Midmark DM-FTC001, DM-FTC003, DM-FTC004, DM-FTC002 Installation Instructions Manual

Page 1 of 16
RECOMMENDED TOOLS
• Screwdriver, straight blade and phillips.
• Level
• Tape Measure
• 1/4" socket and ratchet
• Open end / box end wrenches
• 3/8" masonary bit
• Hammer drill
RECOMMENDED FASTENERS (Supplied)
Wood Floor
042-0209-00 Screw, Lag (3/8" x 2 1/2") Qty 4 045-0001-00 Washer, Flat (3/8") Qty 4
Concrete Floor
042-0208-00 Anchor, Wedge (3/8" x 3 1/2") Qty 4 045-0001-00 Washer, Flat (3/8") Qty 4
Brackets / Shims
050-5812-X0 Anchor, Mounting Clip Qty 4 053-1242-00 Shims Qty 4
ADDITIONAL HARDWARE (Supplied)
040-0010-12 Mounting Screws (10-24 x 5/8") Qty 4 045-0001-08 Lockwashers, Internal (#10) Qty 4 040-0010-48 Particle Bd. Screws (#10 x 5/8") Qty 4 053-0668-00 Shelf Clips Qty 4 / shelf
TASK LIGHT CONFIGURATIONS
Task Light w/ RH Clock & LH Viewer Task Light w/ Clock-RH Mounted Task Light w/ Clock-LH Mounted Task Light (Full) Task Light w/ LH Clock & RH Viewer Task Light w/ RH Filler Panel Task Light w/ LH Filler Panel
DA135400i
Shown with: Task Light, Right-hand Clock and Left-hand Viewer.
MODEL: DM-FTC001,
002, 003, 004
Installation
Instructions
Page 2 of 16
Electrical
Supply
120 VAC / 15 Amp / 60 Cycle
3-wire, Dedicated Circuit
Cabinet
Electrical
Terminal
Box
Outlets
Vacuum
Supply
Air
Supply
Water
Supply
Back
Finished Floor
Front
Top View of Base
Right Side Plumbin g
Rough-In Perimeter
NOTE Midmark Casework unit must be connected to a dedicated circuit breaker rated 15 amps, 120 VAC. Failure to comply could result in a n ov e r load of the electrical circuit and / or components. All electrical and plumbing connections must be made by a licensed electrician and plumbing contractor fol­lowing applicable local, city, and national codes.
Midmark Casework unit contains 4 electrical duplex outlets, which are rated at a combined 15 amps
. This rating must be taken into account when plugging device(s) into the available outlets.
Figure 1
Floor Layout (as applicable)
A - The floor layout (Figure 1).
NOTE
A full size pre-installation Floor Template (003-1270-00 ) and Wall Template (003-1352-00) are available upon request or refer to rough-in dimensions on next page (Figure 2 & 3).
B - Have licensed electrical and
plumbing contractors position and install electrical outle t receptacles and related plumb­ing using the pre-installation template or layout (Figure 1).
NOTE
Assure floor is of such construc­tion that the unit(s) will be ade­quately supported and anchored. If necessary, contact a licensed contractor to reinforce the floor-
Page 3 of 16
Figure 3
Figure 2
DA155800i
A
B
B
C
D
E
A
Air
Water
Vacuum
F
G
H
I
42 1/2 in
(107.9 cm)
[Metal to Metal]
or
44 1/4 in
(112.4 cm)
[Panel to Panel]
21 in
(53.4 cm)
J
"A"
10 3/8"
(26.4 cm)
"F"
3"
(7.6 cm)
"B" [M to M]
3"
(7.6 cm)
"G"
15 1/2"
(39.4 cm)
"C"
1 1/8"
(2.9 cm)
"H"
2 1/2"
(6.4 cm)
"D"
6 3/16"
(15.7 cm)
"I"
12"
(30.5 cm)
"E"
7 3/8"
(18.7 cm)
"J"
6"
(15.2 cm)
"B" [P to P]
4"
(10.1 cm)
DA155900i
Air
Water
Vacuum
A
B
C
D
E
F
J
K
42 1/2 in
(107.9 cm)
[Metal to Metal]
or
44 1/4 in
(112.4 cm)
[Panel to Panel]
31.06 in
(78.9 cm)
A
G
H
I
3"
(7.6 cm)
"K"
3/4"
(1.9 cm)
"B"
9 1/2"
(24.1 cm)
"G"
11 1/8"
(28.3 cm)
"C"
3 3/4"
(9.5 cm)
"H"
11 5/8"
(29.5 cm)
"D"
3 1/4"
(8.3 cm)
"I"
26"
(30.5 cm)
"E"
8"
(20.3 cm)
"J"
4 1/8"
(10.5 cm)
"F"
12"
(30.5 cm)
4"
(10.1 cm)
"A" [M to M] "A" [P to P]
Page 4 of 16
Unpacking
NOTE
Inspect all components for ship­ping damage. A concealed damage report must be f iled with the carrier by the pers on receiving the goods within 15 days of delivery.
A - Remove the shrink wrap, strap-
ping and cardboard filler
B - If supplied, remove the solid
panels and shelves.
C - Remove the base and midsec-
tion assembly from the skid and place in position on floor.
D - Remove the Overhead Section
from the carton.
DA176200i
Figure 4
Solid Panel
Overhead
Page 5 of 16
Figure 5
Setting Up
NOTE
If applicable, refer to 2” Drawer Removal on next page as removal is different.
A- If necessary , remove the drawers by
pulling the drawer outward until it meets resistance.
B- On both sides of drawer, pull outward
until locking slots (1) on drawer are free of tabs (2) on drawer glides (3).
C- Lift drawer upward (4) while pulling
outward to free rear of drawer from hooks (5) on glide.
D - On base sections that have doors,
open door and remove bottom shelf.
NOTE
When reinstalling drawers assure back of drawer is positioned beneath hooks (4) on glides and tabs (2) on glide snap into locking slots (1) on drawer.
Loading...
+ 11 hidden pages