Warning notices must be observed to ensure personal safety as well as that of others, and to
protect the product and the connected eq uip m ent . These w ar ning notices are accompanied
by a clarification of the level of caution to be observed.
Qualified Personnel
This device/system may only be set up and operated in conjunction with this manual.
Qualified personnel are on ly authorized to install and operate this equip m ent in accordance
with established safety practices and standards.
Warning: This product can only function properly and safely if it is correctly transported,
stored, installed, set up, oper at ed, and maintained.
Note: Always use product in accordance with specifications.
Copyright Siemens Milltronics Process
Disclaimer of Liability
Instruments Inc. 2000. All Rights Reserved
This document is available in bound version and in
electronic version. We encourage users to
purchase authorized bound manuals, or t o view
electronic versions as designed and authored by
Siemens Milltronics Process Instruments Inc.
Siemens Milltronics Process Instruments Inc. will
not be responsible for the content s of partial or
whole reproductions of either bound or electronic
versions.
MILLTRONICS®is a registered t rademark of Siemens Milltronics Process Instrume nt s Inc.
Contact SMPI Technical Publications at the following address:
Technical Publications
Siemens Milltronics Process Instruments Inc.
1954 Technology Drive, P.O. Box 4225
Peterborough, Ontario, Ca nad a, K9J 7B1
Email: techpubs@milltronics.com
While we have verified the contents of
this manual for agreement with t he
instrumentation described, variations
remain possible. Thus we cannot
guarantee full agreement. The
contents of this manual are regularly
reviewed and corrections are included
in subsequent editions. We welc ome
all suggestions for improvement.
Technical data subject to change.
For the library of SMPI instruction manuals, visit our Web site: www.milltronics.com
Installation Diagram for the XPS 10 F ...............................................26
PL-551XPS 10/15 F Series TransducerPage 3
Page 4XPS 10/15 F Series TransducerPL-551
About Milltronics’ Transducers
The Echomax XPS F series of transducers operates in association with
Milltronics ultrasonic level monitoring products.
The transducer operates by converting electrical
pulses that are provided by the transceiver into
ultrasonic pulses. When transmitted, these
ultrasonic pulses reflect from the material surface
and echo back to the transducer. The echo is
converted back to an electrical signal, and is
interpreted by the Milltronics tranceiver using
our proven Sonic Intelligence™ algorithms.
About the…
hazardous seal
(XPS 10 F
series only)
transducer
transducer face
The effective acoustical energy is emitted from
the transducer face and radiated outward,
decreasing in amplitude at a rate inversely
proportional to the square of the distance.
Maximum power is radiated axially
(perpendicular) from the transducer face in a
line referred to as the axis of transmission.
Where power is reduced by half (– 3 dB), a
conical boundary defining the sound beam,
centered about the axis of transmission, is
established. The diametric measurement of
the cone in degrees defines the beam
angle. Impedance matching techniques are
used to optimize the transfer of power from the transducer into air and vice
versa.
The XPS F series transducers incorporate an integral temperature sensor
that reports the air temperature at the transducer to the transceiver. The
connection is transparent, in that both the ultrasonic and temperature
components of the transducer use the same leads.
-3db
boundary
axis of
transmission,
perpendicular
to transducer
face
Hazardous Area Applications
The Echomax XPS F series of transducers can be used in hazardous areas.
For the XPS 10 F series transducer, a hazardous seal must be used to suit
hazardous area classification. This seal is
not
supplied by Milltronics.
The XPS 15 F comes equipped with a stainless steel coupling suitable for
use in hazardous locations.
PL-551XPS 10/15 F Series TransducerPage 5
About the…
Page 6XPS 10/15 F Series TransducerPL-551
Specifications
XPS 10 F Series Transducers
Measurement Range:
{
0.3 – 10m (1 – 33ft)
Frequency:
{
43kHz
Beam Angle:
{
12°
Environmental
{
location:
{
altitude:
{
ambient temperature:{-20 to 95°C (-4 to 203°F)
{
pollution degree:
{
indoor/outdoor
{
2000m maximum
{
4
Specifications
Construction
{
exposure:
{
colour:
{ mounting:{ 1” NPT conduit connection
{
options:
{
cable:
{
{
{
{
{
{
®1
Kynar
slate gray
factory flange to suit ANSI standard
submergence shield, where flooding can occur
split flange for field mounting to suit ANSI