Midea 9000 Btu, 12000 Btu, 24000 Btu, 18000 Btu User Manual

Split Type Room Air Conditioner
For trouble free services please register with our Customer Care on 180030000011
or write to us at : mideacare@carriermidea.com
11D Series-Fixed Speed/Inverter
13
10
16
18
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Meanings of symbols used in this manual are as shown below.
WARNING
Always do this.
Never do this.
CAUTION
This symbol indicates the possibility of injury or damage to property.
Connect with the power properly.
Do not modify power cord length or share the outlet with other appliances
Always ensure effective grounding.
Disconnect the power if strange sounds, smell, or smoke comes from it.
Ventilate room before operating air conditioner if there is a gas leakage from another appliance.
Otherwise, it may cause electric shock or fire due to excess heat generation.
It may cause electric shock or fire due to heat generation.
No grounding may cause electric shock.
It may cause fire and electric shock.
It may cause explosion, fire and burns.
It may cause electric shock or fire due to heat generation.
It may cause electric shock.
It may cause failure of machine or electric shock.
It contains contaminants and could make you sick.
It may cause fire and electric shock.
It may cause electric shock or fire.
This could damage your health.
No installation may cause fire and electric shock.
It may cause electric shock.
It may cause explosion or fire.
It may cause failure and electric shock.
Do not operate or stop the unit by switching on or off the power.
Do not operate with wet hands or in damp environment.
Do not allow water to run into electric parts.
Do not drink water drained from air conditioner.
Do not use the power cord close to heating appliances.
Do not damage or use an unspecified power cord.
Do not direct airflow at room occupants only.
Always install circuit breaker and a dedicated power circuit.
Do not open the unit during operation.
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
Do not disassemble or modify unit.
!
!
!
!
!
WARNING
Use the correctly rated breaker or fuse.
There is risk of fire or electric shock.
!
1
44SAFETY PRECAUTIONS
CAUTION
When the air filter is to be removed, do not touch the metal parts of the unit.
It may cause an injury.
Do not clean unit when power is on as it may cause fire, electric shock or injury.
Operation with windows opened may cause wetting of indoor and soaking of household furniture.
When the unit is to be cleaned, switch off, and turn off the circuit breaker.
Stop operation and close the window in storm or hurricane.
Use caution when unpacking and installing. Sharp edges could cause injury.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
This could injure the pet or plant.
Do not put a pet or house plant where it will be exposed to direct air flow.
Ventilate the room well when used together with a stove, etc.
An oxygen shortage may occur.
Do not use this air condĀ­itioner to preserve preciĀ­sion devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
It may cause failure of product or fire.
Do not use for special purposes.
Turn off the main power switch when not using the unit for a long time.
If water enters the unit, turn the unit off and disconnect the power , contact a qualified service technician.
!
!
!
!
!
It may cause failure of appliance or accident.
Appearance may be deteriorated due to change of product color or scratching of its surface.
Do not place obstacles around air-inlets or inside of air-outlet.
Do not use strong detergent such as wax or thinner. Use a soft cloth for cleaning.
If bracket is damaged, there is concern of damage due to falling of unit.
There is danger of fire or electric shock.
Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
Do not place heavy object on the power cord and take care so that the cord is not compressed.
Operation without filters may cause failure.
Always insert the filters securely. Clean filter once every two weeks.
!
!
!
Do not clean the air conditioner with water.
Do not put objects like thin rods into the panel of blower and suction side.
The high-speed fan inside may cause danger.
2
OPERATING INSTRUCTIONS
8. Connecting pipe
9. Connecting cable
10. Stop valve
Outdoor unit
NOTE: The actual shape of the indoor unit you purchased may be slight different on front panel and display window.
NOTE:
All the pictures in this manual are for explanation purposes only. Your air conditioner may be slightly different. The actual shape shall prevail.
Air inlet(
rear)
Air inlet
(side)
Air outlet
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grille
6. Vertical air flow louver(inside)
7. Display panel
Indoor unit
VLED Display Window
RUN indication lamp
This lamp illuminates when the air conditioner is in operation.
TIMER indication lamp
Lights up during Timer operation.
