Migatronic RWF 30 User Manual

BRUGSVEJLEDNING
USER GUIDE
BETRIEBSANLEITUNG
GUIDE DE L’UTILISATEUR
BRUKSANVISNING
GUIDA PER L’UTILIZZATORE
GEBRUIKERSHANDLEIDING
RWF 30
50115057 Valid from 2018 week 37
2
Dansk ..................................................................3
English ................................................................7
Deutsch ............................................................. 11
Français ............................................................. 15
Svenska ............................................................. 19
Italiano .............................................................23
Nederlands .......................................................27
Polski .................................................................31
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S Aggersundvej 33 9690 Fjerritslev Denmark
hereby declare that our machine as stated below Type: RWF 30
conforms to directives: 2014/35/EU 2014/30/EU 2011/65/EU
European standards: EN/IEC60974-5 EN/IEC60974-10 (Class A)
Issued in Fjerritslev 01.03.2018
Niels Jørn Jakobsen
CEO
3
Tilslutning og ibrugtagning
Advarsel
Læs advarsel og brugsanvisning omhyggeligt igennem inden installation og ibrugtagning og gem til senere brug.
Tilslutning
1. Tilslutning af trykluft AIR Clean - Indgang
2. Tilslutning af trykluft AIR Clean - Udgang
3. CAN-stik
4. Tilslutning af gas
5. Power +
6. Tilslutning køleslange (ikke alle modeller)
- fremløb (blå)
- tilbageløb (rød)
7. Status-indikator
8. Trådindløb
9. Slangetilslutning
10. Kollisionsbeskyttelsessignal til robot controller
11. Brænderkollisionsbeskyttelse og “touch sense” forbindelse
Vigtigt!
Når stelkabler og mellemkabler tilsluttes maskinen, er god elektrisk kontakt nødvendig, for at undgå at stik og kabler ødelægges.
Anbefalede kabelstørrelser
Svejsestrøm DC PULS
200 A 35 mm² 35 mm² 300 A 50 mm² 70 mm² 400 A 95 mm² / 2x50 mm² 95 mm² / 2x50 mm² 550 A 2x70 mm² 2x70 mm²
Svejseproces Afstand til
arbejdsemne
(a+b)
Total kabellængde
i svejsekredsløb
(a+b+c)
MIG - IAC og puls 10 m 20 m MIG - ingen puls 30 m 60 m
2
1
3
4
8
9
10
11
7
6
6
5
c
a
b
ADVARSEL
Når der trykkes på svejseslangens kontakt/tast, er der spænding på svejsetråden.
4
Tilslutning og ibrugtagning
RWF30 leveres driftsklar og færdigkonfigureret til anvendelse med SIGMA SELECT i både standard- og robot-løsninger.
Der er mulighed for at koble op til 3 stk RWF30 enheder på samme svejsemaskine.
Rangering af tråd frem/retur
Når der ikke svejses, kan rangering af tråd startes ved tryk på en af tasterne eller fra robotinterface, hvis RWF30 anvendes i en robotløsning.
IGC (Intelligent Gas Control)
RWF30 leveres standard med IGC, der sikrer dynamisk regulering af flowmængden i forhold til svejseopgave. Gastilførslen skal indstilles til 2-6 bar.
Kalibrering af IGC-flowet skal foretages fra fjern­betjening (nærmere beskrivelse kan ses i strømkildens brugsvejledning).
Gastest
Gastest-funktionen (test af gasflow) kan aktiveres fra evt. robotinterface eller ved at trykke på gastest­tasten fra fjernbetjening (nærmere beskrivelse kan ses i strømkildens brugsvejledning).
Statusindikator (7)
• Slukket lysdiode: RWF er ikke aktiv. Aktivér RWF via robotinterface eller tilkoblet brænder.
• Blinkende lysdiode: RWF er aktiv men har ingen CAN-forbindelse til strømkilde. Efterse CAN­forsyningskabel og -stik.
• Tændt lysdiode: RWF er aktiv.
AIR Clean (luftrens) (1+2)
Der er mulighed for tilslutning af trykluft til brug for rensning af gasdysen, hvis RWF anvendes i løsning med integreret robotinterface. Trykluften skal indstilles og styres via robotinterfacet.
TOUCH Sensing (11)
System til positionsbestemmelse, hvis RWF anvendes i løsning med integreret robotinterface. Touch sensing funktionen anvender svejsetråd eller dyse til at danne elektrisk kontrakt, hvorefter robotten automatisk justerer svejsepositionen før lysbuetænding.
