Miele DGC6865XXLSS Specifications

PureLine Plumbed Combi-Steam Oven XXL
DGC 6865 XXL
Specification Sheets TRS 02212017
8mieleusa.com
PureLine Plumbed Combi-Steam Oven DGC 6865 XXL
SPECIFICATIONS
23686553USA
DGC 6865 XXL Features:
Plumbed water connection
Class leading capacity with 41% more
space than XL (with 4 shelf levels)
M Touch innovative and revolutionary controls are both easy-to-operate and navigate
MultiSteam technology delivers powerful external steam generation and optimum steam distribution via 6 inlet ports
Wired roast probe for perfect roasting
3-in-1 appliance
1. True European convection oven
2. Steam oven
3. Combination of steam and convection oven
MasterChef and MasterChef Gourmet menus offer over 100 food types to cook to perfection
Lift up control panel conceals water and condensate container (both containers are dishwasher safe)
Clean Glass door for easy clean-up
DGC 6865 XXL — Item
Overall Fascia Dimensions
Overall Unit Width - Excluding Fascia Dimension 21
Overall Unit Height - Excluding Fascia Dimension 23
Overall Unit Depth - Excluding Fascia Dimension 22
Built-In
Minimum Cabinet Width 22
Minimum Cabinet Depth 22
Minimum Opening Height 23
Additional Cut-Outs Required
Plumbing
Water Supply Requirements
Drainage Requirements
Water Intake Hose Connection
Drain Hose Connection
Electrical
Electrical Requirements 208/240V, 60Hz, 20A
Power Cord
Shipping
Shipping Weight 136 lbs (62 kg)
Shipping Dimensions 287/8” W x 283/8” H x 265/8” L
Support
Call Miele 800.843.7231
Miele Website
20/20 Link
237/16” (595 mm) W x 237/16” (595 mm) H x
7
/8” (23 mm) D
9
/16” (548 mm)
1
/4” (590 mm)
3
/8” (567 mm)
1
/16” (560 mm)
1
/2” (572 mm)
3
/8” (593 mm)
Venting and plumbing cut-out required
11
19
/16” x 19/16” (500 mm x 40 mm)
Connect to a cold water supply only. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pressure must be between 14.5 psi (1 bar) and may not exceed 87 psi (6 bar). If the pressure is higher than 87 psi (6 bar), a pressure reducing valve must be installed.
The drainage trap must not be located higher than the drain hose connection point on the appliance. This is to ensure that water can drain out completely after a program. The top of the drain hose must not be higher
11
than 19 connects to the drain trap. The drain hose must not be shortened. See installation manual for additional information.
Supplied hose: flexible braided hose 6’6” (2 m) with a 3/4” BPT fitting for connection to a shut off valve. The hose must not be shortened. Supplied hose: flexible pastic hose 9’10” (3 m) with a 3/4” end for connection to siphon. The plastic drain hose supplied must not be shortened.
Molded plug - NEMA 6-20 power cord 6’ 6
8www.mieleusa.com
82020technologies.com
/16” (500 mm) to where it
3
/4” (2 m)
DGC 6865 XXL
Specification Sheets TRS 02212017