Midea Mp15hmc62-1, Mp12hmc62-1, Mp12hmb63-1, Mp12emb63-1, Mp09hmb63-1 Owner's Manual

...
SERVICE MANUAL
PTACSERIES
7,000-15,000 BTU/H
CONTENTS
1. Precaution
1-3
1.1 Safety Precaution
1.2 Warning
2. Dimensions
3. Unit Components
4. Installation Details
4.1 How to Install Unit
4.2 Care and Cleaning
4.3 Other Installations
5. Functions and Control Panel
6. Refrigerant Cycle Diagram
7. Electronic Function
7.1 Terms and Definitions
7.2 Electric Control Working Environment
7.3 Protection Function
7.4 Operation of Fan Motor
7.5 Operation of Compressor
7.6 DIP Switches and Jumper Selection
8. Operations Characteristics
8.1 Cooling Operation
8.2 Heating Operation
9. Power Connection Options
10. Troubleshooting
10.1Error Display
10.2Troubleshooting
1
1-3
3
4
5-15
5-7
7-8
9-15
16-20
21
21-25
21
22
22
22-23
24-25
25
25
25
25
25
26-27
28-33
28
28-33
www.mideaaircon.com 1
1.

Precaution

1.1
Safety Precaution

To prevent personal injury and/or property damage, follow the instructions below.

Failure to follow correct procedure may result in personal inj ury, death, and/or property damage. Before servicing unit, read this service manual.
1.2

Warning

INSTALLATION

To reduce the risk of fire or explosion, electric shock, personal injury, death, product failure, or property damage during the installation process, read and follow the warnings listed below.

Do not use a defective or underrated circuit breaker. Use a dedicated circuit on this appliance. For electrical work, contact the dealer/seller, a qualified electrician, or an authorized service center.
Do not disassemble or repair the product. Ground the product. Securely install the panel and cover of control box. Avoid improper wiring or installation. Use the correctly rated breaker and fuse. Do not modify or extend the power cable. Do not install, remove, or reinstall the unit unaccompanied. Be careful when unpacking and installing around exposed sharp edges, especially the casing edges
and the fins on the condenser and evaporator. For installation, always contact the dealer or an authorized service center. Do not install the product on a defective installation stand. Be sure the installation area does not deteriorate with age to avoid the base collapsing. Do not let the air conditioner run for a long period of time when there is high humidity and a door or
window is left open. Moisture may condense and wet or damage furniture. Do not pull out or damage the power cord during operation. Do not place anything on the power cable. Do not plug or unplug the power plug during operation. Do not touch/operate the product with wet hands. Do not place a heater or other appliance near the power cable. Do not allow water get into the electric parts. Do not store or use flammable gas near the product. Do not use the product in a confined space for a long period of time to avoid oxygen deficiency. If a flammable gas leaks, turn off the gas and open a window for ventilation before turning this
product on. Do not use the telephone or turn switches on or off. If strange sounds or smoke come from product, turn the breaker off or disconnect from power
www.mideaaircon.com 2
supply.
Stop operation and close window during a storm. If possible, remove product from window.
Do not open the product’s inlet grill while in operation. If the unit has an electrostatic filter, do not touch it.
Avoid having water enter the unit.
If the product becomes soaked, flooded, or submerged in water, contact an authorized service center.
Ventilate the product from time to time when operating it near a stove or other appliance.
Turn the main power off when cleaning or troubleshooting the product.
If the product will not be in use for a long period of time, disconnect it from the power supply or turn off the breaker. An unintended operation may occur.
Ensure that no one can step on or fall onto the outdoor unit.
CAUTION

To reduce the risk of injury or property damage after installing product, read and follow the warnings listed below.

Always check for gas (refrigerant) leakage after installing or repairing. Low refrigerant levels may cause product failure.
Install drain hose to ensure water drains away properly. A bad connection may cause water leakage.
Keep unit levelled when installing to avoid vibration or water leakage.
Do not install product where noise or hot air from the outdoor unit can bother others or damage property.
In order to avoid personal injury, use two or more people to lift and transport product.
Do not install the product where it will be directly exposed to ocean breeze (salt spray). It may cause corrosion, which, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
OPERATIONAL

To reduce the risk of fire or explosion, electric shock, personal injury, health issues, product failure, or property damage while the product is in operation, read and follow the warnings liste d below.

