HEINE BETA® 4 NT Rechargeable Handle
MED 113593 2018-01-23 V-200.00.603
Page 2
HEINE BETA® 4 NT Rechargeable Handle
Please r ead and fo llow thes e instr uction s for use an d keep the m for futu re refer ence.
Intended Use
The BETA 4 NT rechargeable instru ments ma nufac tured by th e HEINE co mpany.
Feder al law r estr icts t his device to s ale by o r on the o rder o f a Physi cian o r Prac titi oner !
Warnings and Safety Information
CAUTION! Indicates potential hazardous situations. Ignoring the corresponding instructions may lead
to dangerous situations of mild to moderate extent. (Background color, yellow; Foreground color, black for color print, or black in light-gray background.)
NOTE! Indic ates valu able ad vice in ter ms of set u p, operat ion, mai ntenan ce or repa ir, as applic able. Notes are important, but not related to hazardous situations.
Product overview
1 AV-Connector 2 Unlock button 3 Rheostat 4 Outer sl eeve 5 Bottom i nser t
Sett ing up Inserting rechargeable battery
To set up the HEIN E recha rgeabl e handle , unscre w the botto m inser t (5) from the handl e module a nd inse rt the rechargeable battery into the outer sleeve (4) as described in the rechargeable battery instructions. Screw the bott om inser t back in.
Remove insulation before use
handle is designed exclusively for the operational use of medical examination
1
2 3
4
5
Chan ging of t he Li- ion L ba tter y
Remove the b ottom i nser ts as desc ribed a bove. Rem ove the bat tery f rom the bot tom ins ert by pu lling it away from th e bottom i nser t and repl ace it wi th a new bat tery. Bat tery an d botto m inser t are con necte d corre ctly onc e a distin ct click s ound ha s been he ard. Scr ew the bot tom inse rt with t he batte ry bac k into the handle.
2/8 MED 113593 2018-01-23
Page 3
Only charge the rechargeable handle with the NT4 charger.
Setup an d opera tion of the H EINE NT4 charg er is des cribe d in separ ate inst ructio n docum ents.
Char ging of t he Li-ion L bat tery
The BETA 4 NT ha ndle is de signe d speci cally f or the use o f the Li-i on L recha rgeab le batte ry. To check the batter y charge, the bot tom inse rts ar e equipp ed with a ch arge leve l indic ator.
The cha rge level in dicato r shows a co nstant o range w hen the ba tter y needs to b e recha rged. With a full y disch arged ba tter y, the charg e level indi cator go es out an d the inst rument h ead is dis abled .
Attaching the instrument heads
Automatic Connector (AV)
Attach t he instr ument h ead onto th e handle f rom above i n such a way th at the con nector  ts into the g uides on the han dle head . Push the in strum ent into th e handle h ead until i t locks in p lace wit h an audib le ”click“. To remove the ins trume nt head tur n the con nector (1) on th e handle h ead to the r ight with t he thumb a nd foreng er and, u sing the ot her han d, pull the i nstrum ent hea d up and out .
Removing the instrument
To remove the hea d rotate it a nti-c lockw ise and p ull it off.
Operation
To activate the i nstrum ents pre ss the un lock but ton (2) and t urn the rh eosta t (3) cloc kwise. T he light i ntensi ty is indic ated by the b ar .
Positio n ”1“ shows the ma ximum brightne ss; you ca n set any in termed iate level a s desir ed. To turn the device off, turn the rheostat back to position ”0“.
Hygienic Reprocessing
Instructions on hygienic reprocessing must be adhered to, based on national standards, laws and guidelines. Classication according to KRINKO: non-critical Spaulding Classication USA: non-critical
Allow the d evice to co ol down be fore rep roces sing.
Before reprocessing, disconnect the device from the power source.
In the event o f suspe cted con tamina tion, ca rry ou t hygieni c repro cessin g of the ins trume nt.
The des cribe d reproc essin g measu res do not re place t he speci c rule s applic able for t he esta blishm ent.
Only the rep rocessing agents and pro cedur es calle d out in thi s instru ction fo r use are a pproved . The repr oces sing is to be c arrie d out by pe rsons wi th adeq uate hygie nic expe rtise
Obser ve the ins truct ions of the m anufac turer of t he repro cess ing medi a.
Ensure th at the ins trume nt is comp letely d ry aft er repro cessi ng befor e you use it a gain.
Procedure
Clean an d disinf ect the ha ndles m anuall y (wipe cle an and wi pe disin fect). Recommended agents Cleaning agent, if necessary: enzymatic (e.g. Cidezyme Disinfectant agent: alcoh olic and /or quater nary a mmoni a compou nds (e.g. SU PER Sani- Cloth
®
Sani-Cloth
Maintenance
The main tenanc e is limite d to chang ing the ba tter y. The proce dure is de scrib ed in the s ection ”Changing the Li-ion L battery“.
