Midea Mwb06cw71-1 Owner's Manual

Window Type
Rated voltage: 115V Rated power: 490 ~ 833W Frequency: 60Hz Capacity: 6000 ~ 10000BTU/h
en
USER MANUAL
Warning notices: Before using this product, please read this manual carefully and keep it for future reference.
The design and specifications are subject to change without prior notice for product improvement. Consult with your dealer or manufacturer for details.
version A - 04 - 2017
MWB10CW71 MWB08CW71 MWB06CW71
www.midea.com
Owner’s Manual
0
Safety Precautions .................................................................................... 3
1
Unit Specifications .................................................................................... 7
2
Operating Instructions ............................................................................. 8
3
Installation Instructions .......................................................................... 12
4
Care and Cleaning .................................................................................... 19
5
Troubleshooting Tips ............................................................................. 20
Read This Manual
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the troubleshooting tips - you should be able to fix most of them quickly before calling service. These instructions may not cover every possible condition of use, so common sense and care for safety is required when installing, operating and maintaining this product.
CAUTION
• Contact the authorized service technician for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intented for use by young children or infirm persons without supervision.
• Young children should be supervised to ensure that they do not play with the air conditioner.
• If the power cord needs to be replaced, please contact our consumer service and look for an authorized technician.
• Electrical installation must be performed in accordance to national regulation standards by qualified personnel only.
Page 2
Safety Precautions
To prevent injury to the user or other people and property damage, the instructions shown here must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The level of risk is shown by the following indications.
This symbol indicates the possibility of death or serious injury.
WARNING
This symbol indicates the possibility of injury or damage to property.
CAUTION
WARNING
• Plug in power plug properly. Otherwise, it may cause electric shock or fire due to excess heat generation.
• Do not modify power cord length or share the outlet with other appliances. It may cause electric shock or fire due to overheat.
• Always ensure effective grounding. Incorrect grounding may cause electric shock.
• Unplug the unit if strange sounds, smell, or smoke comes from it. A damaged product may cause fire and electric shock.
• Keep firearms away.
• Ventilate room before operating the air conditioner if there is a gas leakage from another appliance.
• Do not operate or stop the unit by inserting or pulling out the power plug.
• Do not operate with wet hands or in very humid enviroments. It may cause electric shock.
• Do not allow water to touch into electric parts. It may cause failure or electric shock.
• Do not use the socket if it is loose or damaged. It may cause fire and electric shock.
• Do not use or keep the power cord close to heating appliances. It may cause fire and electric shock.
• Do not place the power cord close to heating appliances. It may cause fire and electric shock
• Do not disassemble or modify unit. It may cause failure and electric shock.
• Do not damage or use an unspecified power cord. It may cause fire and electric shock. If the power cord is damaged, it must be replaced by the manufacturer or an authorised service centre or a similarly qualified person in order to avoid a hazard.
Precautions
Safety
Page 3
Precautions
Safety
WARNING
• Do not direct airflow straight into people to avoid possible health hazard.
• Always install circuit breaker and a dedicated power circuit. Incorrect installation may cause fire and electric shock.
• Do not open the unit during operation. It may cause electric shock.
• Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause an explosion or fire.
CAUTION
• When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury.
• When the unit needs cleaning, switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury.
• Stop operation and close the window in storm or hurricane. Operation with windows open may cause water leak into the room.
• Do not place obstacles around air-inlets or inside of air-outlet. It may cause failure or accident.
• Do not use strong detergent such as wax or thinner but a soft cloth, or else risk damaging the product.
• Use caution when unpacking and installing. Sharp edges could cause injury.
• Do not clean the air conditioner with water. Water may enter the unit and degrade the insulation. It may cause an electric shock.
• Do not put a pet or house plant where it will be exposed to direct air flow. This could injure the pet or plant.
• Hold the plug by the head of the power plug when taking it out. It may cause electric shock and damage.
• Ensure that the installation is properly secured under risk of the product falling.
• Do not place heavy object on the power cord and ensure that the cord is not compressed. There is danger of fire or electric shock.
