Midea MSABAU-09HRDN1-QRC8GW, MOZ-12HFN1-QRD0GW, MSABDU-18HRDN1-QRC8GW, MSABEU-24HRDN1-QRC8GW, MOZ1-18HFN1-QRD0GW Service Manual

...
Aurora 3D Inverter Series
Service Manual 2014
ABSEU-A1-1410
CONTENTS
1. Precaution .................................................................................................................................................... 3
1.1 Safety Precaution .......................................................................................................................... 3
1.2 Warning ......................................................................................................................................... 3
2. Function ........................................................................................................................................................ 6
3. Dimension .................................................................................................................................................... 7
3.1 Indoor Unit ..................................................................................................................................... 7
3.2 Outdoor Unit ................................................................................................................................ 10
4. Refrigerant Cycle Diagram ........................................................................................................................ 11
5. Wiring Diagram .......................................................................................................................................... 12
5.1 Indoor Unit ................................................................................................................................... 12
5.2 Outdoor Unit ................................................................................................................................ 14
6 Installation Details ...................................................................................................................................... 17
6.1 Wrench torque sheet for installation ........................................................................................... 17
6.2 Connecting the cables ................................................................................................................ 17
6.3 Pipe length and the elevation ..................................................................................................... 18
6.4 Installation for the first time ......................................................................................................... 19
6.5 Adding the refrigerant after running the system for many years ................................................ 20
6.6 Re-installation while the indoor unit need to be repaired ........................................................... 21
6.7 Re-installation while the outdoor unit need to be repaired ......................................................... 22
7. Operation Characteristics ......................................................................................................................... 24
8. Electronic function .................................................................................................................................... 25
8.1 Abbreviation ................................................................................................................................ 25
8.2 Display function ........................................................................................................................... 25
8.3 Main Protection ........................................................................................................................... 26
8.4 Operation Modes and Functions ................................................................................................. 27
9. Troubleshooting ......................................................................................................................................... 32
9.1 Indoor Unit Error Display ............................................................................................................. 33
9.2 Trouble shooting.......................................................................................................................... 34
1. Precaution
1.1 Safety Precaution
To prevent injury to the user or other
people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring
instruction will cause harm or damage.
Before service the unit, be sure to
read this service manual at first.
1.2 Warning
Installation
Do not use a defective or underrated
circuit breaker. Use this appliance on a dedicated circuit.
There is risk of fire or electric shock.
For electrical work, contact the dealer,
seller, a qualified electrician, or an authorized service center.
Do not disassemble or repair the product, there is risk of fire or electric shock.
Always ground the product.
There is risk of fire or electric shock.
Install the panel and the cover of
control box securely.
There is risk of fire of electric shock.
Always install a dedicated circuit and
breaker.
Improper wiring or installation may cause fore or electric shock.
Use the correctly rated breaker of
fuse.
There is risk of fire or electric shock.
Do not modify or extend the power
cable.
There is risk of fire or electric shock.
Do not install, remove, or reinstall the
unit by yourself (customer).
There is risk of fire, electric shock, explosion, or injury.
Be caution when unpacking and
installing the product.
Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser and evaporator.
For installation, always contact the
dealer or an authorized service center.
Do not install the product on a
defective installation stand.
Be sure the installation area does not
deteriorate with age.
If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Do not let the air conditioner run for a
long time when the humidity is very high and a door or a window is left open.
Take care to ensure that power cable
could not be pulled out or damaged during operation.
There is risk of fire or electric shock.
Do not place anything on the power
cable.
There is risk of fire or electric shock.
Do not plug or unplug the power
supply plug during operation.
There is risk of fire or electric shock.
Do not touch (operation) the product
with wet hands.
Do not place a heater or other
appliance near the power cable.
There is risk of fire and electric shock.
Do not allow water to run into
electrical parts.
It may cause fire, failure of the product, or electric shock.
Do not store or use flammable gas or
combustible near the product.
There is risk of fire or failure of product.
Do not use the product in a tightly
closed space for a long time.
Oxygen deficiency could occur.
When flammable gas leaks, turn off
the gas and open a window for ventilation before turn the product on.
If strange sounds or smoke comes
from product, turn the breaker off or disconnect the power supply cable.
There is risk of electric shock or fire.
Stop operation and close the window
in storm or hurricane. If possible, remove the product from the window before the hurricane arrives.
There is risk of property damage, failure of product, or electric shock.
Do not open the inlet grill of the
product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
There is risk of physical injury, electric shock, or product failure.
When the product is soaked, contact
an authorized service center.
There is risk of fire or electric shock.
Be caution that water could not enter
the product.
There is risk of fire, electric shock, or product damage.
Ventilate the product from time to
time when operating it together with a stove etc.
There is risk of fire or electric shock.
Turn the main power off when
cleaning or maintaining the product.
