Midea MCA-12HRN1, MCC-30HRN1, MCA-18HRN1, MCC-24HRN1, MCC-30HRN1-R User Manual

...
MCAC-UTSM-2008-11 Contents
Contents i
Part 1 General Information ..................................................................................................... 1
Part 2 Indoor Units .................................................................................................................. 7
Part 3 Outdoor Units ............................................................................................................. 88
Part 4 Installation ................................................................................................................ 127
Part 5 Control ...................................................................................................................... 136
The specifications, designs, and information in this book are subject to change without notice for product improvement.
MCAC-UTSM-2008-11 General Information
General Information 1
Part 1
General Information
1. Model Names of Indoor/Outdoor Units ...................... 2
2. External Appearance .................................................. 3
2.1 Indoor Units ................................................................................. 3
2.2 Outdoor Units............................................................................... 4
3. Nomenclature ............................................................. 5
4. Features ...................................................................... 6
Model Names of Indoor/Outdoor Units MCAC-UTSM-2008-11
2 General Information
1. Model Names of Indoor/Outdoor Units
Outdoor unit model Power supply (V-ph-Hz) Compressor type Compressor brand Matched indoor units model
MOU-12HN1 220~240-1-50 ROTARY MIDEA-TOSHIBA
MCA-12HRN1 MUB-12HRN1
MOUA-18HN1 220~240-1-50 ROTARY MIDEA-TOSHIBA
MCA-18HRN1 MUB-18HRN1
MOUA-24HN1 220~240-1-50 ROTARY MIDEA-TOSHIBA
MCC-24HRN1 MUB-24HRN1
MOU-30HN1 220~240-1-50 SCROLL SANYO
MCC-30HRN1 MUB-30HRN1
MOU-30HN1-R 380~415-3-50 SCROLL SANYO
MCC-30HRN1-R
MUB-30HRN1
MOU-36HN1 220~240-1-50 SCROLL SANYO
MCC-36HRN1 MUB-36HRN1
MOU-36HN1-R 380~415-3-50 SCROLL SANYO
MCC-36HRN1-R
MUB-36HRN1
MOUA-48HN1-R 380~415-3-50 SCROLL DAIKIN
MCC-48HRN1-R MUB-48HRN1-R
MOUA-60HN1-R 380~415-3-50 SCROLL SANYO MUB-60HRN1-R
MCAC-UTSM-2008-11 External Appearance
General Information 3
2. External Appearance
2.1 Indoor Units
Four-way cassette type (compact)
Four-way cassette type
Ceiling & floor type
Ceiling & floor type
External Appearance MCAC-UTSM-2008-11
4 General Information
2.2 Outdoor Units
12,000Btu/h
18,000Btu/h
24,000Btu/h
30,000~36,000Btu/h
48,000Btu/h
60,000Btu/h
MCAC-UTSM-2008-11 Nomenclature
General Information 5
3. Nomenclature
3.1 Indoor Unit
M C C - 48 H R N1 - R
Power Supply R 380~415V, 3N, 50Hz
-- 220~240V, 1N, 50Hz
Refrigerant Type N1 R410A
Control Mode
W Wired Control R Remote Control
Function Code C Cooling Only H Cooling & Heating
Capacity (×1000Btu/h)
Product Series
A Time A Designed B Time B Designed
C Time C Designed Indoor Unit Type
T Duct H High Static Pressure Duct C Cassette U Ceiling & Floor
Midea
3.2 Outdoor Unit
Power Supply R 380V~415V, 3N, 50Hz
-- 220~240V, 1N, 50Hz
Refrigerant Type N1 R410A
Function Code C Cooling Only H Cooling & Heating
Capacity (×1000Btu/h)