• If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.
• Ventilate the room well when used together with a stove, etc. An oxygen shortage may occur.
• Do not use for any other purpose than room comfort. Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration.
• Turn off the main power switch when not using the unit for a long time.
• Always insert the filters securely. Clean filter once every two weeks. Operation without filters may cause failure.
• Do not drink water drained from air conditioner.
Page 4
Precautions
Safety
NOTE
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire.
Please refer to the section Operation of Current Device for details.
In the event that the power supply cord is damaged, it can not be repaired.It
must be replaced with a cord from the manufacturer.
WARNING - For your safety
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
• Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
Grounding type wall receptacle
Do not, under any circumstances, cut, remove or bypass the groundig prong.
WARNING - Electrical Information
The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
• Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
• Ensure the receptacle is accessible after the unit installation.
• Do not run air conditioner without outside protective cover in place. This could result in mechanical damage within the air conditioner.
• Do not use an extension cord or an adapter plug.
Power supply cord with 3-prong grounding plug and current detection device
Page 5
Precautions
Safety
WARNING - Prevent Accidents
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:
• Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille.
• If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a screen panel included, remove the screen completely before installation.
• Be sure the air conditioner as been securely and correctly in stalled according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.
• When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
Operation of Current Device
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord as follows:
1. Plug in the air conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by a light on the plug head.)
NOTES
• Do not use this device to turn the unit on or off.
• Always make sure the RESET button is pushed in for correct operation.
• The power supply must be replaced if it fails reset when either the TEST button is pushed, or it can not be reset. Please contact Customer Service.
• If power supply cord is damaged, it can not be repaired. It MUST be replaced with a new cord - please contact Customer Service.
Page 6
Unit Specifications
1
Specifications
and Features
Unit
MODEL
Power supply Ph-V-Hz
Rated Capacity Btu/h
Rated EER Btu/w.h,w/w
Cooling
Moisture Removal L/h
Max. input consuption W
Max. current A
Starting current A
Outdoor noise level (Hi/Med/Lo) dB(A)
Plug type (NEMA#)
Power cord length
Control type
Operating temperature
Application area (Cooling Standard)
Application area (Cooling EPA) sp.ft
Dimension (W*D*H)
Packing (W*D*H)
Net/Gross weight
Loading quantity 40’HQ Pieces
Window Opening
Rated CEER Btu/w.h,w/w
Rated input W
Rated current A
Standby power W
mm
ft
Indoor (cooling/heating)
Outdoor (cooling/heating)
Width (Min/Max) in
Height (Min/Max) in
°C
°F
°C
°F
m
sq.ft
mm
in
mm
in
kg
lb
2
MWB06CW71 MWB08CW71 MWB10CW71
1Ph, 115V-, 60Hz 1Ph-115V-60Hz 1Ph-115V-60Hz
6000 8000 10000
12,2 12,0 12,0
12,1 12,0 12,0
490 666 833
4.5 5.9 7.5
0.9 0.9 1.0
0,7 1 1,1
700 830 992
6,5 8 9,79
21.0 29 35
63.2/60.8/58.1 64.5/62.6/59.2 66.7/64.6/61.7
5-15P 5-15P 5-15P
1980 1980 1980
6.5 6.5 6.5
Remote Control Remote Control Remote Control
17-32/--- 17-32/--- 17-32/---
62-90 62-90 62-90
18-43/--- 18-43/--- 18-43/---
64-109 64-109 64-109
8-12 11-16 13-20
86-129 118-172 140-215
150-250 300-350 400-450
471*450*340 471*494*340 482x595x372
18.5*17.7*13.4 18.5*19.5*13.4 19x23.5x14.6
561*502*370 561*545*370 557x636x430
22.09*19.8*14.6 22.09*21.49*14.6 21.9x24.1x16.9
20.5/23.6 22.2/25.3 27.7/31.2
45.1/52.0 48.8/55.7 61.1/68.8
668 576 424
23/36 23/36 23/36
14 14 15,5
Page 7
Loading...