Midea MGRH14A-PA3Z User Manual [ru]

Midea R410A 50Hz
Aqua Mini
Full DC Inverter Unitary Chiller
DM16-01.01.24en
Applicable Model:
MGRH5A-PA1Z MGRH7A-PA1Z
Midea reserves the right to discontinue, or change specification or designs at any time without notices and
without incurring obligations.
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
Content
1. Outdoor units lineup .......................................................... 2
Features .............................................................................. 4
2.
Description of main components .................................... 8
3.
Specifications .................................................................. 10
4.
Dimensions ...................................................................... 14
5.
Piping Diagram ................................................................ 15
6.
Wiring Diagram ............................................................... 16
7.
Electric Characteristics .................................................. 19
8.
Capacity Tables ............................................................. 20
9.
Operation Limits ............................................................ 26
10.
Water Pressure Drop .................................................... 28
11.
Sound Level ................................................................... 31
12.
Exploded View .............................................................. 32
13.
Installation .................................................................... 38
14.
Checking and Starting Up the Unit ............................. 51
15.
Running and Maintenance .......................................... 53
16.
Controller ....................................................................... 56
17.
Troubleshooting ............................................................. 69
18.
Optional Accessories ................................................... 94
19.
Manufacture reserves the right to discontinue, or change at any time, specifications or designs without notices
and with
out incurring obligations.
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
1. Outdoor units lineup
MGRH5A-PA1Z, MGRH7A-PA1Z
Model
MGRH5A-PA1Z
MGRH7A-PA1Z
Power Supply
(V/Ph/Hz)
220-240/1 /50 5.0kW DC Inverter Plate type Heat pump Built-in R410A
220-240/1/50 7.0kW DC Inverter Plate type Heat pump Built-in R410A
Capacity
Compressor
type
Heat
exchanger
A/C mode
Hydraulic module
Refrigerant
Model
MGRH10A-PA1Z
MGRH12A-PA3Z
MGRH14A-PA3Z
MGRH16A-PA3Z
2
MGRH10A-PA1Z,MGRH12A-PA3Z
MGRH14A-PA3Z, MGRH16A-PA3Z
Power Supply
(V/Ph/Hz)
220-240/1/50 10.0 DC Inverter Plate type Heat pump Built-in R410A 380-415/3/50 11.2 DC Inverter Plate type Heat pump Built-in R410A 380-415/3/50 12.5 DC Inverter Plate type Heat pump Built-in R410A 380-415/3/50 14.5 DC Inverter Plate type Heat pump Built-in R410A
Capacity
Compressor
type
Heat
exchanger
A/C mode
Hydraulic module
Refrigerant
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
2.Features
2.1 High efficient DC inverter compressor
Full DC inverter mini chiller adopts highly intelligent inverter-driven compressor enables the output of the out
door unit to be modulated by the real heat load demands..
. This advanced technology
This advanced system ensures precise temperature regulation and highly efficient energy usage, making a significant contribution to limiting the impact on the environment.
Highly Efficient DC Motor:
- Creative motor core design
- High density neodymium magnet
- Concentrated type stator
-Wider operating frequency range
Better balance and Extremely Low Vibration:
- Twin eccentric cams
- 2 balance weights
Highly Stable Moving Parts:
- Optimal material matching rollers and vanes
Compressor
(Twin Rotary) structure
-Optimize compressor drive technology
- Highly robust bearings
-Compact structure
2.2 High performance heat exchanger
The new designed window fins enlarge the heat-exchanging area, which decrease the air resistance, save more power and enhance heat exchan
ge performance.
Hydrophilic film fins and inner-threaded copper pipes optimize heat
New design Original design
High efficiency inner-thread pipe, enhance heat transfer.
exchange efficiency.
2.3 Low-operating sound design
Optimally design fan shape and new designed discharge air grille and air deflector, making higher air volume and reduces running noise..
Air deflector
New grille
New fan
4
2.4 High efficiency
1
2
EER
3.5
3
.5
2
.5
1
0.5
0
3.23
5kW 7kW 10kW 12kW 14kW 16kW
COP
3.5
3.24
3.11
3.2
3.39
3.5
3.31
3.31
3.21
3.25
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
3.20
3.30
3
2.5
2
1.5
1
0.5
0
5kW 7kW 10kW 12kW 14kW 1 6kW
2.5 Wideoperationtemperaturerange
Stable and safe running at wide ambient temperature range, cooling performance from -5 ˚C to 46˚C, heating from -15˚C to 27˚C.
COOLING MODE
-5°C
46°C
HEATING MODE
-15°C
-20
-10
0 10203040
27°C
50
°C(D.B.)
Outdoor temp.
2.6 Energy saving and high reliability
By adopting high efficiency plate heat exchanger, the energy consumption can be reduced.
5
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
a. Metallic protective cabinet with rustproof polyester paint; b. Built-in with voltage protection, current protection, anti-freezing protection, water flow protection and
etc., effectively guarantee the system to work safely.
2.7 User friendly remote control
Switch SW4_1(10kW) or SW3_1(12-16kW) on the PCB to ON to enable the following remote control
functions. The setting is not default at factory.
Remote shut down Remote cooling and heating
Note: When all controller controls together, the unit will work according to the last order.
5/7kW will be available soon.
2.8 Flexible and convenient control
Built-in electronic controller at factory.
Compact devices with advanced function and friendly user interface.
The chiller can be controlled by wired controller (KJR-120F/BMK-E)
also which is optional chosen.
Note: When connecting wired controller, outdoor unit control panel is mainly used for display which can check parameters and inquiry, and can’t be used to set mode and temperature.
Built-in water pressure gauge. Inspect the water pressure all the time.
2.9 Integrated and compact design
Fully integrated and built-in hydraulic module, such as expansion tank, plate type of heat exchanger,
water circulating pump, etc. It saves installation space and cost.
2.10 EXV control flow more precisely
Patented liquid distribution components to maximize performance and minimize defrost impact. Stable and accurate gas flow control. EXV achieves 500 pulses to adjust flow precisely. Ensure the temperature-control precisely and steadily to provide a comfortable environment.
6
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
Fast respond resulting in higher efficiency and improved reliability.
100%
95% 90% 85% 80% 75%
70% 65% 60% 55% 50% 45% 40% 35% 30% 25% 20% 15%
10%
2.11 Water pump starts/stops compulsory function
Press “Check” button for 3 seconds to start the water pump operating when the unit is standby. Press “Check” button for 3 seconds again to stop the water pump.
7
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
3. Description of main components
Structure
Panels and base are made from galvanized steel plate painted with epoxy power to ensure total resistance to atmospheric pollution, conde
Condenser coils:
The coils are made from high performance and seamless copper tuber and high surface area aluminum fins to ensure optimum heat exchange capability. Condenser coil protection grill is standard.
Fan motor:
To achieve high efficiency heat exchange, the unit is equipment with the high performance axial-flow fans. The fan is driven directly by weather proof motor to ensure reliable operation, the fan motor is six-pole electric motor with built-in thermal cut-out.
Evaporator:
The heat exchanger is made of AISI 316 stainless steel to ensure high heat exchange efficiency, complete with electric heater and differential pressure switch. The complete heat exchanger is insulated with thermal insulation closed cell rubber foam to give optimum thermal insulation.
Hydraulic module:
It is fully integrated and equipped with key hydraulic components such as expansion tank, plate type of heat-exchanger, water circulating pump.