Service
The devi ce has som e compo nents se rvic eable by t he end use r.
AF3, by PDI®, Sani-Cloth® HB by PDI®)
®
by ASP®)
®
by PDI®,
MED 113593 2018-01-23
3/8
Page 4
General Warnings
Check th e corre ct oper ation of th e device b efore us e! Do not us e the devi ce if ther e are visi ble sign s of damage.
Do not use t he devic e in re- or e xplosi ve risk ar ea (e.g. oxyge n satur ated or an aesthe tic envi ronmen ts) This pro duct is n ot allowe d to be enter ed or use d in stron g magnet ic elds l ike MRI sca nners . Do not mod ify the d evice. Use only o rigina l HEINE pa rts, s pare par ts, accessor ies and p ower sour ces. Repair s shall o nly be car ried ou t by quali ed per sons. Turn the handle off during the charging process. The handle is not designed for continuous use. The operating time of the handle depends on the
maximum operating time of the examination head.
General Notes
The warr anty fo r the enti re produ ct is inval idated i f non-g enuine H EINE pro ducts or n on-or iginal p arts are use d and if rep airs or m odica tions ar e made to the d evice by p erson s not auth orized by H EINE. For more information, please visit www.midmark.com.
The expe cted lif e cycle, whe n the devi ce is nor mal use d and the war ning an d safety i nforma tion as we ll as the mai ntenan ce instr uctio ns are obs erved , is up to 10 year s. Beyond th is perio d, the pro duct may c ontinu e to be used i f it has be en deter mined to b e in safe an d good condition.
If you don’t u se the devi ce for a lon ger per iod of tim e, pleas e remove th e batter ies in ad vance. Ensure th at mois ture doe s not pene trate the a rea aro und the re charge able ba tter y and the bo ttom
insert. Check the rechargeable batteries regularly. In case of any abnormalities in the operating or recharging
times, replace the rechargeable batteries. If the rechargeable battery has not been recharged for a long period it may discharge automatically.
Precautions for HEINE rechargeable batteries
Do not put i nto re, do n ot shor t-circu it, do not m odify, do no t steril ize, do not dr op, do not exp ose to severe sh ocks or to di rect su nlight.
Dispo se of batte ries in t he event of v isible o r presum ed dama ge (e.g. lea king liq uid, mec hanica l damag e). The bat teries c an be dam aged by li quid. Th ey must not b e rinse d in runni ng water or s ubmer ged unde r
wat er.
Disposal
The prod uct mus t be recyc led as se parate d elect rical a nd elect ronic de vices. P lease ob serv e the relevant state-specic disposal regulations.
Dispo se at your lo cal col lectio n point.
4/8 MED 113593 2018-01-23
Page 5
Technical specications
Environmental conditions for operation
Environmental conditions for storage
Environmental conditions for transport
Recommended charging temperature for the rechargeable batteries
Technical specications of the HEINE rechargeable batteries
Cell type Lithium-ion
Rated voltage 3.7 V
Capacity 2300 mA h
Charging time
Dimensions Ø 26 x 83 mm
Weight
+10 °C to +35 °C 30 % to 75 % rel. hum idity 700 hPa to 1060 h Pa
+5 °C to +45 °C 45 % to 80 % rel. h umidit y 500 hPa to 106 0 hPa
-20 °C to +50 °C 45 % to 80 % rel. h umidit y 500 hPa to 106 0 hPa
+10 °C to +35 °C
technology
approx. 2 h
62 g
MED 113593 2018-01-23
5/8
Page 6
Explanation of utilized symbols The following symbols are used on the device or on the packaging:
Catalogue- or order number
REF
Manufacturer
Date of man ufactu re
Produc t beari ng this sym bol may no t be dispo sed of tog ether wi th general household was te, but in stead re quires s eparat e dispos al according to local provisions. (European Waste Electrical and Electronic Equipment Directive, WEEE)
Dispo se at your lo cal col lectio n point
Temperatu re limit s in °C for stor age and t ransp ort
Temperatu re limit s in °F for sto rage and t ransp ort
Humidi ty limit ation fo r storag e and tran spor t
Pressu re limit ation for s torage a nd tran spor t
Fragile, handle with care!
Keep dry !
6/8 MED 113593 2018-01-23
Page 7
Follow instructions for use! (Backgr ound col or, blue; Fore ground c olor, white f or color p rint, or white on black background.)
Direct current DC
MED 113593 2018-01-23
7/8
Page 8
Manufacturer
HEINE O ptotec hnik GmbH & Co. KG
Kient alstr. 7 · 82211 Herr sching · GERMA
www.heine.com
Distributed by
Midmark Corporation
60 Vist a Drive
NY
Versailles, Ohio 45380 www.midmark.com