Midea E90MEW2V71 User Manual

KKKKKKK
COOKER HOOD
INSTRUCT ON MANUALI
Read this manual carefully before operation
Pictures in this manual are for reference only, the product in kind prevail.
MODEL:E90MEW2V71
Contents
Contents
01 02
03 04
05 06 07
08
09
Contents.................................................................
Safety Warning.......................................................3
Notice of Installation...............................................4
Use...................................................................
Maintenance......................................................... 10
Trouble Shooting.................................................. 11
Main Parameters..................................................
Disposal................................................................
12
12
1
7
1
Warnings
This appliance can be used by children aged from 8
z
years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. There shall be adequate ventilation of the room when
z
the range hood is used at the same time as appliances burning gas or other fuels.
The filter is made of high density aluminum.
z z
Please do not use corrosive detergent for cleaning. The proper function of the unit is conditioned by the regularity of the maintenance.
To protect the main body from corrosive of the long time
z
accumulation of dirt, the cooker hood should be cleaned with hot water with non-corrosive detergent every two months.
There is a fire risk if cleaning is not carried out in
z
accordance with the instructions.
Do not flame under the range hood.
z z
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or
other fuels.
The minimum distance between the supporting surface
z
for the cooking vessels on the hob and the lowest part of the range hood is 650 mm. Regulations concerning the discharge of air have to be
z
fulfilled.
The appliance uses 4 hob elements at most.
z z
CAUTION : used with cooking appliances.
Accessible parts may become hot when
2
Safety Warning
The appliance is not intended for use by young children or infirm
persons without supervisions.
Young children should be supervised to ensure they do not play with
the appliance.
Plug the power cord to socket outlet with earthing continuity terminal.
The cooker hood is for home use only, not suitable for barbecue, roast
shop and other commercial purposes.
The cooker hood and its filter should be cleaned regularly
according to the instruction.
Do not use open flame, or allow oil to go beneath the appliance.
If there is any fault occurred with the appliance, please call after-sale
service department.
Please keep the kitchen room ventilated.
Prior to any maintenance, cleaning operation, ensure the power is cut
off.
If the supply cord is damaged, it must be replaced by the manufacturer,
service agent or similarly qualified person in order to avoid a hazard.
The replaced power cord should be provided by manufacturer or seller.
If the plug or cord is damaged, please call after-sale service center.
There is a fire risk if cleaning is not carried out in accordance with the
instruction.
In case of damaged connecting wire, please refer to the manufacturer,
after-sale service personnel or other qualified technicians.
Use the unit according to the instructions to avoid any fire hazard.
The exhaust air must not be introduced into a smoke flue or chimney
that is used for exhausting fumes from appliances burning gas.
Follow the local laws applicable for external air evacuation.
3
Notice of Installation
It can not share the same air ventilation tube with other appliance
such as gas tube, warmer tube, and hot wind tube. There will be
hazard of underpressure, combustion impaired and harmful gases
drawn back.
The bending of ventilation tube should be ≥120°,parallel or above the
start point/should be connected to the external wall.
placed horizontally to avoid
Please make sure the installation plate is
grease collection at one end. See Fig.1.
Right Wrong
After installation, make sure that plug can be pulled out if necessary.
ed 650~750 mm up from the
T he cooker hood should be plac
cooking plane for safe and a good effect. See Fig.2.
Fig.1
There shall be adequate ventilation of the room when the cooker
hood is working.
4