Midea WPPF10CW71N User Manual

Portable Air Conditioner
(Local Air Conditioner)
Instruction Manual
Model: WPPF10CW71N
Thank you for purchasing our Portable Air Conditioner. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
READ AND SAVE THESE INSTRUCTIONS!
Contents
Safety Precautions.................................................................................................................................3
Cautions..................................................................................................................................................4
Installation...... ........................................................................................................................................5
Operation................................................................................................................................................9
Maintenance...... ...................................................................................................................................14
Faults Diagnosis...... ............................................................................................................................15
Design and Compliance Notes ...........................................................................................................16
Sociable Remark...... ...........................................................................................................................17
Warranty And Return Policy.................................................................................................................. 18
Preparation
control panel
horizontal louver blade
front
upper air filter (behind the grille)
handle (both sides)
upper air intake
drain outlet
air outlet
lower air filter
lower air intake
power plug socket
Caster
drain outlet
(only for pump heating mode)
power cord outlet
power cord buckle
bottom tray drain outlet
rear
Safety Precautions
Please read through these instructions before you start the installation process. Improper installation can cause damage to the unit, your personal property, and also poses a personal safety hazard.
-Installation must be performed according to the installation instructions. Improper installation
can cause water leakage, electrical shock, or fire.
-Use only the included accessories and parts, and specified tools for the installation. Using non
-standard parts can cause water leakage, electrical shock, fire, and injury or property damage.
-Make sure that the outlet you are using is grounded and has the appropriate voltage. The
power cord is equipped with a three-prong grounding plug to protect against shock. Voltage
information can be found on the side of the unit, behind the grille.
-Install the unit in on a flat, sturdy surface. Failure to do so could result in damage or excessive
noise and vibration.
-The unit must be kept free from obstruction to ensure proper function and to mitigate safety
hazards.
-DO NOT modify the length of the power cord or use an extension cord to power the unit. DO
NOT share a single outlet with other electrical appliances. Improper power supply can cause
fire or electrical shock.
-DO NOT install your air conditioner in a wet room such as a bathroom or laundry room. Too
much exposure to water can cause electrical components to short circuit.
-DO NOT install the unit in a location that may be exposed to combustible gas, as this could
cause fire.
-The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or
to roll over objects, as these could cause tipping.
-DO NOT operate a unit that has been dropped or damaged.
-Only use the included accessories and specified parts for installation. Using nonstandard
parts can cause water leakage, electrical shock, fire, and injury or property damage.
-The unit must be kept free from obstruction to ensure proper function.
-DO NOT allow children to play with the air conditioner. Children must be supervised around
the unit at all times.
-If the air conditioner is knocked over during use, turn off the unit and unplug it from the main
power supply immediately. Visually inspect the unit to ensure there is no damage. If you
suspect the unit has been damaged, contact a technician or customer service for assistance.
-In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
Cautions
-This appliance can be used by children aged from 8 years and above and person with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play the appliance. Cleaning and user maintenance
shall not be made by children without supervision. (be applicable for the European Countries)
-This appliance is not intended for use by persons (including childern) with reduced physical,
sensory or mental capabilities or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their
safety. (be applicable for other countries except the European Countries )
-Children should be supervised to ensure that they do not play with the appliance.
-If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or
similarly qualified persons in order to avoid a hazard.
-Prior to cleaning or other maintenance, the appliance must be disconnected from the supply
mains.-Do not install the appliance in a location that may be exposed to combustible gas.
-If combustible gas accumulates around the unit, it may cause fire.-Do not run cord under
carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord
under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped
over.
-Do not operate unit with a damaged cord or plug. Discard unit or return to an authorized service
facility for examination and/or repair.
-To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control
device.
-The appliance shall be installed in accordance with national wiring regulations.
-Contact the authorised service technician for repair or maintenance of this unit.
-Contact the authorised installer for installation of this unit.
-When there are wide differences between "USER' S MANUAL" and "Remote controller
Illustration" on function description, the description on "USER' S MANUAL " shall prevail.
-Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
Choosing The Right Location
Installation
Your installation location should meet the following requirements:
-Make sure that you install your unit on an even
surface to minimize noise and vibration.
-The unit must be installed near a grounded plug,
and the Collection Tray Drain (found on the back
of the unit) must be accessible.
-The unit should be located at least 30cm (12”) from
the nearest wall to ensure proper air conditioning.
-DO NOT cover the Intakes, Outlets or Remote Signal
Receptor of the unit, as this could cause damage to
the unit.
Note About Fluorinated Gasses
-This air-conditioning unit is a hermetically sealed unit that contains fluorinated gasses. For specific information on the type of gas and the amount, please refer to the relevant label on
the unit itself.
-Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
-Product uninstallation and recycling must be performed by a certified technician.
-If the system has a leak-detection system installed, it must be checked for leaks at least every 12 months.
-When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
NOTE:
All the illustrations in the manual are for explanation purpose only. Your machine may be
slightly different. The actual shape shall prevail.The unit can be controlled by the unit control panel alone or with the remote controller. This manual does not include Remote Controller Operations, see the <<Remote ControllerInstruction>> packed with the unit for details.
Installation
Tools Needed
-Medium Philips screwdriver; -Tape measure or ruler; -Knife or scissors;
-Saw (optional, to shorten window adaptor for narrow windows)
Accessories
Your Window Installation Kit fits windows 67.5-123cm(26.5-48”) and can be shortened for
smaller windows.
Part
Description
Unit Adaptor
Exhaust Hose
Window Slider Adaptor
Bolt
Window Slider A
Window Slider B
Foam Seal A (Adhesive)
Foam Seal B (Adhesive)
Foam Seal C (Non-adhesive)
Security Bracket and 2 Screws
Drain Hose
Drain Hose Adaptor(only for
Quantity
1 pc
1 pc
1 pc
1 pc
1 pc
1 pc
2 pc
2 pc
1 pc
1 set
1 pc
1 pc
heat pump mode)
LED
TIMER
ON
TIMER
OFF
SHORT
CUT
TEMP
SWING
FAN
MODE
SLEEP
ON/OFF
Remote Controller and Battery
(For remote control models only)
1 set
Window Installation Kit Step One: Preparing the Exhaust Hose assembly
Press the exhaust hose into the window
slider adaptor and unit adaptor, clamp automatically by elastic buckles of the adaptors.
Exhaust hose
Unit adaptor Window slider
adaptor
Exhaust hose assembly
Step Two: Install the Exhaust hose assembly to the unit
Insert unit adaptor of the Exhaust hose assembly
into the lower groove of the air outlet of the unit while the hook of the adaptor is aligned with the hole seat of the air outlet and slide down the
Exhaust hose assembly along the arrow direction
for installation.
Hook
adaptor
Hole Seat
Lower groove
Make sure the adaptor is inserted into the lower groove of the air outlet.
Step Three: Preparing the
Installation
Adjustable Window Slider
Bolt
1. Depending on the size of your window,
adjust the size of the window slider.
2. If the length of the window requires two
Window slider A Window slider B
window sliders, use the bolt to fasten the
window sliders once they are adjusted to
the proper length.
Note: Once the Exhaust Hose assembly and Adjustable Window Sliderare prepared,
choose from one of the following two installation methods.
Type 1: Hung Window Installation
Foam seal B
(Adhesive type-shorter)
Foam seal C
(Non-adhesive type)
Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown.
Security Bracket
2 Screws
If desired, install the securitybracket with 2 screws as shown.
Foam seal A
(Adhesive type)
Window slider A
Window slider B (if required)
Insert the window slider assembly into the window opening.
Insert the window slider adaptor into the hole of the window slider.
Cut the non-adhesive foam seal C strip to match the width of the window. Insert the seal between the glass and the window frame to prevent airand insects from getting into the room.
Type 2: Sliding Window Installation
Installation
Foam seal B
(Adhesive type-shorter)
Foam seal A
(Adhesive type)
Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown.
