Midea RG70E2(2)/BGEFU1, RG70E3(2)/BGEF, RG70E2(2)/BGEF User Manual

CR193-RG70E2(2)BGEU1 16117000001054 20171013
AIR CONDITIONER
REMOTE CONTROLLER ILLUSTRATI ON
Than k yo u ve ry m uc h fo r pur ch as in g ou r ai r condi ti on er. Plea se r ea d th is o wner' s ma nu al c ar ef ully be fo re u si ng your a ir c on di ti oner. Ma ke s ur e to s av e th is manu al f or futu re r ef er en ce .
The de si gn a nd s pe cific at io ns a re s ub ject to c ha ng e wi th out pri or n ot ic e for pr od uc t im pr oveme nt . Co ns ul t wi th the sa le s ag en cy o r manuf ac tu re r for de ta il s.
1
CONTENTS
2
Model
Rated Voltage
8m
3.0V(Dry batteries R03/LR03×2)
RG70E2(2)/BGEFU1, RG70E3(2)/BGEF, RG70E2(2)/BGEF
Model: RG70E2(2)/BGEFU1 RG70E2(2)/BGEF
Remote Controller Specifications
Environment
Signal Receiving Range
1
2
4
5
3
9
10 11 12
13
8
6
7
1
2
3
4
ON/OFF Button( )
Turns the air conditioner ON and OFF.
Operation of buttons
Temp Up Button( )
O O
Decreases temperature in 1 C(1 F)
O O
increments. Min. temperature is 16 C(60 F).
Temp Down Button( )
O O
Increases temperature in 1 C(1 F)
O O
increments. Max. temperature is 30 C(86 F).
NOT E
Whe n the air c ondit ioner o perat es unde r hea ting mo de with t he set te mpera ture of
O O
16 C( 60 F) , pr es si ng b ut to n tw ice in one s econd w ill act ivate 8 D egree h eatin g. The i ndoor u nit dis play sh ows FP .
,,
,,
Scrolls through operation modes as follows:
Mode Button
AUTO
COOL
DRY
HEAT
FAN
NOT E:Pl eas e do not se lect HE AT mode if t he mac hine yo u purch ased is c oolin g only ty pe. Hea t mode is n ot supp orted b y the coo ling on ly app lianc e.
Used to enter the energy efficient mode. Under cooling mode, press this button, the air conditioner will automatically operate at
O O
24 C(75 F), with auto fan speed.
ECO Button
1
2
6
7
7
8
9
9
13
Handling the remote controller ......................................................
Remote controller Specifications...................................................
Operation of buttons ............ .........................................................
Indicators on LCD ..........................................................................
How to use the buttons .................................................................
AUTO/COOL operation....................................................................
DRY/FAN operation.........................................................................
HEAT operation ..............................................................................
Setting the Timer function .............................................................
Temp
Mode Fan
Swing
Direct
OK
Timer
Super
Options
NOTE:
Pressing the ECO button, or modifying the mode or adjusting the set temperature to
O O
less than 24 C(75 F) will stop ECO operation. The ECO operation will be stopped automatically after 8 hours. Under ECO operation, the set
O O
temperature should be 24 C(75 F) or more, it may result in insufficient cooling. If you feel uncomfortable, just press the ECO button again to stop it.
Press and hold UP and DOWN buttons together for 3 seconds will alternate the tem-
O O
perature display between the C & F scale.
o o o o
-5 C~60 C(23 F~140 F)
5
Timer Button
Press this button to initiate the auto-on/ auto-off time sequence.
3
4
7
8
Operation of buttons
Do Not Disturb Button( )
Fan Button
You can not switch the fan speed in AUTO or DRY mode.
Press Fan, MODE, Sleep, ON/OFF ,ECO or Gear button will cancel the Silent function.
NOT E
Hold down this button for at least 2 seconds to activate/cancel Silent mode. Due to low frequency operation of compressor, it may result in insufficient cooling and heating capacity (applicable to the air conditioner with Silent feature only)
Operation of buttons
9
10
11
Swing Button(for RG70E(2) series only)
OK Button
Direct Button(for RG70E(2) series only)
Used to confirm the optional functions.
Used to stop or start horizontal louver movement. The louver will swing up and down automatically.
Used to set the desired air flow direction. The louver changes 6 degree in angle for each press.
Options Button
12
Press this button to select the air conditioner function in a sequence of following:
Sel f clean
Sle ep
Fol low me
Fre sh
Press the Options button to select the desired function, the selected symbol will flash on the display area, then press the OK button to confirm.
Rep ellen t
FRESH function( )
When the FRESH function is initiated, the Ionizer/Plasma Dust Collector(depending on models) is energized and will help to remove pollen and impurities from the air.
FOLLOW ME function( )
Whe n the Fol low Me fu nctio n is acti vated , the r emote d ispla y is actu al temp eratu re at it s locat ion. Th e re mo te c on tr ol will s end thi s signa l to the ai r condi tione r every 3 min utes in terva l until p ress th e FOLLO W ME bu tton ag ain.
Press this button to turn off the indoor screen display, and also turn off the Air conditioner buzzer, the fan speed shifts to low, which create a comfortable and quiet environment. Press it again to cancel this function. Under Do Not Disturb mode, the display will illuminate for 10 seconds while adjusting the mode, set temperature or fan speed, etc.
2
9
10 11 12
13
8
Temp
Mode Fan
Swing
Direct
OK
Timer
Super
Options
1
4
5
3
6
7
Selects fan speeds in the following order:
AU g
g
20%
60%
40%
80%
F%.
g
g
g
Press the Temp or Temp button to increase/decrease the fan speed in 1% increments.
6
Super Button
Press this button under cooling operation,
O o
the set temperature will change to 17 C(62 F), the fan speed shift to high and bring faster cooling operation. Press this button under heating operation,
O o
the set temperature will change to 30 C(86 F), the fan speed shift to high and bring faster heating operation.
NOTE:
This function is not available under AUTO, DRY,FAN,Self Clean or Comfort mode. Press MODE,FAN,SLEEP or ECO button will cancel Super function.
Model: RG70E3(2)/BGEF
1
2
4
5
3
9
10 11 12
13
8
6
7
Temp
Mode Fan
OK
Timer
Super
Options
Swing Button(for RG70E3(2)/BGEF only)
Used to stop or start horizontal louver move­ment or set the desired up/down air flow direction. The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the louver will swing up and down automatically.
Swing Button(for RG70E3(2)/BGEF only)
Used to stop or start vertical louver movement and set the desired left/right air flow direction. The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the louver will swing left and right automatically.
Model: RG70E2(2)/BGEFU1 RG70E2(2)/BGEF
Loading...
+ 6 hidden pages