SOLID STATE RELAY, 400VDC- 0.5A
OPTICALLY ISOLATED, SHORT CIRCUIT PROTECTED
MICROCIRCUITS DIVISION
Mii
Features:
SPST, Normally Open
1000VDC Optical Isolated Control Input
Power MOSFET, Low On-state Resistance
Built-in Short Circuit Protection
Wide Operating Temperature Range
Non-hermetic Package
Applications:
COTS Military Applications
Gun Turret Controls
Motor or Solenoid Driver
Displays/Lamps/Controls
Industrial Automation
DESCRIPTION
The 53262 Solid State Relay (SSR) is designed for applications in environment where hermeticity is not required. Its solid state “contact” is resistant to damage from shock and vibration. It is also immune to contact related problems (contamination, arcing, bouncing, etc.) associated with the electromechanical relays. Functionally, the device operates as a single-pole single-throw (SPST), normally open (1 Form A) unidirectional high-side or low-side switch. Using a 500VDC rated N-channel MOSFET as the switching device, the 53262 SSR offers low on-state resistance for lowering the power dissipation, which allows operation over the temperature range of –40°C to +85°C with minimal heat sinking. A built-in current sense circuit offers short circuit protection by turning off the MOSFET switch and allowing no current flow into the load. After the 53262 SSR tripped due to a short circuit load, the output latches in the off-state until its control input recycles. The control input is isolated from the load circuit using an optocoupler. This isolation barrier will eliminate the system ground loop noise of the application. The optocoupler employs a dual high efficiency LED input allowing TTL/CMOS logic to drive the solid state relay. The SSR is actuated by applying an input forward current of 5 to 10 mA to the LED’s. The 53262 SSR has no moving parts and is enclosed in a non-hermetic package.
ABSOLUTE MAXIMUM RATINGS (@ T
= 25°C unless otherwise specified)
C
Output Voltage 400 VDC Continuous Output Current @ T
= 85°C 1 A
C
Continuous Control Input Current 20 mA Storage Temperature Range -65°C to +150°C Operating Temperature Range -40°C to +85°C Junction Temperature 150°C Lead Solder Temperature 300°C for 10 s
RECOMMENDED OPERATING CONDITIONS
Parameter Symbol Min. Max. Units
Output Voltage V
Continuous Output Current I
Control Input Current IF 5 10 mA
Operating Case Temperature TC -40 85 °C
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
MICROPAC INDUSTRIES, INC.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
www.micropac.com
400 VDC
O (OFF)
0.5 A
O (ON)
MICROCIRCUITS DIVISION • 905 E. Walnut St., Garland, TX 75040 • (972) 272-3571 • Fax (972) 494-2281
E-MAIL: hybridsales@micropac.com 05/16/2002
Pg. 1 of 4
53262
Short Circuit Protected Solid State Relay
__________________________________________________________________________________________
ELECTRICAL SPECIFICATIONS
= -40°C to +85°C, unless otherwise specified.
T
C
Parameter Symbol Min. Typ.* Max. Unit
Test Conditions Notes
s
INPUT CHARACTERISTICS
Input Forward Voltage VF 2.0 2.7 3.8 VDC IF = 8 mA
Input Reverse Breakdown Voltage VR 6 20
OUTPUT CHARACTERISTICS
Output On-Resistance R
(ON)
0.8 1.2
VDC
I
= 10 µA
R
= 8 mA, IO = 0.5 A
I
F
Pulse width = 10 ms Duty cycle 10%
= 0.6 VDC
V
Output Leakage Current I
Turn-On Time tON
Turn-Off time t
Rise Time t
Fall Time t
O (OFF)
OFF
R
F
Over-current Limit ICL 1.1
Over-current Trip Time tCL
250
µA
8 ms
2 ms
6 ms
1 ms
4.5 A
1 ms
F
= 400 VDC
V
O
= 8 mA
I
F
= 0.5 A
I
O
Pulse width = 10 ms Duty cycle 10%
V
= 54 VDC
O
R
= 12
L
3 &
Figure 2
7
6
6
4
Peak Short Circuit Current I
Short Circuit Shut Down Time tSC
COMMON CHARACTERISTICS
SC(PK)
15 20 A
100
µs
Short-while-on @ T
= 25°C
C
5 & 7
RH 45%, t = 5 s
Input-Output Leakage Current I
Thermal Resistance (junction-case)
* Typical values are at TC = 25°C
I-O
θ
JC
18.5
1
µA
V
= 1000 VDC
I-O
= 25°C
T
C
°C/W 7
1 & 2
Notes:
1. Input pins shorted together and output pins shorted together.
2. Input -output potential applied momentarily, not a steady state operating condition.
3. Rise time is measured from 10% to 90% of load current (90% to 10% of V 10% of load current (10% to 90% of V
). Guaranteed but not tested.
O
). Fall time is measured from 90% to
O
4. The minimum over-current limit occurs at Tc of 85°C. The maximum over-current limit occurs at Tc of -40°C.
5. Use 0.25 ohm sense resistor for monitoring the peak short circuit current.
6. The user should apply the appropriate transient suppression technique to the output terminals of the relay when the loads are inductive enough to generate voltage spikes.
7. Guaranteed but not tested.
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
MICROPAC INDUSTRIES, INC.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROCIRCUITS DIVISION • 905 E. Walnut St., Garland, TX 75040 • (972) 272-3571 • Fax (972) 494-2281
www.micropac.com
E-MAIL: hybridsales@micropac.com 05/16/2002
Pg. 2 of 4
Loading...
+ 2 hidden pages