Security Bracket
Window slider B (if required)
Window slider A
Insert the window slider assembly into the window opening.
Foam seal C
(Non-adhesive type)
Cut the non-adhesive foam seal C strip to match the window height. Insert the foamseal between the glass and the window frame to prevent airand insects from getting into the room.
2 Screws
If desired, install the securitybracket with 2 screws as shown.
Insert the window slider adaptor into the hole of the window slider.
Note: To ensure proper function, DO NOT overextend or bend the hose. Make sure that there is no obstacle around the air outlet of the exhaust hose (in the range of 500mm) in order to the exhaust system works properly. All the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall prevail.
Operation
(3s reset filter)
WiFi button
Used to initiate the WiFi connection mode. For the first time to use WiFi function, press the WiFi button for 3 seconds to initiate the WiFi connection mode. The LED DISPLAY shows 'AP' to indicate you can set WiFi connection. If connection(router) is successful within 8 minutes, the unit will exit WiFi connection mode automatically and the WiFi indicator illuminates. If connection is failure within 8 minutes, the unit exits WiFi connection mode automatically. NOTE: When you restart the WiFi function, it may take a period of time to connect tothe network automatically.
Swing button(optional)
(Applicable to the models with auto swing feature only) Used to initiate the Auto swing feature. When the operation is ON, press the SWING button can stop the louver at the desired angle.
Sleep(Eco)/Filter button
Used to initiate the SLEEP/ECO operation. NOTE: After 250 hours of operation, the filter indicator light illuminates. This feature is a reminder to clean the Air Filter for more efficient operation. Press this button for 3 seconds to cancel the reminder.
Power button
Power switch on/off.
(3s activate ion)
Timer button
Used to initiate the AUTO ON start time and AUTO OFF stop time program, in conjuction with the + & - buttons. The timer on/off indicator light illuminates under the timer on/off settings.
Fan/Ion button(Ion is optional)
Control the fan speed. Press to select the fan speed in four steps-LOW, MID, HIGH and AUTO. The fan speed indicator light illuminates under different fan settings. NOTE: Press this button for 3 seconds to initiate ION feature. The ion generator is energized and will help to remove pollen and impurities from the air, and trap them in the filter. Press it for 3 seconds again to stop the ION feature.
Mode button
Selects the appropriate operating mode. Each time you press the button, a mode is selected in a sequence that goes from AUTO, COOL, DRY, FAN and HEAT (cooling only models without).The mode indicator light illuminates under the different mode settings.
Up (+) and Down (-) buttons
Used to adjust (increasing/decreasing) temperature settings in 1°C/1°F increments in a range of 17°C/62°F to 30°C/86°F or the TIMER setting in a range of 0~24hrs. NOTE: The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other, press and hold the Up and Down buttons at the same time for 3 seconds.
9
Operation
LED display
Shows the set temperature in °C or °F and the Auto-timersettings.
While on DRY and FAN modes, it shows the room temperature.
Shows Error codes and protection code:
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E3-Condenser temperature sensor error (on some models).
E4-Display panel communication error.
E7-Zero-crossing malfunction.
P1-Bottom tray is full--Connect the drain hose and drain the collected water away.
If protection repeats,call for service.
Note: When one of the above malfunctions occurs, turn off the unit, and check
for any obstructions. Restart the unit, if the malfunction is still present, turn off
the unit and unplug the power cord. Contact the manufacturer or its service
agents or a similar qualified person for service.
Operation Instructions
COOL operation
-Press the "MODE" button until the "COOL" indicator light comes on.
-Press the ADJUST buttons "+" or "-" to select your desired room temperature. The
temperature can be set within a range of 17°C~30°C/62°F~86°F.
-Press the "FAN SPEED" button to choose the fanspeed.
HEAT operation(cooling only models without)
-Press the "MODE" button until the "HEAT" indicator light comes on.
-Press the ADJUST buttons "+" or " - " to select your desired room temperature. The
temperature can be set within a range of 17°C~30°C/62°F~86°F.