The water pressure difference switch is provided in the units to protect against damage to the water pump.
Power and control electrical panel
Power and control electrical panel constructed in accordance with IEC 204-1/EN60335-2-40, complete with compressor contactor, control via control panel.
nsate collection pan as standard.
11 12
1
1 Electrical p
anel 2 Display panel 3 Plate heat exchanger 4 4-way valve 5 High pressure switch 6 Low pressure switch 7 Water Pump 8 Accumulator 9 Water flow switch 10 Compressor 11 Condenser 12 Expansion tank 13 Axial-flow fan
13
2 3
4 5
6 7
8
9 10
5/7KW
8
1
2
4
h
2
3 4
5 6
7
8 9
10
10~16KW
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
11
12 13
14 15
16 17
18
19
1 Operation panel
Water manometer
3 Automatic discharge valve
Axial-flow fan 5 Differential pressure switch 6 Condenser 7 Accumulater 8 Security discharge 9 Electric expansive valve 10 Plate heat exchanger
11 Electrical panel 12 High pressure switc 13 4-ways valve 14 Expansion tank 15 Pump 16 Low pressure switch 17 Storage tank 18 Compressor 19 Water supply valve
9
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
w
3
r
2
r
r
4. Specifications
Model Power supply V-Ph-Hz
Cooling*(1)
Cooling*(2)
Heating*(3)
Heating*(4) EER*(1) kW/kW 3.23 3.11
EER*(2) kW/kW 5.16 4.28 Max. input consumption kW 2.8 3.0 Max. input current A 14.6 15.6
Compressor
Outdoor fan motor
Outdoor coil
Water pump
Outdoor air flow m3/h 5100 5100 Throttle EXV+capillary EXV+capillary Outdoor noise level (sound pressure)*(3) dB(A) 58 58 Water flo The plate heat-exchanger water pressure
drop The Max. and Min. water inlet pressure kPa
Outdoor unit
Refrigerant Connection
wiring Pipe
diameter Control Wired controlle
Ambient temperature Cooling: -5℃~46℃; Heating: -15-27(Antifreeze must be added below 5℃) Water outlet temperature range Cooling: 4~20 ℃; Heating: 30~55
Capacity kW 5.0 7.0 Input kW 1.55 2.25 Capacity kW 6.57 7.88 Input kW 1.27 1.84 Capacity kW 5.5 8.0 Input kW 1.7 2.5 Capacity kW 6.32 8.29 Input kW 1.52 2.13
Model SNB172FJGMC SNB172FJGMC Type ROTARY ROTARY Brand Mitsubishi Electric Mitsubishi Electric Capacity kW 5.46 5.46 Input kW 1.64 1.64 Rated load current A 8.1 8.1 Locked rotor Amp A 29.5 29.5 Thermal protector Refrigerant oil ml FV50S,400 FV50S,400 Model Type Brand Input Speed Number of rows 22 Tube pitch(a)× row pitch(b) mm Fin spacing mm 1.6 1.6 Fin type Hydrophilic aluminum foil Hydrophilic aluminum foil
Tube outside dia. and type mm Coil length ×height mm 885×880 885×880
Number of circuits 66 Type RS15/6-3-WILO RS15/6-3-WILO Input (H/M/L) W 93/67/46 93/67/46 Pumping head m 5.5 5.5
Net dimension (W×H×D) mm 990×966×354 990×966×354 Packing dimension
(W×H×D) Net/ Gross weight kg 81/91 81/91 Type R410A R410A Charged volume kg 2.5 2.5 Power wi Signal wire mm2
Water inlet/outlet inch 1’’ 1’’
e mm
W 170 170
r/min 820 820
m
/h 0.86 1.20
kPa 15 15
mm 1120×1100×435 1120×1100×435
MGRH5A-PA1Z MGRH7A-PA1Z
220-240, 1, 50 220-240, 1, 50
Inner Inner
WZDK170-38G-1 WZDK170-38G-1
DC Motor DC Motor
NIDEC SHIBAURA NIDEC SHIBAURA
22×19.05 22×19.05
φ7.94 φ7.94
Inner grooved copper tube Inner grooved copper tube
500/150 500/150
3×2.5 3×2.5
3×0.75 3×0.75
Wired controlle
Note: Specifications are bas
ed on the following conditions:
1. Cooling: (*1) chilled water inlet/outlet temperature: 12/7°C,outdoor ambient temperature 35°C DB. (*2) chilled water inlet/outlet temperature: 23/18°C,outdoor ambient temperature 35°C DB.
10
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
w
3
Packi
d
i
(
r
2
r
r
2. Heating: (*3) warm water inlet/outlet temperature: 40/45°C,outdoor ambient temperature 7°C DB/6°C WB .
(*4) warm water inlet/outlet temperature: 30/35°C,outdoor ambient temperature 7°C DB/6°C WB .
3. It is tested 1m away in front of the unit in a semi-anechoic room(sound pressure).
4. The above data may be changed without notice for future improvement on quality and performance.
Model Power supply V-Ph-Hz
Cooling*(1)
Cooling*(2)
Heating*(3)
Heating*(4)
Capacity kW 10.0(2.9~10.5) 11.2(3.1~12.0) Input kW 2.95 3.38 Capacity kW 10.9 14.50 Input kW 2.49 2.80 Capacity kW 11.0(3.2~12.0) 12.3(3.3~13.2) Input kW 3.14 3.72 Capacity kW 10.96 13.75 Input kW 2.51 2.85
MGRH10A-PA1Z MGRH12A-PA3Z
220-240, 1, 50 380-415, 3, 50
EER(*1) kW/kW 3.39 3.31 EER(*2) kW/kW 4.39 5.17 Max. input consumption kW 4.8 5.2 Max. input current A 25 8.9
Model ATQ420D1UMU ATQ420D2UMU Type Rotary Rotary Brand GMCC GMCC Capacity kW 13.1 13.0
Compressor
Input kW 3.42 3.45 Rated load current A 6.85 6.9 Locked rotor Amp A 52 44 Thermal protector
Inner Inner
Refrigerant oil ml VG74,1400 VG74,1400
Outdoor fan motor
Model Type Brand Input Speed
W 100 100
r/min 800 800
WZDK100-38G WZDK100-38G
DC Motor DC Motor
Panasonic Panasonic
Number of rows 22 Tube pitch(a)× row pitch(b) mm
22×19.05 22×19.05
Fin spacing mm 1.6 1.6
Outdoor coil
Fin type Hydrophilic aluminum foil Tube outside dia. and type mm
φ7.94 φ7.94
Inner grooved copper tube
Coil length ×height mm 1276×870 1276×870 Number of circuits 77 Type RL25/8.5 RL25/8.5
Water pump
Input (H/M/L) W 210/175/120 210/175/120
Pumping head m 8 8 Outdoor air flow m3/h 7000 7000 Throttle EXV EXV Outdoor noise level (sound pressure)*(3) dB(A) 59 59 Water flo The plate heat-exchanger water pressure
drop The Max. and Min. water inlet pressure kPa
m
/h 1.72 1.92
kPa 18 18
500/150 500/150
Net dimension (W×H×D) mm 970×1327×400 970×1327×400 Outdoor
unit
ng
W×H×D)
mension
mm 1082×1456×435 1082×1456×435
Net/ Gross weight kg 110/121 110/121
Type R410A R410A Refrigerant
Connection wiring
Pipe diameter
Control Wired controlle
Charged volume kg 2.8 2.8
Power wi
e mm
Signal wire mm2
3×4.0 5×3.0
3×0.75 3×0.75
Water inlet/outlet inch 1-1/4” 1-1/4”
Wired controlle
Ambient temperature Cooling: -5℃~46℃; Heating: -15-27(Antifreeze must be added below 5℃) Water outlet temperature range Cooling: 4~20 ℃; Heating: 30~55
Note: Specifications are based on the follo
wing conditions:
11
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
w
3
Packi
d
i
(
r
2
r
r
1. Cooling: (*1) chilled water inlet/outlet temperature: 12/7°C,outdoor ambient temperature 35°C DB. (*2) chilled water inlet/outlet temperature: 23/18°C,outdoor ambient temperature 35°C DB.
