WIRING INSTRUCTIONS
TITLE
SINGLE REDUCTION PISTOL GRIP TOOLS
MILWAUKEE ELECTRIC TOOL CORP. 13135 WEST LISBON RD. BROOKFIELD, WIS.
FOR DOUBLE INSULATED TOOLS DISREGARD GREEN GROUND WIRE #3 AND THE GROUNDING TERMINAL
Grounding terminal
Green ground wire #3 connects to male tab of grounding terminal. Position terminal as shown. (Grounded models only).
Route blue brush wire #6 and white brush wire #5 through wire traps over rear bearing bore as shown.
Rear bearing bore
T2
Heat Sink
Jumper
T2
(T1)
Wire
DATE
Jan. 2003
Route green ground wire #3 and jumper wire (white) in recessed area of brush card as shown.
In the main trap, route green ground wire #3 in the bottom followed by the white wire #2 and black wire #4 on the top.
Route black lead #4 through any of the three traps on the tab of the motor housing and insert into hole 2 on bottom of switch (Hole is marked with a 2 on side of switch).
Route green ground wire #3 and white wire #2 around the post in the motor housing. Wires cannot touch the heat sink of the switch.
Post
Black wire #1 Black wire #4
If screw is present seat screw fully.
BULLETIN
58-01-1800
SCHEMATIC
Bottom view of switch
For grounded tools with 3-wire quik-lok cords,
Insert black wire #1 in the hole marked
2↓ on the bottom
of the switch
Fixed cord shown
.25 min.
orientate the pin housing assembly as shown and place white wire #2 first into the bottom of the handle portion of the motor housing.
WIRING SPECIFICATIONS
Wire
No.
Wire
Color
Origin or
Gauge
Length
Terminals, Connectors and 1 or 2 End Wire Preparation
1 Black * ----- *Component of cord set, pin hsg. assy. or blade hsg. assy. 2 White * ----- *Component of cord set, pin hsg. assy. or blade hsg. assy.
3 Green * ----- *Component of cord set, pin hsg. assy. or blade hsg. assy.
4 Black ** ----- **Component of the brush card assembly.
5 White ** ----- **Component of the brush card assembly.
6 Blue ** ----- **Component of the brush card assembly.
7 Brown ** ----- **Component of the brush card assembly.
BULK LEAD WIRE - BULLETIN NO. 58-01-0003
For double insulated tools with 2-wire quik-lok cords,
orientate the blade housing assembly as shown and place white wire #2 first into the bottom of the handle portion of the motor housing.
TERMINAL DESCRIPTION
Part No.Code
T1 23-74-0605 1
T2 23-74-1060 4
Qnty.