Midea Mpf08cr71-1, Mpf12cr71-1, Mpf14cr71-1, Mpf10cr71-1 Owner's Manual

EasyCool Portable
MPF
Rated voltage: 115V Rated power: 900 ~ 1575W Frequency: 60Hz Capacity: 8000 ~ 14000BTU/h
en
USER MANUAL
Warning notices: Before using this product, please read this manual carefully and keep it for future reference.
The design and specifications are subject to change without prior notice for product improvement. Consult with your dealer or manufacturer for details.
version A - 03 - 2017
MPF08CR71
MPF10CR71 MPF12CR71 MPF14CR71
www.midea.com
Owner’s Manual
0
Safety Precautions ............................................................................ 3
1
Unit Specifications and Features ................................................... 5
Operating Instructions ..................................................................... 7
2
Installation Instructions ................................................................... 12
3
Care and Cleaning ............................................................................ 17
4
Troubleshooting Tips ....................................................................... 18
5
Remote Control Operating Instructions ..................................... 19
6
Sociable Remark .............................................................................. 28
7
Warranty ............................................................................................ 29
8
Read This Manual
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips - you should be able to fix most of them quickly before calling service. These instructions may not cover every possible condition of use, so common sense and care for safety is required when installing, operating and maintaining this product.
CAUTION
• Contact the authorized service technician for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intented for use by young children or infirm persons without supervision.
• Young children should be supervised to ensure that they do not play with the air conditioner.
• If the power cord needs to be replaced, please contact our consumer service and look for an authorized technician.
• Electrical installation must be performed in accordance to national regulation standards by qualified personnel only.
Page 2
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
WARNING
This symbol indicates the possibility of injury or damage to property.
CAUTION
WARNING
Please read through these instructions before you start the installation process. Improper installation can cause damage to the unit, your personal property, and also poses a personal safety hazard.
• Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
• Use only the included accessories and parts, and specified tools for the installation. Using non-standard parts can cause water leakage, electrical shock, fire, and injury or property damage.
• Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord is equipped with a three-prong grounding plug to protect against shock. Voltage information can be found on the side of the unit, behind the grille.
• Install the unit in on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
• The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
• DO NOT modify the length of the power cord or use an extension cord to power the unit. DO NOT share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
• DO NOT install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
• DO NOT install the unit in a location that may be exposed to combustible gas, as this could cause fire.
• The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects, as these could cause tipping.
• DO NOT operate a unit that has been dropped or damaged.
• Only use the included accessories and specified parts for installation. Using nonstandard parts can cause water leakage, electrical shock, fire, and injury or property damage.
Precautions
Safety
Page 3
Precautions
Safety
WARNING
• The unit must be kept free from obstruction to ensure proper function.
• DO NOT allow children to play with the air conditioner. Children must be supervised around the unit at all times.
• If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
• In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
CAUTION
• This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be applicable for the European Countries)
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. (be applicable for other countries except the European Countries)
Children should be supervised to ensure that they do not play with the appliance.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
• Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
• Do not install the appliance in a location that may be exposed to combustible gas.
• If combustible gas accumulates around the unit, it may cause fire.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
• Do not operate unit with a damaged cord or plug. Discard unit or return to an authorized service facility for examination and/or repair.
• To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
• The appliance shall be installed in accordance with national wiring regulations.
• Contact the authorised service technician for repair or maintenance of this unit.
• Contact the authorised installer for installation of this unit.
• When there are wide differences between “USER’S MANUAL” and “Remote Controller Illustration” on function description, the description on “USER’S MANUAL“ shall prevail.
• Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
Page 4
Unit Specifications and Features
Preparation
Control panel
Upper air filter
(behind the grille)
Horizontal louver blade
Handle (both sides)
Upper air intake
Drain outlet
Air outlet
Lower air filter
Lower air intake
Power plug socket
(only for pump heating mode)
Drain outlet
1
Specifications
and Features
Unit
Caster
Power cord outlet
Power cord buckle
Bottom tray drain outlet
RearFront
Design and Compliance Notes
Design Notice:
In order to ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice.