2. Heating: (*3) warm water inlet/outlet temperature: 40/45°C,outdoor ambient temperature 7°C DB/6°C WB .
(*4) warm water inlet/outlet temperature: 30/35°C,outdoor ambient temperature 7°C DB/6°C WB .
3. It is tested 1m away in front of the unit in a semi-anechoic room(sound pressure).
4. The above data may be changed without notice for future improvement on quality and performance.
Model Power supply V-Ph-Hz
Cooling*(1)
Cooling*(2)
Heating*(3)
Heating*(4)
Capacity kW 12.5(3.3~14.0) 14.5(3.5~15.5) Input kW 3.9 4.53 Capacity kW 15.17 16.70 Input kW 3.13 3.73 Capacity kW 13.8(3.5~15.4) 16.0(3.7~17.0) Input kW 4.25 4.85 Capacity kW 15.30 16.97 Input kW 3.15 3.86
MGRH14A-PA3Z MGRH16A-PA3Z
380-415, 3, 50 380-415, 3, 50
EER(*1) kW/kW 3.2 3.2 EER(*2) kW/kW 4.84 4.48 Max. input consumption kW 5.6 5.9 Max. input current A 9.6 10.1
Model ATQ420D2UMU ATQ420D2UMU Type Rotary Rotary Brand GMCC GMCC Capacity kW 13.0 13.0
Compressor
Input kW 3.45 3.45 Rated load current A 6.9 6.9 Locked rotor Amp. A 44 44 Thermal protector
Inner Inner
Refrigerant oil ml VG74,1400 VG74,1400
Outdoor fan motor
Model Type Brand Input Speed
W 100 100
r/min 800 800
WZDK100-38G WZDK100-38G
DC Motor DC Motor
Panasonic Panasonic
Number of rows 22 Tube pitch(a)× row pitch(b) mm
22×19.05 22×19.05
Fin spacing mm 1.6 1.6
Outdoor coil
Fin type Hydrophilic aluminum foil Tube outside dia. and type mm
φ7.94 φ7.94
Inner grooved copper tube
Coil length ×height mm 1276×870 1276×870 Number of circuits 77 Type RL25/8.5 RL25/8.5
Water pump
Input (H/M/L) W 210/175/120 210/175/120
Pumping head m 8 8 Outdoor air flow m3/h 7000 7000 Throttle EXV EXV Outdoor noise level (sound pressure)*(3) dB(A) 60 60 Water flo The plate heat-exchanger water pressure
drop The Max. and Min. water inlet pressure kPa
m
/h 2.15 2.49
kPa 18 19
500/150 500/150
Net dimension (W×H×D) mm 970×1327×400 970×1327×400 Outdoor
unit
ng
W×H×D)
mension
mm 1082×1456×435 1082×1456×435
Net/ Gross weight kg 111/122 111/122 Refrigerant
Connection wiring
Pipe diameter
Control Wired controlle
Type R410A R410A
Charged volume kg 2.9 3.2
Power wi
e mm
Signal wire mm2
5×3.0 5×3.0
3×0.75 3×0.75
Water inlet/outlet inch 1-1/4’’ 1-1/4’’
Wired controlle
Ambient temperature Cooling: -5℃~46℃; Heating: -15-27(Antifreeze must be added below 5℃) Water outlet temperature range Cooling: 4~20 ℃; Heating: 30~55
12
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
Note: Specifications are based on the following conditions:
1. Cooling: (*1) chilled water inlet/outlet temperature: 12/7°C,outdoor ambient temperature 35°C DB. (*2) chilled water inlet/outlet temperature: 23/18°C,outdoor ambient temperature 35°C DB.
2.Heating: (*3) warm water inlet/outlet temperature: 40/45°C,outdoor ambient temperature 7°C DB/6°C WB .
(*4) warm water inlet/outlet temperature: 30/35°C,outdoor ambient temperature 7°C DB/6°C WB .
3. It is tested 1m away in front of the unit in a semi-anechoic room(sound pressure).
4. The above data may be changed without notice for future improvement on quality and performance.
13
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
5. Dimensions
MGRH5A-PA1Z, MGRH7A-PA1Z (Unit: mm)
354
966
990
366
624
MGRH10A-PA1Z, MGRH12A-PA3Z, MGRH14A-PA3Z, MGRH16A-PA3Z (Unit : mm)
1327
900
970
14
348
320
600
360
400
6. Piping Diagram
MGRH5A-PA1Z, MGRH7A-PA1Z
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
HEAT PUMP
1 compressor 2 high pressure switch 3 4-way v alue(only HEAP PUMP) 4 condenser 5 filter
6 electronic expansive valve 7 liquid receiver 8 plate heat exchanger 9 frost heater
10 water temperature sensor
MGRH10A-PA1Z,MGRH12A-PA3Z, MGRH14A-PA3Z, MGRH16A-PA3Z
20
19
17
15
9
18
7
13
10
8
16
2
HP
6
11 accumulator 12 low pressure switch 13 crankcase heater
22
23
21
24
A
5
7
11
LP
12
13
1 Compressor 2 4-Way Valve 3 Accumulatior 4 Air Side Heat Exchanger 5 Electronic Expansion Valve 6 Storage Tank 7 Strainer 8 Water Side Heat Exchanger
(Plate Heat Exchange)
9 Differential Pressure Switch 10 High Pressure Switch 11 Low Pressure Switch 12 Discharge Gas thermistor 13 thermistor For Outdoor Temperature 14 Thermistor For Evaporation In Heating
(Thermistor For Condenser In Cooling) 15 Thermistor For Plate Heat Exchange 1 16 Thermistor For Plate Heat Exchange 2
4
14
Cooling Heating
17 Thermistor For Water Outlet 18 Thermistor For Water Inlet 19 Automatic Discharge Valve 20 Expansion Tank 21 Circulating Pump 22 Pressure Gauge 23 Safety Valve 24 Auto-watet replenishing
15
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
7. Wiring Diagram
MGRH5A-PA1Z, MGRH7A-PA1Z
16
MGRH10A-PA1Z
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
17
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
MGRH12A-PA3Z,MGRH14A-PA3Z,
MGRH16A-PA3Z
18
8. Electric Characteristics
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
Model
MGRH5A-PA1Z MGRH7A-PA1Z
MGRH10A-PA1Z MGRH12A-PA3Z MGRH14A-PA3Z MGRH16A-PA3Z
Remark:
MCA: Min. Current Amps. (A) TOCA: Total Over-current Amps. (A) MFA: Max. Fuse Amps. (A) MSC: Max. Starting Amps. (A) RLA: Rated Current Amps. (A) OFM: Outdoor Fan Motor FLA: Full Load Amps. (A) kW: Rated Motor Output (kW)
Hz Voltage Phase Min. Max. MCA TOCA MFA MSC RLA kW FLA 50Hz 220~240V 1Ph 198V 264V 10.1 14.6 20 29.5 8.1 0.195 1.65 50Hz 220~240V 1Ph 198V 264V 10.1 15.6 20 29.5 8.1 0.195 1.65 50Hz 220~240V 1Ph 198V 264V 15.1 25.0 30 52 12.1 0.20 1.8 50Hz 380~415V 3Ph 342V 456V 8.6 8.9 15 44 6.9 0.20 1.8 50Hz 380~415V 3Ph 342V 456V 8.6 9.6 15 44 6.9 0.20 1.8 50Hz 380~415V 3Ph 342V 456V 8.6 10.1 15 44 6.9 0.20 1.8
Outdoor Unit Power Supply Compressor OFM
19
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
9. Capacity Tables
MGRH5A-PA1Z
Cooling
Chilled water outlet temp.