-Press the "FAN SPEED" button to choose the fan speed. For some models, the fan
speed can not be adjusted under HEAT mode. DRY operation
-Press the "MODE" button until the "DRY" indicator light comes on.
-Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor
operates at LOW speed.
-Keep windows and doors closed for the best dehumidifying effect.
-Do not put the duct to window.
DRY operation
-Press the "MODE" button until the "DRY" indicator light comes on.
-Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor
operates at LOW speed.
-Keep windows and doors closed for the best dehumidifying effect.
-Do not put the duct to window.
Operation
AUTO operation
-When you set the air conditioner in AUTO mode, it will automatically select cooling, heating (cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature.
-The air conditioner will control room temperature automatically round the temperature point set by you.
-Under AUTO mode, you can not select the fan speed.
FAN operation
-Press the "MODE" button until the"FAN " indicator light comes on.
-Press the "FAN SPEED" button to choose the fan speed. The temperature can not be adjusted.
-Do not put the duct to window.
TIMER operation
-When the unit is on, press the Timer button will initiate the Auto-off stop program, the TIMER OFF indicator light illuminates. Press the UP or down button to select the desired time. Press the TIMER button again within 5 seconds, the Auto-on start program is initiated. And the TIMER ON indicator light illuminates. Press the up or down button to select the desired Auto-on start time.
-When the unit is off, press the Timer button to initiate the Auto-on start program, press it again within five seconds will initiate the Auto-off stop program.
-Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start.
-The system will automatically revert back to display the previous temperature setting if there is no operation in a 5 seconds period.
-Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timer program.
-When the malfunctionoccurs, the Auto Start/Stop timed program will also be cancelled.
SLEEP/ECO operation
-Press this button, the selected temperature will increase(cooling) or decrease(heating) by
1°C/2°F 30 minutes.The temperature will then increase (cooling) or decrease (heating) by another 1°C/2°F after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the Sleep/Eco mode
and the unit will continue to operate as originally programmed.
NOTE: This feature is unavailabe under FAN or DRY mode.
Operation
Other features
FOLLOW ME/TEMP SENSING feature(optional)
NOTE:This feature can be activated from the remote control ONLY. The remote
control servesas a remote thermostat allowing for the precise temperature control
at its location.To activate the Follow Me/Temp Sensing feature, point the remote
control towards the unit and press the Follow Me/Temp Sensing button. The remote
display is actual temperature at its location. The remote control will send this signal
to the air conditioner every 3 minutes interval until press the Follow Me/Temp
Sensing button again. If the unit does not receive the Follow Me/Temp Sensing
signal during any 7 minutes interval, the unit will beep to indicate the Follow
Me/Temp Sensing mode has ended.
AUTO-RESTART
f the unit breaks off unexpectedly due to the power cut,it will restart with the previous function
setting automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted operation in the first 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the
air flow direction automatically (NOTE:On some models
the louver can be adjusted manually only) :
-When the Power is ON, the louver opens fully.
-Press the SWING button on the panel or remote controller to initiate the Auto swing feature. The louver willl swing up and down automatically.
-Please do not adjust the louver manually.
Water drainage
-During dehumidifying modes, remove the upper drain
Remove the upper drain plug
Continuous drain hose
plug from the back of the unit, install the drain
connector(5/8" universal female mender) with 3/4"
hose(locally purchased). For the models without drain
connector, just attach the drain hose to the hole. Place
the open end of the hose directly over the drain area in your basement floor.
Operation
-During heating pump mode, remove the lower drain plug from the back of the unit, install the drain connector
(5/8" universal female mender) with 3/4" hose(locally
purchased). For the models without drain connector,
just attach the drain hose to the hole. Place the open
end of the Hose adaptor directly over the drain area in your basement floor.
NOTE: Make sure the hose is secure so there
are no leaks.Direct the hose toward the drain,
making sure that there are no kinks that will
stop the warter flowing.Place the end of the
hose into the drain and make sure the end of
the hose is down to let the water flow smoothly.
