![](/html/75/752f/752fa82093574d80dad847d891dcf37557a7f316f3118e2fdfd6d0e41cc9d4a8/bg1.png)
Millennia
Media & Music Systems
AD-D96 User Guide revised 121808
Protecting Against Electrostatic Discharge
Static electricity can harm delicate components on
the AD-D96 board. To prevent static damage,
discharge static electricity from your body before you
touch any electronic components. You can do so by
touching an unpainted metal surface on the HV-3D’s
chassis.
Unplug the HV-3D’s AC power cord before
removing the top cover and changing settings
on the AD-D96 board.
Sample Rate kHz Rear Panel
44.1* X1 44
48 X1 48
88.2 X2 44
96 X2 48
Clocks - the AD-D96 should have only one clock
source. If running with the internal clock, make sure
SW2 is in the INT position and no external clock is
connected.
Sync Signals on the BNC connectors should
conform to the AES-3id specification. AES-3,
through an XLR-to-BNC transformer (Neutrik
NADITBNC-F or equivalent) will work fine.
S/PDIF works, but is not specified.
Clock Source SW2
Internal INT
External* EXT
*The arrows point to the
default jumper positions.
Clock Input J12
Word Clock* on
AES off
Millennia Media, Inc. 4600 Missouri Flat Road Placerville, CA 95667
http://www.mil-media.com
(530) 647-0750 Fax (530) 647-9921
Clock Termination
J14
110 ohms* on
Unterminated off
Clock Output J15
Word Clock* 2,3 2,3
AES 1,2 1,2
J17