Millennium Enterprises MRO-35 User Manual

Reverse Osmosis Drinking Water System
Millennium
Model MRO-35
PERFORMANCE DATA SHEET
Tested and Certied by NSF International against NSF/ANSI Standard 58 for the reduction of: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cyst, Fluoride, Lead, Nitrate, Nitrite, Radium 226/228, Selenium and TDS.
This reverse osmosis system contains replaceable treatment components critical for effective performance. It is the user’s responsibility to, and the manufacturer strongly recommends that the user, periodically test the product water to verify that system is performing satisfactorily.
The Water Quality Monitor has been integrated into the system cover for instant monitoring at the touch of a button. The monitor compares the level of the total dissolved solids in the incoming (feed) water versus the product water and calculates the percent rejection. The monitor is preset to indicate a level of 75% rejection. NSF/ANSI Standard 58 requires a 75% total dissolved solids rejection to pass the requirement of the standard.
A green light indicates that the percent rejection is at or above the set (desired) value and that the system is producing quality water.
An amber light indicates that the product water quality is less than acceptable. Because the Water Quality Monitor was designed to operate best while the system is making water, a false reading may occur if tested when your R.O. drinking water system is not making water. Please empty the storage tank, wait 15 minutes for the system to begin making water, and test your water quality again. If the Water Quality Monitor light is
still amber, change the 9 volt battery and test your water quality again. If the Water Quality Monitor light is still amber, please contact a water treatment professional for service. The Water Quality Monitor requires a 9 volt battery, which is included.
If Millennium replacement lters and membranes are not used, health related contaminant reduction claims are invalid.
MILLENNIUM REVERSE OSMOSIS DRINKING WATER SYSTEM
SYSTEM RATING
Average T.D.S. Reduction: 93% System Production: 14 gallons per day (53 liters per day) Recovery Rating: 38% Efficiency Rating: 22%
Measured at 50 psig, 77°±2°F, 750±40 mg/L T.D.S., per section 6 of NSF/ANSI standard 58 product water to pressurized storage tank. Recovery rating means the percentage of the influent water to the membrane por tion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed. Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage. Sodium Chloride was used as a surrogate for T.D.S. System rating determined by laboratory testing at NSF.
MEMBRANE RATING
Membrane Production: 41-53 gallons per day (155–201 liters per day) Membrane T.D.S. Reduction: 96% minimum
Note: Measured at industry standard condition of 65 psig, 77°F, 250 ppm T.D.S., and discharging to atmosphere. Actual system production and contaminant reduction will depend upon water temperature, pressure, pH and T.D.S. level, membrane variation and usage pattern.
(The cyst reduction claim includes oocysts of Cryptosporidium and cysts of Giardia and Entamoeba.)
Water supplies that exceed limits for Hardness, Iron, Manganese and Hydrogen Sulfide require pretreatment.
REDUCTION PERFORMANCE CLAIMS:
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 58. Testing was performed under standard laborator y conditions. Actual per formance may vary.
APPLICATION GUIDELINES/SPECIFICATIONS AND FEATURES
Water Supply Parameters
Water Pressure: 40–100 psig
(280–690 kPa)
Water Temperature: 40°–100° F
(4°–38° C) pH Operating Range: 4–11 Optimum rejection at pH: 7.0 - 7.5 Max. T.D.S. Level: 2000 ppm
Chemical Limit
Hardness: <170 mg/l Iron: <0.1 mg/l Manganese: <0.05 mg/l
Hydrogen Sulfide: 0
NSF/ANSI 58 Standard Requirements
Actual Test
Results
Caution: Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
Test Parameters: pH 7.5±0.5 Turbidity < 1 NTU Temperature 77°±2° F Pressure 50 psig 1 Unless otherwise indicated. 2 Average based upon actual test data. 3 This system has been tested for the treatment of water containing
pentavalent arsenic (also known as As(V), As(+5), or arsenate) at concentrations of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of the Performance Data Sheet for further information.
4 This system is acceptable for treatment of influent concentrations
of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater.
5 The reduction of Radium was verified by using Barium as a surrogate
under NSF/ANSI Standard 58.
Influent Challenge
Concentration
(mg/l)
1
Maximum Allowable
Product Water Concentration
(mg/l)
1
Average %
Reduction
2
Arsenic (Pentavalent)
3
0.30 + 10% 0.010
98
Barium
10.0 + 10% 2.0
93
Cadmium
0.03 + 10% 0.005
98
Chromium (Hexavalent)
0.30 + 10% 0.1
91
Chromium (Trivalent)
0.30 + 10% 0.1
94
Copper
3.0 + 10% 1.3
98
Fluoride
8.0 + 10% 1.5
95
Lead
0.15 + 10% 0.010 98
Nitrate + Nitrite (both as N)
4
30.0 + 10% 10.0 80
Nitrate (as N)
4
27.0 + 10% 10.0 80
Nitrite (as N)
4
3.0 + 10% 1.0
77
Radium 226/228
5
25 pCi/l + 10% 5 pCi/l 80
Selenium
0.1 + 10% 0.05
96
Total Dissolved Solids
750 + 40 mg/l 187
93
Cysts
50,000#/ml
minimum
99.95% reduction requirement
99.99
MILLENNIUM REVERSE OSMOSIS DRINKING WATER SYSTEM
MODEL MRO-35
MODEL MRO-35
DRINKING WATER SYSTEM ASSEMBLY COMPONENTS
Sediment/Carbon Prefilter: 5 Micron/Activated Carbon Block Filter, Part No. S7128 Membrane Type: Thin Film Composite (T.F.C.), Part No. S1448RS Carbon Post Filter: Activated Carbon Filter, Part No. S7125 In-Line Carbon Post Filter: In-Line Activated Carbon Filter, Part No. S7206W-JG
Refer to owner’s manual for proper operation, installation instructions, warranty information, ser vice inter val recommendations, parts and service availability. See the test kit(s) for sampling instructions.