Kollisionsbeskyttelse til robot controller (10)
Signal til kollisionsbeskyttelse muliggør tilkobling af mekanisk sikring på robotbrænderen. Denne forhindrer, at brænderen kommer ud af kalibrering ved sammenstød med et emne. Funktionen kan kun anvendes, hvis RWF anvendes i løsning med integreret robotinterface.
Nærmere beskrivelse af TOUCH sensing og Kollisionsbeskyttelse kan ses i SIGMA SELECT Robo manualen (varenr. 50115056).
RWF 30
Til robotcontroller Til kollisionssensor &
touch sensor
Kollisionssignal
24V
0V
1K 50WΩ
Relæ til
detektering af
brændergasdyse
ZA
Svejsning +
fra strømkilde
Til RWF 30 kollisionssensor
og touch sensor
Kollisions­sensor
Signal til detektering af brænder­gasdyse
Han
1
2
3
Hun
1
2
3
7
Han
1
2
3
7
Han
1
2
3
a
b
c
Brænder
ABICOR BINZEL
ledningsføring a = grøn b = hvid c = brun
KollisionsbesKyttelsessignal til RobotcontRolleR
Pin 1: 0V fra robotcontroller Pin 2: +24V fra robotcontroller Pin 3: kollisionssignal til robotcontroller
KollisionsbesKyttelsessignal og
touch sense til bRændeR
Pin 1: 0V til kollisionssensor Pin 2: +24V til kollisionssensor Pin 3: kollisionssignal fra kollisionssensor Pin 7: touch sense-forbindelse til gasdyse
5
Tilslutning og ibrugtagning
Fejlhåndtering
Kølefejl
Kølefejl vises i tilfælde af at kølevandet ikke kan cirkulere som følge af forkert tilslutning eller tilstopning. Kontroller at køleslangerne er korrekt tilsluttet, efterfyld vandbeholderen og efterse svejseslange og tilslutningsstudser. Kølefejlen afmeldes med et kort tryk på P-knappen.
Gasfejl (IGC)
Gasfejl kan skyldes for lavt eller for højt tryk på gastilførslen. Kontroller at trykket på gastilførslen er højere end 2bar og mindre end 6 bar, svarende til højere end 5 l/min og mindre end 27 l/min. Gasfejl kan sættes ud af funktion ved at indstille manuel gasflow til 27 l/min. Gasfejlen afmeldes med et kort tryk på P-knappen.
Tekniske data
Intermittens 100% 40°C, A 430
Intermittens 60% 40°C, A Intermittens maks. 40°C, A 550 Trådhastighed, m/min 0,5-30,0 Brændertilslutning EURO Tråddimension, mm 0,6-1,6 Gastryk maks., MPa (bar) 0,6 (6,0) Touch Sense max. spænding, V 100 Touch Sense max. strøm, mA 100 Trykluft max. MPa (bar) 0,8 (8,0) Dimensioner (HxBxL), mm 240x220x308 Normer IEC60974-5,
IEC60974-10 CL. A
Vægt, kg 6,8
1
Beskyttelsesklasse IP23
Software
Hvis kontrolprintet udskiftes er det nødvendigt at lægge software ind i det nye print, ved hjælp af et SD kort. Nyeste software kan downloades på www.migatronic.com
Softwaren skal gemmes på et SD kort, som skal indeholde mapperne og én eller flere af filerne som vist herunder.
SD-kort kan bestilles på varenummer 78861297.
Software opdatering
• Indsæt SD-kortet
• Tænd maskinen
• Vent indtil enheden indikerer, at opdatering er afsluttet
• Sluk maskinen og tag SD-kortet ud
• Maskinen er nu klar til brug
1) Angiver at maskinen er beregnet for såvel indendørs som
udendørs anvendelse
MIGA_SW
SIGMA
10003664.cry
(control software package)
220
240
265
42,5
6
7
Connection and operation
Warning
Read warning notice and instruction manual carefully prior to initial operation and save the information for later use.
Connection
1. Compressed air connection AIR Clean - Inlet
2. Compressed air connection AIR Clean - Outlet
3. CAN-plug
4. Gas connection
5. Power +
6. Connection of cooling hose (not all models)
- flow (blue)
- return (red)
7. Status indicator
8. Wire inlet
9. Torch connection
10. Collision protection signal to robot controller
11. Torch collision protection and touch sense connection
Important!
In order to avoid destruction of plugs and cables, good electric contact is required when connecting earth cables and intermediary cables to the machine.