21.00 25.00 30.00 35.00 40.00 46.00
Capacity
Power
EER
Capacity
Ambient temp.(℃)
EER
Capacity
Power
EER
Power
Capacity
EER
Capacity
Power
EER
Power
Capacity
Power
EER
()
5.00 5.60 1.37 4.10 5.27 1.41 3.75 4.97 1.45 3.43 4.70 1.50 3.14 4.40 1.57 2.80 4.05 1.65 2.46
6.00 5.79 1.39 4.17 5.44 1.43 3.81 5.13 1.47 3.48 4.85 1.52 3.19 4.54 1.59 2.85 4.19 1.67 2.50
7.00 5.99 1.41 4.23 5.63 1.46 3.86 5.30 1.50 3.53 5.00 1.55 3.23 4.70 1.63 2.88 4.33 1.71 2.53
8.00 6.17 1.46 4.24 5.80 1.50 3.86 5.45 1.55 3.52 5.14 1.60 3.22 4.83 1.68 2.88 4.46 1.76 2.53
9.00 6.35 1.47 4.31 5.95 1.52 3.93 5.60 1.56 3.58 5.27 1.61 3.27 4.96 1.69 2.93 4.58 1.78 2.58
10.00 6.59 1.49 4.41 6.17 1.54 4.01 5.80 1.59 3.65 5.45 1.64 3.33 5.14 1.72 2.99 4.75 1.80 2.63
11.00 6.77 1.51 4.49 6.34 1.55 4.08 5.95 1.60 3.71 5.59 1.65 3.38 5.27 1.73 3.04 4.88 1.82 2.68
12.00 6.93 1.53 4.53 6.48 1.58 4.11 6.07 1.63 3.73 5.70 1.68 3.40 5.38 1.76 3.06 4.99 1.85 2.70
13.00 7.05 1.54 4.57 6.59 1.59 4.14 6.17 1.64 3.76 5.79 1.69 3.43 5.47 1.77 3.08 5.08 1.86 2.72
14.00 7.23 1.55 4.65 6.75 1.60 4.21 6.31 1.65 3.82 5.92 1.70 3.48 5.60 1.79 3.13 5.20 1.88 2.77
15.00 7.32 1.56 4.69 6.83 1.61 4.24 6.38 1.66 3.85 5.97 1.71 3.49 5.66 1.80 3.15 5.26 1.89 2.79
16.00 7.50 1.58 4.76 6.99 1.63 4.30 6.53 1.68 3.90 6.11 1.73 3.54 5.79 1.81 3.19 5.39 1.90 2.83
17.00 7.60 1.58 4.80 7.07 1.63 4.33 6.60 1.68 3.92 6.17 1.74 3.55 5.85 1.82 3.21 5.45 1.91 2.85
kW kW W/W kW kW
Note: The inlet/outlet w
ater temperature difference is 5°C.
W/
kW kW W/W kW kW W/W kW kW W/W kW kW W/W
W
Heating
Ambient temp.(℃)
Hot water outlet temp.
-10 -6 -2 2 7 10 13
Capacity
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
COP
Capacity
Power
COP
() kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W
40.00 3.41 1.06 3.21 4.26 1.21 3.53 5.02 1.34 3.74 5.58 1.46 3.82 6.06 1.54 3.94 6.79 1.63 4.17 7.81 1.76 4.44
41.00 3.30 1.09 3.04 4.13 1.23 3.35 4.87 1.37 3.55 5.42 1.49 3.64 5.89 1.57 3.76 6.59 1.66 3.97 7.57 1.80 4.21
42.00 3.21 1.11 2.90 4.02 1.26 3.19 4.74 1.40 3.39 5.28 1.52 3.47 5.75 1.60 3.59 6.42 1.70 3.78 7.36 1.83 4.02
43.00 3.13 1.13 2.77 3.93 1.28 3.06 4.64 1.43 3.25 5.17 1.55 3.33 5.64 1.63 3.45 6.28 1.73 3.63 7.19 1.87 3.84
44.00 3.07 1.15 2.66 3.86 1.31 2.94 4.56 1.46 3.13 5.09 1.58 3.21 5.56 1.67 3.33 6.18 1.77 3.50 7.05 1.91 3.70
45.00 3.03 1.18 2.57 3.81 1.34 2.85 4.50 1.49 3.03 5.03 1.62 3.12 5.50 1.70 3.24 6.11 1.80 3.39 6.96 1.95 3.58
46.00 2.97 1.19 2.50 3.74 1.35 2.77 4.43 1.50 2.95 4.95 1.63 3.04 5.42 1.72 3.16 6.00 1.82 3.30 6.83 1.97 3.48
47.00 2.88 1.21 2.37 3.63 1.38 2.64 4.31 1.53 2.81 4.82 1.66 2.90 5.28 1.75 3.02 5.84 1.86 3.15 6.64 2.00 3.31
48.00 2.77 1.25 2.21 3.49 1.42 2.46 4.15 1.58 2.63 4.65 1.71 2.71 5.10 1.80 2.83 5.63 1.91 2.94 6.38 2.07 3.09
49.00 2.61 1.30 2.01 3.31 1.48 2.24 3.93 1.64 2.40 4.41 1.78 2.48 4.84 1.88 2.58 5.34 1.99 2.68 6.04 2.15 2.81
50.00 2.45 1.36 1.79 3.10 1.55 2.00 3.69 1.72 2.14 4.14 1.87 2.21 4.55 1.97 2.31 5.01 2.09 2.40 5.66 2.26 2.51
Note: The inlet/outlet w
20
ater temperature difference is 5°C.
Chilled water outlet temp.
