Miller Welder Owner's Manual

OM-245 849A
2009−11
Processes
Descriptio n
STi 203
TIG (GTAW) Welding
Stick (SMAW) Welding
Arc Welding Power Source
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way.
That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy.
Today, the people that build and sell Miller products continue the tradition. They’re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your Miller products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite. We’ve made installation and operation quick and easy. With Miller you can count on years of reliable service with proper maintenance. And if for some reason the unit needs repair, there’s a Troubleshooting section that will help you figure out what the problem is. The parts list will then help you to decide which exact part you may need to fix the problem. Warranty and service information for your particular model are also provided.
Working as hard as you do
− every power source from Miller is backed by the most hassle-free warranty in the business.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − DEFINITIONS 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Warning Label Definitions 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. WEEE Symbol (For Products Sold Within The EU) 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Symbols And Definitions 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − SPECIFICATIONS 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Important Information Regarding CE Products (Sold Within The EU) 7. . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Specifications 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Volt-Ampere Curves 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Duty Cycle And Overheating 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − INSTALLATION 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Serial Number And Rating Label Location 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Selecting A Location 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Weld Output Terminals And Selecting Cable Sizes* 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Remote 14 Receptacle Information 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. TIG Lift-Arc DCEN (Direct Current Electrode Negative) Connections 11. . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Stick DCEP (Direct Current Electrode Positive) Connections 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Electrical Service Guide 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Connecting Input Power 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − OPERATION 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Controls 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Process Control 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Lift-Arc Start Procedure 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-4. Stick Start Procedure − Scratch Start Technique 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5. Amperage Control 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-6. DIG Control 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − MAINTENANCE AND TROUBLESHOOTING 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Routine Maintenance 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Blowing Out Inside Of Unit 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Troubleshooting 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − ELECTRICAL DIAGRAMS 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 − HIGH FREQUENCY 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-1. Welding Processes Requiring High Frequency 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-2. Incorrect Installation 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-3. Correct Installation 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 − SELECTING AND PREPARING A TUNGSTEN FOR DC OR AC WELDING WITH INVERTER
MACHINES 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-1. Selecting Tungsten Electrode (Wear Clean gloves To Prevent Contamination Of Tungsten) 22. . . . . . . .
9-2. Preparing Tungsten Electrode For DC Electrode Negative (DCEN) Welding Or AC W elding With Inverter
Machines 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 10 − GUIDELINES FOR TIG WELDING (GTAW) 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-1. Positioning The Torch 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-2. Torch Movement During Welding 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-3. Positioning Torch Tungsten For Various Weld Joints 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 11 − STICK WELDING (SMAW) GUIDELINES 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 12 − PARTS LIST 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY
DECLARATION OF CONFORMITY
for European Community (CE marked) products.
ITW Welding Products Italy S.r.l Via Privata Iseo 6/E, 20098 San Giuliano M.se, (MI) Italy de clares that the product(s) identified in this declaration conform to the essential requirements and provisions of the stated Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Product Stock Number
STi203 059 016 008
Council Directives:
2006/95/EC Low Voltage
2004/108/EC Electromagnetic Compatibility
2006/42/EEC Machinery Directive
Standards:
IEC 609741 Arc Welding Equipment  Welding Power Sources: edition 3, 200507.
IEC 6097410 Arc Welding Equipment Electromagnetic Compatibility Requirements: edition 2.0, 200708
EN 50445:2008 Product family standard to demonstrate compliance of equipment for resistance welding, arc welding and allied processes with the basic restrictions related to human exposure to electromagnetic fields (0Hz300Hz)
EU Signatory:
October 31st, 2009
_____________________________________________________________________________
Mark Lowther
EUROPEAN DIRECTOR, TECHNOLOGY & PRODUCT DEVELOPMENT
Date of Declaration
956 142 704
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
s s
t
c
,
y
7
Protect yourself and others from injury — read and follow these precautions.
1-1. Symbol Usage
som _2009−08
DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury. The possible hazards are shown in the adjoining symbols or explained in the text.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury. The possible hazards are shown in the adjoining symbols or ex­plained in the text.
NOTICE − Indicates statements not related to personal injury .
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-5. Read and follow all Safety Standards.