Recommended cable dimensions
Welding current DC PULSE
200 A 35 mm² 35 mm² 300 A 50 mm² 70 mm² 400 A 95 mm² / 2x50 mm² 95 mm² / 2x50 mm² 550 A 2x70 mm² 2x70 mm²
Welding process Distance to
work piece
(a+b)
Total cable length
in welding circuit
(a+b+c)
MIG - IAC and pulse 10 m 20 m MIG - non pulse 30 m 60 m
2
1
3
4
8
9
10
11
7
6
6
5
c
a
b
WARNING
When you activate the torch trigger, there is voltage applied to the welding wire.
8
Connection and operation
Male
1
2
3
Female
1
2
3
7
Male
1
2
3
7
Male
1
2
3
a
b
c
To robot controller To collision sensor &
touch sensor
Collision signal
24V
0V
1K 50WΩ
Torch gas nozzle sense relay
ZA
Welding +
from power source
To RWF 30 collision
sensor & touch sensor
Collision sensor
Torch gas nozzle sense signal
Torch
ABICOR BINZEL wiring
a = green b = white c = brown
The RWF30 unit is supplied ready for use with SIGMASELECT in both standard and robotic setups.
It is possible to connect up to three RWF30 units to a welding machine/power source.
Wire inching forward/return
When idling, wire inching can be activated by pressing one of the keys or activated at the robot interface, if the RWF30 unit is used in a robot setup.
IGC (Intelligent Gas Control)
The RWF30 unit is supplied with IGC, a function for dynamic flow rate adjustment according to welding job. Set the gas flow at 2-6 bar.
Calibrate the IGC flow at the remote control unit (see user guide for detailed description).
Gas test
The gas flow test function can be activated at the robot interface or by pressing the gas test key on the remote control unit (see user guide for detailed description).
Status indicator (7)
• LED off: RWF is not active. Use robot interface or connected torch to activate the RWF unit.
• Flashing LED: RWF is active but not CAN-connected to the power source. Check the CAN-mains cable and mains plug.
• LED on: RWF is active.
AIR Clean (1+2)
If the RWF unit is used along with an integrated robot interface, it is possible to connect a compressor unit for cleaning the gas nozzle. Set the compressed air and use the robot interface for control.
TOUCH Sensing (11)
For welded seam localization; this function is applicable if the RWF unit is used in an integrated robot interface setup and uses welding wire or a contact tip to create electrical contact. The robot automatically adjusts the welded seam position prior to arc ignition.
Collision protection for robot controller (10)
The collision protection function enables connection of a mechanical fuse to the robot torch. This prevents the torch from getting out of calibration in case of collision with a workpiece. The function is only applicable if the RWF unit is used in an integrated robot interface setup.
For more information about TOUCH Sensing and Collision protection, please refer to the SIGMA SELECT Robo manual (50115056).
RWF 30
collision pRotection signal to Robot contRolleR
Pin 1: 0V from robot controller Pin 2: +24V from robot controller Pin 3: collision signal to robot controller
collision pRotection signal and
touch sense to toRch
Pin 1: 0V to collision sensor Pin 2: +24V to collision sensor Pin 3: collision signal from collision sensor Pin 7: touch sense connection to gas nozzle
9
Connection and operation
Error handling
Torch cooling fault
Cooling fault is indicated on machines in case of insufficiant circulation of the cooling liquid due to faulty connection, defective parts or choking. Check that the cooling hoses are correctly connected, top up the water tank and check welding hose and branches. The cooling fault is cancelled by pressing shortly on the P-key pad.
Gas control fault (IGC)
Gas fault exists due to a to low or high gas flow. Make sure that the pressure on the gas flow is higher than 2 bar and less than 6 bar, corresponding to higher than 5 l/min and less than 27 l/min. The fault is disconnected by adjusting the manual gas flow to 27 l/min. The gas fault is reset by a short pressure on the P-key pad.
Technical data
Duty cycle 100% 40°C, A 430
Duty cycle 60% 40°C, A Duty cycle max. 40°C, A/% 550 Wire feed speed, m/min 0.5-30.0 Torch connection EURO Wire diameter, mm 0.6-1.6 Gas pressure max., MPa (bar) 0.6 (6.0) Touch Sense max. voltage, V 100 Touch Sense max. current, mA 100 Compressed air max., MPa (bar) 0.8 (8.0) Dimensions (HxWxL), mm 240x220x308 Standards IEC60974-5.
IEC60974-10 CL. A
Weight, kg 6.8
1
Protection class IP23
Software
In case of exchange of the control PCB, software must be reloaded, using an SD card. Latest software can be downloaded at www.migatronic.com
Save the software on an SD card containing the folders and one or more of the files shown below.
To order SD card, use item no 78861297.