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
MGRH7A-PA1Z Cooling
Ambient temp.(℃)
21.00 25.00 30.00 35.00 40.00 46.00
Capacity
Power
EER
Capacity
EER
Capacity
Power
EER
Power
Capacity
EER
Capacity
Power
EER
Power
Capacity
Power
EER
()
5.00 7.84 1.98 3.95 7.38 2.04 3.61 6.96 2.11 3.31 6.58 2.17 3.03 6.17 2.28 2.70 5.67 2.39 2.37
6.00 8.10 2.01 4.03 7.62 2.07 3.67 7.18 2.14 3.36 6.78 2.21 3.08 6.36 2.32 2.75 5.86 2.43 2.41
7.00 8.38 2.05 4.08 7.88 2.12 3.72 7.42 2.18 3.40 7.00 2.25 3.11 6.57 2.36 2.78 6.06 2.48 2.44
8.00 8.64 2.12 4.09 8.12 2.18 3.72 7.63 2.25 3.40 7.20 2.32 3.11 6.76 2.43 2.78 6.24 2.56 2.44
9.00 8.89 2.14 4.16 8.34 2.20 3.79 7.84 2.27 3.45 7.38 2.34 3.15 6.94 2.46 2.83 6.42 2.58 2.49
10.00 9.22 2.17 4.26 8.64 2.23 3.87 8.12 2.30 3.52 7.64 2.38 3.22 7.19 2.49 2.88 6.65 2.62 2.54
11.00 9.48 2.19 4.33 8.88 2.26 3.93 8.33 2.33 3.58 7.83 2.40 3.26 7.38 2.52 2.93 6.83 2.64 2.58
12.00 9.70 2.22 4.37 9.07 2.29 3.96 8.50 2.36 3.60 7.98 2.43 3.28 7.54 2.56 2.95 6.99 2.68 2.60
13.00 9.87 2.24 4.41 9.23 2.31 4.00 8.64 2.38 3.63 8.10 2.45 3.30 7.66 2.58 2.97 7.11 2.70 2.63
14.00 10.12 2.25 4.49 9.45 2.32 4.06 8.84 2.40 3.69 8.28 2.47 3.35 7.83 2.59 3.02 7.28 2.72 2.67
15.00 10.25 2.27 4.52 9.56 2.34 4.09 8.93 2.41 3.71 8.36 2.48 3.37 7.92 2.61 3.04 7.37 2.74 2.69
16.00 10.50 2.29 4.59 9.79 2.36 4.15 9.14 2.43 3.76 8.55 2.51 3.41 8.10 2.63 3.08 7.54 2.76 2.73
17.00 10.64 2.30 4.63 9.90 2.37 4.18 9.24 2.44 3.78 8.63 2.52 3.43 8.19 2.65 3.10 7.64 2.78 2.75
kW kW W/W kW kW
W/
kW kW W/W kW kW W/W kW kW W/W kW kW W/W
W
Note: The inlet/outlet water temperature difference is 5°C.
Heating
Ambient temp.(℃)
Hot water outlet temp.
() kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W
40.00 4.96 1.56 3.17 6.20 1.78 3.49 7.30 1.98 3.70 8.11 2.15 3.78 8.81 2.26 3.90 9.87 2.40 4.12 11.35 2.59 4.39
41.00 4.81 1.60 3.01 6.01 1.81 3.32 7.08 2.02 3.51 7.88 2.19 3.60 8.57 2.31 3.72 9.59 2.44 3.92 11.00 2.64 4.17
42.00 4.67 1.63 2.87 5.85 1.85 3.16 6.90 2.06 3.35 7.68 2.24 3.44 8.37 2.35 3.56 9.34 2.49 3.74 10.70 2.69 3.97
43.00 4.55 1.66 2.74 5.71 1.89 3.03 6.75 2.10 3.21 7.52 2.28 3.30 8.20 2.40 3.42 9.14 2.55 3.59 10.45 2.75 3.80
44.00 4.47 1.70 2.63 5.61 1.93 2.91 6.63 2.14 3.10 7.40 2.33 3.18 8.08 2.45 3.30 8.98 2.60 3.46 10.26 2.80 3.66
45.00 4.40 1.73 2.54 5.54 1.97 2.82 6.55 2.19 3.00 7.32 2.38 3.08 8.00 2.50 3.20 8.88 2.65 3.35 10.12 2.86 3.54
46.00 4.31 1.75 2.47 5.43 1.99 2.74 6.44 2.21 2.92 7.20 2.40 3.00 7.88 2.53 3.12 8.73 2.68 3.26 9.94 2.89 3.44
47.00 4.19 1.78 2.35 5.28 2.03 2.61 6.26 2.25 2.78 7.01 2.45 2.87 7.68 2.58 2.98 8.50 2.73 3.11 9.65 2.95 3.27
48.00 4.02 1.84 2.19 5.08 2.09 2.43 6.03 2.32 2.60 6.76 2.52 2.68 7.41 2.65 2.79 8.19 2.81 2.91 9.28 3.04 3.06
49.00 3.80 1.91 1.99 4.81 2.17 2.22 5.72 2.41 2.37 6.42 2.62 2.45 7.04 2.76 2.55 7.76 2.92 2.65 8.79 3.16 2.78
50.00 3.56 2.01 1.77 4.50 2.28 1.98 5.36 2.53 2.12 6.02 2.75 2.19 6.62 2.90 2.29 7.28 3.07 2.37 8.23 3.32 2.48
-10 -6 -2 2 7 10 13
Capacity
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
COP
Capacity
Power
COP
Note: The inlet/outlet water temperature difference is 5°C.
21
Chilled water outlet temp.
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
MGRH10A-PA1Z Cooling
Ambient temp.(℃)
21.00 25.00 30.00 35.00 40.00 46.00
Capacity
Power
EER
Capacity
EER
Capacity
Power
EER
Power
Capacity
EER
Capacity
Power
EER
Power
Capacity
Power
EER
()
5.00 11.20 2.60 4.31 10.54 2.68 3.94 9.95 2.76 3.60 9.40 2.85 3.30 8.81 2.99 2.95 8.10 3.14 2.58
6.00 11.57 2.64 4.39 10.89 2.72 4.00 10.26 2.80 3.66 9.69 2.89 3.35 9.09 3.04 2.99 8.37 3.19 2.63
7.00 11.98 2.69 4.45 11.26 2.78 4.06 10.60 2.86 3.70 10.00 2.95 3.39 9.39 3.10 3.03 8.66 3.25 2.66
8.00 12.35 2.77 4.45 11.59 2.86 4.06 10.91 2.95 3.70 10.28 3.04 3.38 9.66 3.19 3.03 8.92 3.35 2.66
9.00 12.70 2.80 4.53 11.91 2.89 4.13 11.19 2.98 3.76 10.54 3.07 3.44 9.92 3.22 3.08 9.16 3.38 2.71
10.00 13.18 2.84 4.64 12.35 2.93 4.22 11.60 3.02 3.84 10.91 3.11 3.50 10.28 3.27 3.14 9.51 3.43 2.77
11.00 13.54 2.87 4.72 12.68 2.96 4.29 11.90 3.05 3.90 11.18 3.14 3.56 10.54 3.30 3.19 9.76 3.47 2.82
12.00 13.85 2.91 4.76 12.96 3.00 4.32 12.15 3.09 3.92 11.41 3.19 3.57 10.77 3.35 3.21 9.98 3.52 2.84
13.00 14.10 2.94 4.80 13.18 3.03 4.36 12.34 3.12 3.96 11.58 3.22 3.60 10.94 3.38 3.24 10.15 3.55 2.86
14.00 14.45 2.96 4.89 13.49 3.05 4.43 12.62 3.14 4.02 11.83 3.24 3.65 11.19 3.40 3.29 10.40 3.57 2.91
15.00 14.64 2.97 4.93 13.66 3.06 4.46 12.76 3.16 4.04 11.95 3.25 3.67 11.32 3.42 3.31 10.52 3.59 2.93
16.00 15.00 3.00 5.00 13.98 3.09 4.52 13.05 3.19 4.09 12.21 3.29 3.72 11.58 3.45 3.35 10.78 3.62 2.97
17.00 15.19 3.01 5.04 14.15 3.11 4.55 13.20 3.20 4.12 12.33 3.30 3.73 11.71 3.47 3.37 10.91 3.64 3.00
kW kW W/W kW kW
W/
kW kW W/W kW kW W/W kW kW W/W kW kW W/W
W
Note: The inlet/outlet water temperature difference is 5°C.
