PureLine Plumbed
Combi-Steam Oven XXL
DGC 6865 XXL
Specification Sheets TRS 02212017
8mieleusa.com
PureLine Plumbed Combi-Steam Oven
DGC 6865 XXL
SPECIFICATIONS
23686553USA
DGC 6865 XXL
Features:
• Plumbed water connection
• Class leading capacity with 41% more
space than XL (with 4 shelf levels)
• M Touch innovative and revolutionary
controls are both easy-to-operate and
navigate
• MultiSteam technology delivers powerful
external steam generation and optimum
steam distribution via 6 inlet ports
• Wired roast probe for perfect
roasting
• 3-in-1 appliance
1. True European convection oven
2. Steam oven
3. Combination of steam and
convection oven
• MasterChef and MasterChef Gourmet
menus offer over 100 food types to cook
to perfection
• Lift up control panel conceals water and
condensate container (both containers
are dishwasher safe)
• Clean Glass door for easy clean-up
DGC 6865 XXL — Item
Overall Fascia Dimensions
Overall Unit Width - Excluding Fascia Dimension 21
Overall Unit Height - Excluding Fascia Dimension 23
Overall Unit Depth - Excluding Fascia Dimension 22
Built-In
Minimum Cabinet Width 22
Minimum Cabinet Depth 22
Minimum Opening Height 23
Additional Cut-Outs Required
Plumbing
Water Supply Requirements
Drainage Requirements
Water Intake Hose Connection
Drain Hose Connection
Electrical
Electrical Requirements 208/240V, 60Hz, 20A
Power Cord
Shipping
Shipping Weight 136 lbs (62 kg)
Shipping Dimensions 287/8” W x 283/8” H x 265/8” L
Support
Call Miele 800.843.7231
Miele Website
20/20 Link
237/16” (595 mm) W x 237/16” (595 mm) H x
7
/8” (23 mm) D
9
/16” (548 mm)
1
/4” (590 mm)
3
/8” (567 mm)
1
/16” (560 mm)
1
/2” (572 mm)
3
/8” (593 mm)
Venting and plumbing cut-out required
11
19
/16” x 19/16” (500 mm x 40 mm)
Connect to a cold water supply only. Must
be connected to a shut-off valve. The water
shut-off valve must be accessible after
installation. The water pressure must be
between 14.5 psi (1 bar) and may not
exceed 87 psi (6 bar). If the pressure is
higher than 87 psi (6 bar), a pressure
reducing valve must be installed.
The drainage trap must not be located
higher than the drain hose connection point
on the appliance. This is to ensure that water
can drain out completely after a program.
The top of the drain hose must not be higher
11
than 19
connects to the drain trap. The drain hose
must not be shortened. See installation
manual for additional information.
Supplied hose: flexible braided hose 6’6”
(2 m) with a 3/4” BPT fitting for connection
to a shut off valve. The hose must not be
shortened.
Supplied hose: flexible pastic hose 9’10”
(3 m) with a 3/4” end for connection to
siphon. The plastic drain hose supplied must
not be shortened.
Molded plug - NEMA 6-20 power cord
6’ 6
8www.mieleusa.com
82020technologies.com
/16” (500 mm) to where it
3
/4” (2 m)
DGC 6865 XXL
Specification Sheets TRS 02212017