Transition Networks NDM-FTX series
fast Ethernet dual media NIC (NetworkInterface Card) provides a 10/100BaseTX copper port and a 100Base-FX fiber
port for installation flexibility in a
mixed-media environment. The dual
ports can also provide redundancy for
critical applications. These NICs come in standard and low profile form factors, and
include driver support for a variety of operating systems.
Part NumberPort One - Copper
10/100Base-TX
NDM-FTX-ST-01
NDM-FTX-ST-01(L)
NDM-FTX-SC-01
NDM-FTX-SC-01(L)
NDM-FTX-MT-01
NDM-FTX-MT-01(L)
NDM-FTX-SC5-01
NDM-FTX-SC5-01(L)
NDM-FTX-SC20-01
NDM-FTX-SC20-01(L)
NDM-FTX-SB201-01
NDM-FTX-SB201-01(L)
NDM-FTX-SB202-01
NDM-FTX-SB202-01(L)
RJ-45
100 m (328 ft)*
RJ-45
100 m (328 ft)*
RJ-45
100 m (328 ft)*
RJ-45
100 m (328 ft)*
RJ-45
100 m (328 ft)*
RJ-45
100 m (328 ft)*
RJ-45
100 m (328 ft)*
Port Two - Duplex Fiber-Optic
100Base-FX
ST, 1300 nm multimode
2 km (1.2 miles)*
SC, 1300 nm multimode
2 km (1.2 miles)*
MT-RJ, 1300 nm multimode
2 km (1.2 miles)*
SC, 1310 nm single mode
5 km (3.1miles)*
SC, 1310 nm single mode
20 km (12.4 miles)*
SC, 1310 TX/1550nm RX single
mode, single fiber 20 km (12.4 miles)*
SC, 1550 TX/1310 nm RX single
mode, single fiber 20 km (12.4 miles)*
Optional accessories sold separately
Part NumberDescription
BTR-NDM-RPLRPL, Bootable ROM Chip
BTR-NDM-PXEPXE, Bootable ROM Chip
*Typical maximum cable distance.
Actual distance is dependent upon the
physical characteristics of the network
installation.
Before installing the NDM-FTX, verify that the package contains the following
items:
• NDM-FTX Board
• LAN Driver CD
Please notify your sales representative if any item is missing or damaged.
Description
The NDM-FTX module has a bootable ROM socket (ROM chip sold separately).
The two LED indicators, LINK/ACT and FDX located on the bracket, show
network/board link, activities, collision, and full-duplex statuses. See Figure 1.
Figure 1: LEDs and Boot ROM Socket
NDM-FTX module installation
CAUTION: Wear a grounding strap and observe electrostatic discharge
precautions when installing the NDM-FTX module. Failure to observe this caution
could result in damage or failure of the NDM-FTX module.
To install the NDM-FTX module, do the following:
Install the NDM-FTX module -- continued
5.Ensure that the module is firmly seated in the slot.
6.Use the screws from step “3” to secure the module to the workstation or
file server housing.
NDM-FTX PCI module configuration
For motherboards with automatic PCI configuration:
•No specific setup is needed.
•You can enter the system BIOS setup menu to view or specify the interrupt
(INT) line of the PCI slots.
For motherboards with bus master and interrupt jumpers:
•Enable bus master operation in a selected PCI slot and select an INT
request line (IRQ) level, using the appropriate motherboard jumper.
•Enable I/O on the NDM-FTX, PCI slot.
PCI bus system and configuration
•Ensure that the PCI machine supports master slots, INT multiple sharing
and timing compatibility.
•DO NOT install NDM-FTX in PCI slave slots. Please refer to your PCI
system manual and select the appropriate configuration settings.
•When installing multiple NDM-FTX boards in a server station, you should
correctly configure the IRQ settings of the PCI slot.
•Up to four NDM-FTX modules can be installed in a PCI file server
running NetWare operating system.
•NDM-FTX server modules share the same INT line with the driver
supporting multiple INT services at a time. The IRQ of each NDM-FTX
module should not conflict with other boards.