Do not sit in the draft or expose skin directly to cool air for long periods of time.
Do not use unit for other purposes, such as preserving foods, works of art, etc., not intended for this product. It is a consumer air conditioner, not a refrigerating system.
Do not block the inlet or outlet of airflow.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
Do not touch the metal parts of the product when removing the air filter. They are sharp.
Always insert the filter securely. Clean the filter every two weeks or, if necessary, more since a dirty filter reduces product efficiency and could cause product malfunction or damage.
Do not insert hands or other object through air inlet or outlet. There are sharp, moving parts inside.
www.mideaaircon.com 3

Dimensions

W x H x D (inches)
Dimension 1
No sleeve, rear grille, or rear net
Dimension 2
Includes sleeve with no rear grille and rear net
Dimension 3
Includes sleeve and rear net
Dimension 4
Includes sleeve, rear net, rear grille
Do not drink the water drained from the product. It is unsanitary.
Use a firm stool or ladder when cleaning the product.
Replace all batteries in the remote control with new ones. Do not mix old and new batteries.
Do not recharge or disassemble the batteries or dispose of them in a fire.
If the liquid from the batteries touches exposed skin and/or gets on clothing, wash with clean water. Do not use the remote if the batteries have leaked.
2.
Dimensions
42 x 15.9 x 20.9
42 x 16 x 22.8 42 x 16 x 23.1 42 x 16 x 23.9
www.mideaaircon.com 4
3.
Unit Components
Decomposition
Figure
www.mideaaircon.com 5
4.
Installation Details
4.1
How to Install Unit
www.mideaaircon.com 6

PREPARATION OF SLEEVE ASSEMBLY

Dimensions of air conditioner

(optional)
For an existing sleeve, measure the wall sleeve dimensions.
Install the new air conditioner according to these installation instructions to achieve the best performance. All wall sleeves used to mount the new air conditioner must be in good structural condition and have a rear grille that securely attaches to the sleeve or the overhang of the sleeve to secure the new air conditioner.
To avoid vibration and noise, make sure the unit is installed securely and firmly.
When installing the sleeve, make certain there is nothing within 20 inches of the back that would interfere with heat radiation and exhaust airflow. (See Fig. 2)
w
Fig. 2
Refer to the installation instruction of sleeve assembly for more details.

UNIT INSTALLATION

Carefully remove shipping tapes from the front panel. (See Fig. 3)
Remove the front panel (see Fig. 4) by pulling out the bottom to release the tabs (A). Then lift up (B).
Remove the shipping screw from the vent door. (See Fig. 5)
Rotate the vent control lever to either open or close the vent door. (See Fig. 6)
www.mideaaircon.com 7

UNIT INSTALLATION (CONTINUED)

4.2

Care and Cleaning

Keep unit levelled when lifting and sliding it into wall sleeve. Once it is firmly against front of wall sleeve, secure with 4 screws and washers (supplied in the Sleeve Assembly) through the unit overhang holes. (See Fig. 7 and Fig. 8)
Reinstall front panel. (See Fig. 9) Place tabs over top rail (A). Push inward at bottom until panel snaps into place (B).
If unit is installed where condensation drainage can drip in an undesirable location, an accessory drain kit should be installed and connected to drain system.

FRONT PANEL AND CASE

Turn unit off and disconnect from power supply. To clean, use water and a mild detergent. Do not use bleach or abrasive materials. Some commercial cleaners may damage the plastic parts.

OUTDOOR COIL

Coil on outdoor side of unit should be checked regularly. Unit will need to be removed to inspect dirt build-up that will occur on the inside of the coil. If clogged with dirt or soot, coil should be professionally cleaned. Clean inside and outside of outdoor coils regularly.
NOTE: Never use a high-pressure spray on coil.
www.mideaaircon.com 8
!
CAUTION
!
CAUTION
damage to unit.
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage or improper operation.
Airflow restriction may cause damage to the unit.
The most important thing do to in order to
maintain unit efficiency is to clean the filters once every two weeks as required.
Clogged filters reduce cooling, heating and
airflow.
Keeping filters clean will:
o Decrease cost of operation,
VENT DOOR FILTER
IMPORTANT: Turn unit off before cleaning
If the vent door is open, gaining access
requires removing the unit from the wall sleeve. Clean the vent filter twice a year or as required.
Make sure to remove the shipping screw from
the vent door. (See Fig.5)
Rotate the vent control lever to open the vent
door. (See Fig.6)
Remove the four screws from the vent door
filter. (See Fig.12)
Pull out the vent door steel wire from the hole
of the vent door, then take off the vent door and filter. (See Fig.12)
o Save energy, o Prevent clogged indoor coil, and o Reduce risk of premature component failure.
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage or improper operation.
Do not operate unit without filters in place. If a filter becomes torn or damaged, it should be replaced immediately.
Operating without filters or with damaged ones will allow dirt and dust to reach indoor coil and will reduce cooling, heating, airflow, and efficiency of unit. Airflow restriction may cause
Clean the filter. Dry thoroughly before
replacing.
Replace the vent door, reinstall the four
screws.
Reinsert the vent door steel wire.
To clean air filters:
o Vacuum off heavy soil, o Run water through filter, and o Dry thoroughly before replacing.
www.mideaaircon.com 9
4.3

Other Installations

Optional Wired/Wireless Digital Wall Stat and EMS systems.

DIP SWITCH 24V WIRED CONTROL
Digital Wired/Wireless Wall Stat Terminal
Loading...
+ 25 hidden pages