Middleby Marshall Oven PS636-1 Installation Manual

PS636 Series Gas Domestic & Std Export ENGLISH
P/N 66639
PS636 Series Gas Ovens
Model:
PS636G Gas
Combinations:
Single Oven
Double Oven (Two-Stack)
Triple Oven (Three-Stack)
OWNER'S OPERATING AND INSTALLATION MANUAL
for domestic and standard export ovens
©2014 Middleby Marshall Inc.
is a registered trademark of Middleby Marshall, Inc. All rights reserved.
Middleby Cooking Systems Group • 1400 Toastmaster Drive • Elgin, IL 60120 • (847)741-3300 • FAX (847)741-4406
I. OVEN SPECIFICATIONS
Table 1-1 Dimensions Single Oven Double Oven Triple Oven
Overall Height 44 (1118mm) 62-3/8” (1635mm) 69-3/4 (1171mm) Overall Depth 44-1/2 (1130mm) 44-1/2” (1130mm) 44-1/2” (1130mm) Overall Length (w/o exit trays) 65-3/4 (1670mm) 65-3/4 (1670mm) 65-3/4 (1670mm) Conveyor Width – belt width is 24 25-1/2 (648mm) 25-1/2 (648mm) 25-1/2 (648mm)
or 2 x 11” (279mm) or 2 x 11” (279mm) or 2 x 11” (279mm)
Recommended Minimum Clearances
Rear of Oven to Wall 0 (0mm) 0 (0mm) 0 (0mm) Control end of conveyor to Wall 2 (50.8mm) 2 (50.8mm) 2 (50.8mm) Non-control end of conveyor to Wall) 2 (50.8mm) 2 (50.8mm) 2 (50.8mm)
Table 1-2: General Specications PS636 GAS 24 Belt
Weight 734 lbs. (333kg)
Rated Heat Input 75,000 BTU (18,892kcal, 22 kW/hr)
Maximum Operation Temperature 600°F / 315°C
Air Blowers Four Blowers at 3400 RPM (max)
Warmup Time 15 min.
Table 1-3: Electrical specications for PS363G gas ovens
Main Blower Control Circuit Phase Freq Current Poles Wires Voltage Voltage Draw
208-240VAC 208-240VAC 1Ph 50/60Hz 4-3 Amp 2 Pole 3 Wire (2 hot, 1 gd)
Table 1-4: Gas orice and pressure specications for PS636G gas ovens
Gas Main Orice I.D. Supply (Inlet) Orice (Manifold) Bypass Type PS745G Pressure Pressure Pressure
Natural 0.094 (2.375120mm) 8-12 W.C. (19.9 - 29.9mbar) 3.5 W.C. (8.7mbar) 0.3-0.35 W.C. (0.8-0.9 mbar)
Propane 0.057″ (1.45mm) 11-14″ W.C. (27.4 - 34.9mbar) 10.0″ W.C. (24.9mbar) 0.9-1.0″ W.C. (2.2-2.5 mbar)
IMPORTANT – Additional electrical information is provided on the oven’s serial plate, and on the wiring diagram inside the machinery compartment.
GAS ORIFICE AND PRESSURE SPECIFICATIONS (PER OVEN CAVITY) - CE OVENS
AT,BG,CR CZ,DK,EE FI,GR,HR FI,CR,GR BG,CY,CR BE,CY,CZ HU,IS,IE IE,HR,LU CZ,DK,EE EE,FR IT,LV,LT NL,PL,SK SW,CH FI,GR,HR GR,IE,IT NO,PT,RO SI,ES,CH AT,DK LV,LT,LU PL LT,LU,LV SK,SI,ES DE TR,GB,CY CY,CZ NO,FI MT,NL,NO AT,DE PT,RO,SK Main SE,CH,TR LU BE CZ,DE,MT DE,MT NI,CR SK,SI,SE HU,SK ES,CH Orice Rated Gas Orice GB NL PL FR SK SK FR TR CH GB,PL (Manifold) Heat
Type dia.
I2H
I
2L
I2E
I
2E+
I
3P
I
I
3P
3B/P
I
3B/P
I
3B/P
I3+ Pressure Input
G20 .0935 20 -- 20 20 -- -- -- -- -- -- 3.5” w.c. 22kW Natural (2.375 mm) mbar mbar mbar 8.7mbar
G25 .0935 -- 25 -- -- -- -- -- -- -- 3.5” w.c. 22kW Natural (2.375 mm) mbar -- 8.7mbar .
G30 .057 -- -- -- -- -- -- 28-30/50 30 37/50 28-30 10.0” w.c. 24.6kW Butane (1.45 mm) mbar mbar mbar mbar 24.9mbar
G31 .057 -- -- -- -- 37 50 30 37/50 37 10.0” w.c. 22kW Propane (1.45 mm) mbar mbar -- mbar mbar mbar 24.9mbar
NOTE
Wiring Diagrams are contained in Section 5 of this Manual
and are also located inside the oven at the
bottom of the Control Panel.
Additional electrical information is provided on the oven's serial plate.
This Manual Must Be Kept For Future Reference
2
SECTION 2 – INSTALLATION
WARNING – After any conversions, readjustments, or service work on the oven:
• Perform a gas leak test. • Test for proper combustion and gas supply.
