Select Series UPS
backup power systems
- 4 models available
- 1 and 2 RU sizes
- 2200, 1500, 1000 and 500VA options
- Bank control of outlets for simple system reboot
- Simulated sine wave output waveform
features:
- Remote monitoring and control of power with optional IP card
- 8ms transfer time
- Automatic Voltage Regulation
- Non-critical load shedding
- Surge protection and EMI filtering
- LED status indicators
- Battery pack easily replaced via front panel
- UL Listed in the US and Canada
value priced UPS with simulated sine wave
and IP capability
UPS-S500R
Select Series Rackmount Uninterruptible Power Supply ( UPS) shall be Middle Atlantic Products model
# UPS- S__ R (refer to chart). Rackmount UPS shall be AVR with boost only. Rackmount UPS shall
measure 19.00” W x __” H x __” D (refer to chart) and occupy _ (1,2, refer to chart) rackspaces.
Rackmount UPS shall operate on 120 VAC/60Hz current. Rackmount UPS shall have a nominal
output of 120V. Rackmount UPS shall have a capacity of _ _ VA and __ W (refer to chart). Rackmount
UPS shall have _ NEMA 5- __ receptacles on the rear of the unit (refer to chart). Rackmount UPS
shall have a priority outlet bank consisting of _ outlets (refer to chart) dedicated to ensure maximum
run time of critical components. Rackmount UPS shall have a non-critical outlet bank consisting of
_ outlets (refer to chart) dedicated to load shedding. Rackmount UPS shall have a simulated sine
wave output waveform. Rackmount UPS shall have an 8ms transfer time. Rackmount UPS shall be
IP enabled when used with option IP Expansion card, model # UPS-IPCARD. Rackmount UPS shall
include a 10’ __ (refer to chart) power cord with NEMA __ (refer to chart) plug. Rackmount UPS
shall have surge suppression that utilizes a clean line-to-neutral design that does not pass noise
specifications:
contamination to ground. Rackmount UPS shall allow for a __ minute run time at half load and a __
(refer to chart) minute run time at full load. Rackmount UPS shall be RoHS EU Directive 2002/95/ EC
& 2011/65/ EU compliant. Rackmount UPS shall utilize Middle Atlantic Power Manager™ software.
Rackmount UPS shall be warrantied to be free from defects in materials and workmanship under
normal use and conditions for a period of 3 years; battery shall be warrantied for a period of 2 years.
Rackmount UPS shall be UL listed in US and Canada.
Customizable specification clips available at middleatlantic.com
options:
• UPS-IPCARD: Web based control shall be enabled
on non-internet enabled Middle Atlantic Products
UPS by UPS-IPCARD, which shall be installed into
the Expansion Port on the rear of the UPS.
• Replacement Battery: Replacement Battery Pack
for the UPS shall be Middle Atlantic Products model #
UPS Replacement Battery
UPS-S500R UPS-SRBP-500
UPS-S1000R UPS-SRBP-1000
UPS-S1500R UPS-SRBP-1500
UPS-S2200R UPS-SRBP-2200
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca
96-01214 / rev a / 3-2-15

UPS-S Series
basic dimensions
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
17.2 [437]
17.05 [433]
8.68
[221]
D indicators
1.73 [44]
14.94
[380]
power switch
mute button
19.00 [483]
9.06
[230]
15.31
[389]
.59 [15]
UPS-S1000R
IP card expansion port
(order p/n UPS-IPCARD)
3x NEMA5-15R
non-critical load
3x NEMA5-15R
critical load
emergency
power off
USB port
15A circuit breaker
15A power cord
wiring fault indicator LED
ground
LED indicators
73 [44]
19.00 [483]
what great systems are built on.
power switch
mute button
.59 [15]
™
IP card expansion port
(order p/n UPS-IPCARD)
3X NEMA5-15R
non-critical load
3x NEMA5-15R
emergency
power off
USB port
15A circuit breake
15A power cord
wiring fault
indicator LED
ground
middleatlantic.com | middleatlantic.ca
2

UPS-S Series
basic dimensions
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
17.30 [439]
17.06 [433]
14.98
[381]
LED indicators
3.46
[88]
4x critical load
critcal load
circuit breaker
4x non-critical
(see table)
ground
non-critcal load
circuit breaker
(see table)
energency
power off
19.00 [483]
1.63 [41]
.42 [11]
USB
port
power switch
mute button
power cord (see table)
16.50
[419]
IP card expansion port
(order p/n UPS-IPCARD)
main circuit breaker
fan
wiring fault indicator LE
Technical Specifications UPS-S500R UPS-S1000R UPS-S1500R UPS-S2200R
Capacity (Va)
Capacity (Watts) 300 600 900 1320
500 1000 1500 2000
Input
Cord Length And Plug Type 10ft. & NEMA 5-15P 10ft. & NEMA 5-20P
Input Voltage Range 90 VAC - 140 VAC
Input Frequency Range 60Hz #+/-3Hz (auto sensing)
Output
On Battery Output Voltage simulated sine wave at 120 VAC +/-10%
On Battery Output Frequency 60 Hz #+/-1%
AVR boost only (with input voltage less than 100 VAC)
Transfer Time (Typical) 8 ms
Overload Protection on utility: circuit breaker, on battery: internal current limiting
Surge Protection & Filtering single mode, L - N
Lightning/Surge Protection 1030 Joules 1030 Joules 1840 Joules 1840 Joules
Physical
Output Receptacles (6) NEMA 5-15R (8) NEMA 5-15R (8) NEMA 5-20R
Weight Lb. (Kg) 18 (8.2) 32 (15) 48 (21.9) 52.7 (23.9)
Battery
Sealed Maintenance Free
Lead Acid Battery
Full Load Run Time (estimated) 3 minute 3 minute 6 minute 4 minute
Half Load Run Time (estimated) 12 minute 13 minute 18 minute 13 minute
6V / 7.0AH X 2 6V / 7.0AH X 4 12V / 7.0AH X 4 12V / 9.0AH X 4
Warning Diagnostics
Indicators
Audible Alarms on battery, low battery, overload
power on, wiring fault, led display (using battery,
AVR, load level, battery level)
Environmental
Operating Temperature 32F to 104F (0C to 40C)
Operating Relative Humidity 0 to 95% non-condensing
Communication
Power Manager Software (TM) WINDOWS 98/ME/NT/2000/XP/VISTA/WINDOWS 8
Auto-Charger/Auto-Restart yes
Built-In USB Interface yes
Model# Amperage Rating Outlets Power Cord Output
UPS-S1500R
UPS-S2200R
15A
20A
what great systems are built on.
NEMA5-15R
NEMA5-20R
15A
20A
™
1500VA
2000VA
middleatlantic.com | middleatlantic.ca
3