Energy Rating Information:
The Energy Rating for this unit is based on an installation using an un-extended exhaust duct without adapters A or B (as shown in the Installation section of this manual).
Unit Temperature Range:
Mode Temperature Range
Cool 17°C ~ 35°C (62°F ~ 95°F)
Dry 13°C ~ 35°C (55°F ~ 95°F)
Heat (pump heat mode) 5°C ~ 30°C (41°F ~ 86°F)
Heat (electrical heat mode)  30°C (86°F)
Page 5
Specifications
and Features
Unit
Specifications
MODEL MPF08CR71 MPF10CR71 MPF12CR71 MPF14CR71
Power supply Ph-V-Hz
Capacity Btu/h
Rated input
Cooling
Moisture removal (26.7/20.9°C)
Moisture removal (35/28.3°C)
Starting current A
Indoor side air flow (Hi)
Indoor side noise level (Hi)
Refrigerant type ozs
Plug type (NEMA#)
Control type
Operating temperature (room temp.)
Application area (Cooling Standard)
Application area (Cooling EPA)
Dimension (W*D*H)
Net/Gross weight
Rated current
EER
W
A
W/W
Btu/W.h
L/h
L/h
m
CFM
dB(A)
°C
°F
m
sq.ft
ft
mm
in
kg
lb
1Ph, 115V-, 60Hz 1Ph, 115V-, 60Hz 1Ph, 115V-, 60Hz 1Ph, 115V-, 60Hz
8000 10000 12000 14000
900 1130 1350 1575
8 10 12 11.8
2.6 2.6 2.6 2.6
8.9 8.9 8.9 8.9
1.2 1.5 1.8 2.1
1.6 2.1 2.5 2.9
30.3 43 48.8 48.8
3
/h
300 300 350 380
176 176 206 224
55 55 56 56
R410A/9.17 R410A/10.58 R410A/13.76 R410A/20.46
5-15P 5-15P 5-15P 5-15P
Remote Control Remote Control Remote Control Remote Control
17 ~ 35/--- 17 ~ 35/--- 17 ~ 35/--- 17 ~ 35/---
62 ~ 95/--- 62 ~ 95/--- 62 ~ 95/--- 62 ~ 95/---
2
11-16 13-20 16-23 19-27
118-172 140-215 172-248 205-291
2
300-350 400-450 500-550 550-700
435*330*730 435*330*730 435*330*730 458*365*774
17.1*13*28.3 17.1*13*28.3 17.1*13*28.3 18*14.4*30.5
26/30.5 26/30.5 28.5/33 31/35.1
57.2/67.1 57.2/67.1 62.7/72.6 68.3/77.4
Page 6
Operating Instructions
Key Pad Features
(3s activate ion)
LED Display
2
Instructions
Operating
Swing
Control
Swing Button (optional)
(Applicable to the models with auto swing feature only) Used to initiate the Auto swing feature. When the operation is ON, press the SWING button can stop the louver at the desired angle.
Sleep (Eco)/Filter button
Used to initiate the SLEEP/ECO operation.
Sleep Mode
Auto
Timer
Fan
Speed
NOTE
After 250 hours of operation, the filter indicator light illuminates. This feature is a reminder to clean the Air Filter for more efficient operation. Press this button for 3 seconds to cancel the reminder.
Mode
Selector
Timer button
Used to initiate the AUTO ON start time and AUTO OFF stop time program, in conjuction with the + & - buttons. The timer on/off indicator light illuminates under the timer on/off settings.
Fan/Ion button (Ion is optional)
Control the fan speed. Press to select the fan speed in four steps - LOW, MID, HIGH and AUTO. The fan speed indicator light illuminates under different fan settings.
Up (+) and
Down (-) Control
Power
Button
NOTE
Press this button for 3 seconds to initiate ION feature. The ion generator is energized and will help to remove pollen and impurities from the air, and trap them in the filter. Press it for 3 seconds again to stop the ION feature.
