Milestone PrestoCHILL Operator's Manual

PrestoCHILL
Flash Chiller for Frozen Sections
Operator Manual - MM138
PrestoCHILL
MM138-003 – Operator Manual
Please read the user manual before using the device.
PrestoCHILL
MM138-003 – Operator Manual
PrestoCHILL
MM138-003 – Operator Manual
PrestoCHILL
MM138-003 – Operator Manual
An instruction accompanied by this symbol provides important information and requires more attention.
An instruction accompanied by this symbol provides a cautionary statement: failure to follow the instruction may endanger the operator or cause damage to the instrument.
An instruction accompanied by this symbol provides a caution against electric shock. Be sure to follow the instruction to prevent accidents resulting from electric shock.
Biohazard.
Be careful: parts identified with this symbol are zones with risks of crushing hand and/or finger(s).
Surfaces identified with this symbol are at danger temperature.
CE logo: this instrument complies to European Community directives.
IVD medical device according to 98/79/EC directive.
Indicates a single-use medical device or one-patient use during a single procedure.
Indicates the manufacturer's batch code.
WEEE European directive symbol (2002/96/EC): Electric/electronic device do not throw out in the environment.
Manufacturer.
Fragile.
PrestoCHILL
MM138-003 – Operator Manual
Any other use of the instrument is considered improper and may void the warranty provided by the manufacturer.
PrestoCHILL
MM138-003 – Operator Manual
When not in use, it’s required to leave the USB protection inserted into the slot, as
shown in the picture above.
Before turning PrestoCHILL on (when coming from a storage room), let the unit reach working environmental conditions (at least half an hour).
It is very important to ship and move the PrestoCHILL system in a vertical position to avoid that the cooling plate could be damaged and unscrewed from its support.
PrestoCHILL
MM138-003 – Operator Manual
DO NOT OPEN THE CHASSIS. Failure to follow the instruction in the documentation might lead to a reduction of device safety. If the equipment is not working properly, please contact your supplier or the manufacturer.
Do not remove the instrument, optional, panels or cover. Only authorized and qualified SERVICE personnel may repair the instrument and access the instrument’s internal components.
It is important that normal standards of safety and good laboratory practices are employed. Always use common sense and the best known practice when operating the instrument.
The institution owning the instrument has primary responsibility for accident-free operation together with designated personnel who operate, service or repair it.
To avoid damage to the instrument, use only the reagents listed in chapter 1.8 Compatible Reagents. Failure to follow the instructions in the documentation might lead to a reduction of device safety.
Low Temperatures are present in this equipment. Extreme care should be taken. DO NOT let bare skin come into contact with metal surfaces.
PrestoCHILL
MM138-003 – Operator Manual
MILESTONE SRL
Via Fatebenefratelli, 1/5 – 24010 Sorisole (BG) –
ITALY
Tel. +39.035.4128264 Fax. +39.035.575498
PRESTO CHILL
REF
SERIAL NUMBER (SN)
FUSES
1.6AT 5X20
INPUT
MANUFACTURED:
Do not remove the side panels of the unit during the cleaning operations.
Before doing any operation disconnect the power supply. Do not use direct or high-pressure water to clean the instrument.
For safety reason, any operation without the individual protective devices must be avoided.
PrestoCHILL
MM138-003 – Operator Manual
PrestoCHILL
MM138-003 – Operator Manual
At least 2 people should remove the unit from its box and locate it on the bench.
Width: 420mm (17in)
Height: 680mm (27in)
Depth: 650mm (26in)
Width: 300mm (12in)
Height: 450mm (18in)
Depth: 540mm (22in)
Width: 700mm (28in)
Height: 800mm (31.5in)
Depth: 700mm (28in)
PrestoCHILL
MM138-003 – Operator Manual
PrestoCHILL
MM138-003 – Operator Manual
PrestoCHILL
MM138-003 – Operator Manual
Before connecting the plug to the laboratory’s socket CHECK that the power supply
voltage of the unit matches the power supply line of the laboratory. Damages occur when wrong power supplies the instrument.
See also the label of the instrument that provides some important information. Always communicate the S.N. of the unit to Customer Support.
PrestoCHILL
MM138-003 – Operator Manual
PrestoCHILL
MM138-003 – Operator Manual
1. Work area cover
2. Touch control terminal
3. Main switch
4. USB port
5. Embedding medium and spare optional storage area
6. Cool trap
1. Heat extractors
2. Heat extractors slim
3. Moulds for 30mm chucks
4. Moulds for 40mm chucks
We advise against the use of optional other than those provided by Milestone.
The standard heat extractor can be used with any type of mould among those listed in chapter 6.
The slim heat extractor can only be used with 5mm deep moulds.
The conformation used by the PrestoCHILL that ensures optimal performances is: four 5mm deep moulds and two moulds with depth of your choice.
For optimal results, Milestone recommends using 5mm deep moulds.
Do not work with a different conformation to that indicated above.
1
2
3
4
PrestoCHILL
MM138-003 – Operator Manual
PrestoCHILL
MM138-003 – Operator Manual
PrestoCHILL
MM138-003 – Operator Manual
The time required to reach the set temperature (-40°C) from room temperature (approximate 20°C) varies from 40 minutes to 1 hour.
Before starting, wipe the work plate of the PrestoCHILL with paper or similar absorbent material to dry it.
PrestoCHILL
MM138-003 – Operator Manual
The time required to reach the set temperature (-40°C) from room temperature (approximate 20°C) varies from 40 minutes to 1 hour.
Before starting, wipe the work plate of the PrestoCHILL with paper or similar absorbent material to dry it.
For safety reasons, if the cover of the PrestoCHILL is open when the beginning of a chiller program is set, the chiller program does not start.
PrestoCHILL
MM138-003 – Operator Manual