Product Series A Time A Designed B Time B Designed
Universal Outdoor Unit O Outdoor unit U Universal
Midea
M O U A - 48 H N1 - R
Features MCAC-UTSM-2008-11
6 General Information
4. Features
1. High quality coils: The coil is constructed of advanced inner grooved copper tube and aluminum fins.
2. Anti-rust, 500 hours salt spray test.
3. Low operation sound level: Well-known stable and quiet running fan motor.
4. Well-known compressor.
5. Compact design: Smaller dimension and larger stuffing capacity.
6. Universal outdoor unit design.
7. Optional air outlet grille: plastic type and wire type.
Metal grille Plastic type Plastic type
8. Optional low temperature cooling module.
9. R410A environment friendly refrigerant.
MCAC-UTSM-2008-11 Indoor Units
Indoor Units 7
Part 2
Indoor Units
Four-way Cassette Type (Compact) .............................. 8
Four-way Cassette Type............................................... 21
Ceiling & Floor Type ..................................................... 53
Four-way Cassette Type (Compact) MCAC-UTSM-2008-11
8 Indoor Units
Four-way Cassette Type (Compact)
1. Features ...................................................................................................... 9
2. Specifications .......................................................................................... 10
3. Dimensions .............................................................................................. 11
4. Service Space .......................................................................................... 11
5. Wiring Diagram ........................................................................................ 12
6. Air Velocity and Temperature Distributions .......................................... 13
7. Capacity Tables ........................................................................................ 14
8. Electric Characteristics ........................................................................... 16
9. Sound Levels ........................................................................................... 16
10. Exploded View ....................................................................................... 17
11. Accessories ............................................................................................ 18
12. The Specification of Power ................................................................... 18
13. Field Wiring ............................................................................................ 19
MCAC-UTSM-2008-11 Features
Indoor Units 9
1. Features
(1) Low operation noise
---Streamline plate ensures quietness
---Creates natural and comfortable environment
(2) Efficient cooling
---Equal, fast and widerange cooling
(3) The adoption of the most advanced 3-Dimensional Screw Fan
---Reduces the air resistance passing through
---Smoothes the air flow
---Makes air speed distribution to the heat exchange uniform
(4) Improvement for easy installation and maintenance
---Little space is required for installation into a shallow ceiling
---Because of the compactness and weight reduction of the main unit and panel, all models can be
installed without a hoist
Specifications MCAC-UTSM-2008-11
10 Indoor Units
2. Specifications
Model MCA-12HRN1 MCA-18HRN1 Code 220042002960 220042001870 Power supply V-ph-Hz
220~240-1-50 220~240-1-50
Cooling
Capacity kW 3.2 5.3 Input W 1100 1900
Heating
Capacity kW 4 6 Input W 1050 1900
Indoor fan motor
Model YDK45-4F YDK45-4F Brand Welling Welling Input W 56.7/51.5/44.4 56.7/51.5/44.4 Capacitor uF 1.5uF/450V 2.5uF/450V Speed(Hi/Mi/Lo) r/min 930/845/680 930/845/680
Indoor coil
Number of rows 2 2 Tube pitch(a)×row pitch(b) mm 21×13.37 21×13.37 Fin spacing mm 1.4 1.4 Fin type (code) Hydrophilic aluminium Hydrophilic aluminium Tube outside dia.and type mm φ7 Inner grooved copper tube φ7 Inner grooved copper tube
Coil length × height × width
mm 1215×210×26.74 1215×210×26.74
Number of circuits 5 5 Indoor air flow (Hi/Mi/Lo) m3/h 680/600/400 860/760/500 Indoor noise level (sound pressure) dB(A) 41/38/35 42.5/39.4/35.8
Indoor unit
Dimension (W×H×D)(body) mm 580×254×580 580×254×580
Packing (W×H×D)(body) mm 750×340×745 750×340×745
Dimension (W×H×D)(panel) mm 650×30×650 650×30×650
Packing (W×H×D)(panel) mm 715×115×715 715×115×715
Net/Gross weight(body) kg 21/28 21/27
Net/Gross weight(panel) kg 3/5 3/5 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/ Gas side mm φ6.4/φ12.7 φ6.4/φ12.7 Drainage water pipe diameter mm ODφ25 ODφ25
Connection wiring
Power wiring mm2 3×2.5 3×2.5
Strong electric signal wiring mm2 5×2.5 5×2.5
Weak electric signal wiring mm2 1-core shield wire 1×0.5 1-core shield wire 1×0.5 Controller R11HG/E(standard) R11HG/E(standard) Operation temperature 17-30 17-30
Notes: 1. Nominal cooling capacities are based on the following conditions:
Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB;
2. Nominal heating capacities are based on the following conditions: Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB;
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room.
