MidNite Solar MNBE-8D2x2, MNBE-8D2x2 Deluxe Instructions Manual

MNBE-8D2x2 INSTRUCTIONS
MidNite Solar 17722 – 67Th Ave Ne Arlington, Wa 98223 USA Ph 360-403-7207 Fax 360-691-6862 www.midnitesolar.com
MNBE-8D2x2 OUTDOOR 3R ENCLOSURE
MNBE-8D2x2
Battery Enclosure with locking door and one shelf. Outdoor 3R rain type design. Powder coated aluminum and stainless steel construction. Holds four 8D batteries. Has spaces for a single 175 or 250 amp battery breaker and up to 4 MNDC panel mount breakers (1 to 100 amps available). Breakers not included Ships un-assembled.
MNBE-8D2x2 Deluxe
Battery Enclosure with locking door and one shelf. Outdoor 3R rain type design. Powder coated aluminum and stainless steel construction. Holds four 8D batteries. Comes with 250 amp battery breaker, 2 of our 4/0 12 inch cables and a single 36 inch 4/0 cable for interconnecting the batteries. It also has spaces for up to 4 MNDC panel mount breakers (1 to 100 amps available). Ships un-assembled.
MNBE-8D2x2 Instructions (continued)
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS - These instructions contain important safety and operating
instructions for the MidNite Solar MNBE-8D2x2 and MNBE-8D2x2-Deluxe Battery Enclosures for residential and commercial applications.
If you do not fully understand any of the concepts, terminology, or hazards outlined in these instructions, please refer installation to a qualified dealer, electrician or installer. These instructions are not meant to be a complete explanation of a renewable energy system.
GENERAL PRECAUTIONS
WORKING WITH OR IN THE VICINITY OF A LEAD ACID BATTERY, SEALED OR VENTED IS DANGEROUS. VENTED BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION. FOR THIS REASON, IT IS VERY IMPORTANT THAT BEFORE SERVICING EQUIPMENT IN THE VICINITY OF LEAD-ACID BATTERIES, YOU REVIEW AND FOLLOW THESE INSTRUCTIONS CAREFULLY.
If service or repair should become necessary, contact MidNite solar Inc. Improper servicing may result in a risk of shock, fire or explosion. To reduce these risks, disconnect all wiring before attempting any maintenance or cleaning. Turning off the inverter will not reduce these risks. Solar modules produce power when exposed to light. When it is not possible to disconnect the power coming from the Photovoltaics by an external means such as a combiner, cover the modules with an opaque material before servicing any connected equipment.
Never attempt to charge a frozen battery. When it is necessary to remove a battery, make sure that the battery bank disconnect breaker is in the off position and that the PV breakers, grid breakers and any other sources of power to the inverter are in the off position. Then remove the negative terminal from the battery first.
To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer as well as the manufacturer of any additional equipment used in the vicinity of the batteries. Before installing the battery enclosure, read all instructions and cautionary markings in or on any connected electrical equipment.
Avoid producing sparks in the vicinity of the batteries when using vented batteries. Provide ventilation to clear the area of explosive gases. Sealed AGM and Gel batteries do not under normal conditions create explosive gases. Be especially cautious when using metal tools. Dropping a metal tool onto batteries can short circuit them. The resulting spark can lead to personal injury or damage to the equipment. Provide ventilation to outdoors from the battery compartment when installing vented batteries such as golf cart T-105 batteries. The addition of a spill tray is also a good idea.
Clean all battery terminals. Very high currents are drawn from the batteries; even a small amount of electrical resistance can result in overheating, poor performance, premature failure or even fire. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes. Wear complete eye and clothing protection. Always avoid touching eyes while working near batteries. If battery acid or battery terminal corrosion contacts skin or clothing, wash immediately with soap and water. If acid enters the eyes, immediately flood with cool running water for at least 15 minutes and get medical attention immediately. Baking soda neutralizes battery acid electrolyte. Keep a supply near the batteries.
