure the clearance with the feeler gauge provided.
4. When the desired setting has been achieved, tighten the blade clamping screw and locking nut on the blade positioning screw.
Locking nut
Blade
positioning
screw
Lower blade
clamping screw
Steel
gauge
14 16 18 20 22 24
Decimel
equiv.
0.075" (1.9 mm)
0.060" (1.5 mm)
0.050" (1.3 mm)
0.036" (0.9 mm)
0.030" (0.8 mm)
0.024" (0.6 mm)
Feeler
gauge*
0.016" (0.40 mm)
0.012" (0.30 mm)
0.010" (0.25 mm)
0.008" (0.30 mm)
0.006" (0.15 mm)
0.004" (0.10 mm)
* Make minor adjustments if necessary.
Sharpening Blades
The cutting angles must be maintained. When blade replacement is necessary always replace the blades in sets. This will produce cuts of con­sistent quality.
Fig. 2
Upper Blade
Grind away from edge in sharpening for best cutting edge.
Cat. No. 6805 X° equals 15° Cat. No. 6815 X° equals 20°
Fig. 3
Lower Blade
Surface grind
4
5
MAINTENANCE
WARNING To reduce the risk of
injury, always unplug your tool before performing any maintenance. Never disas­semble the tool or try to do any rewiring on the tool’s electrical system. Contact a MILWAUKEE service facility for ALL repairs.
Maintaining Tools
Keep your tool in good repair by adopting a regular maintenance program. Before use, examine the general condition of your tool. Inspect guards, switches, tool cord set and extension cord for damage. Check for loose screws, misalignment, binding of moving parts, improper mounting, bro­ken parts and any other condition that may affect its safe operation. If abnormal noise or vibration occurs, turn the tool off immediately and have the problem corrected before further use. Do not use a damaged tool. T ag damaged tools “DO NOT USE” until repaired (see “Repairs”). Under normal conditions, relubrication is not neces­sary until the motor brushes need to be replaced. After six months to one year, depending on use, return your tool to the nearest MILWAUKEE service facility for the following:
• Lubrication
• Brush inspection and replacement
• Mechanical inspection and cleaning (gears, spin­dles, bearings, housing, etc.)
• Electrical inspection (switch, cord, armature, etc.)
• Testing to assure proper mechanical and electrical operation
WARNING T o reduce the risk of injury ,
electric shock and damage to the tool, never immerse your tool in liquid or allow a liquid to fl ow inside the tool.
Cleaning
Clean dust and debris from vents. Keep the tool handles clean, dry and free of oil or grease. Use only mild soap and a damp cloth to clean your tool since certain cleaning agents and solvents are harmful to plastics and other insulated parts. Some of these include: gasoline, turpentine, lacquer thin­ner, paint thinner, chlorinated cleaning solvents, ammonia and household detergents containing ammonia. Never use fl ammable or combustible solvents around tools.
Repairs
If your tool is damaged, return the entire tool to the nearest service center.
Brush Life
Proper care and lubrication are important factors in prolonging the useful life of this tool. This tool has been lubricated at the factory. Under normal conditions, relubrication is not necessary until brush replacement is called for. The need for brush replacement is indicated by one or more of the following:
• Excessive arcing between brushes and commutator
• Ineffi cient or interrupted operation
• Failure of the tool to start
ACCESSORIES
WARNING T o reduce the risk of injury ,
always unplug the tool before attaching or removing accessories. Use only specifi cally recommended accessories. Others may be hazardous.
For a complete listing of accessories refer to your MILWAUKEE Electric Tool catalog or go on-line
to www.milwaukeetool.com. To obtain a catalog, contact your local distributor or a service center.
