Miele professional PG 8130, PG 8131, PG 8132, PG 8133 Installation Instructions

Installation plan
PG 8130 PG 8131 PG 8132 PG 8133
It is essential to read the operating instructions and service documents before installation or use of this appliance. This will prevent both personal injury and damage to the machine.
en - AU, NZ
Installation notes
2 PG 8130 / PG 8131 / PG 8132 / PG 8133
Please read and observe the operating instructions and the service documents regarding installation and setting up of this dishwasher.
Installation requirements
This dishwasher must be installed by a suitably qualified person with the appropriate electrical and plumbing qualifications in
accordance with the installation instructions supplied. This dishwasher must be installed in accordance with all applicable standards and guidelines, including legal requirements and health and safety regulations. The machine must be commissioned and operatives trained in its use by Miele Professional Service or by an authorised Miele Service Partner only.
Electrical connection
Connection to the electrical supply must be in accordance with valid legal requirements, health and safety regulations, and applicable standards. The mains connection cable must be protected from the risk of thermal damage. We recommend connecting the dishwasher to the power supply via a suitable plug and socket as this will make it easier to carry out the electrical safety test during commissioning and after any service work. For hard-wired dishwashers, connection must be via a main switch to be provided on site, which must completely isolate the machine from the power supply with a contact gap of at least 3mm. The plug, socket, and main switch must be easily accessible once the dishwasher has been installed.
Equipotential bonding and earthing
For added safety, the dishwasher should be protected with a residual current device with a trip current of 30mA. Equipotential bonding should be carried out if required. The screw
connection point for equipotential bonding is located at the back of the dishwasher. Equipotential bonding and earthing must be carried out before the machine is commissioned.
Water connection
This appliance must be installed according to AS/NZS3500.1. This appliance has been supplied with a separate backflow prevention device (non-return valve) and must be connected to the water tap.. The tap for the water supply must be easily accessible.
The dishwasher can be connected to either a cold water or hot water supply.
Environmental requirements
Condensate can build up in the area surrounding the dishwasher.
Any cabinetry and fittings in the room must therefore be suitable for purpose. If the machine is fitted under a suitable worktop (built-under and integrated models), the stainless steel steam deflector plate provided must be fitted above the door aperture to protect the worktop from moisture damage. A matching steam deflector plate is also available for order at a later date from Miele Professional Service.
Installation notes
PG 8130 / PG 8131 / PG 8132 / PG 8133 3
Connecting an external dispensing system
A dispensing system for liquid detergent and rinse aid can be connected at the back of the machine.
Illustrations
4 PG 8130 / PG 8131 / PG 8132 / PG 8133
PG 8130-31 dimensions
PG 8132-33 XXL dimensions
Illustrations
PG 8130 / PG 8131 / PG 8132 / PG 8133 5
Connections at the back of the machine
On-site connections
KW/WW Connection to cold or hot water EL Electrical connection
AW Drain connection PA Equipotential bonding
DS External dispensing
Illustrations
6 PG 8130 / PG 8131 / PG 8132 / PG 8133
Machine versions
PG 8130 freestanding model
PG 8130 U
PG 8130 U/i PG 8130i / PG 8131i