(See Figs with . Do never let it up.(See Figs with ).
X
When the continuous drain hose is not used,
ensure that the corresponding drain plug and
knob are installed firmly to prevent leakage.
drain hose
drain hose adaptor
adaptor
Remove the lower drain plug
Continuous drain hose
drain hose adaptor
X
delivery lift <1.8m
-When the water level of the bottom tray reaches a predetermined level, the unit beeps 8 times, the digital display area shows "P1" . At this time the air
conditioning/dehumidification process will immediately
stop. However, the fan motor will continue to operate (this is normal). Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away. Reinstall the bottom drain plug and restart the machine until the "P1" symbol disappears. If the error repeats, call for service.
NOTE: Be sure to reinstall the bottom drain plug
firmly to prevent leakage before using the unit.
Maintenance
Safety Precautions
-Always unplug the unit before cleaning or servicing.
-DO NOT use .ammable liquids or chemicals to clean the unit.
-DO NOT wash the unit under running water. Doing so causes electrical danger.
-DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
Clean the Air Filter
Maintenance Tips
-Be sure to clean the air filter every
2 weeks for optimal performance.
-The water collection tray should be
Upper filter (take out)
drained immediately after P1 error occurs, and before storage to prevent mold.
lower filter A (Press the grill down slightly and pull the lower filter A out at the same time)
-In households with animals, you will have to periodically wipe down
the grill to prevent blocked airflow
due to animal hair.
lower filter B
(take out)
Remove the air filter
Clean the Unit
Clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free cloth.
Store the unit when not in use
-Drain the unit’s water collection tray according to the instructions in the following section.
-Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold.
-Turn off the appliance and unplug it.
-Clean the air filter according to the instructions in the previous section. Reinstall the clean, dry filter before storing.
-Remove the batteries from the remote control.
Be sure to store the unit in a cool, dark place. Exposure todirect sunshine or extreme heat can shorten the lifespan of the unit.
Faults Diagnosis
Please check the machine according to the following form before asking for maintenance:
Problem Possible Cause Troubleshooting
The Water Collection Tray is full.Turn off
Unit does not turnon when pressing
ON/OFF button
P1 Error Code
In COOL mode: room temperature is lower thanthe set temperature
the unit, drain the water from the Water Collection Tray and restart the unit.
Reset the temperature
Unit does not coolwell
The unit is noisyand vibrates toomuch
The air filter is blocked withdust or animal hair
Exhaust hose is not
connected or is blocked
The unit is low on refrigerant
Temperature setting is toohigh
The windows and doors inthe room are open
The room area is too large
There are heat sourcesinside the room
The ground is not level
The air filter is blocked withdust or animal hair
Turn off the unit and clean thefilter according to instructions
Turn off the unit, disconnect thehose, check for blockage and reconnect the hose
Call a service technician to inspectthe unit and top off refrigerant
Decrease the set temperature
Make sure all windows and doors are closed
Double-check the cooling area
Remove the heat sources if possible
Place the unit on a flat, level surface
Turn off the unit and clean thefilter according to instructions
The unit makes agurgling sound
This sound is caused by theflow of refrigerant insidethe unit
This is normal
Design and Compliance Notes
Design Notice
In order to ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice.
Energy Rating Information
The Energy Rating for this unit is based on an installation using an un-extended exhaust duct
without adapters A or B (as shown in the Installation section of this manual).
Unit Temperature Range
Mode Temperature Range
Cool 17-35°C (62-95°F)
Dry
Heat(pump heat mode)
Heat(electrical heat mode)
13-35°C (55-95°F)
5-30°C (41-86°F)
30°C (86°F)
Sociable Remark
When using this dehumidifier in the European countries, the following information must be followed:
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separatelyfor special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste.For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user. B) When buying a new product, the retailer will take back the old product at least free of charge. C) The manufacture will take back the old appliance for disposal at least free of charge to the user. D) As old products contain valuable resources, they can be sold to scrap metal dealers. Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.
Midea
90
90
90
Loading...