Only qualified persons should install, operate, maintain, and repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shock or severe burns. The electrode and work circuit i electrically live whenever the output is on. The inpu power circuit and machine internal circuits are also live when power is on. In semiautomatic or automati wire welding, the wire, wire reel, drive roll housing and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperl grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry , hole-free insulating gloves and body protection. D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process. D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the follow-
ing electrically hazardous conditions are present: in damp locations or while wearing wet clothing; on metal structures such as floors, gratings, or scaffolds; when in cramped positions such as sitting, kneeling, or lying; or when there is a high risk of unavoid­able or accidental contact with the workpiece or ground. For these conditions, use the following equipment in order presented: 1) a semiautomatic DC constant voltage (wire) welder, 2) a DC manual (stick) welder, or 3) an AC welder with reduced open-circuit volt­age. In most situations, use of a DC, constant voltage wire welder is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards).
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC SHOCK, MOVING P ARTS, and HOT PARTS hazards. Consult sym­bols and related instructions below for necessary actions to avoid the hazards.
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet.
D When making input connections, attach proper grounding conduc-
tor first − double-check connections.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use. D Do not use worn, damaged, undersized, or poorly spliced cables. D Do not drape cables over your body. D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding ma-
chines at the same time since double open-circuit voltage will be present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level. D Keep all panels and covers securely in place. D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists in inverter weld­ing power sources AFTER removal of inputpower.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section before touching any parts.
HOT PARTS can burn.
D Do not touch hot parts bare handed. D Allow cooling period before working on equip-
ment.
D To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and clothing to prevent burns.
OM-245 849 Page 1
FUMES AND GASES can be hazardous.
F)
d
r t
Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.
D Keep your head out of the fumes. Do not breathe the fumes. D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases.
D If ventilation is poor, wear an approved air-supplied respirator. D Read and understand the Material Safety Data Sheets (MSDSs)
and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch­person nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breath­ing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.
ARC RAYS can burn eyes and skin.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
D Use only correct fuses or circuit breakers. Do not oversize or by-
pass them.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
FLYING METAL or DIRT can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool, they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut of f shielding gas supply when not in use. D Always ventilate confined spaces or use
approved air-supplied respirator.
Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.
D Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and sparks when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant
material (leather, heavy cotton, or wool) and foot protection.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly of f from the welding arc. The flying sparks, hot
burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material. D Protect yourself and others from flying sparks and hot metal. D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby. D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see Safety Standards).
D Do not weld where the atmosphere may contain flammable dust,
gas, or liquid vapors (such as gasoline).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock, sparks, and fire hazards.
D Do not use welder to thaw frozen pipes.
OM-245 849 Page 2
workpiece, and hot equipment can cause fires and
ELECTRIC AND MAGNETIC FIELDS (EM can affect ImplantedMedical Devices.
D Wearers of Pacemakers and other Implante
Medical Devices should keep away.
D Implanted Medical Device wearers should consult their docto
and the device manufacturer before going near arc welding, spo welding, gouging, plasma arc cutting, or induction heating operations.
NOISE can damage hearing.
Noise from some processes or equipment can damage hearing.
D Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully .
D Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits. D Never drape a welding torch over a gas cylinder. D Never allow a welding electrode to touch any cylinder. D Never weld on a pressurized cylinder − explosion will result. D Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve. D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient n u m -
ber of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA) publication P-1 listed in Safety Standards.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING EQUIPMENT can injure.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
D Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
D Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manu­ally lifting heavy parts or equipment.
OVERUSE can cause OVERHEATING
D Allow cooling period; follow rated duty cycle. D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
FLYING SPARKS can injure.
D Wear a face shield to protect eyes and face. D Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper face, hand, and body protection.
D Sparks can cause fires — keep flammables away.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
MOVING PARTS can injure.
D Keep away from moving parts. D Keep away from pinch points such as drive
rolls.
WELDING WIRE can injure.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading welding wire.
MOVING PARTS can injure.
D Keep away from moving parts such as fans. D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
D Read and follow all labels and the Owner’s
Manual c a r efully before installing, operating, or servicing unit. Read the safety information at the beginning of the manual and in each section.
D Use only genuine replacement parts from the manufacturer. D Perform maintenance and service according to the Owner’s
Manuals, industry standards, and national, state, and local codes.
H.F. RADIATION can cause interference.
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
D The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa­tion.
D If notified by the FCC about interference, stop using the
equipment at once.
D Have the installation regularly checked and maintained. D Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.
ARC WELDING can cause interference.
D Electromagnetic energy can interfere with
sensitive electronic equipment such as computers and computer-driven equipment such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
D To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
D Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
D Be sure this welding machine is installed and grounded
according t o this manual.