Heating
Ambient temp.(℃)
Hot water outlet temp.
()
40.00 6.82 1.96 3.47 8.53 2.23 3.82 10.04 2.48 4.05 11.15 2.70 4.14 12.12 2.84 4.27 13.57 3.01 4.51 15.61 3.25 4.80
41.00 6.61 2.00 3.30 8.27 2.28 3.63 9.74 2.53 3.85 10.83 2.75 3.94 11.79 2.90 4.07 13.18 3.07 4.29 15.13 3.32 4.56
42.00 6.42 2.05 3.14 8.04 2.32 3.46 9.48 2.58 3.67 10.56 2.81 3.76 11.50 2.96 3.89 12.84 3.13 4.10 14.71 3.38 4.35
43.00 6.26 2.09 3.00 7.86 2.37 3.31 9.28 2.64 3.52 10.34 2.86 3.61 11.28 3.02 3.74 12.56 3.20 3.93 14.37 3.45 4.16
44.00 6.14 2.13 2.88 7.71 2.42 3.19 9.12 2.69 3.39 10.18 2.92 3.48 11.11 3.08 3.61 12.35 3.26 3.79 14.11 3.52 4.00
45.00 6.05 2.17 2.78 7.61 2.47 3.08 9.01 2.74 3.28 10.07 2.98 3.37 11.00 3.14 3.50 12.21 3.33 3.67 13.92 3.59 3.87
46.00 5.93 2.20 2.70 7.47 2.49 3.00 8.85 2.77 3.19 9.90 3.01 3.29 10.84 3.17 3.42 12.01 3.36 3.57 13.66 3.63 3.76
47.00 5.76 2.24 2.57 7.26 2.54 2.85 8.61 2.83 3.05 9.65 3.07 3.14 10.56 3.23 3.27 11.68 3.43 3.41 13.27 3.70 3.58
48.00 5.53 2.31 2.40 6.98 2.62 2.66 8.29 2.91 2.85 9.30 3.17 2.94 10.19 3.33 3.06 11.25 3.53 3.19 12.76 3.81 3.35
49.00 5.23 2.40 2.18 6.61 2.73 2.43 7.86 3.03 2.60 8.82 3.29 2.68 9.68 3.47 2.79 10.67 3.67 2.91 12.08 3.97 3.05
50.00 4.89 2.52 1.94 6.19 2.86 2.16 7.37 3.18 2.32 8.28 3.46 2.40 9.10 3.64 2.50 10.01 3.86 2.60 11.32 4.17 2.72
-10 -6 -2 2 7 10 13
Capacity
Power
kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
COP
Note: The inlet/outlet water temperature difference is 5°C.
22
Chilled water outlet temp.
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
MGRH12A-PA3Z Cooling
Ambient temp.(℃)
21.00 25.00 30.00 35.00 40.00 46.00
Capacity
Power
EER
Capacity
EER
Capacity
Power
EER
Power
Capacity
EER
Capacity
Power
EER
Power
Capacity
Power
EER
()
5.00 12.54 2.98 4.21 11.81 3.07 3.85 11.14 3.16 3.52 10.53 3.26 3.23 9.86 3.42 2.88 9.08 3.60 2.52
6.00 12.96 3.02 4.29 12.19 3.12 3.91 11.49 3.21 3.58 10.85 3.31 3.28 10.18 3.48 2.93 9.38 3.65 2.57
7.00 13.41 3.08 4.35 12.61 3.18 3.96 11.87 3.28 3.62 11.20 3.38 3.31 10.52 3.55 2.96 9.70 3.73 2.60
8.00 13.83 3.18 4.35 12.99 3.28 3.96 12.22 3.38 3.62 11.51 3.48 3.31 10.82 3.66 2.96 9.99 3.84 2.60
9.00 14.22 3.21 4.43 13.34 3.31 4.03 12.54 3.41 3.68 11.80 3.52 3.36 11.11 3.69 3.01 10.26 3.88 2.65
10.00 14.76 3.26 4.53 13.83 3.36 4.12 12.99 3.46 3.75 12.22 3.57 3.42 11.51 3.75 3.07 10.65 3.93 2.71
11.00 15.17 3.29 4.61 14.20 3.39 4.19 13.32 3.49 3.81 12.52 3.60 3.48 11.81 3.78 3.12 10.94 3.97 2.75
12.00 15.52 3.34 4.65 14.52 3.44 4.22 13.60 3.55 3.84 12.77 3.66 3.49 12.06 3.84 3.14 11.18 4.03 2.77
13.00 15.79 3.36 4.70 14.76 3.47 4.26 13.82 3.57 3.87 12.97 3.69 3.52 12.25 3.87 3.17 11.37 4.06 2.80
14.00 16.19 3.39 4.78 15.11 3.49 4.33 14.14 3.60 3.93 13.25 3.71 3.57 12.54 3.90 3.22 11.65 4.09 2.85
15.00 16.39 3.40 4.82 15.29 3.51 4.36 14.29 3.62 3.95 13.38 3.73 3.59 12.67 3.92 3.24 11.79 4.11 2.87
16.00 16.80 3.44 4.89 15.66 3.54 4.42 14.62 3.65 4.00 13.68 3.77 3.63 12.97 3.95 3.28 12.07 4.15 2.91
17.00 17.02 3.45 4.93 15.85 3.56 4.45 14.78 3.67 4.03 13.81 3.78 3.65 13.11 3.97 3.30 12.22 4.17 2.93
kW kW W/W kW kW
W/
kW kW W/W kW kW W/W kW kW W/W kW kW W/W
W
Note: The inlet/outlet water temperature difference is 5°C.
Heating
Ambient temp.(℃)
Hot water outlet temp.
-10 -6 -2 2 7 10 13
Capacity
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
COP
Capacity
Power
COP
() kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W
40.00 7.63 2.33 3.28 9.54 2.65 3.61 11.22 2.94 3.82 12.47 3.19 3.90 13.55 3.36 4.03 15.18 3.56 4.26 17.46 3.85 4.53
41.00 7.39 2.38 3.11 9.25 2.70 3.43 10.89 3.00 3.63 12.12 3.26 3.72 13.18 3.43 3.84 14.74 3.64 4.05 16.92 3.93 4.31
42.00 7.17 2.42 2.96 8.99 2.75 3.26 10.60 3.06 3.46 11.81 3.33 3.55 12.86 3.50 3.67 14.35 3.71 3.87 16.45 4.01 4.10
43.00 7.00 2.47 2.83 8.78 2.81 3.13 10.37 3.12 3.32 11.56 3.39 3.41 12.61 3.57 3.53 14.05 3.79 3.71 16.07 4.09 3.93
44.00 6.87 2.52 2.72 8.63 2.87 3.01 10.20 3.19 3.20 11.38 3.46 3.29 12.42 3.65 3.41 13.81 3.86 3.57 15.78 4.17 3.78
45.00 6.77 2.58 2.63 8.51 2.93 2.91 10.07 3.25 3.10 11.25 3.53 3.18 12.30 3.72 3.31 13.65 3.94 3.46 15.56 4.26 3.65
46.00 6.63 2.60 2.55 8.36 2.96 2.83 9.90 3.28 3.01 11.07 3.57 3.10 12.12 3.76 3.22 13.42 3.98 3.37 15.28 4.30 3.55
47.00 6.44 2.65 2.43 8.12 3.01 2.69 9.63 3.35 2.88 10.78 3.64 2.96 11.81 3.83 3.08 13.06 4.06 3.22 14.84 4.39 3.38
48.00 6.18 2.73 2.26 7.81 3.10 2.51 9.27 3.45 2.69 10.40 3.75 2.77 11.40 3.95 2.89 12.58 4.18 3.01 14.27 4.52 3.16
49.00 5.85 2.84 2.06 7.39 3.23 2.29 8.79 3.59 2.45 9.87 3.90 2.53 10.83 4.11 2.64 11.93 4.35 2.74 13.51 4.70 2.87
50.00 5.47 2.98 1.83 6.93 3.39 2.04 8.24 3.77 2.19 9.26 4.09 2.26 10.18 4.31 2.36 11.20 4.57 2.45 12.65 4.93 2.56
Note: The inlet/outlet
water temperature difference is 5°C.