•Operation in full or half-duplex mode is configured by LAN driver
options. The operating mode should match the working status of the
remote link device.
•Use EMM386 version 4.49 or higher, and install both DOS and EMM386
from the same DOS package to avoid software problems.
Important: Install the NDM-FTX module in a “master slot” only.
1.Locate a master slot on the PC workstation or file server.
2.Remove the cover from the PC workstation or file server—keep all screws.
3.Remove and keep the screws holding the cover over the installation slot.
4.Carefully slide the NDM-FTX module into the “master slot,” aligning the
module with the slot guides.
NDM-FTX-SC5-01(x)1310 nm single mode
Fiber optic transmitter power:min: -19.0 dBmmax: -14.0 dBm
Fiber optic receiver sensitivity:min: -31.0 dBmmax: -7.5 dBm
Link budget:12.0 dB
NDM-FTX-SC20-01(x)1310 nm single mode
Fiber optic transmitter power:min: -15.0 dBmmax: -8.0 dBm
Fiber optic receiver sensitivity:min: -31.0 dBmmax: 0.0 dBm
Link budget:16.0 dB
NDM-FTX-SB201-01(x)1310 TX/1550 RX nm single mode
Fiber optic transmitter power:min: -14.0 dBmmax: -8.0 dBm
Fiber optic receiver sensitivity:min: -32.0 dBmmax: 0.0 dBm
Link budget:18.0 dB
1
2
3
6
single stand
Fiber cable -- continued
NDM-FTX-SB202-01(x)1550 TX/1310 RX nm single mode
Fiber optic transmitter power:min: -14.0 dBmmax: -8.0 dBm
Fiber optic receiver sensitivity:min: -32.0 dBmmax: 0.0 dBm
Link budget:18.0 dB
The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC825/CDRH standard and comply with 21CRF1040.10 and 21CRF1040.11.
single stand
Technical Specifications
For models NDM-FTX-xxxxx-01 and NDM-FTX-xxxxx-01(L)
Standards:IEEE 802.3
Expansion bus standard:PCI 2.1, 2.2
Data rate:10/100Mpbs twisted pair media
100Mbps fiber media
LED:LINK/ACT (on the bracket)
ON = communication link; flashing = activity on link
FDX (full duplex link); ON = full duplex link
Drivers:• NetWare Server 4.1x, 5.x
• Netware DOS Client ODI
• Windows 95, 98, 2000, 2003, XP, NT4.0
• Linux
Boot server support:Novell RPL Boot ROM; PXE Boot ROM
PCB dimensions:2.5” W x 5.9” D x 0.85” H
(63.5 mm W x 149.9 mm D x 21.6 mm H)
Weight:3 oz. (91g) approximate
Power consumption:1.0A @ +5VDC
MTBF198,853 hours (Bellcore7 V5.0)
Operating temp0°C to 50°C (32°F to 122°F)
Storage temp:-25°C to 85°C (-13°F to 185°F)
Humidity:5% to 90%, non-condensing
Altitude: 0 to 10,000 feet
Warranty:Lifetime
WARNING: Visible and invisible laser radiation when open: DO NOT stare into
the beam or view directly with optical instruments. Failure to observe this warning
could result in damage to your vision or blindness.
CAUTION:
than those specified herein may result in hazardous radiation exposure.
The information in this manual is subject to change without further notice.
Use of controls, adjustments, or the performance of procedures other
techsupport@transition.com -- Click the “Transition Now” link for live Web chat.
7
Page 5
Compliance Information
CISPR22/EN55022 Class A, CE Mark, CISPR22/EN55022 Class A + EN55024, CE Mark
FCC regulations
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at the user's own expense.
Canadian regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out
on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage
radioélectrique édicté par le ministère des Communications du Canada.
European regulations
Caution: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei
Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für
Gegenmaßnahmen verantwortlich.
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de
créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures
spécifiques appropriées.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EGMitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
Trademark notice
All registered trademarks and trademarks are the property of their respective owners.