PG 8132 SCi XXL
PG 8133 SCVi XXL
Technical data
PG 8130 / PG 8131 / PG 8132 / PG 8133 7
Electrical connection for PG 8130
Voltage (standard delivered) AC 230V/50Hz
Total rated load 3.1kW
Fuse rating 1 x 15A
Mains connection cable, min. cross-section 3 x 1.5mm²
Length of mains connection cable with plug SAA/3/25 Typ HPM 106/5 2.4m
Voltage (convertible) AC 230V/50Hz
Total rated load 2.3kW
Fuse rating 1 x 10A
Mains connection cable, min. cross-section 3 x 1.5mm²
Length of mains connection cable with plug SAA/3/25 Typ HPM 106/5 2.4m
Electrical connection for PG 8131, PG 8132 and PG 8133
Voltage (standard delivered) AC 230V/50Hz
Total rated load 2.3kW
Fuse rating 1 x 10A
Mains connection cable, min. cross-section 3 x 1.5mm²
,
Length of mains connection cable with plug SAA/3/25 Typ HPM 106/5 2.4m
Voltage (convertible) AC 230V/50Hz
Total rated load 5.3kW
Fuse rating 1 x 25A
Mains connection cable, min. cross-section 3 x 4mm²
Length of mains connection cable with plug SAA/3/25 Typ HPM 106/5 2.4m
Water connection
Max. temperature 60°C
Max. water hardness 6.5 mmol/l
36°dH
On-site water pressure 50 - 1000kPa
Recommended flow pressure 200kPa
On-site threaded union in accordance with AS3688 (flat sealing) 3/4inches
Length of cold water inlet hose 1.5 m
Technical data
8 PG 8130 / PG 8131 / PG 8132 / PG 8133
Drain water
Drain water temperature 75°C
Standard length of drain hose 1.5 m
Max. drainage length of drain hose 4.0 m
Max. drain pump head height from bottom edge of machine 1.0 m
Max. transient flow rate 16l/min
Hose sleeves to be provided on site (ext. dia.xl) 22 x 30 mm
Internal diameter of drain hose 22 mm
Machine feet
Machine feet height adjustment 65 mm
Diameter of machine feet 30 mm
Insert for machine feet, size of thread 20 mm
Machine data
Height including lid PG 8130 845 mm
Building-under height PG 8130 / PG 8131 805 mm
Building-under height PG 8132 XXL / PG 8133 XXL 845 mm
Width PG 8130 freestanding model 600 mm
Width without lid 598 mm
Depth PG 8130 freestanding model 600 mm
Depth without lid 570 mm
Door height PG 8130 freestanding model 720 mm
Door height PG 8130-31 650 mm
Door height PG 8132-33 XXL 690 mm
Weight PG 8130 freestanding model 61.5kg
Weight PG 8130 U 54.0kg
Weight PG 8130i / PG 8131i 54.7kg
Weight PG 8132 SCi XXL 56.2kg
Weight PG 8133 SCVi XXL 56.0kg
Floor load in operation 1000 N
Min. access width incl. transport pallet 670 mm
Min. access depth including transport pallet 690 mm
Min. access height including transport pallet 970 mm
Noise level in dB (A), sound power pressure LpA during cleaning and drying phases (ECO programme) 45dB (A)
Technical data
PG 8130 / PG 8131 / PG 8132 / PG 8133 9
Ambient conditions
Permitted temperature range in operation 5 - 40°C
Max. relative humidity up to 31°C 80%
Relative humidity, declining proportionally to 40°C 50%
Transport conditions - permitted temperature range -20 - 60°C
Transport conditions - permitted relative humidity 10 - 85%
Transport conditions - permitted air pressure 500 - 1060hPa
Max. installation altitude above sea level 2000 m
Miele Australia Pty. Ltd.
ACN 005 635 398 ABN 96 005 635 398
1 Gilbert Park Drive Knoxfield, VIC 3180 Telephone: 1300 731 411 service.prof@miele.com.au
Melbourne:
www.miele-professional.com.au info@miele-professional.com.au
Miele New Zealand Limited
IRD 98 463 631 Level 2, 10 College Hill Freemans Bay Auckland 1011 New Zealand Telephone:
www.miele-professional.com.au info@miele-professional.com.au
Miele Global Headquarters Germany Miele & Cie. KG
Carl-Miele-Straße 29 33332 Gütersloh Federal Republic of Germany
0800 4 MIELE (0800 464 353)
Alteration rights reserved / Publication date: 2017-10-19 M.-Nr. 10 720 840 / 00
PG 8130
PG 8131
PG 8132
PG 8133
Loading...