Software update
• Insert the SD-card
• Turn on the machine
• Wait until the unit indicates that the update is complete
• Turn off the machine and remove the SD card
• The machine is now ready for use
1) Equipment marked IP23 is designed for indoor and outdoor
applications.
MIGA_SW
SIGMA
10003664.cry
(control software package)
220
240
265
42,5
10
11
Anschluss und Inbetriebnahme
Warnung
Lesen Sie die Warnhinweise und Betriebsanleitung sorgfältig vor der Inbetriebnahme und speichern Sie die Information für den späteren Gebrauch.
Anschluss
1. Anschluss des Drucklufts AIR Clean - Eingang
2. Anschluss des Drucklufts AIR Clean - Ausgang
3. CAN-Stecker
4. Gasanschluss
5. Power +
6. Anschluss der Brennerkühlung (nicht alle Modelle)
- Vorlauf (blau)
- Rücklauf (rot)
7. Status-Indikator
8. Drahteinlauf
9. Brenneranschluss
10. Kollisionsschutzsignal zur Robotersteuerung
11. Brennerkollisionsschutz und Touch Sensing-Anschluss
Wichtig!
Beim Anschluss der Masse- und Zwischenkabel an der Maschine ist guter elektrischer Kontakt erforderlich, zur Vermeidung der Zerstörung der Stecker und Kabel.
Empfohlene Kabelgrößen
Schweißstrom DC PULS
200 A 35 mm² 35 mm² 300 A 50 mm² 70 mm² 400 A 95 mm² / 2x50 mm² 95 mm² / 2x50 mm² 550 A 2x70 mm² 2x70 mm²
Schweißprozess Abstand zum
Werkstück
(a+b)
Gesamtkabellänge
im Schweißkreislauf
(a+b+c)
MIG - IAC und Puls 10 m 20 m MIG - ohne Puls 30 m 60 m
2
1
3
4
8
9
10
11
7
6
6
5
c
a
b
WARNUNG
Bei Betätigung des Brennertasters liegt Spannung an dem Schweißdraht an.
12
Anschluss und Inbetriebnahme
Die RWF 30-Einheit wird einsatzbereit und fertig­konfiguriert zum Gebrauch mit der SIGMA SELECT in sowohl Standard- als auch Roboter-Ausführungen geliefert
Bis zu drei RWF 30-Einheiten lassen sich an einer Schweißmaschine/Stromquelle anschließen.
Drahtförderung vorwärts/zurück
Wenn nicht geschweißt wird, lässt die Drahtförderung sich durch Betätigung einer der Tasten oder von der Roboter-schnittstelle aus aktivieren, falls die RWF30-Einheit in einer Roboterlösung eingesetzt wird.
IGC (Intelligente Gassteuerung)
Die RWF 30-Einheit wird standardmäßig mit IGC geliefert, einer Funktion zur dynamischen Steuerung der Gasdurchflussmenge je nach der aktuellen Schweißaufgabe. Den Gasdurchluss auf 2-6 bar einstellen.
Die Kalibrierung des Gasdurchflusses vom Fernregler aus vornehmen (siehe ausführliche Beschreibung in der Betriebsanleitung)
Gastest
Die Gasdurchfluss-Testfunktion lässt sich auf der Roboterschnittstelle oder durch Betätigung der Gastest-Taste auf dem Fernregler aktivieren (siehe aus­führliche Beschreibung in der Betriebsanleitung).
Status-Anzeige (7)
• LED aus: die RWF-Einheit ist nicht aktiv. Die RWF­Einheit mittels der Roboterschnittstelle oder des angeschlossenen Schweißbrenners aktivieren.
• Blinkende LED: die RWF-Einheit ist aktiv, hat aber keinen CAN-Anschluss an die Stromquelle. Das CAN-Netzkabel und den Netzstecker prüfen.
• LED ein: die RWF-Einheit ist aktiv.
AIR Clean (Luftreinigung) (1+2)
Falls die RWF-Einheit in einer Lösung mit einer integrierten Roboter-schnittstelle eingesetzt wird, lässt sich eine Druckluftanlage zur Reinigung der Gasdüse anschließen. Die Druckluft einstellen und mittels der Roboterschnittstelle regeln.
TOUCH Sensing (11)
Funktion zur Lokalisierung der Schweißnaht, falls die RWF-Einheit in einer Lösung mit einer integrierten Roboterschnittstelle eingesetzt wird. Die Funktion erzeugt mittels einer Schweißelektrode oder einer Stromdüse den elektrischen Kontakt. Danach justiert der Roboter automatisch die Schweißnahtposition vor Lichtbogenzündung.
