Milan Technology MIL-S1600S User Manual

Page 1
MIL-S1600S User’s Guide
The MIL-S1600S switch is a sixteen port switch that can be used to build high-performance switched workgroup networks. This switch is a store-and-forward device that offers low latency for high-speed net­working. The MIL-S1600S switch has 16 auto-sensing 10/100Base­TX RJ-45 ports with auto MDI/MDIX and features a "store-and-for­ward " switching scheme. This allows the switch to auto-learn and store source address on an 8K-entry MAC address table. Auto MDI/MDIX allows connection to another switch or workstation without changing non-crossover or crossover cabling.
1
Page 2
Regulatory Approval
- FCC Class A
- UL 1950
- CSA C22.2 Number 950
- CE
EN55022 Class A EN55024
Canadian EMI Notice
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.
European Notice
Products with the CE marking comply with both the EMC Directive (89/336EEC) and the Low Voltage Directive (73/23EEC) issued by the commisions of the European Community. Compliance with these directives implies conformity to the following European norms:
- EN55022 (CISPR 22) - Radio Frequency Interference
- EN61000-X - Electromagnetic Immunity
Trademarks
The MiLAN logo and MiLAN Technology trademarks are registered trademarks of MiLAN Technology in the United States and/or other countries.
To Contact MiLAN Technology
For prompt response when calling for service information, have the following information ready:
- Product serial number and revision
- Date of purchase
- Vendor or place of purchase
You can reach MiLAN Technology technical support at:
- E-mail: support@milan.com
- Telephone: +1.408.744.2751
- Fax: +1.408.744.2771
MiLAN Technology 1329 Moffett Park Drive Sunnyvale, CA 94089 United States of America
Telephone: +1.408.744.2775 Fax: +1.408.744.2793
http://www.milan.com info@milan.com
© 2003 MiLAN Technology Technology Printed in USA P/N: 90000392 Rev. B
Five-Year Limited Warranty
MiLAN Technology warrants to the original consumer or purchaser that each of it's products, and all components thereof, will be free from defects in material and/or workmanship for a period of five years from the original factory shipment date. Any warranty hereunder is extended to the original consumer or purchaser and is not assignable.
MiLAN Technology makes no express or implied warranties including, but not limited to, any implied warranty of mer­chantability or fitness for a particular purpose, except as expressly set forth in this warranty. In no event shall MiLAN Technology be liable for incidental or consequential damages, costs, or expenses arising out of or in connection with the performance of the product delivered hereunder. MiLAN Technology will in no case cover damages arising out of the product being used in a negligent fashion or manner.
Cabling RJ-45 ports: Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: Category 3, 4 or 5 cable for 10Mbps connections or Category 5 cable for 100Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
Technical Specification
7
2
Page 3
Troubleshooting
This section is intended to help you solve the most common prob­lems on the MIL-S1600S switch.
Incorrect connections
Faulty or loose cables Look for loose or obviously faulty connections. If they appear to be OK, make sure the connections are snug. If that does not correct the problem, try a different cable.
Non-standard cables Non-standard and miswired cables may cause numerous network collisions and other network problem, and can seriously impair network performance. A category 5 cable tester is a recommended tool for every 100Base-T network installation.
Improper Network Topologies It is important to make sure that you have a valid network topology. You should make sure that your network topolo­gy contains no data path loops. Between any two-end nodes, there should be only one active cabling path at any time. Data path loops will cause broadcast storms that will severely impact your network performance.
Diagnosing LED Indicators
The switch can be easily monitored through panel indicators to assist in identifying problems, which describes common problems you may encounter and where you can find possible solutions.
If the power indicator does not turn on when the power cord is plugged in, you may have a problem with power cord. Check for loose power connections, power losses or surges at power outlet. If you still cannot resolve the problem, contact your local dealer for assistance.
Features
• Conforms to 802.3, 802.3u, and 802.3x standard.
• 16 auto-sensing 10/100Mbps Ethernet RJ-45 ports.
• Automatic MDI/MDIX crossover for 10Base-T and 100Base-TX ports.
• Auto-negotiation supported.
• Back-Pressure-Base flow control on Half-duplex ports.
• Pause-Frame-Base flow control on Full-duplex ports.
• Store-and-forwarding switching architecture for abnormal packet fil­tering.
• Full wire speed forwarding rate.
• 8K-entry MAC address table.
• LED-indicators for Power, Link/Active.
Package Contents
Unpack the contents of the MIL-S1600S switch and verify them against the checklist below.
• MIL-S1600S switch
• Power Cord
• User Guide
Compare the contents of your MIL-S1600S switch package with the standard checklist above. If any item is missing or damaged, please contact your local dealer for service.
6 3
Page 4
Hardware Description
Front Panel
The Front Panel of the MIL-S1600S switch consists of 16 10/100Base-TX RJ-45 ports The LED Indicators are also located on the front panel of the switch.
RJ-45 Ports (Auto MDI/MDIX): 16 10/100 auto-sensing for 10Base-T or 100Base-TX connections. (In general, MDI means con­necting to another hub or switch while MDIX means connecting to a workstation or PC. Therefore, auto MDI/MDIX means that you can connect to another switch or workstation without changing non­crossover or crossover cabling.)
LEDs Indicators
The LED Indicators gives real-time information of systematic opera­tion status. The following table provides descriptions of LED status and their meaning.
LED Status Description
Power Green Power On
Off Power is not connected
LK/ACT Green The port is connected with
operating device.
Blinks The port is receiving or
transmitting data.
Off No device attached.
4
Rear Panel
The 3-pronged power plug is located at the rear Panel of the MIL­S1600S switch as shown in Figure 2-2. The switch will work with AC in the range 100-240V AC, 50-60Hz
Desktop Installation
Set the switch on a sufficiently large flat space with a power outlet nearby. The surface where you put your switch should be clean, smooth, level and sturdy. Make sure there is enough clearance around the switch to allow attachment of cables, power cord and allow air circulation.
Power ON
Connect the power cord to the power socket on the rear panel of the switch. The internal power supply in the switch works with AC in the voltage range 100-240VAC, frequency 50~60Hz.
Check the power indicator on the front panel to see if power is prop­erly supplied.
5