WIRING INSTRUCTIONS
TITLE
MILWAUKEE ELECTRIC TOOL CORP. 13135 WEST LISBON RD. BROOKFIELD, WIS.
Cord jacket to extend past
cord clamp approx. 1/4".
Top View
BODY GRIP ROUTER
Connector Terminal (Jumper)
No. 23-74-0055
BULLETIN
DATE
Oct. 2003
SEE REVERSE SIDE FOR MODELS
WHERE WIRE #3 IS A SEPARATE
LEADWIRE ASSEMBLY AND IS NOT
SOLDERED TO THE SWITCH.
Remove slack from cord wires #1
and #2 between wire traps. Wires
58-01-0705
are not to extend into frame
opening.
Black cord wire #1 is
connected to the switch.
White cord wire #2 is
connected to the field
terminal as shown.
CORD
Black
FIELD
ARM
Black
White
WIRING SCHEMATIC
WIRING SPECIFICATIONS
Wire Wire Origin or
No. Color Part No. Gauge Length Terminals, Connectors and End Wire Preparation
1 Black Cord 16 4-3/4" Component of cord assembly. Strip 3/16" for T1.
2 White Cord 16 4-3/4" Component of cord assembly. Strip 3/16" for T3.
3 Black Switch 18 2-1/2" Component of switch assembly. Strip 3/16" for T2.
BULK LEAD WIRE - BULLETIN 58-01-0003
Route black switch lead #3
to brush holder, as shown.
Black switch lead #3 must
be placed in wire trap prior
to white cord lead #2.
Order of cord wire placement
in traps are interchangeable.
Route brush shunt wires
(2 places) to brush holder,
as shown.
NOTE:
All lead lengths are before stripping.
All leads must be held to ± .125"
unless specified elsewhere.
Strip wire per ES 13-11.
Crimp terminals per ES 13-15.
TERMINAL DESCRIPTION
Qty.Code Part No.
T1 23-74-0065 1
T2 23-74-1060 1
T3 23-74-0605 1
Drwg. 2
Cord jacket to extend past
cord clamp approx. 1/4".
Top View
Connector Terminal (Jumper)
No. 23-74-0055
SEE REVERSE SIDE FOR MODELS
WHERE WIRE #3 IS A COMPONENT
OF THE SWITCH AND IS SOLDERED
ONTO THE TOP TERMINAL.
Remove slack
from the cord wires #1 and #2
between wire traps.
Wires are not to extend into
the frame opening.
Black cord wire #1 is
connected to the switch.
White cord wire #2 is
connected to the field
terminal as shown.
Connect T1 from the black
leadwire assembly #3 to the top
terminal on the switch. Route
#3 to the brush holder and
connect T2, as shown. Black
leadwire #3 must be placed
in the wire trap prior to the
white cord lead #2.
CORD
Black
FIELD
ARM
Black
White
WIRING SCHEMATIC
WIRING SPECIFICATIONS
Wire Wire Origin or
No. Color Part No. Gauge Length Terminals, Connectors and End Wire Preparation
1 Black Cord 16 4-3/4" Component of cord assembly. Strip 3/16" for T1.
2 White Cord 16 4-3/4" Component of cord assembly. Strip 3/16" for T3.
3 Black 23-94-0040 18 2-1/2" Leadwire assembly. Strip 3/16" for T1 and T2.
BULK LEAD WIRE - BULLETIN 58-01-0003
Order of cord wire placement
in traps are interchangeable.
Route brush shunt wires
(2 places) to brush holder,
as shown.
NOTE:
All lead lengths are before stripping.
All leads must be held to ± .125"
unless specified elsewhere.
Strip wire per ES 13-11.
Crimp terminals per ES 13-15.
TERMINAL DESCRIPTION
Qty.Code Part No.
T1 23-74-0065 2
T2 23-74-1060 1
T3 23-74-0605 1