MikroTik D-5G-30D3-PA Quick Setup Manual

A*
B C
MikroTik Antenna D-5G-30D3-PA
Quick setup guide and warranty information
Package contents
D
G
MikroTik Antenna assembly preview
*The preview is valid if a MikroTik RB900 series outdoor device (sold separately) is installed.
MikroTIK Radio
back* front
Parabolic Dish Antenna Feed Feed Bracket Mounting Bracket Pole Clamp Case Holder RF Cable Self-Bonding Tape Slice M10x130 Bolt M6x20 Bolt M4x12 Bolt M4 Wing Nut M4 Serrated Washer M6 Nut M6 Washer M6 Spring Lock Washer M10 Square Washer M10 Jam Nut M10 Fender Washer M10 Spring Lock Washer M10 Nut
A B C D E F G H
I
J K L
M N O
P
Q
R S T
U
1 1 1 1 2 1 2 2 4
16
4 2
5 20 12 16
4
4
4
4
4
ITEM DESCRIPTION QTY
E F
KJ
M
O Q TR
N
P US
L
*Packed separately
Installation Guide
0. Items Required
• 10mm Wrench • 17mm Wrench • PH2 Screw Driver • This guide is written to be used with a MikroTik RB900 series outdoor device (sold separately) •
1. Install Mounting Bracket to Parabolic Dish
Polarization slant option available - see instruction on www.routerboard.com
Install Mounting Bracket [D] to Parabolic Dish [A] using: [J] M6x20 Bolt x 8 pcs; [O] M6 Washer x 8 pcs; [P] M6 Spring Lock Washer x 8 pcs; [N] M6 Nut x 8 pcs.
Important:
• Align Parabolic Dish [A] to get H/V polarization layout - see Figure 1.1 & 1.2 or +45°/-45° polarization layout - see Figure 1.2;
• M6 Nut [N] tightening torque must be approximately 5 Nm.
2. Install Antenna Feed
Install Antenna Feed [B] to Parabolic Dish [A] using: [C] Feed Bracket x 1 pc; [K] M4x12 Bolt x 4 pcs; [M] M4 Serrated Washer x 4 pcs.
Install grounding fasteners: [L] M6 Wing Nut x 1 pc; [M] M4 Serrated Washer x 1 pc.
Important:
• Antenna Feed [B] and Feed Bracket [C] must be aligned respectively to the hole in the Parabolic Dish [A] - see Fig. 2;
• M4x12 Bolt [K] tightening torque must be approximately 2 Nm.
3. Attach MikroTik Radio to Mounting Bracket
Attach a MikroTik RB900 series outdoor device to Case Holder [F] using: [-] M3x8 Bolt x 4 pcs (comes with MikroTik Radio) - see Fig. 3.1.
Attach Case Holder [F] to Mounting Bracket [D] by tting Case Holder’s hinges into the Back Plate’s ange - see Fig. 3.2. Secure Case Holder using: [L] M4 Wing Nut x 1 pc.
Important:
• M3x8 Bolt [-] tightening torque must be approximately 1.2 Nm.
4. Install RF Cables
Remove the cover from MikroTIK Radio and install the RF Cables [G]. Connect vertical polarization (arrow V) to CH0, horizontal (arrow H) to CH1 - see Fig. 4.1. Fig. 4.2 show cable install for +45°/-45° polarization layout.
Insulate the RF Cable [G] ends which are connected to Antenna Feed [B] by using: [H] Self-Bonding Tape Slice x 2pcs.
• Remove the plastic liner from both sides;
• Stretch the tape to 2/3 of its width;
• Apply half-lapped layers clockwise. The RF Cable [G] ends which are connected to MikroTik Radio are insulated by the cover.
Fit back the MikroTik Radio cover.
Important:
• RF Cables [G] connector tightening torque must be approximately 0.5 Nm.
FIG. 2
K M C A B
L
M3x8FL
FIG. 3.1
FIG. 3.2
D
FIG. 1.1
FIG. 1.3
ALIGNMENT FOR
+45°/-45° POL LAYOUT
ALIGNMENT FOR
H/V POL LAYOUT
FIG. 1.2
A
N P
O D J
H
V
H G
FIG. 4.1
B
FIG. 4.2
RF CABLE INSTALL
INSTRUCTION FOR
+45°/-45°
POLARIZATION LAYOUT
5. Install Pole Fasteners
Determine the pole diameter which MikroTik Antenna will be attached to.