ION indication lamp(optional)
Lights up when Clean Air feature is activated.
DEFROST i
ndication lamp
(Enabled on cooling & heating models only):
Lights up when the air conditioner starts
defrosting automatically or when the warm air control feature is activated in heating operation.
4
3
5
2
6
1
9
10
8
7
Model Name And Dimensions
MODEL
WIDTH (mm)
HEIGHT (mm) DEPTH (mm)
9000 Btu
12000 Btu
18000 Btu
255
255
275
180
188
198
680
770
905
24000 Btu
1030
315
220
ion defrost run timer
(A) Display for D-3 Models
(B) Display for D-1 Models
(C) Display for D-6 Models
Signal Receiver
Signal Receiver
defrost run timer
3
OPERATING INSTRUCTIONS
Special functions
Improving the quality of indoor air is one of the purposes of an air conditioner. This air conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specific configuration of the model). With the anions generated by Ionizer, the air circulation of the air conditioner fills the room with refreshing, natural and healthy air. The Plasma Dust Collector generates a high voltage ionization zone, through which the air is converted to plasma. Inside the air most of the dust, smoke, and pollen particles are captured by the electrostatic filter.
CLEAN AIR function(on some models)
Function used after the shut down of cooling operation to clean the Evaporator ,it keeps the air fresh for the next operation. For cooling models, the unit will operate under FAN ONLY mode at LOW fan speed for half an hour, and then turn off automatically. For cooling & heating models, the unit will operate as in the below sequence : FAN ONLY mode at Low fan speed--Heating operation with LOW fan speed
---FAN ONLY operation--Stop Operation---Turn off.
Note:
This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode. Before selecting the function, it is recommended to run the air conditioner under
all TIMER setting will be cancelled. During SELF CLEAN operation, when pressing the SELF CLEAN button on the remote controller again,the unit will stop the operation and turn off the unit automatically.
Refrigerant Leakage Detection
With this new technology, the dipsplay area will appear EC (if applicable) and the LED indication lamps continue flashing when the outdoor unit detects refrigerant leakage.
When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue operating for about 7-10 minutes (depending on models) with soft wind.This will help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew. Under Anti-mildew operation, do not restart the air conditioner until the unit iscompletely off.
,
,
Within the scope of safety angle, it will memorize the open angle of horizontal louver. If it exceeds, it will memorize the boundry of safety angle. In the following circumstances, it will return to standard angle: 1) pressing the turbo or manual control button, 2)unplug and then plug in the machine.
So we strongly suggest that the open angle of the horizontal louver should not be set too small, in case the condensed water forms and drops from the horizontal louver.
4
cooling operation for about half an hour. Once the Self Clean function is activated,
(Optional):
Louver Angle Memory Function
SELF CLEAN function
(Optional):
(Optional):
Anti-mildew function
Manual operation can be used temporarily in case the remote controller is disable or the unit requires maintenance.
OPERATING INSTRUCTIONS
Manual operation
NOTE: This manual does not include Remote Controller Operations, see the <<Remote Controller Instruction>> packed with the unit for details.
Operating temperature
Open and lift the front panel up to an angle until it remains fixed with a clicking sound. For 24K Btu model, please use suspension bars to prop up the panel. Once you push the manual button, the operation mode is shifted in an order as: AUTO, COOL, OFF. (The default setting temperature is 24 Close the panel firmly to its original position.
This is used for testing purposes only. To restore the remote controller operation, use the remote controller directly.
CAUTION:
1
3
2
Manual control button
AUTO/COOL
Suspension bars
AUTO/COOL
1
2
Manual control button
Mode
Cooling operation
Heating operation
Drying operation
Temperature
1. Optimum performance will be achieved within these operating temperatures.If air conditioner is used outside of the above conditions, certain safety protection features might come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
Room temperature
Outdoor temperature
NOTE:
17 32
62 90
0 30
32 86
-7 24
20 76
18 43
64 109
-7 43 20 109
( For the models with low
temperature cooling system
18 52 64 126
(For special tropical models)
10 32 50 90
(For special tropical models)
11 43 52 109
18 52 64 126
5