Cleaning the air filter and air freshening filter 9
Preparation for extended non-operation 9
Pre-season inspection 9
TROUBLESHOOTING TIPS
Troubleshooting tips 10
Troubleshooting guide 11
REMOTE CONTROLLER FUNCTIONS
Operation of Remote Control Buttons 12-14
Indicators on Remote LCD screen 15
Auto operation16
Cooling/Heating/Fan & Dehumidifier operation 16
Timer operation 17-19
Remote Controller Handling 20
3
CONGRATULATIONS ON THE PURCHASE OF
•
YOUR MIDEA MISSION SERIES INVERTER AIR
CONDITIONER;..THANK YOU.
SAFETY PRECAUTIONS
DISPOSAL: Do not dispose of this product as
unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic
household waste. For disposal, there are several
possibilities:
A) The municipality has established collection
systems, where electronic waste can be disposed of
by the user.
B) When buying a new product, the installer will
dispose of the old product.
C) As old products contain valuable resources, they
can be sold to scrap metal dealers.
Unrestricted disposal of waste into forests and natural
landscapes endangers peoples health when
hazardous substances leak into the ground-water and
find their way into the food chain.
It is suggested that this appliance can be used by
children aged from 8 years and above and persons
with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge if
they have been given supervision or instruction
concerning use of the appliance in a safe way and
understand the hazards involved. Children should
not play with the appliance. Cleaning and user
maintenance should not be done by children
without supervision.
To prevent injury to the user or other people and
also property damage, the following instructions
must be followed. Incorrect operation due to
ignoring of instructions may cause harm or
damage.
The seriousness is classified by the following
indications.
Do not expose your body directly
to the cool air for a prolonged
NAMESOFPARTS
period.
•Never poke fingers or other
objects in the air inlet and outlet
vents.
•Never attempt to repair, relocate,
and modify the air conditioner
yourself. Always contact your
service provider if required.
•Do not operate your air
conditioner in a wet room such as
a bathroom or laundry room.
•In the event of any abnormalities
such as a burning smell,
immediately switch off the device
and contact your service provider.
•Always switch off the device
before you start to clean it.
•Contact an authorized installer for
installation of this unit.
•Contact an authorized service
technician for repair or
maintenance of this unit.
4
NAMES OF PARTS
•
Never activate any switches with
wet hands as it may cause an
electric shock.
•Never use the device for any other
purpose than the intended use.
Never place objects on the unit.
•Do not expose plants or animals
directly to the air flow.
•Never use combustible cleaning
agents as these could cause a fire
or deformation of the unit.
•Never place any burning objects
close to the device if they could be
directly affected by the emitted
air. (Candles etc)
•Never step onto the outdoor unit
and never place anything on it.
•Never use an unsteady or rusty
base for the outdoor unit
mounting.
•Never install the air conditioner in
places where combustible gas can
be emitted as emitted gas may
collect and cause an explosion.
•Never allow the air conditioner to
run for too long with the doors or
windows open.
•If the air conditioner is to be used
in conjunction with other heating
appliances, the air in the room
should be refreshed periodically,
•Always switch the unit off at the
Mains switch if the unit is not
going to be used for any lengthy
period of time.
•Always switch off the air
conditioner during an electrical
storm otherwise, electrical parts
may get damaged.
•Check that the condensate
drainage line is correctly
connected. If not, water will
escape onto furnishings in the
room
•For electrical safety purposes it is
recommended that unit is
installed with an earth leakage
circuit-breaker.
NAME OF PARTS
INDOOR UNIT:
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grille
6. Vertical air flow louver (inside)
7. Display window
OUTDOOR UNIT:
8. Connecting pipe
9. Connecting cable
10. Stop valve
(Installertosupply)
(Installertosupply)
5
Displays when the WIFI control feature is activated.
(Not available when the unit does not have this
optional kit installed)
DISPLAY WINDOW
Digital display:
•Displays the temperature settings when the
air conditioner is operational.
• Displays the room temperature in FAN mode.
• Displays the self-diagnostic codes.
ON
•Displays
ON or when Swing, Turbo or Silence feature is
activated.
•Displays
OFF is set.
•Displays
Turbo or Silence feature is cancelled.
• Displays
• Displays
activated under heating mode.
•Displays
applicable).
•When ECO function is activated, the
the display window illuminates gradually one
by one as
→
E.... in one second intervals
for three seconds when Timer
OF
for three seconds when Timer
OF
for three seconds when Swing,
df
under defrosting operation.
cf
when anti-cold air feature is
SC
during self clean operation (if
88 in
E→ C → O→Set temperature
TEMPERATURE\MODE
Room Temperature
Outdoor Temperature
NOTE:
1. Optimum performance will be achieved within these operating temperatures however capacities
reduce as Outdoor ambient approaches the limits. If air conditioner is used outside of the above
conditions, certain safety protection features might come into operation and cause the unit to
function abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high (over 80%),
condensed water may drip from the unit. In this instance please set the vertical air flow louver to its
maximum angle (vertically to the floor) and set HIGH fan mode.
Cooling Operation
O
17
C ~32OC
O
0
C ~50OC
Heating Operation
0OC ~30OC
-15OC ~30OC
Drying Operation
10OC ~32OC
0OC ~50OC
6
Manual Operation (Continued)
1) Open and lift the front panel up to an angle
until it remains fixed with a clicking sound.
2) One press of the manual control switch will
lead to the forced AUTO operation. If pressed
twice within five seconds, the unit will operate
under forced COOL operation.
3) Close the panel firmly to its original position.
CAUTION:
This switch is normally used for testing purposes only.
Please do not use it unless necessary. To restore the
remote controller operation, use the remote controller
directly.
•Adjust the air flow direction properly, otherwise
it might cause discomfort or cause uneven
room temperatures.
•Adjust the horizontal louver using the remote
controller.
Adjusting vertical air flow (Up--Down)
Perform this function while the unit is in
operation. Use the remote controller to adjust
the vertical air flow direction by pressing the
Manual Operation
Units are equipped with a switch to run an emergency
operation mode. It can be accessed by opening the
front panel. This switch is used for manual operation in
case the remote controller fails to work or maintenance
is necessary.
NOTE:
The unit must be turned off before operating the
manual control button. If the unit is operational,
continue pressing the manual control button until the
unit is off.
Swing button The horizontal louver will
start non-stop up/down swing. The indoor unit
displays “on” for a second then reverts back to
Adjusting horizontal air flow (left - right)
IMPORTANT: Do not put your fingers into the air vents
as the high-speed fan inside may cause injury.
Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode otherwise condensation may
form on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings.
After a quick restart, the horizontal louver may remain
static for approximately 10 seconds. Open angle of the
horizontal louver should not be set too small, as
COOLING or HEATING performance may be reduced
due to too restricted air flow area. Do not move the
horizontal louver manually, otherwise the horizontal
louver will be out of sync. If this happens, please
cease operating, disconnect power for a few seconds
and then restart the air conditioner.
the Temperature display. If you press the
button again, horizontal louver stops at the
angle it as of that moment and unit displays
“of” for a second.
Again, press this button for 2 seconds
to start/stop vertical louver movement (Left to
right). Pressing again for 2 seconds will stop
left to right movement at angle when button
was pressed.
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.