6
LIMITED WARRANTY - USA AND CANADA
Every MILWAUKEE power tool (including cordless product – tool, battery pack(s) - see separate & distinct CORDLESS BATTERY PACK LIMITED WARRANTY statements & battery charger and Work Lights*) is war­ranted to the original purchaser only to be free from defects in material and workmanship. Subject to certain exceptions, MILWAUKEE will repair or replace any part on an electric power tool which, after examination, is determined by MILWAUKEE to be defective in material or workmanship for a period of fi ve (5) years* after the date of purchase unless otherwise noted. Return of the power tool to a MILWAUKEE factory Service Center location or MILWAUKEE Authorized Service Station, freight prepaid and insured, is required. A copy of the proof of purchase should be included with the return product. This warranty does not apply to damage that MILWAUKEE determines to be from repairs made or attempted by anyone other than MILWAUKEE authorized personnel, misuse, alterations, abuse, normal wear and tear, lack of maintenance, or accidents. *The warranty period for, Job Site Radios, M12™ Power Port, M18™ Power Source, and T rade T itan™ Indus­trial Work Carts is one (1) year from the date of purchase. The warranty period for a LED Work Light and LED Upgrade Bulb is a limited LIFETIME warranty to the original purchaser only, if during normal use the LED bulb fails the Work Light or Upgrade Bulb will be replaced free of charge. *This warranty does not cover Air Nailers & Stapler, Airless Paint Sprayer, Cordless Battery Packs, Gasoline Driven Portable Power Generators, Hand Tools, Hoist – Electric, Lever & Hand Chain, M12™ Heated Jackets, Reconditioned product and Test & Measurement products. There are separate and distinct warranties avail­able for these products. Warranty Registration is not necessary to obtain the applicable warranty on a MILWAUKEE power tool product. The manufacturing date of the product will be used to determine the warranty period if no proof of purchase is provided at the time warranty service is requested. ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT REMEDIES DESCRIBED HEREIN IS A CONDITION OF THE CONTRACT FOR THE PURCHASE OF EVERY MILWAUKEE PRODUCT . IF YOU DO NOT AGREE TO THIS CONDITION, YOU SHOULD NOT PURCHASE THE PRODUCT. IN NO EVENT SHALL MIL- WAUKEE BE LIABLE FOR ANY INCIDENTAL, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, OR FOR ANY COSTS, ATTORNEY FEES, EXPENSES, LOSSES OR DELAYS ALLEGED TO BE AS A CONSEQUENCE OF ANY DAMAGE TO, FAILURE OF, OR DEFECT IN ANY PRODUCT INCLUDING, BUT NOT LIMITED TO, ANY CLAIMS FOR LOSS OF PROFITS. SOME STA TES DO NOT ALLOW THE EXCLUSION OR LIMIT A TION OF IN­CIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMIT A TION OR EXCLUSION MA Y NOT APPL Y TO YOU. THIS W ARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES, WRITTEN OR ORAL. TO THE EXTENT PERMITTED BY LAW, MILWAUKEE DISCLAIMS ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMIT A TION ANY IMPLIED W ARRANTY OF MERCHANTABILITY OR FITNESS FOR A PAR TICULAR USE OR PURPOSE; TO THE EXTENT SUCH DISCLAIMER IS NOT PERMITTED BY LAW , SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY AS DESCRIBED ABOVE. SOME ST A TES DO NOT ALLOW LIMITA TIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU, THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. This warranty applies to product sold in the U.S.A. and Canada only. Please consult the ‘Service Center Search’ in the Parts & Service section of MILWAUKEE’s website www.mil- waukeetool.com or call 1.800.SAWDUST (1.800.729.3878) to locate your nearest service facility for warranty and non-warranty service on a Milwaukee electric power tool.
LIMITED WARRANTY - MEXICO, CENTRAL AMERICA AND CARIBBEAN
TECHTRONIC INDUSTRIES' warranty is for 5 year since the original purchase date. This warranty card covers any defect in material and workmanship on this Power Tool. To make this warranty valid, present this warranty card, sealed/stamped by the distributor or store where you pur­chased the product, to the Authorized Service Center (ASC). Or , if this card has not been sealed/stamped, present the original proof of purchase to the ASC. Call toll-free 1 800 832 1949 to fi nd the nearest ASC, for service, parts, accessories or components.
Procedure to make this warranty valid
Take the product to the ASC, along with the warranty card sealed/stamped by the distributor or store where you pur­chased the product, and there any faulty piece or component will be replaced without cost for you. We will cover all freight costs relative with this warranty process.
Exceptions
This warranty is not valid in the following situations: a) When the product is used in a different manners from the end-user guide or instruction manual. b) When the conditions of use are not normal. c) When the product was modifi ed or repaired by people not authorized by TECHTRONIC INDUSTRIES. Note: If cord set is damaged, it should be replaced by an Authorized Service Center to avoid electric risks.
SERVICE AND ATTENTION CENTER
Model:
Av Presidente Mazarik 29 Piso 7, 11570 Chapultepec Morales Miguel Hidalgo, Distrito Federal, Mexico
Date of Purchase:
Ph. 52 55 4160-3547
Distributor or Store Stamp:
IMPORTED AND COMMERCIALIZED BY: TECHTRONIC INDUSTRIES MEXICO, .S.A. DE C.V. Av Presidente Mazarik 29 Piso 7, 11570 Chapultepec Morales Miguel Hidalgo, Distrito Federal, Mexico
7
Loading...
+ 7 hidden pages