23
Chilled water outlet temp.
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
Cooling MGRH14A-PA3Z
Ambient temp.(℃)
21.00 25.00 30.00 35.00 40.00 46.00
Capacity
Power
EER
Capacity
EER
Capacity
Power
EER
Power
Capacity
EER
Capacity
Power
EER
Power
Capacity
Power
EER
()
5.00 13.99 3.43 4.07 13.18 3.54 3.72 12.43 3.65 3.41 11.75 3.76 3.12 11.01 3.95 2.79 10.13 4.15 2.44
6.00 14.47 3.49 4.15 13.61 3.60 3.78 12.83 3.71 3.46 12.11 3.82 3.17 11.36 4.01 2.83 10.46 4.21 2.48
7.00 14.97 3.56 4.21 14.07 3.67 3.83 13.25 3.78 3.50 12.50 3.90 3.21 11.74 4.10 2.87 10.82 4.30 2.52
8.00 15.43 3.67 4.21 14.49 3.78 3.83 13.63 3.90 3.50 12.85 4.02 3.20 12.08 4.22 2.86 11.15 4.43 2.52
9.00 15.87 3.70 4.29 14.89 3.82 3.90 13.99 3.93 3.56 13.18 4.06 3.25 12.40 4.26 2.91 11.46 4.47 2.56
10.00 16.47 3.76 4.38 15.44 3.87 3.99 14.50 3.99 3.63 13.64 4.12 3.31 12.85 4.32 2.97 11.88 4.54 2.62
11.00 16.93 3.79 4.46 15.85 3.91 4.05 14.87 4.03 3.69 13.98 4.16 3.36 13.18 4.37 3.02 12.20 4.58 2.66
12.00 17.32 3.85 4.50 16.20 3.97 4.08 15.18 4.09 3.71 14.26 4.22 3.38 13.46 4.43 3.04 12.48 4.65 2.68
13.00 17.63 3.88 4.54 16.47 4.00 4.12 15.43 4.12 3.74 14.47 4.25 3.40 13.67 4.46 3.06 12.69 4.69 2.71
14.00 18.07 3.91 4.62 16.87 4.03 4.19 15.78 4.15 3.80 14.79 4.28 3.45 13.99 4.50 3.11 13.00 4.72 2.75
15.00 18.30 3.93 4.66 17.07 4.05 4.22 15.95 4.17 3.82 14.94 4.30 3.47 14.15 4.52 3.13 13.15 4.74 2.77
16.00 18.75 3.97 4.73 17.48 4.09 4.27 16.32 4.22 3.87 15.27 4.35 3.51 14.47 4.56 3.17 13.47 4.79 2.81
17.00 18.99 3.99 4.77 17.68 4.11 4.30 16.50 4.24 3.89 15.42 4.37 3.53 14.63 4.59 3.19 13.64 4.81 2.83
kW kW W/W kW kW
W/
kW kW W/W kW kW W/W kW kW W/W kW kW W/W
W
Note: The inlet/outlet water temperature difference is 5°C.
Heating
Ambient temp.(℃)
Hot water outlet temp.
() kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W
40.00 8.56 2.66 3.22 10.70 3.02 3.54 12.59 3.36 3.75 13.99 3.65 3.83 15.20 3.84 3.96 17.03 4.07 4.18 19.58 4.40 4.45
41.00 8.29 2.71 3.05 10.37 3.08 3.36 12.22 3.43 3.57 13.59 3.72 3.65 14.79 3.92 3.77 16.54 4.16 3.98 18.98 4.49 4.23
42.00 8.05 2.77 2.91 10.09 3.15 3.21 11.90 3.50 3.40 13.25 3.80 3.49 14.43 4.00 3.61 16.10 4.24 3.80 18.46 4.58 4.03
43.00 7.86 2.83 2.78 9.86 3.21 3.07 11.64 3.57 3.26 12.97 3.88 3.35 14.15 4.08 3.47 15.76 4.33 3.64 18.03 4.67 3.86
44.00 7.70 2.88 2.67 9.68 3.28 2.95 11.44 3.64 3.14 12.77 3.96 3.23 13.94 4.17 3.35 15.50 4.41 3.51 17.70 4.77 3.71
45.00 7.59 2.94 2.58 9.55 3.34 2.86 11.30 3.71 3.04 12.63 4.04 3.13 13.80 4.25 3.25 15.32 4.51 3.40 17.46 4.87 3.59
46.00 7.44 2.97 2.51 9.37 3.38 2.78 11.11 3.75 2.96 12.42 4.08 3.05 13.59 4.29 3.17 15.06 4.55 3.31 17.14 4.91 3.49
47.00 7.22 3.03 2.38 9.11 3.44 2.64 10.81 3.83 2.82 12.10 4.16 2.91 13.25 4.38 3.03 14.66 4.64 3.16 16.65 5.01 3.32
48.00 6.94 3.12 2.22 8.76 3.55 2.47 10.40 3.94 2.64 11.66 4.28 2.72 12.79 4.51 2.84 14.12 4.78 2.95 16.01 5.16 3.10
49.00 6.56 3.25 2.02 8.29 3.69 2.25 9.86 4.10 2.41 11.07 4.46 2.48 12.15 4.69 2.59 13.39 4.97 2.69 15.16 5.37 2.82
50.00 6.14 3.41 1.80 7.77 3.87 2.01 9.25 4.30 2.15 10.39 4.68 2.22 11.42 4.92 2.32 12.56 5.22 2.41 14.20 5.64 2.52
-10 -6 -2 2 7 10 13
Capacity
Power
Note: The inlet/outlet
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
COP
water temperature difference is 5°C.
Capacity
Power
COP
24
MGRH16A-PA3Z
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
Cooling
Chilled water outlet temp.