Kollisionsschutz der Robotersteuerung (10)
Die Kollisionsschutz-Funktion ermöglicht den Anschluss einer mechanischen Sicherung an den Roboter-Schweißbrenner. Dies verhindert, dass der Schweißbrenner außer Kalibrierung kommt, im Falle einer Kollision mit einem Werkstück. Die Funktion ist nur anwendbar, wenn die RWF-Einheit in einer Lösung mit einer integrierten Roboterschnittstelle eingesetzt wird.
Nähere Beschreibungen der Touch Sensing- (Berührungssensor) und Kollisionsschutz-Funktionen sind der Sigma Select Robo­Bedienungsanleitung (50115056) zu entnehmen.
RWF 30
Zur
Robotersteuerung
Zum Kollisionssensor &
Touch Sensor
Kollisionssignal
24V
0V
1K 50WΩ
Brennergasdüse-
Sensorrelais
ZA
Schweißen + von
der Stromquelle aus
Zum RWF 30 Kollisionssensor
und Touch Sensor
Kollisions­sensor
Brenner­gasdüse­Sensorsignal
1
2
3
1
2
3
7
1
2
3
7
männlich
1
2
3
a
b
c
ABICOR BINZEL
Verdrahtung a = grün b = weiss c = braun
Brenner
männlich
weiblich
männlich
Kollisionsschutzsignal zuR RoboteRsteueRung
Pin 1: 0V Von der robotersteuerung aus Pin 2: +24V Von der robotersteuerung aus Pin 3: kollisionssignal zur robotersteuerung
Kollisionsschutzsignal und touch sense zum bRenneR
Pin 1: 0V zum kollisionssensor Pin 2: +24V zum kollisionssensor Pin 3: kollisionssignal Vom kollisionssensor aus Pin 7: touch sense-anschluss zur gasdüse
13
Anschluss und Inbetriebnahme
Fehlerhandhabung
Kühlungsfehler
Kühlungsfehler wird angezeigt auf Geräte, falls der Kühlkreislauf unterbrochen oder der Kühlmitteldurchfluss zu gering ist. Kontrollieren Sie bitte, dass die Kühleinheit korrekt angeschlossen ist und der Wasserbehälter ausreichend gefüllt ist. Überprüfen Sie den Schweißbrenner und die Wasserkühlanschlüsse. Durch kurzes Drücken auf die
P
-Taste wird der Kühlungsfehler abgemeldet.
Gasfehler (IGC)
Die Gasmenge ist zu gering oder zu groß. Kontrollieren Sie bitte, dass die Gaszufuhr höher als 2bar und weniger als 6 bar ist, d.h. höher als 5 l/min und weniger als 27l/min. Gasfehler wird außer Tätigkeit gesetzt, wenn der manuelle Gasfluß zu 27 l/min eingestellt wird. Der Gasfehler wird durch kurzen Drücken auf die
P
-Taste abgemeldet.
Technische Daten
Zulässige ED 100% 40°C, A/% 430
Zulässige ED 60% 40°C, A/% Zulässige ED max. 40°C, A/% 550 Drahtvorschubgeschwindigkeit, m/min 0,5-30,0 Brenneranschluss EURO Drahtdurchmesser, mm 0,6-1,6 Höchstgasdruck, MPa (bar) 0,6 (6,0) Touch Sense max. Spannung, V 100 Touch Sense max. Strom, mA 100 Drückluft max., MPa (bar) 0,8 (8,0) Maße (HxBxL), mm 240x220x308 Norm IEC60974-5,
IEC60974-10 CL. A
Gewicht, kg 6,8
1
Schutzklasse IP23
Software
Beim Austausch der Kontrollplatine muss neue Software mittels einer SD-Karte in der neuen Einheit eingelesen werden. Neue Software kann auf www.migatronic.com heruntergeladen werden.
Die Software muss auf eine SD-Karte mit den unten angezeigten Ablagen und einer oder mehreren der unten angezeigten Dateien gespeichert werden.
SD-Karte Bestellnummer: 78861297.
Software Einlesen
• Die SD-Karte einsetzen
• Die Maschine einschalten
• Warten Sie, bis angezeigt wird, dass das Update abgeschlossen ist
• Die Maschine ausschalten und die SD-Karte entfernen
• Die Maschine ist einsatz­bereit
1) Geräte, die der Schutzklasse IP23 entsprechen, sind für den
Innen-und Außeneinsatz ausgelegt.
MIGA_SW
SIGMA
10003664.cry
(control software package)
220
240
265
42,5
Loading...