Listed: UL 1482, ULC-S627 Solid Fuel Room Heater
PLEASE READ ALL INSTRUCTIONS BEFORE YOU INSTALL YOUR NEW STOVE.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
SAFETY NOTICE: FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE
OFFICIAL ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA. PLEASE CHECK WITH YOUR INSURANCE BEFORE
USING IN YOUR HOME. USE PROFESSIONAL INSTALLER.
C A U T I O N
Hot while in operation– do not touch
Contact may cause skin burns
Keep children and clothing away
Keep furnishing and other combustible materials
a considerable distance away from stove.
Do not overfire. If stove or chimney connector glows, you are overfiring
DO NOT INSTALL IN MOBILE HOME OR TRAILER
1
![](/html/16/16bd/16bd9cf9e39e4458d888779963583a24d4ff46ba3619b163942aa5088394c9aa/bg2.png)
SAFETY INSTRUCTIONS
Read all instructions carefully.
1. The installation of this stove must comply with your local building codes. Please observe
the clearance to combustible. Stove must be 18”(46 cm) from any combustible material,
wall, wood, furniture, paper, etc. Note: Drywall faced with bricks or stone should be consider a combustible surface.
2. Always connect this stove to a chimney and vent outside. This stove requires approved masonry or factory build 6” diameter UL 103 Type HT chimney, that is high enough to give
good draft.
3. Do NOT connect this stove to a chimney flue serving another appliance.
4. Be sure that your chimney is safely constructed and in good repair. Have chimney inspected
by the fire department or a qualified inspector.
5. Creosote or soot may build up in the chimney connector and chimney and may cause a
house or building fire. Inspect the chimney connector and chimney twice monthly during
the heating season and clean if necessary.
6. Burning any kind of fuel uses oxygen from the dwelling. Provide fresh air for proper combustion from outside the house into the room where the stove is located.
7. To prevent injury, do NOT allow anyone to use this stove who is unfamiliar with the correct
operation of the stove. Do not operate stove while under the influence of drugs or alcohol.
8. Flue connector pipe should be 6” diameter, minimum single wall 24 msg black or 25 msg
blued steel. (Listed to UL 103, Type HT and evaluated to CAN/ULC-S629-M87)
9. Do Not overfire. The special paint used on stove may give off some smoke and an odor
while they are curing during first few fires. Open windows and doors as needed to clear
smoke and odor. Overfiring may cause some damage to the stove.
10. Use only dry, seasoned, natural untreated wood. Do not burn garbage or flammable fluids,
such as gasoline, naphtha, kerosene or engine oil.
11. Use the metal ash drawer only to dispose of ashes. Dispose of ashes in a metal container
with a tight fitting lid. Keep the closed container on a non-combustible floor, well away
from all combustible materials. Keep ashes in the closed container until all cinders have
thoroughly cooled. The ashes may be buried in the ground or picked up by a refuse collector.
12. CAUTION: Hot while in operation. All person, especially young children should be alerted
and trained to stay a safe distance from the stove. Small children should be all the time carefully supervised when they are in the same room with the stove.
13. This stove requires non-combustible floor protection.
14. Keep stove area clear and free from all combustible materials such as gasoline and/or other
flammable vapors and liquids at minimum 36”.
15. Never leave an unattended woodstove burning on high.
16. It is highly recommended to install smoke and carbon monoxide detectors in the home when
installing a wood stove.
SAVE THESE INSTRUCTIONS
2
![](/html/16/16bd/16bd9cf9e39e4458d888779963583a24d4ff46ba3619b163942aa5088394c9aa/bg3.png)
INSTALLATION INSTRUCTION
CAUTION: STOVE IS HEAVY. MAKE SURE YOU HAVE ADEQUATE HELP AND
USE PROPER LIFTING TECHNIQUES WHENEVER MOVING STOVE.
1. Proper clearances must be maintained for adequate air circulation. Adequate ventilation
must be provided while operating this stove.
2. The stove must be placed on solid masonry, solid concrete, or when installing on combustible floor, on a UL 1618 listed floor protector. The base must extend at least 18” (46 cm) beyond the front of the stove and 8”(20 cm) to the sides, and MUST extend under the stove
pipe. (Check local building codes and fire protection ordinances.) Floor protector minimum
size; Royal 900 is 51.5”W by 49.5”D (1308 mm X 1257 mm ); Royal 720 is 44.5” W by
49.5”D ( 1130 mm X 1257 mm ).
3. The stove must have its own flue. DO NOT CONNECT THIS UNIT TO A CHIMNEY
SERVING OTHER APPLIANCES.
4. Connect flue collar to the stove and adapter . The crimped end of the stove pipe must be installed facing down to fit inside the adapter. Figure 1, page 13.
5. Use three (3) sheet metal screws at each joint of stove pipe and adapter to firmly hold stove
pipe together. Use 6” round black/blue stove pipe (Listed to UL 103, Type HT and evaluated to CAN/ULC-S629-M87) NOT galvanized pipe. DO NOT CONNECT THIS STOVE
TO ANY AIR DISTRIBUTUIN OR DUCT SYSTEM.
6. Slope any horizontal stove pipe upward toward the chimney at least 1/4 inch for each foot
of horizontal run.
7. You must have at least 18” of clearance between any horizontal pipe and ceiling.
8. The stove pipe must NOT extend to far into the chimney flue.
9. It is recommended that no more than two (2) 90 degree bends be used in the stove pipe installation.
10. Connect to 6” inspected masonry chimney or 6” UL Type HT listed chimney.
A PROFESSIONAL, LICENSED HEATHING AND COOLING CONTRACTOR SHOULD
BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF
THIS SOLID FUEL BURNING APPLIANCE.
MASONRY CHIMNEY
Before using an existing masonry chimney, clean the chimney, inspect the flue liner and make
any repair needed to be sure it is safe to use.
If connector stove pipe must go through a combustible wall before entering the masonry chimney, consult a qualified mason or chimney dealer. The installation must conform to local fire
codes, and NFPA 211.
Do NOT connect this stove into the same chimney flue as the fireplace or flue from another
stove. If there is a cleanout opening in the base of the chimney, close it tightly.
UL LISTED CHIMNEY
Carefully follow chimney manufacturer’s instructions. Us only a UL 103 Type HT Listed Residential Type and Building Heating Appliance Chimney. The top of the chimney must be at least
three (3) feet above the roof and be at least two (2) feet higher than any point of the roof within
ten (10) feet.
3
![](/html/16/16bd/16bd9cf9e39e4458d888779963583a24d4ff46ba3619b163942aa5088394c9aa/bg4.png)
Chimney connector systems and clearances
Chimney connector shall not pass through attic or roof space, closet or similar concealed space, or a floor,
or ceiling. When passage through a wall, or partition of combustible is desired, the installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment: