Midea INVERTER SPLIT TYPE ROOM AIR CONDITIONER User Manual

Before using your air conditioner, please read
this manual carefully and keep it for future reference.
INVERTER SPLIT TYPE
ROOM AIR CONDITIONER
Read This Manual
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review the chart of Troubleshooting Tips first, you may not need to call for service.
-
1
CONTENTS
Contact an authorised service technician for repair or maintenance of this unit. Contact the installer for installation of this unit. The air conditioner is not intended for use by young children or invalids
without supervision.
Young children should be supervised to ensure that they do not play with the
air conditioner. If the power cord is to be replaced, replacement work shall be performed by authorised personnel only. Installation work must be performed in accordance with the national wiring standards by authorised personnel only.
!
CAUTION
SOCIABLE REMARK
Sociable remark......................................................................................................................2
SAFETY PRECAUTIONS
Warning .................................................................................................................................3
Caution ..................................................................................................................................4
OPERATING INSTRUCTIONS
Parts names ........... .............................................................................................................5
Operating temperature...........................................................................................................7
Manual operation ..................................................................................................................7
Airflow direction control .........................................................................................................8
How the air conditioner works ...............................................................................................9
CARE AND MAINTENANCE
Care and maintenance ..........................................................................................................10
TROUBLESHOOTING TIPS
Troubleshooting tips .............................................................................................................14
OPERATION TIPS
Operation tips ............ ..........................................................................................................12
2
SOCIABLE REMARK
The follow contents apply only the countries of Europe.
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least
free of charge.
C) The manufacture will take back the old appliance for disposal at least free of
charge to the user.
D) As old products contain valuable resources, they can be sold to scrap metal
dealers.
Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.
3
SAFETY PRECAUTIONS
3
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Meanings of symbols used in this manual are as shown below.
!
!
WARNING
Always do this.
Never do this.
!
CAUTION
This symbol indicates the possibility of injury or damage to property.
Connect with the power
properly.
Do not modify power cord length or share the outlet with other appliances
Always ensure effective earthing.
Disconnect the power if strange sounds, smell, or smoke comes from it.
Ventilate room before operating air conditioner if there is a gas leakage from another appliance.
Otherwise, it may cause electric shock or fire due to heat generation.
excess
It may cause electric shock or fire due to heat generation.
No earthing may cause electric shock.
It may cause fire and electric shock.
It may cause explosion, fire and, burns.
It may cause electric shock or fire due to heat generation.
It may cause electric shock.
It may cause failure of machine or electric shock.
It contains contaminants and could make you sick.
It may cause fire and electric shock.
It may cause electric shock or fire.
This could damage your health.
No installation may cause fire and electric shock.
It may cause electric shock.
It may cause an explosion or fire.
It may cause failure and electric shock.
Do not operate or stop the unit by switching on or off the power.
Do not operate with wet hands or in damp environment.
Do not allow water to run into electric parts.
Do not drink water drained from air conditioner.
Do not use the power cord close to heating appliances.
Do not damage or use an unspecified power cord.
Do not direct airflow at room occupants only.
Always install circuit breaker and a dedicated power circuit.
Do not open the unit during operation.
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
Do not disassemble or modify unit.
!
!
!
!
!
!
WARNING
!
Use the correctly rated breaker or fuse.
There is risk of fire or electric shock.
!
4
SAFETY PRECAUTIONS
!
CAUTION
When the air filter is to be removed, do not touch the metal parts of the unit.
It may cause an injury.
Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury.
Operation with windows opened may cause wetting of indoor and soaking of household furniture.
When the unit is to be cleaned, switch off, and turn off the circuit breaker.
Stop operation and close the window in storm or hurricane.
Use caution when unpacking and installing. Sharp edges could cause injury.
Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
This could injure the pet or plant.
Do not put a pet or house plant where it will be exposed to direct air flow.
Ventilate the room well when used together with a stove, etc.
An oxygen shortage may occur.
Do not use this air cond­itioner to preserve preci­sion devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
It may cause failure of product or fire.
Do not use for special purposes.
Turn off the main power switch when not sing the unit for a long time.
u
If water enters the unit, turn the unit off and disconnect the power , contact a qualified service technician.
!
!
!
!
!
!
!
It may cause failure of appliance or accident.
Appearance may be deteriorated due to change of product color or scratching of its surface.
Do not place obstacles around air-inlets or inside of air-outlet.
