IMPORTANT SAFETY INSTRUCTIONS
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Always do this.
Never do this.
CAUTION
This symbol indicates the possibility of injury or damage to property.
WARNING
WARNING
Plug in power plug properly.
Do not modify power cord length or share the outlet with other appliances.
Always ensure effective grounding.
Unplug the unit if strange sounds, smell, or smoke comes from it.
Keep firearms away.
Ventilate room before operating air conditioner if there is a gas leakage from another appliance.
Otherwise, it may cause electric shock or fire due to excess heat generation.
It may cause electric shock or fire due to heat generation.
Incorrect grounding may cause electric shock.
It may cause fire and electric shock.
It may cause fire.
It may cause explosion, fire and, burns.
It may cause electric shock or fire due to heat generation.
It may cause electric shock.
It may cause failure of machine or electric shock.
It may cause fire and electric shock.
It may cause fire and electric shock.
It may cause electric shock or fire. If the power cord is damaged, it must be replaced by the manufacturer or an authorised service centre or a similarly qualified per son in order to avoid a hazard.
This could damage your health.
Incorrect installation may cause fire and electric shock.
It may cause electric shock.
It may cause an explosion or fire.
It may cause failure and electric shock.
Do not operate or stop the unit by inserting or pulling out the power plug.
Do not operate with wet hands or in damp environment.
Do not allow water to run into electric parts.
Do not use the socket if it is loose or damaged.
Do not use the power cord close to heating appliances.
Do not damage or use an unspecified power cord.
Do not direct airflow at room occupants only.Always install circuit breaker and a dedicated power circuit.
Do not open the unit during operation.
Do not use the power cord near flammable gas
or combustibles, such as gasoline, benzene,
thinner, etc.
Do not disassemble or modify unit.
!!
!!
!!
!!
!!
!!
!!
!!
READ THIS MANUAL
1
When the air filter is to be removed, do not touch the metal parts of the unit.
It may cause an injury.
Do not clean unit when power is on as it may c ause fi re an d el ectric sh ock, it may cause an injury.
Operation with windows opened may cause wetting of indoor and soaking of household furniture.
When the unit is to be cleaned, switch off, and turn off the circuit breaker.
Use caution when unpacking and installing. Sharp edges could cause injury.
Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
This could injure the pet or plant.
It may cause electric shock and damage.
Do not put a pet or house plant where it will be exposed to direct air flow.
Ventilate the room well when used together with a stove, etc.
An oxygen shortage may occur.
Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects.It may cause deterioration of quality, etc.
It may cause failure of product or fire.
Do not use for special purposes.
If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.
!!
!!
!!
!!
It may cause failure of appliance or accident.
Appearance may be deteriorated due to change of product color or scratching of its surface.
If bracket is damaged, there is concern of damage due to falling of unit.
There is danger of fire or electric shock.
Operation without filters may cause failure.
It contains contaminants and could make you sick.
Stop operation and close the window in storm or hurricane.
!!
Do not use strong detergent such as wax or thinner but use a soft cloth.
Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
Hold the plug by the head of the power plug when taking it out.
!!
Turn off the main power switch when not using the unit for a long time.
!!
!!
!!
Always insert the filters securely. Clean filter once every t wo w eeks.
!!
Do not place heavy object on the power cord and ensure that the cord is not compressed.
Do not drink water drained from air conditioner.
CAUTION
2
CAUTION
Do not place obstacles around air-inlets or inside of air-outlet.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room. The appliance with electric heater shall have at
l east 1 m eter s pace to th eco mbustible materials.
Contact the authorised service technician for
repair or maintenance of this unit.
Contact the authorised installer for installation
of this unit.
Do not operate the louvers with your hands, it
may cause an injury.
IMPORTANT SAFETY INSTRUCTIONS
The appliance shall be installed in accordance
with national wiring regulations.
This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge,unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not, under any circumstances, cut, remove, or bypass the grounding prong.
Power supply cord with 3-prong grounding plug and current detection device
Grounding type wall receptacle
WARNING
NOTE:
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
WARNING
For Your Safety
WARNING
Prevent Accidents
WARNING
Electrical Information
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Operation of Current Device
(Applicable to the unit adopts current detection device only )
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by a light on the plug head.)