Page 7
Instructions
Operating
LED Display
(3s activate ion)
Swing
Control
Sleep Mode
Auto
Timer
Fan
Speed
Mode button
Selects the appropriate operating mode. Each time you press the button, a mode is selected in a sequence that goes from AUTO, COOL, DRY, FAN and HEAT (cooling only models without). The mode indicator light illuminates under the different mode settings.
Up (+) and Down (-) buttons
Used to adjust (increasing/decreasing) temperature settings in 1°C/1°F increments in a range of 17°C/62°F to 30°C/86°F or the TIMER setting in a range of 0 ~ 24hrs.
NOTE
The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other, press and hold the Up and Down buttons at the same time for 3 seconds.
Power button
Power switch on/off.
Mode
Selector
Up (+) and
Down (-) Control
Power
Button
LED display
Sho
ws the set temperature in °C or °F and the Auto-timer settings. While on DRY and FAN modes, it shows the room temperature.
Shows Error codes and protection code:
E1 - Room temperature sensor error.
E2 - Evaporator temperature sensor error.
E3 - Condenser temperature sensor error
(on some models).
E4 - Display panel communication error.
E7 - Zero-crossing malfunction.
P1 - Bottom tray is full -- Connect the
drain hose and drain the collected water away. If protection repeats, call for service.
NOTE
When one of the above malfunctions occurs, turn off the unit, and check for any obstructions. Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord. Contact the manufacturer or its service agents or a similar qualified person for service.
Page 8
Operation Instructions
COOL operation
• Press the “MODE” button until the “COOL” indicator light comes on.
• Press the ADJUST buttons “+” or “-” to select your desired room temperature. The temperature can be set within a range of 17°C~30°C/62°F~86°F.
• Press the “FAN SPEED” button to choose the fanspeed.
HEAT operation
(cooling only models without)
• Press the “MODE” button until the “HEAT” indicator light comes on.
• Press the ADJUST buttons “+” or “ - “ to select your desired room temperature. The temperature can be set within a range of 17°C~30°C/62°F~86°F.
• Press the “FAN SPEED” button to choose the fan speed. For some models, the fan speed can not be adjusted under HEAT mode.
DRY operation
• Press the “MODE” button until the “DRY” indicator light comes on.
• Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor operates at LOW speed.
• Keep windows and doors closed for the best dehumidifying effect.
• Do not put the duct to window.
• Press the “FAN SPEED” button to choose the fan speed. The temperature can not be adjusted.
• Do not put the duct to window.
TIMER operation
• When the unit is on, press the Timer button will initiate the Auto-off stop program, the TIMER OFF indicator light illuminates. Press the UP or down button to select the desired time. Press the TIMER button again within 5 seconds, the Auto-on start program is initiated. And the TIMER ON indicator light illuminates. Press the up or down button to select the desired Auto-on start time.
• When the unit is off, press the Timer button to initiate the Auto-on start program, press it again within five seconds will initiate the Auto-off stop program.
• Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start.
• The system will automatically revert back to display the previous temperature setting if there is no operation in a 5 seconds period.
• Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timer program.
• When the malfunctionoccurs, the Auto Start/Stop timed program will also be cancelled.
Instructions
Operating
AUTO operation
• When you set the air conditioner in AUTO mode, it will automatically select cooling, heating (cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature.
• The air conditioner will control room temperature automatically round the temperature point set by you.
• Under AUTO mode, you can not select the fan speed.
FAN operation
• Press the “MODE” button until the ”FAN“ indicator light comes on.
SLEEP/ECO operation
Press this button, the selected temperature will increase (cooling) or decrease (heating) by 1°C/1°F 30 minutes. The temperature will then increase (cooling) or decrease (heating) by another 1°C/1°F after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the Sleep/Eco mode and the unit will continue to operate as originally programmed.
NOTE
This feature is unavailabe under FAN or DRY mode.
Page 9
Loading...