Warning notices: Before
using this product, please
read this manual carefully
and keep it for future
reference.
The design and
specifications are subject to
change without prior notice
for product improvement.
Consult with your dealer or
manufacturer for details.
Inside you will find many helpful hints on how to use and maintain your air conditioner
properly. Just a little preventive care on your part can save you a great deal of time
and money over the life of your air conditioner. You’ll find many answers to common
problems in the troubleshooting tips - you should be able to fix most of them quickly
before calling service. These instructions may not cover every possible condition of
use, so common sense and care for safety is required when installing, operating and
maintaining this product.
CAUTION
• Contact the authorized service technician for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intented for use by young children or infirm persons
without supervision.
• Young children should be supervised to ensure that they do not play with the air
conditioner.
• If the power cord needs to be replaced, please contact our consumer service and
look for an authorized technician.
• Electrical installation must be performed in accordance to national regulation
standards by qualified personnel only.
Page 2
Safety Precautions
To prevent injury to the user or other people and property damage, the instructions
shown here must be followed. Incorrect operation due to ignoring of instructions may
cause harm or damage. The level of risk is shown by the following indications.
This symbol indicates the possibility of death or serious injury.
WARNING
This symbol indicates the possibility of injury or damage to property.
CAUTION
WARNING
• Plug in power plug properly.
Otherwise, it may cause electric shock or fire due to excess heat generation.
• Do not modify power cord length or share the outlet with other appliances.
It may cause electric shock or fire due to overheat.
• Always ensure effective grounding.
Incorrect grounding may cause electric shock.
• Unplug the unit if strange sounds, smell, or smoke comes from it.
A damaged product may cause fire and electric shock.
• Keep firearms away.
• Ventilate room before operating the air conditioner if there is a gas leakage from
another appliance.
• Do not operate or stop the unit by inserting or pulling out the power plug.
• Do not operate with wet hands or in very humid enviroments.
It may cause electric shock.
• Do not allow water to touch into electric parts.
It may cause failure or electric shock.
• Do not use the socket if it is loose or damaged.
It may cause fire and electric shock.
• Do not use or keep the power cord close to heating appliances.
It may cause fire and electric shock.
• Do not place the power cord close to heating appliances.
It may cause fire and electric shock
• Do not disassemble or modify unit.
It may cause failure and electric shock.
• Do not damage or use an unspecified power cord.
It may cause fire and electric shock.
If the power cord is damaged, it must be replaced by the manufacturer or an
authorised service centre or a similarly qualified person in order to avoid a hazard.
Precautions
Safety
Page 3
Precautions
Safety
WARNING
• Do not direct airflow straight into people to avoid possible health hazard.
• Always install circuit breaker and a dedicated power circuit.
Incorrect installation may cause fire and electric shock.
• Do not open the unit during operation.
It may cause electric shock.
• Do not use the power cord near flammable gas or combustibles, such as gasoline,
benzene, thinner, etc.
It may cause an explosion or fire.
CAUTION
• When the air filter is to be removed, do not touch the metal parts of the unit.
It may cause an injury.
• When the unit needs cleaning, switch off, and turn off the circuit breaker.
Do not clean unit when power is on as it may cause fire and electric shock, it may
cause an injury.
• Stop operation and close the window in storm or hurricane.
Operation with windows open may cause water leak into the room.
• Do not place obstacles around air-inlets or inside of air-outlet.
It may cause failure or accident.
• Do not use strong detergent such as wax or thinner but a soft cloth, or else risk
damaging the product.
• Use caution when unpacking and installing. Sharp edges could cause injury.
• Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
• Do not put a pet or house plant where it will be exposed to direct air flow.
This could injure the pet or plant.
• Hold the plug by the head of the power plug when taking it out.
It may cause electric shock and damage.
• Ensure that the installation is properly secured under risk of the product falling.
• Do not place heavy object on the power cord and ensure that the cord is not
compressed.
There is danger of fire or electric shock.
• If water enters the unit, turn the unit off at the power outlet and switch off the
circuit breaker. Isolate supply by taking the power-plug out and contact a qualified
service technician.
• Ventilate the room well when used together with a stove, etc.
An oxygen shortage may occur.
• Do not use for any other purpose than room comfort.
Do not use this air conditioner to preserve precision devices, food, pets, plants,
and art objects. It may cause deterioration.
• Turn off the main power switch when not using the unit for a long time.
• Always insert the filters securely. Clean filter once every two weeks.
Operation without filters may cause failure.
• Do not drink water drained from air conditioner.
Page 4
Precautions
Safety
NOTE
The power supply cord with this
air conditioner contains a current
detection device designed to reduce
the risk of fire.
Please refer to the section Operation of
Current Device for details.