Do not use strong detergent such as wax or thinner. Use a soft cloth for cleaning.
If bracket is damaged, there is concern of damage due to falling of unit.
There is danger of fire or electric shock.
Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
Do not place heavy object on the power cord and take care so that the cord is not compressed.
Operation without filters may cause failure.
Always insert the filters securely. Clean filter once every two weeks.
!
!
!
5
OPERATING INSTRUCTIONS
Indoor unit
3
2
4
1
6
7
5
8. Connective cable
9. Connective pipe
10. Stop valve
Outdoor unit
NOTE: The indoor unit you purchased would like one of the following. There is a slightly
difference on front panel and display window, but the features are the same.
NOTE:
All the pictures in this manual are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall prevail.
Air inlet
Air outlet
8
9
10
Outdoor unit
Air inlet(
rear)
Air inlet
(side)
Air outlet
1. Front panel
2. Air filter(inside)
3.
4.
5. Display panel
6. Connecting pipe
7. Drain hose
Horizontal air flow louver Vertical air flow louver(inside)
Indoor unit
(A)
(B)
VLED Display Window
AUTO indication lamp
Lights up during the Auto operation.
OPERATION indication lamp
This lamp illuminates when the air conditioner is in operation.
TIMER indication lamp
Lights up during Timer operation.
Ion indication lamp(optional function)
Lights up when Clean Air feature is activated and Ionizer can generate abundant anions to fill the room with refreshing and natural air.
DEFROST indication lamp
(For cooling & heating models only): Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation.
A) Usually it displays the temperature
settings. When change the setting temperature,this indicator begins to flash, and stops 20 seconds later.
TEMPERATURE indicator
Signal receptor
Signal receptor
Special functions
Air quality is the key to comfort, this air conditioner is equipped with Ionizer device. Ionizer can generate abundant anions to fill the room with refreshing and nature air. Your whole family will enjoy a natural, pure and healthy air everyday.
Clean Air function(optional)
Function used after the Shut Down of cooling operation to clean the Evaporator and keep it as fresh for the next operation. This function is easy to be operated as it is accessed through the Remote Controller.
For cooling & heating models, the air conditioner will operate : FAN ONLY mode at Low fan speed(13 minutes)--Heating operation with LOW fan speed (1 minute)---FAN ONLY
operation(2 minutes)--Stop Operation---Turn off the unit.
This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode. Before select the function, it is recommended to run the air conditioner under Cooling operation for about half an hour. Once the Auto Clean function is activated, all TIMER setting will be cancelled. During Auto Cleaning operation, Press the AUTO CLEAN button again will stop the operation and turn off the unit.
Note:
For cooling only models, the air conditioner will operate under FAN ONLY mode at LOW fan speed for 16 minutes, and then stop the operation and the unit turn off.
Auto Clean function(optional)
Follow Me function(optional)
To activate the Follow Me feature, point the remote control towards the unit and press the Follow Me button. T
If the unit does not receive the Follow Me signal during any 7 minute interval, the Follow Me mode will be cancelled automatically.
he remote display is actual temperature at its location. The remote control will send
this signal to the air conditioner every 3 minutes interval until press the Follow Me button again.
The remote control serves as a remote thermostat allowing for the precise temperature control at its location.
6
OPERATING INSTRUCTIONS
B) It displays the room temperature when the air conditioner is in FAN only operation. C) Displays the malfunction code or protection code. D) When SELF CLEAN feature is activated, it displays .
This display is separated into five zones. The zones illuminate based on the compressor current frequency. For example, higher frequency will illuminate more zones.
OPERATION FREQUENCY display:
,,
,,
7
Manul operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted.
OPERATING INSTRUCTIONS
Manual operation
NOTE: This manual does not include Remote Controller Operations, see the <<Remote Controller Instruction>> packed with the unit for details.
Auto/Cool
Manual control button
Operating temperature
Mode
Cooling operation
Heating operation
Drying operation
Temperature
1. If air conditioner is used outside of the above conditions, certain safety protection features may come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.
Suggestion: For the unit adopts an Electric Heater, when the outside ambient temperature is below 0 C, we strongly recommend you to keep the machine plugged in order to guarantee it running smoothly.
O
Room temperature
Outdoor temperature
>17 C
0C 50C
<30 C
-15 C 34 C
0C 50C
CAUTION:
~
~
~
( -15 C 50 C:For the models with
low temperature cooling system)
~
>10 C
Open and lift the front panel up to an angle until it remains fixed with a clicking sound.
Close the panel firmly to its original position.
One press of the manual control button will lead to the forced AUTO operation. If press the button twice within five seconds, the unit will operate under forced COOL operation.
This button is used for testing purposes only. You had better not choose it. To restore the remote controller operation, use the remote controller directly.
CAUTION:
1
3
2
NOTE: The unit must be turned off before operating the manual control button. If the unit is operational, continue pressing the manual control button until the unit is off.
8
OPERATING INSTRUCTIONS
Airflow direction control
Do not operate the air conditioner for long periods the air flow direction set downward in cooling or dry mode. Otherwise,
may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings. Do not move the horizontal louver manually. Always use the SWING or AIR DIRECTION button. If you move this louver manually, it may malfunction during operation. If the louver malfunctions, stop the air conditioner once and restart it. When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds. Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area. Do not operate unit with horizontal louver in closed position. When the air conditioner is connected to power (initial power), the horizontal louver may generate a sound for 10 seconds,
this is a normal operation.
with
condensation
CAUTION
!
Lever
Range
Range
Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal/vertical louver using the remote controller. Adjust the vertical louver manually only(For some models).
Perform this function while the unit is in operation. Use the remote controller to adjust the air flow direction. The horizontal/vertical louver can be moved at an angle of 6 for each press or set to move up and down(horizontal louver) or left and right(vertical louver) automatically. Please refer to the REMOTE CONTROLLER ILLUSTRATION for details.
To set the horizontal/vertical air flow direction (automatically)
O
Adjust the vertical louver manually using the lever on the left or right side of the vertical louver arm (Depending on model). Take care not to catch fingers on the fan, horizontal louver or to damage vertical louvers. When the air conditioner is in operational and the horizontal louver is in a specific position, move the lever at left (or right, depending
on model) end of the air outlet to the desired position.
To set the horizontal air flow direction (left - right) (manually)(for some models)
,,
,,
9
To achieve optimal performance, please note the following: Adjust the air flow direction correctly so that it is not directed
on people. Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels. Close doors and windows on COOL or HEAT modes, or perfor­mance may be reduced. Use TIMER ON button on the remote controller to select a time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running. Clean the air filter periodically, otherwise cooling or heating per­formance may be reduced. Do not operate unit with horizontal louvre in closed position.
1 hour
1 hour
Set Temperature
Cooling
1
1
Heating
SLEEP operation
OPERATING INSTRUCTIONS
How the air conditioner works
Optimal operation
1
1
1 hour
1 hour
Set Temperature
SLEEP operation
7 hourstimer off
7 hourstimer off
AUTO operation
SLEEP operation
DRYING operation
When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature automatically round the temperature point set by you. If the AUTO mode is uncomfortable, you can select desired conditions manually.
When you push SLEEP button on remote controller during cooling, heating(cooling only type without), or AUTO operation , the air conditioner will automatically increase (cooling) or decrease (heating) 1 per hour for the first two hours, then hold steady for the next 5 hours, after that the unit will stop operation. The fan speed will be auto­matically controlled. This feature can maintain the most comfortable temperature and save more energy for you.
The fan speed will be automatically controlled under dry operation. During the dry operation, if the room temperature is lower than 10 C, the compressor stops operation and restarts until the room temperature is above 12 C.
O
O
10
CARE AND MAINTENANCE
Care and maintenance
Cleaning the Grille, Case and Remote Controller
Thinner
A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit. Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause
the plastic surface to crack or deform. Never use water hotter than 40 C to clean the front panel, it could cause deformation of discoloration.
CAUTIONS
No
Household
Drain
Cleaner
Care and maintenance
Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
NOTE: Supply power must be disconnectd before cleaning the indoor unit.
Filter Handle
A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it stops with a clicking sound.
2. Take hold of the handle of the air filter and lift it
up slightly to take it out from the filter holder, then pull it downwards.
Cleaning the air filter
3. Remove the AIR FILTER from the indoor unit.
Clean the AIR FILTER once two weeks.
Clean the AIR FILTER with a vacuum cleaner
or water, then dry it up in cool place.
11
CARE AND MAINTENANCE
Maintenance
Checks before operation
If you plan to idle the unit for a long time, perform the following: (1) Operate the fan for about half a day to dry the
inside of the unit.
(2) Stop the air conditioner and disconnect power.
(3) The outdoor unit requires periodic maintenance
and cleaning. Do not attempt to do this yourself. Contact your dealer or servicer.