• Test for correct air supply, particularly to the • Check that the ventilation system is in operation. burner blower.
WARNING - Keep the appliance area free and clear of combustibles.
WARNING – The oven must be installed on an even (level) non-ammable ooring and any adjacent walls must be non-ammable. Recommended minimum clearances are specied in the Description
section of this manual.
WARNING – Do not obstruct the ow of combustion and ventilation air to and from your oven. There
must be no obstructions around or underneath the oven. Constructional changes to the area where the oven is installed shall not affect the air supply to the oven.
CAUTION: To reduce the risk of re, the appliance is to be mounted on oors of noncombustible construction
with noncombustible ooring and surface nish and with no combustible material against the underside there­of, or on noncombustible slabs or arches having no combustible material against the underside thereof, such construction shall in all cases extend not less than 12 inches (304mm) beyond the equipment on all sides.
CAUTION: For additional installation information, contact your local Authorized Service Agent.
NOTE – There must be adequate clearance between the oven and combustible construction. Clearance must also be provided for servicing and for proper operation.
NOTE – An electrical wiring diagram for the oven is located inside the machinery compartment.
NOTE: All aspects of the oven installation, including placement, utility connections, and ventilation require-
ments, must conform with any applicable local, national, or international codes. These codes supersede the requirements and guidelines provided in this manual.
NOTE: In the USA, the oven installation must conform to local codes. In the absence of local codes, gas oven installations must conform with the National Fuel Gas Code, ANSI Z223.1. Gas and electric ovens, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code (NEC), or ANSI/NFPA70.
NOTE: In Canada, the oven installation must conform with local codes. In the absence of local codes, gas oven installations must conform with the Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Gas Installation Code, CAN/CGA-B149.2, as applicable. Gas and electric ovens, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the Canadian Electrical Code CSA C22.2.
NOTE: In Australia, the oven installation must conform with local codes. In the absence of local codes, gas oven installations must conform with the requirements of AS5601/AG601, Gas, Electricity, and any other relevant statutory regulations.
3
PS636 24” OVEN INSTALLATION
REQUIRED KITS AND EQUIPMENT
PS636
Gas Oven
Type Of Installation
PS636 Single Gas Oven 66331 1
PS636 Double Gas Oven 66332 1
PS636 Triple Gas Oven 66333 1
Installation
Kit
PS636
Single Oven
Option Base w/
15” Legs,
Casters & Top
Kit
P/N 66129
PS636
Double Oven
Option Base w/
15” Legs,
Casters & Top
Kit
P/N 66027
PS636
Triple Oven
Option Base w/
15” Legs,
Casters & Top
P/N 6xxxx
Kit
III. VENTILATION SYSTEM
IMPORTANT
Where national or local codes re-
pression equipment or other
supplementary equipment, DO NOT
mount the
equipment directly to the oven.
B. Recommendations
NOTE THAT THE HOOD DIMENSIONS SHOWN IN FIGURE 2-5 ARE RECOMMENDATIONS ONLY. LOCAL, NATIONAL AND INTERNATIONAL CODES MUST BE FOLLOWED WHEN INSTALLING THE VENTILATION SYSTEM. ANY APPLICABLE CODES
-
SUPERSEDE THE RECOMMENDATIONS SHOWN IN THIS MANUAL. IN AUSTRALIA COMPLIANCE TO REGU­LATIONS AS5601/AG601 IS MANDATORY.
-
sign. Consult the hood manufacturer or ventilation engineer
MOUNTING SUCH EQUIPMENT ON
THE OVEN MAY:
• VOID AGENCY CERTIFICATIONS
• RESTRICT SERVICE ACCESS
• LEAD TO INCREASED SERVICE EXPENSES FOR THE OWNER
A. Requirements
CAUTION: Gas oven installations REQUIRE a mechani-
cally driven ventilation system with electrical exhaust air sensing control.
A mechanically driven ventilation system is STRONGLY RECOMMENDED for electric oven installations.
PROPER VENTILATION OF THE OVEN IS THE RE­SPONSIBILITY OF THE OWNER.
Figure 2-5. Ventilation System
6 (152mm)
minimum
(Typical - both
ends of oven)
2 (51mm)
minimum
To avoid a negative pressure condition in the kitchen area, return air must be brought back to replenish the air that was exhausted. A negative pressure in the kitchen can cause heat- related problems to the oven components as if there were no ventilation at all. The best method of supplying return air is through the heating, ventilation and air condition­ing (HVAC) system. Through the HVAC system, the air can be temperature-controlled for summer and winter. Return air can also be brought in directly from outside the building, but detrimental effects can result from extreme seasonal hot and cold temperatures from the outdoors.
NOTE: Return air from the mechanically driven system
must not blow at the opening of the baking chamber. Poor oven baking performance will result.
C. Other ventilation concerns
Special locations, conditions, or problems may require the services of a ventilation engineer or specialist.
Inadequate ventilation can inhibit oven performance.
It is recommended that the ventilation system and duct
hood manufacturer and/or HVAC engineer or specialist.
2 (51mm)
minimum
3 (76mm)
minimum
5