Do not work alone. Someone should be in the range of your voice or close enough to come to your aid when you work with or near electrical equipment.
Remove rings, bracelets, necklaces, watches etc. when working with batteries, photovoltaic modules or other electrical equipment. Power from an illuminated photovoltaic array makes a very effective arc welder with dire consequences if one of the welded pieces is on your person.
To reduce the risk of injury, connect only deep cycle lead acid type rechargeable batteries. Other types of batteries may leak or burst, causing personal injury or damage.
P a g e 1 0 - 2 4 5 - 1 R E V : A
2 |
MNBE-8D2x2 Instructions (continued)
INSTRUCTIONS DE SECURITÉ IMPORTANTES
CONSERVER CES INSTRUCTIONS
Ces instructions contiennent des informations importantes pour utiliser le Midnite Solar SMA MNX-240 Autotransformer en toute sécurité.
1. Avant l’utilisez cet appareil lis et comprends toutes les instructions et avertissements.
2. Si vous ne comprenez pas l’une des concepts ou des instructions contenu dans cette manuel
consulter un agent spécialisé.
3. Si des réparations sont nécessaires contactez MidNite Solar pour plus des informations. Danger de
choc électrique et de risque de brulure. Rien à dépanner à l'intérieure du cette appareil. Ne pas ouvrir le couver. Pour toute réparation ou service d'entretien, consulter un agent spécialisé. Il y’a peut-être plusieurs sources d’alimentation dans cette system. Débrancher toutes les interrupteurs avant toute d'entretien où nettoyage.
4.
Ne travaillez pas seul. Quelqu'un devrait toujours être à proximité pour aider en cas d'une situation d'urgence.
5. Retirer bagues, bracelets, colliers, montres, et quelles choses comme ça. Il y’a risque des blessures
graves s’il y’a un court-circuit. Cela pourrait ruiner votre journée entière.
6. Le câblage doit être fait en conformité avec le National Electrical Code ANSI / NFPA 70. Utiliser
des méthodes de câblage de catégorie 1 pour les connexions de câblage sur .des terminaux d'un circuit de classe 2. Utilisez uniquement des fils de AWM de calibre 14-1/0. Sélectionnez le type de câble utilisé sur la base de la protection prévue par les disjoncteurs / fusibles.
P a g e 1 0 - 2 4 5 - 1 R E V : A
3 |
MNBE-8D2x2 Instructions (continued)
Step 1:
Install each side to the shelf. The bottom has the flange bent outward. Use1/4-20 x 0.50 flathead screws supplied.
Panhead Screw
Flathead Screw
Nut
Hardware identifier Lockwasher
Table of Contents
Warnings ................................................................................................................................................................ 2
Unpacking ............................................................................................................................................................... 4
Assembly ................................................................................................................................................................ 4
Wiring – Battery Configuration ............................................................................................................................. 7
Circuit Breaker Selection ....................................................................................................................................... 7
Assembly drawing .................................................................................................................................................. 8
Battery Arrangement ............................................................................................................................................. 9
Warranty .............................................................................................................................................................. 12
Unpacking
The MNBE-8D2x2 and MNBE-8D2x2-Deluxe each ship in two boxes. Unpacking is the same for each model except that the Deluxe model has extra components shipped within the shelf.
Before unpacking and assembly make sure there is enough space to work in comfortably. It is recommended to unpack the painted pieces onto carpet or other soft surface to avoid scratching.
Assembling the MNBE-8D2x2 and MNBE-8D2x2-Deluxe
Assembly of the MNBE-8D2x2 and MNBE8D2x2-Deluxe is essentially identical. The differences between the two models is that the deluxe model comes with extra components.
The MNBE-8D2x2 and Deluxe are 3R outdoor rated. In order to maximize rain-tightness, silicone sealant (Not included) is applied to several locations on the box during assembly.
General instructions below. Refer to the assembly drawing on page 7.
P a g e 1 0 - 2 4 5 - 1 R E V : A
4 |