There is risk of electric shock.
When the product is not be used for a
long time, disconnect the power supply plug or turn off the breaker.
There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody
could step on or fall onto the outdoor unit.
This could result in personal injury and product damage.
CAUTION
Always check for gas (refrigerant)
leakage after installation or repair of product.
Low refrigerant levels may cause failure of product.
Install the drain hose to ensure that
water is drained away properly.
A bad connection may cause water leakage.
Keep level even when installing the
product.
It can avoid vibration of water leakage.
Do not install the product where the
noise or hot air from the outdoor unit could damage the neighborhoods.
It may cause a problem for your neighbors.
Use two or more people to lift and
transport the product.
Do not install the product where it will
be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
Operational
Do not expose the skin directly to
cool air for long time. (Do not sit in the draft).
Do not use the product for special
purposes, such as preserving foods, works of art etc. It is a consumer air conditioner, not a precision refrigerant system.
There is risk of damage or loss of property.
Do not block the inlet or outlet of air
flow.
Use a soft cloth to clean. Do not use
harsh detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the
product when removing the air filter. They are very sharp.
Do not step on or put anything on the
product. (outdoor units)
Always insert the filter securely.
Clean the filter every two weeks or more often if necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Do not insert hands or other objects
through air inlet or outlet while the product is operated.
Do not drink the water drained from
the product.
Use a firm stool or ladder when
cleaning or maintaining the product.
Be careful and avoid personal injury.
Replace the all batteries in the remote
control with new ones of the same type. Do not mix old and new batteries or different types of batteries.
There is risk of fire or explosion.
Do not recharge or disassemble the
batteries. Do not dispose of batteries in a fire.
They may burn of explode.
If the liquid from the batteries gets
onto your skin or clothes, wash it well with clean water. Do not use the remote of the batteries have leaked.
2. Function
Model Names of Indoor/Outdoor Units
3D inverter
Capacity
Indoor units
Outdoor units
9k
MSABAU-09HRDN1-QRC8GW
MOZ-09HFN1-QRD0GW
12k
MSABBU-12HRDN1-QRC8GW
MOZ-12HFN1-QRD0GW
18k
MSABDU-18HRDN1-QRC8GW
MOZ1-18HFN1-QRD0GW
24k
MSABEU-24HRDN1-QRC8GW
MOF-24HFN1-QRD0GW
Cold catalyst filter
Silver Ico Filter(O)
Vitamin C Filter(O)
3M HAM Filter(O)
Bio Filter(O)
Golden Fin(O)
Ionizer(O)
Compressor Crankcase Heater(O)1W Standby(O)
Louver Position Memory Function
Refrigerant Leakage Detect
Self-diag. Function
Hydrophilic Aluminum Fin
Anti-rust Cabinet
Valve Protection Cover
PTC Heating Belt(O)
Filter
2 ways of drainage
O:optional
3. Dimension
3.1 Indoor Unit
Model
W D H
MSABAU-09HRDN1-QRC8GW
722
187
290
MSABBU-12HRDN1-QRC8GW
802
189
297
MSABDU-18HRDN1-QRC8GW
965
215
319
MSABEU-24HRDN1-QRC8GW
1080
226
335
For MSABAU-09HRDN1-QRC8GW:
For MSABBU-12HRDN1-QRC8GW:
For MSABDU-18HRDN1-QRC8GW:
For MSABEU-24HRDN1-QRC8GW:
3.2 Outdoor Unit
More than 30cm
More than 60cm
More than 200cm
More than 30cm
More than 60cm (Service space)
Fence or
obstacles
Model
W D H
W1 A B
MOZ-09HFN1-QRD0GW
810
310
558
874
549
325
MOZ-12HFN1-QRD0GW
810
310
558
874
549
325
MOZ1-18HFN1-QRDOGW
810
310
558
874
549
325
MOF-22HFN1-QRD0GW
845
320
700
908
560
335
4. Refrigerant Cycle Diagram
LIQUID SIDE
GAS SIDE
HEAT EXCHANGE (EVAPORATOR)
HEAT EXCHANGE (CONDENSER)
COMPRESSOR
2-WAY VALVE
3-WAY VALVE
4-WAY VALVE
COOLING HEATING
T2 Evaporator temp. sensor
T1 Room temp. sensor
ACCUMULATOR
INDOOR OUTDOOR
CHECK VALVE (Heating Model only)
CAPILIARY TUBE
5. Wiring Diagram
5.1 Indoor Unit
MSABAU-09HRDN1-QRC8GW,MSABBU-12HRDN1-QRC8GW, MSABDU-18HRDN1-QRC8GW:
MSABEU-24HRDN1-QRC8GW
5.2 Outdoor Unit
MOZ-09HFN1-QRD0GW, MOZ-12HFN1-QRD0GW:
Loading...
+ 32 hidden pages