Midea MAW08V1DWT, MAW12V1DWT, MAW10V1DWT User Manual

Window Air Conditioner
Capacity: 8000 ~ 12000BTU/h
en
USER MANUAL
Warning notices: Before using this product, please read this manual carefully and keep it for future reference. For additional support, please call customer service at 1-866-646-4332.
The design and specifications are subject to change without prior notice for product improvement. Consult with your dealer or the manufacturer for details.
version D - 03 - 2020
version B - 02 - 2020
Free 3 months
extension* of the
original limited warranty
period! Simply text a
picture of your proof of
purchase to:
1-844-224-1614
*The warranty extension is for the
three month s immediat ely following
the completion of the product’s
original warran ty period.
MAW12V1DWT
MAW10V1DWT
MAW08V1DWT
midea.com
Owner’s Manual
0
Safety Precautions ............................................................................ 3
Operating Instructions ..................................................................... 8
1
Installation Instructions ...................................................................
2
Care and Cleaning ........................................................................... 24
3
Troubleshooting Tips ...................................................................... 25
4
Warranty ............................................................................................ 27
5
13
Read This Manual
Inside you’ll find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the troubleshooting tips - you should be able to fix most of them quickly before calling service. These instructions may not cover every possible condition of use, so common sense and attention to safety is required when installing, operating and maintaining this product.
CAUTION
• For support, please call the Service Center at 1-866-646-4332.
• This appliance is not intended for use by people (including children) with reduced physical, sensory, or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• The appliance shall be installed in accordance with national wiring regulations.
• Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
Page 2
Safety Precautions
To prevent injury to the user or other people and property damage, the instructions shown here must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The level of risk is shown by the following indications.
Precautions
Safety
WARNING
CAUTION
NOTICE
This symbol indicates a hazardous situation which, if not avoided, could result in death or serious injury.
This symbol indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury.
This symbol addresses practices not related to physical injury.
WARNING
• Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.
• Plug in power cord plug properly. Otherwise, it may cause electric shock or fire due to excess heat generation.
• Do not modify power cord length or share the outlet with other appliances as it may cause electric shock or fire due to overheating.
• Always ensure effective grounding. Incorrect grounding may cause electric shock.
• Unplug the unit if you notice unusual sounds or smells or smoke coming from it. A damaged product may cause fire and electric shock.
• Ventilate room before operating the air conditioner if there is a gas leakage from another appliance.
• Do not operate or stop the unit by inserting or pulling out the power cord plug.
• Do not operate with wet hands or in very humid enviroments. It may cause electric shock.
• Do not allow water to come into contact with any electric parts. It may cause failure or electric shock.
• Do not use the socket if it is loose or damaged. It may cause fire and electric shock.
• Do not use or keep the power cord close to heating appliances. It may cause fire and electric shock.
• Do not use any devices or materials for installation that are not recommended in this manual.
Page 3
Precautions
Safety
WARNING
• Do not disassemble or modify unit. It may cause failure and electric shock.
• Do not damage or use an alternate power cord. It may cause fire and electric shock. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service center or a similarly qualified person in order to avoid a hazard.
• Do not direct airflow straight into persons to avoid possible health hazard.
• Do not open the unit during operation. It may cause electric shock.
• Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause an explosion or fire.
• Do not let children hang on the air conditioner or bracket. A serious injury may occur.
• Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prongs from the power cord.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
• Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation.
• Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille.
CAUTION
• When the air filter is to be removed, do not touch the metal parts of the unit. It may cause injury.
• When the unit needs cleaning, switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire, electric shock or injury.
• Do not place obstacles around air inlets or inside of air outlet. It may cause failure or accident.
• Clean with a soft cloth only. Do not use strong detergents that contain wax or thinners as it may damage the product.
• Use caution when unpacking and installing. Sharp edges could cause injury.
• Do not clean the air conditioner with water. Water may enter the unit and degrade the insulation which could lead to
electric shock.
Page 4
CAUTION
• Do not put a pet or house plant where it will be exposed to direct air flow. This could injure the pet or harm the plant.
• Hold the plug by the head of the power plug when taking it out. Otherwise, it may cause electric shock and damage.
• Ensure that the installation is properly secured to prevent the product from potentially falling.
• Do not place heavy objects on the power cord and ensure that the cord is not compressed.
Otherwise, there is danger of fire or electric shock.
• If water is spilled on the unit, turn off the unit and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.
• Do not use near gas stove or other gas burning appliances, as air flow may affect gas combustion.
• Do not use for any purpose other than room comfort. Do not use this air conditioner to preserve precision devices, food, pets, plants,
and art objects. It may cause deterioration.
• Turn off the main power switch if the unit is not to be used for an extended time.
• Always insert the filters securely. Clean filter once every two weeks. Operation without filters may cause failure.
• Do not drink water drained from the air conditioner.
Precautions
Safety
Page 5
Precautions
Safety
Operation of Current Device
Plug in & press RESET
RESET
TEST
Grounding type wall receptacle
Do not, under any circumstances, cut, remove or bypass the grounding prong.