3
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following: Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the the cabinet and behind the grille. If the air conditioneri s t o b e in stalled in a w indow, yo u w ill pr obably w ant to cl ean both sides of the g lass f irst.I f th e w indowis a tri ple-track ty pe w ith a sc reen pa nel included, remove the screen completely before installation. Be sure the air c onditionerh as b een s ecurely a nd c orrectly in stalled a ccording to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit. When handling the air conditioner, be careful to avoid cuts f rom s harp m etal f ins on front and rear coils.
The complete electical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation. Do not run air conditioner without side protective cover in place.This could result in mechanical damage within the air conditioner. Do not use an extension cord or an adapter plug.
IMPORTANT SAFETY INSTRUCTIONS
Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for
correct operation.
The power supply must be replaced if it fails reset when
either the TEST button is pushed, or it cannot be reset. A
new one can be obtained from the product manufacturer.
If power supply cord is damaged, it cannot be repaired. It
MUST be replaced by one obtained from the product
manufacturer.
NOTE:
NOTE:This air conditioner is designed to be operated
under condition as follows:
Cooling operation
Outdoor temp:
Indoor temp:
OO OO
64-109 F/18-43 C (64-125 F/18-52 C for special tropical models)
O
O
62-90 F/17-32 C
Note: Performance may be reduced outside of these operating temperatures.
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Device for details.In the event that the power supply cord is damaged, it cannot be repaired-it must be replaced with a cord from the product manufacturer.
4
INSTALLATION INSTRUCTIONS
Read these instructions completely and carefully.
IMPORTANT- Save these
instructions for local inspector s use.
IMPORTANT- Observe all
governing codes and ordianaces.
Note to Consumer- Keep these
instructions for futrue reference.
Note to Installer- Be sure to leave these
instructions with the Consumer.
Completion time- Approximately 1 hour.
We recommend that two people install this product. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Warranty. You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
BEFORE YOU BEGIN
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
CAUTION
Do not change the plug on the power cord of the air conditioner.
Aluminum house wiring may present special problems- consult a qualified electircian.
When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils.
TOOLS YOU WILL NEED
Screwdriver
Level
TOOLS YOU MAY USE
Screwdriver
Pencil
Ruler or tape measure
Scissors or knife
Save Carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter, or when not in use.
NOTE:
H
Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches(584mm to 914mm) .
WINDOW REQUIREMENTS
Model
H
5000~8000Btu/h
10000~12000Btu/h
14 (356mm) 15-1/2 (394mm)
Table 1
Skill level- Installatio o f this appliance
requires basic mechanical skills.
5
Fig.C
NOTE: The top rail hardware and the Fig.A, Fig.B and Fig.C are not applicable to the units more than 10000Btu/h.Before installing unit, the top rail must be assembled on the unit (For <10000Btu/h models only).
INSTALLATION INSTRUCTIONS
Lower sash must open sufficiently to allow a clear vertical opening (H) of following size (see Table 1). Side louvers and the rear of the AC must have clear air space to allow enough airflow through the condenser,for heat removal. The rear of the unit must be outdoors, not inside a building or garage.
PREPARE THE WINDOW
11
C: Align the hole in the top rail with those in the top of the unit as shown in Fig.B
D: Secure the top rail to the unit with the 3/8 Screws as shown in Fig.C.
NOTE: For safety reasons, all four(4) screws MUST be securely fastened.
INSTALL THE ACCORDION PANELS
33
NOTE: Top rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of (5/16 ). This is
necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained.
A.Place unit on floor, a bench or a table. Hold the Accordion Panel in one hand and gently pull back the center to free the open end. See Fig.1
Fig.1
Fig.B
PREPARE AIR CONDITIONER
22
A: Remove the air conditioner from the carton and place on a flat surface.
B: Remove top rail and R1 hardware (R1 hardware
only for Energy star models) from the packaging material as shown in Fig. A.
Top Rail Hardware
3/8 Screws (4)
Top Rail (1)
Packaging
Fig.A
Top Rail
R1 hardware (2)
R1 hardware(for > )10000Btu/h models
only
R1 hardware (for < )10000
Btu/h models only
3/4 (or 1/ ) Screws (7)
2
Lock Frame (2)
Sash Lock (1)
Mounting Hardware
Window sash seal foam (1)
Weather stripping
(5)
(10 *3/4 *1/12 )
NOET: Weather stripping is only for Energy star models.
Loading...
+ 11 hidden pages