WIRED REMOTE CONTROLLER
Installation and Owner’s Manual
IMPORTANT NOTE:
Read this manual carefully before
installing or operating your wired
remote controller. Make sure to save
this manual for future reference.
MODEL:
KJR-120G1/TFBG-E(5V)(For high wall models)
KJR-120G2/TFBG-E(12V) (For Duct/Cassette/Floor ceiling models)

● This manual gives detailed description of the precautions that should
be brought to your attention during operation.
● To ensure the correct service of the wired controller, read this manual
carefully before using the unit.
● Keep this manual after reading for future reference.

CONTENTS
1. SAFETY PRECAUTION....................................................................... 1
2. INSTALLATION ACCESSORY.............................................................. 2
3. INSTALLATION METHOD....................................................................4
4. APPENDIX INSTALL THE WIRE CONTROLLER KIT...............................10
5. SPECIFICATION...............................................................................16
6. WIRED CONTROLLER FEATURES AND FUNCTIONS...........................17
7. WIRED CONTROLLER DISPLAY.........................................................18
8. WIRED CONTROLLER BUTTONS.......................................................19
9. PREPARATORY OPERATION..............................................................20
10. OPERATION...................................................................................21
11. TIMER FUNCTIONS........................................................................27
12. WEEKLY TIMER.............................................................................30
13. FAULT ALARM HANDING..............................................................37
14.TECHNICAL INDICATION AND REQUIREMENT ...............................37

1
Read the safety precautions carefully before installing the unit.
Stated below are important safety issues that must be obeyed.
Means improper handling may lead to personal death or severe injury.
Means improper handling may lead to personal injury or property loss.
WARNING
CAUTION
Please entrust the distributor or professionals to install the unit.
Installation by other persons may lead to imperfect installation, electric shock or fire.
Adhere to this installation manual.
Imporper installation may lead to electric shock or fire.
Reinstallation must be performed by professionals.
WARNING
Do not install the unit in a place vulnerable to leakage of flammable gases.Once
flammable gases are leaked and left around the wire controller, fire may occure.
Do not operate with wet hands or let water enter the wire controller. Otherwise,
electric shock may occur.
The wiring should adapt to the wire controller current. Otherwise, electric leakage or
heating may occur and result in fire.
The specified cables shall be applied in the wiring. No external force may be applied
to the terminal. Otherwise, wire cut and heating may occur and result in fire.
NOTE
Do not uninstall the unit randomly.
Random uninstalling may lead to abnormal operation, heating or fire of the air condition.
1
2
3
4
1. SAFETY PRECAUTION

2
2. INSTALLATION ACCESSORY
Don’t install at the place where cover with heavy oil, vapor or sulfureted
gas, otherwise, this product would be deformed that would lead to
system malfunction.
Select the installation location
Preparation before installation
1. Please confirm that all the following parts you have been supply.
2. Prepare the following assemblies on the site.
1
2
3
4
5
3
2
M4X20 (For Mounting on the Wall)
M4X25 (For Mounting on switch box)
1
2
1
6
7
8
3
2
No. Name
Qty. Remarks
Wire controller
Installation and owner’s manual
For Mounting on the Wall
Switch box
Wiring Tube(Insulating
Sleeve and Tightening
Screw)
Qty.(embeded
into wall)
Plastic screw bars
Screws
Wall plugs
For fixing on switch box
(Optional)
No.
Name
Remarks
Specification
(only for reference)
Screws
1
1
1
Battery
The connection cable
1
1

3
2. INSTALLATION ACCESSORY
WIRED CONTROLLER INSTALLATION PRECAUTION
1. This manual provides the wired controller installation method. Refer
to the wiring diagram in this installation manual to wire the wired
controller with the indoor unit.
2. The wired controller works in a low voltage loop circuit. Do not
connect directly to 208/230V and 460V. Do not wire this kind of wire
into a loop. Wiring clearance between the configured tubes should
range 11.81−19.69 inches (30−50 cm) or above.
3. The shielded wire of the wired controller must be properly grounded.
4. Upon finish the wire controller connection, do not employed
tramegger to detect the insulation.

