GAS SUPPLY PROVIDED BY CUSTOMER
Min. Gas Pipe Size Gas Valves (full flow gas shut-off valve) Req'd Supply Gas Pressure Power
Natural Gas 1 or 2 ovens 2" (508) NPT .75" (19.05) ID each oven 6" (152.4) to 14" (355.6) water column 135,000 BTU/HR per cavity
Propane Gas 1 or 2 ovens 1.5" (38.1) NPT .75" (19.05) ID each oven 11.5" (292.1) to 14" (355.6) water column 135,000 BTU/HR per cavity
GENERAL INFORMATION
Heating Bake Belt Max. Bake Ship Ship
Zone Chamber Width Height Width Depth Operating Time Wt. Cube
Temp. Range (lbs.) Per Cavity
PS314 Single
54.5" 9.08 sq.ft. 24" 45.5" 70.75" 39" 550° 2 min., 40 sec.
1100 104.5 ft.
3
(1384.3) (.8435 sq.m) (609.6) (114.3) (1797.05) (990.6) (287°C) to 29 min., 50 sec.
PS314 Double
109" 18.17 sq. ft. 24" 82" 70.75" 39" 550° 2 min.,40 sec.
2200 104.5 ft.
3
(2768.6) (1.687 sq.m) (609.6) (2082.8) (1797.05) (990.6) (287°C) to 29 min., 50 sec.
RECOMMENDED MINIMUM CLEARANCES
Rear of Oven Left Conveyor Right Conveyor Extension
to Wall Extension to Wall to Wall (control panel side)
1" (25.4) 0" 0"
Middleby Marshall
Model PS314
Direct Gas Fired
Conveyor Oven
Baking chamber opening: 3.875" (98.425 mm).
Scale .25" (6.35 mm) = 1’ (304.8 mm) approx.
NOTE: All Figures In Parentheses Are In Millimeters
*
Above specifications subject to change without notice.
2"
(50.8)
32"
(812.8)
37"
(939.8)
34"
(863.6)
24"
(609.6)
Cooking
Zone
70.75"
(1797.05)
54.5"
(1384.3)
45.5"
(1130.3)
31.5"
(800.1)
6.5"
(165.1)
34"
(863.6)
27.25"
(692.15)
10.125"
(257.175)
11.5"
(292.1)
5.843"
(148.412)
16.5"
(419.1)
5.843"
(148.412)
6.25"
(158.75)
11.5"
(292.1)
10.125"
(251.175)
27.25"
(692.15)
11.5"
(292.1)
16.5"
(419.1)
34"
(863.6)
5.25"
(133.35)
70.75"
(1797.05)
54.5"
(1384.3)
11"
(279.4)
27.25"
(692.15)
82"
(2082.8)
52.5"
(1333.5)
31.5"
(800.1)
6.5"
(165.1)
Top View of Both The
PS314 Single and
PS314 Double Unit
PS314
Front View
Side View
Rear View
PS314D
Front View
Side View
Rear View
1400 Toastmaster Drive, Elgin, IL 60120-9272 USA • (847) 741-3300 • Fax: (847) 741-0015
www.middleby.com
Printed in U.S.A. 9/00 Form 4311
Gas Fired Ovens Voltage Phase HZ Amps Supply Breakers
PS314 208 - 240 1 60 10 3 pole, 4 wire per local codes
(2 hot, 1 neutral,1 ground)
ELECTRICAL RATINGS