D If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.
OM-245 849 Page 3
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)
Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
1-5. Principal Safety Standards
Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding and Cutting, American Welding Society Standard AWS F4.1, from Glob-
al Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).
National Electrical Code, NFP A Standard 70, from National Fire Protec­tion Association, Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly , V A 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 5060 Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone: 800-463-6727, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protec­tion, ANSI Standard Z87.1, from American National Standards Institute,
For Gasoline Engines:
Engine exhaust contains chemicals known to the State of California to cause cancer, birth defects, or other reproduc­tive harm.
For Diesel Engines:
Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, web­site: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFP A Standard 51B, from National Fire Protection Association,
Quincy, M A 0 2 2 6 9 ( p h o n e : 1 - 8 0 0 - 3 4 4 - 3 555, websi t e : w w w.nfpa.org. OSHA, Occupational Safety and Health Standards for General Indus-
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Super­intendent of Documents, P .O. Box 371954, Pittsburgh, PA 15250-7954 (phone: 1-866-512-1800) (there are 10 OSHA Regional Offices— phone for Region 5, Chicago, is 312-353-2220, website: www.osha.gov).
U.S. Consumer Product Safety Commission (CPSC), 4330 East West Highway, Bethesda, MD 20814 (phone: 301-504-7923, website: www.cpsc.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The Na­tional Institute for Occupational Safety and Health (NIOSH), 1600 Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website: www.cdc.gov/NIOSH).
1-6. EMF Information
Electric current flowing through any conductor causes localized electric and magnetic fields (EMF). Welding current creates an EMF field around the welding circuit and welding equipment. EMF fields may inter­fere with some medical implants, e.g. pacemakers. Protective measures for persons wearing medical implants have to be taken. For example, access restrictions for passers−by or individual risk assess­ment for welders. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
1. Keep cables close together by twisting or taping them, or using a cable cover.
2. Do not place your body between welding cables. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep head and trunk as far away from the equipment in the welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the device manufacturer before performing or going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations. If cleared by your doctor, then following the above procedures is recom­mended.
OM-245 849 Page 4
SECTION 2 − DEFINITIONS
2-1. Warning Label Definitions
Warning! Watch Out! There are possible hazards as shown by the symbols.
1 Electric shock from welding electrode
or wiring can kill.
1.1 Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves.
1.2 Protect yourself from electric shock by insulating yourself from work and ground.
1.3 Disconnect input plug or power before working on machine.
2 Breathing welding fumes can be
2.1 Keep your head out of the fumes.
2.2 Use forced ventilation or local exhaust
2.3 Use ventilating fan to remove fumes. 3 Welding sparks can cause explosion
3.1 Keep flammables away from welding.
3.2 Welding sparks can cause fires. Have
1 1.1 1.2 1.3
hazardous to your health.
to remove the fumes.
or fire.
Do not weld near flammables.
a fire extinguisher nearby, and have a watchperson ready to use it.
4 4.1
3.3 Do not weld on drums or any closed containers.
4 Arc rays can burn eyes and injure
skin.
4.1 Wear hat and safety glasses. Use ear protection and button shirt collar. Use welding helmet with correct shade of filter. Wear complete body protection.
5 Become trained and read the
instructions before working on the machine or welding.
6 Do not remove or paint over (cover)
the label.
2 2.1 2.2 2.3
3 3.1 3.2 3.3
5
6
S-179 310-A
OM-245 849 Page 5
2-2. WEEE Symbol (For Products Sold Within The EU)
I
Hz
2-3. Symbols And Definitions
Do not discard product (where ap­plicable) with general waste.
Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collec­tion facility.
Contact your local recycling office or your local distributor for further information.
A V
X
U
Amperes
Volts Voltage Input
Voltage Output Off Remote
Protective Earth
(Ground)
On Percent Positive Negative
Alternating
Current
Duty Cycle Direct Current Line Connection
Primary Voltage
1
IP
Output/On
Process High Temperature
Hertz Arc Force (DIG)
Degree Of Protection
I
1max
Gas Tungsten Arc
Welding (GT AW)
3 Phase Static Frequency
Converter-Transformer-Rectifier
Rated Maximum
Supply Current
I
U
I
1eff
Shielded Metal Arc
Welding (SMAW)
Lift-Arc Start
(GTAW)
Increase/Decrease
Of Quantity
Rated Welding
2
2
Current
Conventional Load
Voltage
Maximum Effective
Supply Current
U
0
OM-245 849 Page 6
Rated No Load
Voltage (A verage)
SECTION 3 − SPECIFICATIONS
t
3-1. Important Information Regarding CE Products (Sold Within The EU)
! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure information.