The power supply cord contains a current device that senses damage to the power cord. Test your power supply cord as follows:
1. Plug in the air conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
3. Press the RESET Button. You will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the plug head.)
NOTICE
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire.
In the event that the power supply cord is damaged, it can not be repaired. It must be replaced with a cord from the manufacturer.
Power supply cord with 3-prong grounding plug and current detection device.
NOTICE
• Do not use this device to turn the unit on or off.
• Always make sure the RESET button is pushed in for correct operation.
• The power supply must be replaced if it fails to reset when either the TEST button is pushed, or it can not be reset. Please contact Customer Service.
Page 6
EXPLANATION OF SYMBOLS DISPLAYED ON THE UNIT
Precautions
Safety
WARNING
CAUTION
CAUTION
CAUTION
This symbol shows that this appliance used a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.
This symbol shows that the operation manual should be read carefully.
This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
This symbol shows that information is available such as the operating manual or installation manual.
WARNING
• Do not try to accelerate the defrosting process or methods of cleaning that are
not recommended by the manufacturer.
• The appliance shall be stored in a room without a continuously operating ignition
source (for example, open flames or an operating gas appliance) or an ignition source (for example, an operating electric heater) close to the appliance. The appliance shall also be stored in a room without ignition sources.
• Do not pierce or burn.
• Be aware that the refrigerants may not contain an odor.
• Compliance with national gas regulations shall be observed.
• Keep ventilation openings clear of obstruction.
• The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specied for operation.
• Unit is only to be serviced by a Midea authorized servicer, please call Customer
Service at 1-866-646-4332 for support.
• Flammable refrigerant R32 is used within air conditioner. Please follow the
instructions carefully to handle, install, clean, and service the air conditioner to avoid damage or hazard. Do not dispose of air conditioner in regular trash. Contact qualified agency for proper disposal.
• No open fire or devices that generate spark/arcing shall be around the air
conditioner to avoid causing ignition of the flammable refrigerant used. Please follow the instructions carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
• Be aware that refrigerants may not contain an odor.
Page 7
Instructions
Operating
Operating Instructions
Normal Sounds
High Pitched Chatter
+LJKHI´FLHQF\FRPSUHVVRUV PD\KDYHDKLJKSLWFKHG VRXQGGXULQJFRROLQJF\FOH
Vibration
Unit may vibrate and
PDNHQRLVHEHFDXVH RISRRUZDOORU ZLQGRZFRQVWUXFWLRQ RULQFRUUHFW LQVWDOODWLRQ
Trickling Sound
'URSOHWVRIZDWHUKLWWLQJ FRQGHQVHUGXULQJQRUPDO RSHUDWLRQPD\FDXVHD WULFNOLQJVRXQG
Sound Performance
1
Sound of Rushing Air
In front of the unit, you may hear the sound of rushing air being moved by the fan.
Gurgle/Hiss
*XUJOLQJRUKLVVLQJ
noises may be heard
GXHWRUHIULJHUDQWµRZLQJ WKURXJKHYDSRUDWRU GXULQJQRUPDORSHUDWLRQ
The following table shows the sound performance data for these window air conditioners. Please use your specific model number to reference the correct sound power number
in the table.
Model Number Sound Power, dB(A)*
MAW08V1QWT 42
MAW10V1QWT 42
MAW12V1QWT 42
* per ISO 3744 at low fan speed
Page 8
Air Conditioner Operation
WARNING
To reduce the risk of fire, electrical shock, or injury to people or property, read the SAFETY PRECAUTIONS before operating this appliance.
NOTICE
The cool circuit has an automatic 3 minutes time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping.
To begin operating the air conditioner, follow these steps:
1. Plug in the air conditioner (be sure to follow the power cord instructions on Page 6).
2. Turn the power on to the air conditioner, using the ON/OFF button.
3. Set the thermostat to the coldest temperature setting.
4. Select the Cool mode setting.
5. Adjust the louver for comfortable air flow (see Air Directional Louvers).
6. Once the room has cooled, adjust the thermostat to the setting you find most comfortable.
7. Make sure the air flow inside and outside is not obstructed by anything.
Outdoor temp.: 64°F ~ 109°F / 18°C ~ 43°C
Cooling Operation
(64°F ~ 125°F / 18°C ~ 52°C for special tropical models) Indoor temp.: 60°F ~ 90°F / 16°C ~ 32°C
NOTICE
• The relative humidity of room should be less than 80%. If the unit is used in a condition with a relative humidity over 80%, there will be condensed water on the surface of the unit.
• Performance may be reduced outside of these operating temperatures.
Air Directional Louvers
The louvers will allow you to direct the air flow up or down (on some models) and left or right throughout the room as needed. Pivot horizontal louvers until the desired up/down direction is obtained.
Move the louvers from side to side until the desired left/right direction is obtained.
Lever
Lever
Instructions
Operating
Lever
Air Direction
Air Direction
Page 9
Loading...