USER MANUAL|Ethos 70 - 130
Introduction
The Mikrofill Ethos Boiler you have purchased has been designed and manufactured in Britain and represents the very best in quality and performance,
This User Manual is designed to Guide you through the many user settings available to ensure optimum operating conditions. Please read this manual thoroughly, careful use of the controls will result in lower greenhouse gas emissions and reduced operating cost.
The Ethos range of boilers incorporate a fully integrated microprocessor control system that offers the following user settings
Heating Time Control Domestic Hot water Time Control (optional HWS sensor required) Weather Compensation (optional outside sensor required) Holiday period programming Night Set Back
The Optimised start facility is pre programmed and requires no user adjustment., all other settings and adjustments will have been factory set.
Any procedures not described in this user manual should only be undertaken by a competent qualified person, if in doubt contact Mikrofill technical dept. on 08452 606020
We recommend a regular maintenance regime that should include at least one annual service. Extended warranties inclusive of annual service are available from Mikrofill Systems Ltd. For fur ther details please contact the HELPLINE on 08452 606020.
2 User Manual
3 User Manual
BOILER MODULE
DHW selection button
Heating selection button
Show information
Settings accept
Chimney sweep function STB test
Manual mode
Adjust room comfort setpoint Navigation and settings
Service plug (BSB)
Quit setting
Heating to Comfort setpoint
Heating to Reduced setpoint
Heating to frost protection setpoint
Process running - please wait
Change battery
Burner operating
Info level activated
Programming activated
Heating temporarily switched off ECO function active
Holiday function active
Reference to heating circuit
Maintenance / special operation
Error messages
BOILER OPERATION
4 User Manual
Selecting heating module
This setting is used to switch between the different operating modes. The selection made is indicated by a bar which appears below the respective symbol.
Automatic mode
Automatic mode controls the room temperature according to the time program.
Characteristics of automatic mode:
Heating mode according to the time program Temperature setpoints according to heating program “Comfort setpoint“ or “Reduced setpoint“ Protective functions active Automatic summer / winter changeover (ECO functions)
Continuous operation or
Continuous operation or Continuous operation maintains the room temperature at the selected operating level.
Heating to Comfort setpoint Heating to Reduced setpoint
Characteristics of continuous operation:
Heating mode with no time program Protective functions active Automatic summer / winter changeover (ECO functions)
5 User Manual
BOILER OPERATION
Protection
When using protection, the heating system is off. But it remains protected against frost (frost protection temperature) provided there is no power failure. Characteristics of Protection:
Heating off
Temperature according to frost protection Protective functions active Automatic summer / winter changeover (ECO functions) and automatic 24-hour heating limit active
Selecting DHW heating mode
The button is used to switch DHW heating mode on and off. The selection made is indicated by a bar which appears below the respective symbol.
DHW heating
On
The DHW is heated according to the selected switching program.
Off No DHW heating, the protective function is active. Triggering is effected by keeping the DHW operating mode button on the operator or room unit depressed for at least 3 seconds. It can also be started when:
The operating mode is “Off“
Operating mode changeover acts via H1 or centrally (LPB)
All heating circuits use the holiday function
Adjusting the room temperature setpoint
Turn the setting knob to increase or decrease the Comfort setpoint For the Reduced setpoint
Press OK
Select operating page “Heating circuit“ and
Adjust the “Reduced setpoint“
If no external sensors are connected, the boiler flow temperature will be determined by using the heating curve with an external temperature of 0°C. Please see following graph for equivalent temperatures.
After each re-adjustment, wait at least 2 hours, allowing the room temperature to adapt.