Midea D30-15FA2, D50-15FA2, D80-15FA2, D100-15FA2 Instruction Manual

Storage Electric Water Heater
Instruction Manual
Model: D30-15FA2 D50-15FA2 D80-15FA2
D100-15FA2
The diagram above is just for reference. Please take the
appearance of the actual product as the standard.
Thank you very much for purchasing our water heater. Before installing and operating your water heater, please read this manual carefully and keep it for future reference.
General Remark
The installation and maintenance has to be carried out by qualified professials or Midea authorized technicians.
The manufacturer shall not be held responsible for any damage or malfunction caused by wrong installation or failing to comply with following instructions included in this pamphlet.
For more detailed installation and maintenance guidelines, please refer to below chapters.
TABLE OF CONTENTS
TITLE PAGE
1.CAUTIONS.......................................................................................................................(2)
2.PRODUCT INTRODUCTION ........................................................................................... (3)
3.UNIT INSTALLATION.......................................................................................................(5)
4.METHODS OF USING ..................................................................................................... (7)
5.MAINTENANCE ...............................................................................................................(7)
6.TROUBLESHOOTING .....................................................................................................(8)
7.PRODUCE INFORMATION WITH EU REGULATION ..................................................... (9)
1
1. CAUTIONS
Before installing this water heater,check and confirm that the earthing on the supply socket is reliably grounded. Otherwise, the electrical water heater can not be installed and used. Do not use extension boards. Incorrect installation and use of this electrical water heater may result in serious injuries and loss of property.
Special Cautions
The supply socket must be earthed reliably. The rated current of the socket shall not be lower than 10A. The socket and plug shall be kept dry to prevent electrical leakage. Inspect frequently whether the plugs contact well with the socket. Inspect method is as follows: insert the power supply plug into socket, after using for half an hour, shut down the unit and pull the plug out, and inspect the plug whether it scalds hand. If it scalds (over 50), please change another well-contacted socket to avoid the plug being damaged, fire or other personnel accidents result from bad-contacting.
The installation height of the supply socket shall not be lower than 1.8m.
The wall in which the electrical water heater is installed shall be able to bear the load more than two times of the heater filled fully with water without distortion and cracks. Otherwise, other strengthening measures shall be adopted.
The pressure relief valve attached with the heater must be installed at the cold water inlet of this heater(see Fig.1), and make sure it is not exposed in the foggy. The water may be outflowed from pressure relief valve, so the outflow pipe must open wide in the air; The pressure relief valve need to be checked and cleaned regularly, so as to make sure it will not be blocked.
Thread screw
Drain handle
Pressure relief valve
Hot water
●●When using the heater for the first time(or the first use after maintenance), the heater can not
be switched on until it has been filled fully with water. When filling the water, at least one of the outlet valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after the heater has been filled fully with water. The water heater is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the heater.
Cold water
Pressure release hole
(Fig.1)
2
During heating, there may be drops of water dripping from the pressure release hole of the multifunction valves. This is a normal phenomenon. If there is a large amount of water leak, please contact customer care center for repair. This pressure release hole shall, under no circumstances, be blocked; otherwise, the heater may be damaged, even resulting in accidents.
The drainage pipe connected to the pressure release hole must be kept sloping downwards.
Since the water temperature inside the heater can reach up to 75°C, the hot water must not be exposed to human bodies when it is initially used. Adjust the water temperature to a suitable temperature to avoid scalding.
Unscrew the thread screw on the multifunction safety valve, and lift the drain handle upwards. (See Fig.1) to drain the water from the inner tank.
If the flexible power supply cord is damaged, the special supply cord provided by the manufacturer must be selected, and replaced by the professional maintenance personnel.
If any parts and components of this electrical water heater are damaged please contact customer care center for repair.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
2. PRODUCT INTRODUCTION
2.1 Technical Performance Parameters
Model
D30-15FA2
Volume
(L)
28
Rated Power
(W)
Rated
Voltage
(ACV)
Rated
Pressure
(MPa)
D50-15FA2 D80-15FA2 D100-15FA2
2.2 Brief introduction of product structure
A
Inner tank
Thermal insulation
Heating element
Power cord
B
Anode
Hot water outlet
Heating indicator light
C
Cold water inlet
Max Of Water
Temperature
Shell
Thermometer
(°C)
Protection
Class
I I I I
D
Water Proof Class
IPX4750.8220-2401500 IPX4750.8220-240150047 IPX4750.8220-240150074 IPX4750.8220-240150093
3
D30-15FA2
A
B C D
2.3 Internal Wire Diagram
340
570 100 200
D50-15FA2
385
705 100 200
D80-15FA2
450
758 100 200
(Note:All dimensions are in mm)
D100-15FA2
450
908 100 200
Thermal Cut Out
Brown
Blue
Yellow/Green
Thermostat
1
2
WIRING DIAGRAM
Heating Element
Heating Indicator Light
4
3. UNIT INSTALLATION
3.1 Installation Instruction
This electrical water heater shall be installed on a solid wall. If the strength of the wall cannot
bear the load equal to two times of the total weight of the heater filled fully with water, it is then necessary to install a special support. Incase of hollow bricks wall, ensure to fill it with cement concrete completely. After selecting a proper location, determine the positions of the two install holes used for
expansion bolts with hook (determined according to the specification of the product you select). Make two holes in the wall with the corresponding depth by using a chopping bit with the size matching the expansion bolts attached with the machine, insert the screws, make the hook upwards, tighten the nuts to fix firmly, and then hang the electric water heater on it (see Fig.2).
