Midea MPPD12HRN1 User Manual

Midea Window and Portable Air Conditioners give you total
exibility and maximum economy.
30 million units a year sold worldwide – that should make you feel comfortable.
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Heating
Heating
Heating
EXAMPLE
=
Cooling
Heating
2. Copy & paste correct heating star rating arch on top of cooling arch using the guides to help
3. Group together final arch and COPY & PASTE into the relevant airconditioner energy rating label
The more stars the more energy efficient
Cooling
The more stars the more energy efficient
Cooling
The more stars the more energy efficient
Cooling
The more stars the more energy efficient
Cooling
The more stars the more energy efficient
The more stars the more energy efficient
The more stars the more energy efficient
Cooling
The more stars the more energy efficient
The more stars the more energy efficient
Heating
Heating
Slinger-up System
MODEL MWF-05CB4 MWF-07CB4 MWF-09CB4 MWF-12CB4 MWF-07HB4 MWF-09HB4 MWF-12HB4 MWF18HB4
COOLING ONLY HEATING & COOLING
Remote Control
Your easy to operate remote control* puts comfort at your fingertips.
Gold Fin Condenser
Rotary Compressor
The rotary compressor reduces noise and vibration.
Removable Panel
The front panel is easily removed for periodic cleaning.
Fresh Air Switch
Pressing the “Fresh Air” button draws in fresh air from outside, as air pressure expels air from inside.
All refrigerated air conditioners develop condensate water when in cooling mode. Midea Window/ Wall units use a “slinger” fan to agitate this condensate onto the condenser to increase the efficiency of the unit. This means that the bulk of the condensate is used up; reducing the need to drain the unit.*
5 Year Warranty
A five year warranty provides further peace of mind.**
Power supply
V-Hz-Ph220-240V~50Hz
1Ph
220-240V~50Hz
1Ph
220-240V~50Hz
1Ph
220-240V~50Hz
1Ph
220-240V~50Hz
1Ph
220-240V~50Hz
1Ph
220-240V~50Hz
1Ph
220-240V~50Hz
1Ph
Capacity W 1600 2130 2600 3600 2230 2600 3500 5500
Input W 500 640 790 1090 660 790 1050 1730
Cooling
Rated current
A 2.4 2.9 3.6 5.0 3.0 3.6 4.8 7.7
AEER W/W 3.19 3.32 3.28 3.30 3.37 3.28 3.33 3.17
Capacity W 1970 2350 3200 4700
Input W 580 700 960 1470
Heating
Rated current
A 2.7 3.2 4.4 6.5
ACOP W/W 3.39 3.35 3.33 3.19
Star Rating
Cooling
Cooling
1.5 2.0 2.0 2.0 2.0 2.0 2.0 1.5
Heating
Cooling
Cooling
Cooling
Cooling
Heating
2.0 2.0 2.0 1.5
Cooling
Heating
Cooling
Heating
Heating
Heating
Moisture Removal L/h 0.7 0.8 1.0 1.2 0.8 1.0 1.2 1.8
Max. input consumption W 650 850 1100 1600 850 1100 1600 2450
Max. current A 3.0 3.8 5.0 6.8 3.8 5.0 6.8 12.5
Starting current A 11 15 16 20.1 15 16 25.1 36
Plug type A 10 10 10 10 10 10 10 15
Control Type Remote Remote Remote Remote Remote Remote Remote Remote
Compressor Type Rotary Rotary Rotary Rotary Rotary Rotary Rotary Rotary
Dual Drainage
Alternative drainage points provide versatility for different drainage
The Golden hydrophilic condenser improves the heating efficiency in Reverse Cycle models by accelerating the defrosting process. The special anti-corrosive golden coating on the condenser also aids in withstanding the effects of salty air, rain and other corrosive elements by allowing contaminated water on the coil to run off more quickly reducing the corrosive effect to the coil. Heat exchange performance is much longer lasting.
*There will always be situations of high humidity where the condensate produced may have to be drained away. **Some exclusions apply. Specifications based on Testing conditions as specified in AS/NZ3823 1.1.1998. Cooling: Indoor DB 27°C WB 19°C, Outdoor DB 35°C WB 24°C. Heating: Indoor DB 20°C, Outdoor DB 7°C. Star Rating, Comparative
situations.
Automatic Left to Right Airflow
Gives even air distribution.
Sliding Chassis
The casing slides out easily to allow simple installation and servicing.
SSS Service System
The SSS system is a designated help line (1300 726 002) which saves you having to organise servicing through the original reseller or find an appointed service repairer. After taking your purchase details and establishing the problem, the help line will contact an appointed service centre for you and arrange for the work to be done.
Indoor air flow (Hi/Mi/Lo) L/Sec 108/95/84 105/95/86 127/113/100 197/180/158 105/95/86 127/113/100 197/180/158 227/200/175
Indoor noise level (Hi/Mi/Lo)
Outdoor noise level (Sound pressure)
Outdoor noise level (Sound power)
dB(A) 49/46/43 51/48/45 51/48/45 53/50/47 51/48/45 51/48/45 54/51/48 59/56/53
dB(A) 58/54/51 58/55/52 58/55/52 58/56/53 58/55/52 58/55/52 58/56/53 66/62/59
dB(A) 66 66 67 67 66 67 68 74
Refrigerant type g R410A/325g R410A/430g R410A/480g R410A/670g R410A/530g R410A/755g R410A/870g R410A/1280g
Operation temp °C 17-32 17-32 17-32 17-32 17-32/0-27 17-32/0-27 17-32/0-27 17-32/0-27
Ambient temp (cooling/heating)
°C 18-43/--- 18-43/--- 18-43/--- 18-43/--- 18-43/-5-24 18-43/-5-24 18-43/-5-24 18-43/-5-24
Dimension(W*D*H) mm 445x415x320 600x560x380 600x560x380 660x680x428 600x560x380 600x560x380 660x680x428 660x780x428
Weight (net/Gross) Kg 25/27 35/39 36/40 46/50 34/38 36/40 47/51 63/72