Model# CPT-210 Sensing Edge
Assembly Instructions
IMPORTANT:
PLEASE ENSURE THAT THE FOLLOWING INSTRUCTIONS ARE FOLLOWED
CPT TECHNOLOGY - RESISTIVE SAFETY EDGES
Components List:
CPT210-K-5
50 ft. - CPT223 extrusion
5 - Wired End Plugs
5 - Non- Terminated End Plugs or Terminated with 8.2k/10k/DC
1 - Tube Vyna Bond Glue
Step 1: Cut the Extrusion
1- Measure the width of the door.
2- Cut the extrusion 1 inch less than the door width.
Note: Ensure that the cut be square and free of rubber fragments.
Step 2: Insert the Blank End Plug and Glue.
1- Insert 50% of the blank or t
2- Apply a continuous bead of Vyna Bond glue ONLY
3- Fully insert plug and hold firmly to fully seat the plug and form an
airtight seal.
4- Use caution, do not allow glue to contact conductive tongue.
Step 3: Insert the Wired End Plug and Glue.
1- Insert 50% of the wired end plug into the extrusion.
2- Apply a continuous bead of Vyna Bond ONLY
3- Fully insert plug and hold firmly to fully seat the plug and form an
airtight seal.
4- Use caution, do not allow glue to contact conductive tongue.
erminated end plug into the extrusion.
around the perimeter.
around the perimeter.
Use Caution:
Do NOT allow glue on
the conductive tongue.
For more information, please visit www.devancocanada.com or call toll free at 855-931-3334
![](/html/35/35c1/35c1479f45127c891f55ca137b0195bfdc99fef1d10614c0b55fa1a158a4aa09/bg2.png)
Step 4: Connection Cable
1- Press the connection cable into the groove on the End Plug to direct it
towards the junction box.
Step 5: Wiring Connections
1- Connect black wire from edge sensor to Coil Cord black wire.
Connect white wire from edge sensor to Coil Cord white wire.
Connect Coil Cord wires to Operator’s Safety Reverse input terminals.
NOTE: The Sensing Edge should be checked periodically (at least once per month) for any signs of damage,
cuts, loss of sensitivity or water damage.
Figure A.
Rolling Steel Door
Terminated
End Plug
includes an
8.2K Ohm
Non- Terminated /
Terminated End Plug
monitoring
with 8.2k/10k/DC
resistor
Figure B.
Sectional Door
eeeeeeeeeeeeeeeeeeeeeeeeeeeeee
Junction Box for Sensing Edge
Termination Only
2-Wire
Sensing
Edge
Wired
End Plug
Operator
Connect Coil Cord wires
to Operator’s Safety Reverse
input terminals
eeeeeeeeeeeeeeeeeeeeee
Connect Sensing Edge Output
wires to
Coil Cord wires
NOTE:
An Interface Module (Model EIM-101) is
available for mechanical operators that
utilize a 24 volt control circuit.
Logic operators normally do not require
an Interface Module.