MCAC-UTSM-2008-11 Dimensions
Indoor Units 11
3. Dimensions
4. Service Space
Wiring Diagram MCAC-UTSM-2008-11
12 Indoor Units
5. Wiring Diagram
MCAC-UTSM-2008-11 Air Velocity and Temperature Distributions
Indoor Units 13
6. Air Velocity and Temperature Distributions
Airflow velocity
Temperature
Capacity Tables MCAC-UTSM-2008-11
14 Indoor Units
7. Capacity Tables
7.1 Cooling Capacity MCA-12HRN1
Cooling Outdoor conditions (DB)
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC
21/15ºC DB/WB
TC 3.30 3.14 2.98 2.85 SC 2.44 2.41 2.38 2.39 Input 0.91 0.99 1.03 1.07
24/17ºC DB/WB
TC 3.39 3.23 3.07 2.88 SC 2.54 2.52 2.49 2.42 Input 0.97 1.03 1.08 1.13
27/19ºC DB/WB
TC 3.46 3.30 3.20 2.98 SC 2.56 2.54 2.50 2.44 Input 0.99 1.05 1.10 1.16
32/23ºC DB/WB
TC 3.52 3.39 3.33 3.07 SC 2.99 2.95 2.93 2.86 Input 1.03 1.08 1.16 1.20
MCA-18HRN1
Cooling Outdoor conditions (DB)
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC
21/15ºC DB/WB
TC 5.46 5.19 4.93 4.72 SC 4.04 4.00 3.94 3.96
Input 1.58 1.71 1.79 1.84
24/17ºC DB/WB
TC 5.62 5.35 5.09 4.77 SC 4.21 4.18 4.12 4.01
Input 1.67 1.79 1.86 1.96
27/19ºC DB/WB
TC 5.72 5.46 5.30 4.93 SC 4.24 4.20 4.13 4.04
Input 1.71 1.81 1.90 2.00
32/23ºC DB/WB
TC 5.83 5.62 5.51 5.09 SC 4.96 4.89 4.85 4.73
Input 1.79 1.86 2.00 2.07
MCAC-UTSM-2008-11 Capacity Tables
Indoor Units 15
7.2 Heating Capacity MCA-12HRN1
Heating Outdoor conditions
Indoor Conditions (DB) (kW) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB
15ºC
TC
5.20 4.20 3.44 3.12
Input
1.13 0.98 0.84 0.79
20ºC
TC
5.04
4.00
3.24 3.04
Input
1.24
1.05
0.92 0.85
27ºC
TC
4.72 3.76 3.04 2.96
Input
1.31 1.13 1.00 0.92
MCA-18HRN1
Heating Outdoor conditions
Indoor Conditions (DB) (kW) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB
15ºC
TC
7.80 6.30 5.16 4.68
Input
2.05 1.77 1.52 1.43
20ºC
TC
7.56
6.00
4.86 4.56
Input
2.24
1.90
1.67 1.54
27ºC
TC
7.08 5.64 4.56 4.44
Input
2.38 2.05 1.81 1.67
Remark:
TC: Total capacity ; kW SC: Sensible heat capacity ; kW Input: Input power ; kW
Electric Characteristics MCAC-UTSM-2008-11
16 Indoor Units
8. Electric Characteristics
Model
Indoor Units Power Supply Indoor Fan Motor
Hz Voltage
Min. Max. MCA MFA kW FLA MCA-12HRN1 50 220-240V 198V 254V 0.33 25 0.045 0.264 MCA-18HRN1 50 220-240V 198V 254V 0.33 25 0.045 0.264
Remark:
MCA: Min. Current Amps. (A) MFA: Max. Fuse Amps. (A) KW: Fan Motor Rated Output (kW) FLA: Full Load Amps. (A)
9. Sound Levels
1.0m
FOUR-WAY CASSETTE TYPE
Microphone
Model
Noise level dB(A)
H M L MCA-12HRN1 41 38 35 MCA-18HRN1 42.5 39.4 35.8
MCAC-UTSM-2008-11 Exploded View
Indoor Units 17
10. Exploded View
MCA-12HRN1 MCA-18HRN1
No. Part Name Quantity No. Part Name Quantity
1 Drainage pan ass'y 1 11 E-Part box cover 1 2 Centrifugal fan 1 12 Drain pump Holder 1 3 Installation bracket 4 13 Drain pump 1 4 Evaporator fixing hanger 1 14 Right clapboard ass'y 1 5 Motor 1 15 Partition board 1 6 Motor base 1 16 Evaporator fixing board ass'y 1 7 Base ass'y 1 17 Evaporator ass'y 1 8 Board 1 18 Evaporator temp. sensor ass'y 1 9 Sealed board ass'y 1 19 Room temp. sensor ass'y 1 10 E-part box ass'y 1 20 Remote controller 1