Expansion bolt (with hook)
Install the supply socket in the wall. The requirements for the socket are as follows: 250V/10A,
single phase, three electrodes. It is recommended to placed the socket on the right above the heater. The height of the socket to the ground shall not be less than 1.8m (see Fig.3). If there is fault on power cable, it should be replaced by the manufacturers, agencies or qualified person who is able to do this so as to ensure the safety.
L (Brown)
E (Yellow/Green)
(Fig.2)
≥1.8m
N (Blue)
Ground
If the bathroom is too small, the heater can be installed at another place without sun-scorched and
rain-drenched. However, in order to reduce the pipeline heat losses, the installation position of the heater shall be closed to the location shall be as near as possible to the heater.
3.2 Pipelines Connection
The dimension of each pipe part is G1/2” ; The massive pressure of inlet should use Pa as
the unit; The minimum pressure of inlet should use Pa as the unit.
Connection of pressure relief valve with the heater on the inlet of the water heater.
In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided
with the heater must be added at the end of the threads to ensure leak proof joints (see Fig.4).
5
(Fig.3)
Hot water outlet
Adjusting handle for mixing valve
Hot water
If the users want to realize a multi-way supply system, refer to the method shown in fig.5 for connection of the pipelines.
Triple joint
Hot water outlet
Cold water inlet
Cold water inlet
Pressure relief valve
Pressure release hole
Joint screw for cold water inlet
Pressure relief valve
Water inlet valve
Shower nozzle
Water inlet valve
(Fig.4)
Water pool
Mixing valve
Running water pipe
NOTE
Please be sure to use the accessories provided by our company to install this electric water heater. This electric water heater can not be hung on the support until it has been confirmed to be firm and reliable. Otherwise, the electric water heater may drop off from the wall, resulting in damage of the heater, even serious accidents of injury. When determining the locations of the bolt holes, it shall be ensured that there is a clearance not less than 0.2m on the right side of the electric heater, to convenient the maintenance of the heater, if necessary.
6
(Fig.5)
4. METHODS OF USING
First, open any one of the outlet valves at the outlet of the water heater, then, open the inlet valve. The water heater gets filled with water. When water flows out of the outlet pipe it implies that the heater has been filled fully with water, and the outlet valve can be closed.
NOTE
During normal operation, the inlet valve shall be always kept open.
Insert the supply plug into the supply socket, the two indicator lights will light up this time.
The thermostat will automatically control the temperature. When the water temperature inside the heater has reached the set temperature, it will switch off automatically, when the water temperature falls below the set point the heater will be turned on automatically to restore the heating.
5. MAINTENANCE
5. MAINTENANCE
!
!
Do cut off power supply before maintenance, to avoid danger like electric shock.
Do cut off power supply before maintenance, to avoid danger like electric shock.
Temperature limiter cut off electricty if water heater is overheated or thermostat damages. Manual resetting is needed. Ressetting knob is as follows (see Fig.6). Non-professionals are not allowed to disassemble temperature limiter to reset . Please contact prefessionals to maintain. Otherwise our company will not take responsiblity if any quality accident happens because of this.
WARNING
WARNING
Manual reset button
(Fig.6)
(Fig.6)
Check the power plug and outlet as often as possible. Secure electrical contact and also proper grounding must be provided. The plug and outlet must not heat excessively.
If the heater is not used for a long time, especially in regions with low air temperature(below 0°C), it is nessary to drain water from the heater to prevent damage of the water heater, due to water freezing in the internal tank.(Refer Cautions in this manual for the method to drain away the water from the inner container).
To ensure long reliable water heater operation, it is recommended to regularly clean the internal tank and remove deposits on the electric heating element of the water heater, as well as check condition (fully decomposed or not) of the magnesium anode and, if necessary, replace it with a new one in case of full decomposition.Tank cleaning frequency depends on hardness of water located in this territory. Cleaning must be performed by special maintenance services. You can ask the seller for address of the nearest service center.
7
6. TROUBLESHOOTING
Failures Reasons Treatment
The heating indicator light is off.
No water coming out of the hot water outlet.
The water temperature is too high.
Water leak.
Failures of the temperature controller.
1. The running water supply is cut off.
2. The hydraulic pressure is too low.
3. The inlet valve of running water is not open.
Failures of the temperature control system.
Seal problem of the joint of each pipe.
Contact with the professional personnel for repair.
1. Wait for restoration of running water supply.
2. Use the heater again when the hydraulic pressure is increased.
3. Open the inlet valve of running water.
Contact with the professional personnel for repair.
Seal up the joints.
NOTE
Parts illustrated in this use and care manual are indicative only, parts provided with the product may differ with illustrations.This product is intended for household use only. Specifications are subject to change without notice.
8
Loading...
+ 19 hidden pages