4
3. INSTALLATION METHOD
Fig 3-1
1.Wired Remote Controller Dimensions
123mm
(4.8”)
120mm
(4.7”)
18.5mm
(0.7”)
83.5mm
(3.3”)
46mm
(1.8”)
62mm
(2.4”)
Fig 3-2
2.Wiring Connection Diagram
red
black
yellow
brown
red
black
yellow
brown
Insert of the
mainboard CN40
Wire controller
Indoor unit mainboard
4-Core Shield Cable, the length
is decided by installation
-----------------------------------
-----------------------------------
-----------------------------------
-----------------------------------

5
3. INSTALLATION METHOD
Connect the female joint of the wires group from the mainboard
with the male joint of the connective wires group. (See Fig.3-3(A))
Connect the other side of the connective wires group with the male
joint of the wires group leads from the wire controller.(See Fig.3-3(A))
Fig 3-3(A)
Mainboard
4-core shielding wire
3.Wiring figure
Model A:KJR-120G2/TFBG-E(12V)
Model B:KJR-120G1/TFBG-E(5V)
The connection cable
CN40
Fig 3-3(B)
Adapter board
Display board
4-core shielding wire
The connection
cable
CN101

6
3. INSTALLATION METHOD
Fig 3-4
Fig 3-5
4.Wire controller upper part Remove
Insert a flat screwdriver into the slots in the
lower part of the wire controller (2 places).
Remove the upper part of the wire controller
(Fig.3-4)
For surface mounting, fasten the back plate on the wall with the 3
screws (M4x20) and plugs. (Fig.3-5)
Slots
NOTE: The PCB is mounted in the upper part
of the wired controller. Be careful not to
damage the board with the screwdriver.
5. Fasten the wire controller back plate
Back plate
Screws (M4×20)
Connect the female joint of the wires group from the adapter board
with the male joint of theconnective wires group. Next, connect the
other side of the adapter board with the displayboard. (See Fig.3-3(B))
Connect the other side of the connective wires group with the male
joint of the wires group leads from the wire controller. (See Fig.3-3(B))
Install the Adapter Board and the Display Board on the High Wall
(See the Appendix for instructions).

7
Place the battery in the unit and ensure the positive side of the
battery is in accordance with the polarity markings.(See Fig.3-7)
Set the correct time before operating. Batteries in the wired controller
can maintain the correct time during a power failure. When the power
is restored and the displayed time is not correct, replace the battery.
Fig 3-7
Fig 3-6
3. INSTALLATION METHOD
Switch box
Back plate
For switch box mounting, fasten the back plate on the switch box with
2 screws (M4x25) and fasten it on the wall with 1 screw (M4x20).
(Fig.3-6)
6. Battery installation
Screw (M4×20)
Screws (M4×25)
NOTE: Place on a flat surface. Be careful not to distort the wire
controller’s back plate by over−tightening the mounting screws.

8
3. INSTALLATION METHOD
7. Wire the indoor unit
1 from the rear;
2 from the bottom;
3 from the top;
There are three methods:
4. Notch the part for the wiring to pass through with a nipper tool.
PCB
PCB
PCB
1
1
1
2
3

9
Fig 3-8
3. INSTALLATION METHOD
Putty
Putty
Putty
Trap
Trap
Trap
Fig 3-9
IMPORTANT: All the pictures
in this manual are for
illustration purposes only.
Your wire controller may
differ slightly.
8. Reattach the wire controller’s upper part
While adjusting and mounting the upper case, avoid clamping the
wiring during installation. (Fig 3-9)
NOTE: DO NOT allow water to enter the remote control.
Use the trap and putty to seal the wires.