• If the pole diameter is less than 60mm( 2.375”) use the hole pattern from Fig. 5.1 to install the M10x130 Bolts [I];
• If the pole diameter is 60 - 100mm (max) use the hole pattern from Fig. 5.2.
Install M10x130 Bolt [I] x 4 pcs using: [Q] M10 Square Washer x 4 pcs; [R] M10 Jam Nut x 4 pcs.
Important:
•M10 Jam Nut [R] tightening torque must be approximately 4 Nm.
6. Attach Antenna to Pole
MikroTik Antenna is design to t the pole diameter up to 100mm( 3.9”).
Attach MikroTik Antenna to pole as shown in Fig. 6 using: [E] Pole Clamp x 2 pcs; [S] M10 Fender Washer x 4 pcs; [T] M10 Spring Lock Washer x 4 pcs; [U] M10 Nut x 4 pcs.
Important:
• M10 Nuts [U] tightening torque must be approximately 25 Nm.
7. Adjust Azimuth
Loosen the fasteners on Mounting Bracket [D], which lock the azimuth angle.
Turn the horizontal Alignment Mechanism to precisely adjust the azimuth
- see Fig. 7.
After setting the azimuth, tighten rmly the corresponding fasteners on the Mounting Bracket [D].
Important:
• Use 10mm Wrench to turn Adjustment Mechanism;
• M6 Nuts [Q] tightening torque must be approximately 7 Nm.
IF POLE Ø < 60mm
IF POLE Ø > 60mm
R Q I
FIG. 5.3FIG. 5.2
FIG. 5.1
FIG. 6
ØMAX = 100mm
E S T
U
FIG. 7
TURN TO ADJUST AZIMUTH
LEFT
RIGHT
8. Adjust Elevation
Loosen the fasteners on Mounting Bracket [D], which lock the elevation angle.
Turn the vertical Alignment Mechanism to precisely adjust the elevation
- see Fig. 8.
After setting the elevation, tighten rmly the corresponding fasteners on the Mounting Bracket [D].
Important:
• Use 10mm Wrench to turn Adjustment Mechanism;
• M6 Nuts [Q] tightening torque must be approximately 7 Nm.
Copyright and Warranty information
Copyright MikroTikls SIA. This document contains information protected by copyright law. No part of it may be reproduced or transmitted in any form without prior written permission from the copyright holder. RouterBOARD, RouterOS, RouterBOOT and MikroTik are trademarks of MikroTikls SIA. All trademarks and registered trademarks appearing in this document are the property of their respective holders.
Hardware. MikroTik warrants all RouterBOARD series equipment for the term of twelve (12) months from the shipping date to be free of defects in materials and workmanship under normal use and service, except in case of damage caused by mechanical, electrical or other accidental or intended damages caused by improper use or due to wind, rain, re or other acts of nature.
To return failed units to MikroTik, you must perform the following RMA (Return Merchandise Authorization) procedure. Follow the instructions below to save time, eorts, avoid costs, and improve the speed of the RMA process.
1. If you have purchased your product from a MikroTik Reseller, please contact the Reseller company regarding all warranty and repair issues, the following instructions apply ONLY if you purchased your equipment directly from MikroTik in Latvia.
2. MikroTik does not oer repairs for products that are not covered by warranty. Exceptions can be made for: CCR1016-12G, CCR1016-12G-BU, CCR1036-12G-4S, RB1100, RB1100AH, RB1100AHx2, RB1200, RB600, RB600A and RB800 as a paid service (fees apply).
3. Out-of-warranty devices and devices not covered by warranty sent to Mikrotik will be returned to the sender at sender's cost. If the customer has not organized return of such rejected devices within 12 months from the day of arrival, MikroTik has the right to discard them.
RMA Instructions are located on our webpage here: http://rma.mikrotik.com
This document is provided “as is” without a warranty of any kind, expressed or implied, including, but not limited to, the implied warranty of merchantability and tness for a particular purpose. The manufacturer has made every eort to ensure the accuracy of the contents of this document, however, it is possible that it may contain technical inaccuracies, typographical or other errors. No liability is assumed for any inaccuracy found in this publication, nor for direct or indirect, incidental, consequential or other damages that may result from such an inaccuracy, including, but not limited to, loss of data or prots. Please report any inaccuracies found to support@mikrotik.com
UP
FIG. 8
TURN TO ADJUST ELEVATION
DOWN
Loading...