10.1 Main controller ass'y 1 21 Remote controller holder 1
10.2 Motor capacitor 1 22 Panel ass'y 1
10.3 Wire joint, 7p 1 22.1 Swing motor 1
10.4 Wire joint 1 22.2 Display board 1
10.5 Transformer 1
10.5
Accessories MCAC-UTSM-2008-11
18 Indoor Units
11. Accessories
Installation fittings
Name Shape Quantity
1. Expansible hook
4
2. Installation hook
4
3. Installation paper board
1
Drainpipe Fittings
4. Out-let pipe sheath
1
5. Out-let pipe clasp
1
6. Tightening band
20
7. Drain joint
1
Remote controller & Its holder
8. Remote controller
1
9. Remote controller holder
1
10. Mounting screw(ST2.9×10-C-
H)
2
11. Alkaline dry batteries (AM4)
2
Others
12. Owner's manual
1
13. Installation manual
1
12. The Specification of Power
Type MCA-12HRN1 MCA-18HRN1
Power
Phase 1-phase 1-phase
Frequency and Voltage 220-240V, 50Hz 220-240V, 50Hz
Circuit Breaker/ Fuse (A) 40/25 40/25
Indoor Unit Power Wiring (mm2) 3×2.5 3×2.5
Indoor/Outdoor Connecting Wiring
2.5 2.5 2.5
Outdoor Unit Power Wiring
Strong Electric Signal 5×2.5 5×2.5
Weak Electric Signal 1-core shield wire 1×0.5 1-core shield wire 1×0.5
MCAC-UTSM-2008-11 Field Wiring
Indoor Units 19
13. Field Wiring
MCA-12HRN1
Field Wiring MCAC-UTSM-2008-11
20 Indoor Units
MCA-18HRN1
MCAC-UTSM-2008-11 Four-way Cassette Type
Indoor Units 21
Four-way Cassette Type
1. Features .................................................................................................... 22
2. Specifications .......................................................................................... 24
3. Dimensions .............................................................................................. 27
4. Service Space .......................................................................................... 28
5. Wiring Diagrams ...................................................................................... 29
6. Air Velocity and Temperature Distributions .......................................... 31
7. Capacity Tables ........................................................................................ 32
8. Electric Characteristics ........................................................................... 38
9. Sound Levels ........................................................................................... 38
10. Exploded View ....................................................................................... 39
11. Accessories ............................................................................................ 51
12. The Specification of Power ................................................................... 51
13. Field Wiring ............................................................................................ 52
Features MCAC-UTSM-2008-11
22 Indoor Units
1. Features
(1) Ultra thin machine body to easy installation and maintenance. 24K:230mm, 30-48K:300mm.
(2) Different color panels to choose: White, Gray, Blue, Black
(3) The swing angle of the first louver are 40~42 degrees and the second louver are 37~38 degrees.
(4) 4 speeds available, optional super high fan speed design, suitable for the large building over 3m high.