S The EMF assessment on this equipment was conducted at 0.5 meter. S At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
3-2. Specifications
Welding Process
Stick
TIG
Rated Output
200 A @ 28
VDC,
40% Duty
Cycle
200 A @ 18
VDC,
40% Duty
Cycle
Welding
Amperage
Range
5 − 200 85 VDC
3-3. Volt-Ampere Curves
100
Max.
Open-Circui
Voltage (U0)
Amperes Input At Rated
Output, 50/60Hz
380 400 440
13.5 12.8 11.5 8.86 6.51
8.7 8.3 7.5 5.73 4.2
230 VAC Input
KVA KW Dimensions Weight
Length: 470 mm
(18-1/2 in.)
Width: 192 mm
(7-9/16 in.)
Height: 333 mm
(13-3/8 in.)
Volt-ampere curves show minimum and maximum voltage and amper­age output capabilities of welding power source. Curves of other set­tings fall between curves shown.
13 Kg
(28.6 lb)
80
60
Volts
40
20
0
0 50 100 150 200 250
TIG Min
Stick Min
Amperes
TIG/Stick Max
OM-245 849 Page 7
3-4. Duty Cycle And Overheating
250
200
150
100
OUTPUT AMPERES
Duty Cycle is percentage of 10 mi n ­utes that unit can weld at rated load without overheating.
If unit overheats, output stops and cooling fan runs. Wait fifteen min­utes for unit to cool. Reduce amper­age or voltage, or duty cycle before welding.
NOTICE − Exceeding duty cycle can damage unit and void warranty.
STICK/TIG
50
0
10
Overheating
50
% DUTY CYCLE
4 Minutes Welding 6 Minutes Resting
0
100
A or V
OM-245 849 Page 8
Minutes
15
OR
Reduce Duty Cycle
SECTION 4 − INSTALLATION
4-1. Serial Number And Rating Label Location
The serial number and rating information for the power source is located on the rear of the machine. Use the rating labels to determine input power requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.
4-2. Selecting A Location
1 Line Disconnect Device Locate unit near correct input
power supply.
Location And Airflow
! Special installation may be
required where gasoline or volatile liquids are present − see NEC Article 511 or CEC Section 2 0 .
460 mm
(18 in.)
1
460 mm
(18 in.)
246 381-A
OM-245 849 Page 9
4-3. Weld Output Terminals And Selecting Cable Sizes*
-
-
,
-
NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is 30 m (100 ft) from the workpiece, the total cable length in the weld circuit is 60 m (2 cables x 30 m). Use the 60 m (200 ft) column to determine cable size.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Weld Output
Terminals
! Turn off power be
fore connecting to weld output termi nals.
! Do not use worn
damaged, under sized, or poorly spliced cables.
30 m (100 ft) or Less
10 − 60%
mm
Duty
Cycle
2
(AWG)
Welding
Amperes
100 20 (4) 20 (4) 20 (4) 30 (3) 35 (2) 50 (1) 60 (1/0) 60 (1/0) 150 30 (3) 30 (3) 35 (2) 50 (1) 60 (1/0) 70 (2/0) 95 (3/0) 95 (3/0)
60 − 100%
Duty
Cycle
2
mm
(AWG)
Not Exceeding***
45 m
(150 ft)
60 m
(200 ft)
70 m
(250 ft)
10 − 100% Duty Cycle
mm
2
(AWG)
90 m
(300 ft)
105 m
(350 ft)
120 m
(400 ft)
200 30 (3) 35 (2) 50 (1) 60 (1/0) 70 (2/0) 95 (3/0) 120 (4/0) 120 (4/0)
* This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. ***For distances longer than those shown in this guide, call a factory applications representative. Milan Ref. S-0007-G 2009−08
4-4. Remote 14 Receptacle Information
Socket* Socket Information
AJ
K
B
L
NH
C
M
D
F
E
I
G
14
A Contactor control 24 volts DC.
B Contact closure to A completes 24 volt DC
contactor control circuit and enables output.
OM-245 849 Page 10
246 381-A
REMOTE
OUTPUT
CONTROL
CHASSIS
C Output to remote control; +10 volts DC output to
remote control.
D 0 to +10 volts DC input command signal from
remote control.
E Remote control circuit common.
G Chassis common.
Loading...