In the event that the power supply cord
is damaged, it can not be repaired.It
must be replaced with a cord from the
manufacturer.
WARNING - For your safety
• Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
• Avoid fire hazard or electric shock.
Do not use an extension cord or an
adaptor plug. Do not remove any
prong from the power cord.
Grounding type wall receptacle
Do not, under any
circumstances, cut,
remove or bypass
the groundig prong.
WARNING - Electrical Information
The complete electrical rating of
your new room air conditioner is
stated on the serial plate. Refer to the
rating when checking the electrical
requirements.
• Be sure the air conditioner is
properly grounded. To minimize
shock and fire hazards, proper
grounding is important. The power
cord is equipped with a three-prong
grounding plug for protection against
shock hazards.
• Your air conditioner must be
used in a properly grounded wall
receptacle. If the wall receptacle
you intend to use is not adequately
grounded or protected by a time
delay fuse or circuit breaker, have a
qualified electrician install the proper
receptacle.
• Ensure the receptacle is accessible
after the unit installation.
• Do not run air conditioner without
outside protective cover in place.
This could result in mechanical
damage within the air conditioner.
• Do not use an extension cord or an
adapter plug.
Power supply cord with 3-prong
grounding plug and current detection
device
Page 5
Precautions
Safety
WARNING - Prevent Accidents
To reduce the risk of fire, electrical shock, or injury to persons when using your air
conditioner, follow basic precautions, including the following:
• Be sure the electrical service is adequate for the model you have chosen. This
information can be found on the serial plate, which is located on the side of the
cabinet and behind the grille.
• If the air conditioner is to be installed in a window, you will probably want to clean
both sides of the glass first. If the window is a triple-track type with a screen panel
included, remove the screen completely before installation.
• Be sure the air conditioner as been securely and correctly in stalled according to
the installation instructions in this manual. Save this manual for possible future use
in removing or installing this unit.
• When handling the air conditioner, be careful to avoid cuts from sharp metal fins
on front and rear coils.
Operation of Current Device
The power supply cord contains a current device that senses damage to the power
cord. To test your power supply cord as follows:
1. Plug in the air conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST
button, you will notice a click as the RESET button pops out.
3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products
this it also indicated by a light on the plug head.)
NOTES
• Do not use this device to turn the unit on or off.
• Always make sure the RESET button is pushed in for correct operation.
• The power supply must be replaced if it fails reset when either the TEST button is
pushed, or it can not be reset. Please contact Customer Service.
• If power supply cord is damaged, it can not be repaired. It MUST be replaced with
a new cord - please contact Customer Service.
Page 6
Unit Specifications
1
Specifications
and Features
Unit
MODEL
Power supplyPh-V-Hz
Rated CapacityBtu/h
Rated EERBtu/w.h,w/w
Cooling
Moisture Removal L/h
Max. input consuptionW
Max. currentA
Starting currentA
Outdoor noise level (Hi/Med/Lo)dB(A)
Plug type (NEMA#)
Power cord length
Control type
Operating
temperature
Application area
(Cooling Standard)
Application area (Cooling EPA)sp.ft
Dimension (W*D*H)
Packing (W*D*H)
Net/Gross weight
Loading quantity 40’HQPieces
Window
Opening
Rated CEERBtu/w.h,w/w
Rated inputW
Rated currentA
Standby powerW
mm
ft
Indoor
(cooling/heating)
Outdoor
(cooling/heating)
Width (Min/Max)in
Height (Min/Max)in
°C
°F
°C
°F
m
sq.ft
mm
in
mm
in
kg
lb
2
MWB06CW71MWB08CW71MWB10CW71
1Ph, 115V-, 60Hz1Ph-115V-60Hz1Ph-115V-60Hz
6000800010000
12,212,012,0
12,112,012,0
490666833
4.55.97.5
0.90.91.0
0,711,1
700830992
6,589,79
21.02935
63.2/60.8/58.164.5/62.6/59.266.7/64.6/61.7
5-15P5-15P5-15P
198019801980
6.56.56.5
Remote ControlRemote ControlRemote Control
17-32/---17-32/---17-32/---
62-9062-9062-90
18-43/---18-43/---18-43/---
64-10964-10964-109
8-1211-1613-20
86-129118-172140-215
150-250300-350400-450
471*450*340471*494*340482x595x372
18.5*17.7*13.418.5*19.5*13.419x23.5x14.6
561*502*370561*545*370557x636x430
22.09*19.8*14.622.09*21.49*14.621.9x24.1x16.9
20.5/23.622.2/25.327.7/31.2
45.1/52.048.8/55.761.1/68.8
668576424
23/3623/3623/36
141415,5
Page 7