(5) Adding digital tube displaying on the display board. LED can display the Error Code to make the malfunction checking easier.
(6) Reserve spaces for air side-outlet, it is available to connect duct pipe hence Air supplying from the four sides to nearby small room.
MCAC-UTSM-2008-11 Features
Indoor Units 23
(7) Stylish design is harmonious with any interior decoration and creates and elegant environment.
(8) Built-in water pump with 750mm pumping head.
(9) Fresh air makes life more healthy and comfortable.
Specifications MCAC-UTSM-2008-11
24 Indoor Units
2. Specifications
Model MCC-24HRN1 MCC-30HRN1 Code 220042500390 220042600250 Power supply V-ph-Hz
220~240-1-50 220~240-1-50
Cooling
Capacity kW 7.1 9.0 Input W 2700 3500
Heating
Capacity kW 7.6 9.5 Input W 2800 3600
Indoor fan motor
Model YDK80-6E YDK90-6E Brand Welling Welling Input W 120/110/100/90 165/143/116/100 Capacitor uF 3.5uF/450V 3.5uF/450V Speed(Hi/Mi/Lo) r/min 800/670/550/400 840/770/640/550
Indoor coil
Number of rows 2 2 Tube pitch(a)×row pitch(b) mm 21×13.37 21×13.37 Fin spacing mm 1.5 1.5 Fin type (code) Hydrophilic aluminum Hydrophilic aluminium Tube outside dia.and type mm φ7 Inner grooved copper tube φ7 Inner grooved copper tube
Coil length × height × width
mm 1959.4×168×26.74 1959.4×252×26.74
Number of circuits 16
12
Indoor air flow (Hi/Mi/Lo) m3/h 1220/1010/822
1538/1296/1124
Indoor noise level (sound pressure) dB(A) 48/44/40 50/46//42
Indoor unit
Dimension (W×H×D)(body) mm 840×230×840 840×300×840 Packing (W×H×D)(body) mm 955×247×955 955×317×955 Dimension (W×H×D)(panel) mm 950×55×950 950×55×950 Packing (W×H×D)(panel) mm 1035×90×1035 1035×90×1035 Net/Gross weight(body) kg 29/36 35/42
Net/Gross weight(panel) kg 6/9 6/9 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/Gas side mm φ9.5/φ15.9 φ12.7/φ19 Drainage water pipe diameter mm ODφ32 ODφ32
Connection wiring
Power wiring mm2 3×4.0 3×4.0
Strong electric signal wiring mm2 3×2.5 3×2.5
Weak electric signal wiring mm2 1-core shield wire 1×0.5 1-core shield wire 1×0.5 Controller R05/BGE(standard) R05/BGE(standard) Operation temperature 17-30 17-30
Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB;
2. Nominal heating capacities are based on the following conditions: Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB;
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room.
MCAC-UTSM-2008-11 Specifications
Indoor Units 25
Model MCC-30HRN1-R MCC-36HRN1 Code 220042600270 220042700210 Power supply V-ph-Hz
380~415-3-50 220~240-1-50
Cooling
Capacity kW 9.0 10.5
Input W 3500
3850
Heating
Capacity kW 9.5 12.0
Input W 3700
4050
Indoor fan motor
Model YDK90-6E YDK90-6E
Brand Welling Welling
Input W 165/143/116/100 165/143/116/100
Capacitor uF 3.5uF/450V 3.5uF/450V
Speed(Hi/Mi/Lo) r/min 840/770/640/550 840/770/640/550
Indoor coil
Number of rows 2 2
Tube pitch(a)×row pitch(b) mm 21×13.37 21×13.37
Fin spacing mm 1.5 1.5
Fin type (code) Hydrophilic aluminum Hydrophilic aluminum
Tube outside dia.and type mm φ7 Inner grooved copper tube φ7 Inner grooved copper tube
Coil length × height × width
mm 1959.4×252×26.74 1959.4×252×26.74
Number of circuits 12 12 Indoor air flow (Hi/Mi/Lo) m3/h 1538/1296/1124 1538/1296/1124 Indoor noise level (sound pressure) dB(A) 50/46//42 50/46//42
Indoor unit
Dimension (W×H×D)(body) mm 840×300×840 840×300×840
Packing (W×H×D)(body) mm 955×317×955 955×317×955
Dimension (W×H×D)(panel) mm 950×55×950 950×55×950
Packing (W×H×D)(panel) mm 1035×90×1035 1035×90×1035
Net/Gross weight(body) kg 35/42 35/42
Net/Gross weight(panel) kg 6/9 6/9 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/Gas side mm φ12.7/φ19 φ12.7/φ19 Drainage water pipe diameter mm ODφ32 ODφ32
Connection wiring
Power wiring mm2 5×2.5 3×4.0
Strong electric signal wiring mm2 3×1.0 3×2.5
Weak electric signal wiring mm2 1-core shield wire 1×0.5 Controller R05/BGE(standard) R05/BGE(standard) Operation temperature
17-30 17-30
Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB;
2. Nominal heating capacities are based on the following conditions: Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB;
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room.