()
5.00 16.23 3.99 4.07 15.29 4.11 3.72 14.42 4.24 3.40 13.63 4.37 3.12 12.77 4.59 2.78 11.75 4.82 2.44
6.00 16.78 4.05 4.14 15.79 4.18 3.78 14.88 4.31 3.46 14.05 4.44 3.16 13.18 4.66 2.83 12.14 4.89 2.48
7.00 17.37 4.13 4.20 16.32 4.26 3.83 15.37 4.39 3.50 14.50 4.53 3.20 13.62 4.76 2.86 12.55 4.99 2.51
8.00 17.90 4.26 4.20 16.81 4.39 3.83 15.82 4.53 3.49 14.91 4.67 3.19 14.01 4.90 2.86 12.93 5.14 2.51
9.00 18.41 4.30 4.28 17.27 4.43 3.90 16.23 4.57 3.55 15.28 4.71 3.24 14.38 4.95 2.91 13.29 5.19 2.56
10.00 19.11 4.36 4.38 17.91 4.50 3.98 16.81 4.64 3.63 15.82 4.78 3.31 14.90 5.02 2.97 13.78 5.27 2.61
11.00 19.64 4.41 4.46 18.39 4.54 4.05 17.25 4.68 3.68 16.21 4.83 3.36 15.29 5.07 3.02 14.16 5.32 2.66
12.00 20.09 4.47 4.49 18.79 4.61 4.08 17.61 4.75 3.71 16.54 4.90 3.38 15.61 5.14 3.03 14.47 5.40 2.68
13.00 20.45 4.51 4.54 19.11 4.65 4.11 17.89 4.79 3.74 16.79 4.94 3.40 15.86 5.19 3.06 14.72 5.45 2.70
14.00 20.96 4.54 4.62 19.57 4.68 4.18 18.30 4.82 3.79 17.15 4.97 3.45 16.23 5.22 3.11 15.08 5.48 2.75
15.00 21.23 4.56 4.65 19.80 4.70 4.21 18.50 4.85 3.82 17.33 5.00 3.47 16.41 5.25 3.13 15.26 5.51 2.77
16.00 21.75 4.61 4.72 20.27 4.75 4.27 18.93 4.90 3.87 17.71 5.05 3.51 16.79 5.30 3.17 15.63 5.57 2.81
17.00 22.03 4.63 4.76 20.51 4.77 4.30 19.14 4.92 3.89 17.88 5.07 3.53 16.97 5.33 3.19 15.82 5.59 2.83
Capacity
kW kW W/W kW kW
Ambient temp.(℃)
21.00 25.00 30.00 35.00 40.00 46.00
EER
Capacity
Power
Power
Capacity
EER
W/
kW kW W/W kW kW W/W kW kW W/W kW kW W/W
W
Power
EER
Capacity
EER
Capacity
Power
EER
Power
Capacity
Power
EER
Note: The inlet/outlet water temperature difference is 5°C.
Heating
Ambient temp.(℃)
Hot water outlet temp.
()
40.00 9.93 3.03 3.27 12.41 3.45 3.60 14.60 3.83 3.81 16.22 4.16 3.89 17.63 4.38 4.02 19.74 4.65 4.25 22.71 5.02 4.52
41.00 9.61 3.10 3.10 12.03 3.52 3.42 14.17 3.91 3.62 15.76 4.25 3.71 17.15 4.47 3.83 19.17 4.74 4.04 22.01 5.12 4.30
42.00 9.33 3.16 2.95 11.70 3.59 3.26 13.79 3.99 3.46 15.36 4.34 3.54 16.73 4.56 3.67 18.67 4.84 3.86 21.40 5.23 4.09
43.00 9.11 3.22 2.82 11.43 3.66 3.12 13.49 4.07 3.31 15.04 4.43 3.40 16.40 4.66 3.52 18.27 4.94 3.70 20.90 5.33 3.92
44.00 8.93 3.29 2.71 11.22 3.74 3.00 13.26 4.15 3.19 14.80 4.52 3.28 16.16 4.75 3.40 17.97 5.04 3.57 20.52 5.44 3.77
45.00 8.80 3.36 2.62 11.07 3.82 2.90 13.10 4.24 3.09 14.64 4.61 3.18 16.00 4.85 3.30 17.76 5.14 3.45 20.25 5.55 3.65
46.00 8.63 3.39 2.55 10.87 3.85 2.82 12.88 4.28 3.01 14.40 4.65 3.10 15.76 4.90 3.22 17.46 5.19 3.36 19.87 5.61 3.54
47.00 8.37 3.46 2.42 10.56 3.93 2.69 12.53 4.37 2.87 14.03 4.75 2.96 15.37 5.00 3.08 16.99 5.30 3.21 19.31 5.72 3.38
48.00 8.04 3.56 2.26 10.16 4.05 2.51 12.06 4.50 2.68 13.52 4.89 2.77 14.83 5.15 2.88 16.37 5.46 3.00 18.56 5.89 3.15
49.00 7.61 3.70 2.05 9.62 4.21 2.28 11.43 4.68 2.44 12.83 5.08 2.52 14.09 5.35 2.63 15.52 5.67 2.74 17.57 6.13 2.87
50.00 7.12 3.89 1.83 9.01 4.42 2.04 10.72 4.91 2.18 12.05 5.34 2.26 13.24 5.62 2.36 14.57 5.96 2.45 16.46 6.43 2.56
-10 -6 -2 2 7 10 13
Capacity
Power
kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W kW kW W/W
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
Capacity
COP
Power
COP
Note: The inlet/outlet water temperature difference is 5°C.
25
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
T
A
TRIAEDISTUO
G
T
A
TRIAEDISTUO
10. Operation Limits
COOLING
C
46
ERU
35
REPME
20
-5
-
-10 4 5 7 15 20
DELIVERY WATER TEMPERATURE
HEATIN
C
27
ERU
20
REPME
7
-3
-15
30 45 55
35
DELIVERY WATER TEMPERATURE
a) Ethylene Glycol Solutions
C
C
Water and ethylene glycol
solutions used as a thermal vector in the place of water reduce the performance
of the unit. Multiply the performance figures by the values given in the following table.
Freezing point (°C)
0 -5 -10 -15 -20 -25
Percentage of ethylene glycol in weight
0 12% 20% 28% 35% 40%
cPf
cQ
cdp
cPf: correction factor of heating/cooling capacity cQ: correction factor of flow rate cdp: correction factor of pressure drop
26
1 0.98 0.97 0.965 0.96 0.955 1 1.02 1.04 1.075 1.11 1.14 1 1.07 1.11 1.18 1.22 1.24
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
Note:
1. During winter leaving the unit unused, please drain water out completely from unit if no anti-freeze were charged into pipeline, or keep power on (at standby or off status) and ensure that water is contained inside of unit.
2. When ambient temperature lower 5 ,℃ running cooling mode must be charged antifreeze. Refers to upper parameters for the charged volume.
b) Fouling Factors
The performance data given refer to conditions with clean evaporator plates (fouling factor=1). For different fouling factors, multiply the figures in the performance tables by the coefficient given in the following table.
Fouling factors Evaporator
(m 2 °C/W) f1 fk1 fx1
-5
4.4×10
0.86×10
1.72×10
f1 correction factor of capacity fk1 power input correction factor of compre ssor fx1 correction factor of total power input
-4
-4
- - -
0.96 0.99 0.99
0.93 0.98 0.98
27
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
11. Water Pressure Drop
MGRH5A-PA1Z, MGRH7A-PA1Z
MGRH10A-PA1Z
Heat exchanger pressure drop (water side) 研发提供
28
MGRH12A-PA3Z
Aqua Mini Full DC Inverter Unitary Chiller 50Hz
MGRH14A-PA3Z
29
Loading...
+ 67 hidden pages