Remove the batteries from the remote controller.
Check that the wiring is not broken off or disconnected. Check that the air filter is installed. Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time.
Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock. When cleaning the unit, first make sure that the power and circuit breaker are turned off.
Caution
Air freshening filter
Air freshening filter
1
2
4. Remove the Silver Ion filter /
Bio filter /Vitamin C filter/3M air purifier filter) from its support frame.(The removing and installation method are slightly difference, see the pictures marked and on the left.
Clean the air freshening filter at least once a
month, and replace it every 4-5 months.
Clean it with vacuum cleaner, then dry it in cool
place.
5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the
unit, taking care that the left and right edges line up correctly and place filter into position.
Air Freshening Filter(Optional filter
included: Plasma Dust Collector/
1
2
Do not touch the Plasma Dust Collector Filter within 10 minutes after opening the front panel, it may cause an electric shock.
12
OPERATION TIPS
The following events may occur during normal operation.
1.
The compressor can't restart for 3 minutes after it stops.
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
A) When heating has just starting.
B) Defrosting. C) Low temperature heating. The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner. During this condition air conditioner will stop heating operation and start defrosting automatically. The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and
the amount of frost build up on the outdoor unit.
2. A white mist may generate due to a large temperature difference between air inlet and air outlet
on COOL mode in an indoor environment that has a high relative humidity.
A white mist may generate due to moisture generated from defrosting process when the air
conditioner restarts in HEAT mode operation after defrosting.
3.
You may hear a low hissing sound when the compressor is running or has just stopped running. This sound is the sound of the refrigerant flowing or coming to a stop. You can also hear a low "squeak" sound when the compressor is running or has just stopped running. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing.
A noise may be heard due to louver restoring to its original position when power is first turned on.
4.
This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit.
5.
This is caused by the indoor unit giving off smells permeated from building material, from furniture, or smoke.
Protection of the air conditioner.
Compressor protection
Anti-cold air (Cooling and heating models only)
Defrosting (Cooling and heating models only)
A white mist coming out from the indoor unit
Low noise of the air conditioner
Dust is blown out from the indoor unit.
A peculiar smell comes out from the indoor unit.
6.
When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating models only) to the set point.
The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and
heating models only) mode.
13
OPERATION TIPS
7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed.
8. The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner decreases accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature. If a comfortable temperature can't be achieved by the air conditioner, we suggest you use a supplementary heating device.
9. Power failure during operation will stop the unit completely. For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the
remote controller. For the unit with Auto-restart feature, when the power restores, the unit restarts automatically with all the previous settings preserved by the memory function.
10. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction.
Disconnect the unit with power and then re-connect the unit with power again. Push the ON/OFF button on the remote controller to restart operation.
Heating mode (For cooling and heating models only)
Auto-restart function
14
TROUBLESHOOTING TIPS
Troubleshooting Tips
Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center.
Fuse blows frequently or circuit breaker trips frequently.
Other objects or water penetrate the air conditioner.
The remote controller won't work or works abnormally.
Other abnormal situations.
Trouble
Malfunctions
Unit does not
start
Unit not cooling
or heating
(Cooling/ heating
models only)
room very well
while air flowing
out from the air
cond tioneri
Cause
Power cut
Unit may have become
unplugged.
Fuse may have blown.
Battery in Remote controller may
have been exhausted.
The time you have set with timer is incorrect.
Wait for power to be restored.
Check that plug is securely in wall
receptacle.
Replace the fuse.
Replace the battery.
Wait or cancel timer setting.
Set temperature correctly. For
detailed method please refer to
""Using remote control section.
Clean the air filter.
Close the doors or windows.
Clear obstructions away first, then
restart the unit.
Wait.
Inappropriate temperature
setting.
Air filter is blocked.
Doors or Windows are open.
Air inlet or outlet of indoor or
outdoor unit has been blocked.
Compressor 3 minutes
protection has been activated.
If the trouble has not been corrected, please contact a local dealer or the nearest customer
service center. Be sure to inform them of the detailed malfunctions and unit model.
Notes: Do not attempt to repair the unit yourself.
Always consult an authorised service provider.
What should be done?
If the following code appears on the LED window, disconnect the power and contact
the service people: E0,E1,E2,E3,E4,E5,E6,E7,E8 or P0,P1,P2,P3,P4.
CS011U-BP9V1
202000100311
Loading...