Specifications MCAC-UTSM-2008-11
26 Indoor Units
Model MCC-36HRN1-R MCC-48HRN1-R Code 220042700230 220042800310 Power supply V-ph-Hz
380~415-3-50 380~415-3-50
Cooling
Capacity kW 10.5 14
Input W
3850
4881
Heating
Capacity kW 12.0 15
Input W
4100
4941
Indoor fan motor
Model YDK90-6E YDK90-6E
Brand Welling Welling
Input W 165/143/116/100 165/143/116/100
Capacitor uF 3.5uF/450V 3.5uF/450V
Speed(Hi/Mi/Lo) r/min 840/770/640/550 840/770/640/550
Indoor coil
Number of rows 2 2
Tube pitch(a)×row pitch(b) mm 21×13.37 21×13.37
Fin spacing mm 1.5 1.5
Fin type (code) Hydrophilic aluminum Hydrophilic aluminum
Tube outside dia.and type mm φ7 Inner grooved copper tube φ7 Inner grooved copper tube
Coil length × height × width
mm 1959.4×252×26.74 1959.4×252×26.74
Number of circuits 12 12 Indoor air flow (Hi/Mi/Lo) m3/h 1538/1296/1124 1538/1296/1124 Indoor noise level (sound pressure) dB(A) 50/46//42 50/46//42
Indoor unit
Dimension (W×H×D)(body) mm 840×300×840 840×300×840
Packing (W×H×D)(body) mm 955×317×955 955×317×955
Dimension (W×H×D)(panel) mm 950×55×950 950×55×950
Packing (W×H×D)(panel) mm 1035×90×1035 1035×90×1035
Net/Gross weight(body) kg 35/42 35/42
Net/Gross weight(panel) kg 6/9 6/9 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/Gas side mm φ12.7/φ19 φ12.7/φ19 Drainage water pipe diameter mm ODφ32 ODφ32
Connection wiring
Power wiring mm2 5×2.5 5×2.5
Strong electric signal wiring mm2 3×1.0 3×1.0
Weak electric signal wiring mm2 Controller R05/BGE(standard) R05/BGE(standard) Operation temperature
17-30 17-30
Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB;
2. Nominal heating capacities are based on the following conditions: Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB;
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room.
MCAC-UTSM-2008-11 Dimensions
Indoor Units 27
3. Dimensions
3.1 MCC-24HRN1
3.2 MCC-30HRN1 MCC-30HRN1-R MCC-36HRN1 MCC-36HRN1-R MCC-48HRN1-R
Service Space MCAC-UTSM-2008-11
28 Indoor Units
4. Service Space
The indoor unit should be installed in a location that meets the following requirements:
There is enough room for installation and maintenance.
The ceiling is horizontal, and its structure can endure the weight of the indoor unit.
The outlet and the inlet are not impeded, and the influence of external air is the least.
The air flow can reach throughout the room.
The connecting pipe and drainpipe could be extracted out easily.
There is no direct radiation from heaters.