Premium Online Series
UPS backup power systems
• Permanent connection to the battery for zero transfer time eliminating system
disruptions and guaranteeing maximum uptime
• Complete isolation and conditioning of output power with double conversion
topology providing the cleanest power possible
• Reduced ambient noise with quiet variable speed fans
• Longest run time available in this form factor with the capability to add up to
features:
10 expansion battery packs
• Front accessible, hot-swappable batteries to eliminate downtime related to UPS
power maintenance
• Pure sine wave output waveform automatically corrects over-voltage and
under-voltage conditions
• Non-critical load shedding
• EMI/RFI filtering for clean power of connected equipment
• Monitoring and reporting for real time battery life notifications
backup protection with double
conversion that isolates and
conditions output power for clean,
consistent, reliable power
• Removable LCD display & power switch for remote accessible functionality
• Flexibility to set the output frequency to match connected equipment
• Remote monitoring and control of power with optional IP card
Rackmount Online Uninterruptible Power Supply ( UPS) shall be Middle Atlantic Products model
# UPS-OL__ R (refer to chart). Unit shall measure 19.00” W x 3.50” H x __” D and occupy 2
rackspaces. UPS shall have a rear mounting range of 20.69” to 36.19” and not require more than one
person to mount. UPS shall have a minimum usable depth of _ _” (refer to chart). Unit shall operate
on 120 VAC/60Hz. Unit shall have a nominal output of 120V. Unit shall have a capacity of _ _ VA and
__ W (refer to chart). Unit shall have ( _ ) NEMA 5- _ _ receptacles on the rear of the unit (refer to
drawing). Unit shall have a priority outlet bank consisting of _ outlets dedicated to ensure maximum
run time of critical components. Unit shall have a non-critical outlet bank consisting of _ outlets
dedicated to load shedding (refer to drawing). Unit shall be IP enabled when used with optional IP
Expansion card, model # UPS-OLIPCARD. Rackmount UPS shall include a 10’ power cord with NEMA
__ (refer to chart) plug. UPS shall have surge suppression that utilizes a clean line-to-neutral design
that does not pass noise contamination to ground. Rackmount UPS shall have a hot swappable
battery that allows for a _ _ minute run time at half load and a __ (refer to chart) minute run time
specifications:
at full load. Rear of unit shall have inputs that allow for the installation of up to __ additional hot
swappable batteries (refer to chart). Rackmount UPS shall meet the EU RoHS Directive 2011/65/ EU.
Rackmount UPS shall utilize Middle Atlantic Power Manager™ software. Rackmount UPS shall be
warrantied to be free from defects in materials and workmanship under normal use and conditions
for a period of 3 years; battery shall be warrantied for a period of 2 years. Rackmount UPS shall be
UL listed to US and Canadian safety requirements and FCC/IC Class A or B.
Customizable specification clips available at middleatlantic.com
EIA/TIA COMPLIANT
options:
UPS-OLIPCARD
Web based control shall be enabled by the use of optional
UPS-OLIPCARD, which shall be installed into the Expansion
Port on the rear of the UPS.
Expansion Battery
Rackmount expansion battery pack shall be Middle Atlantic
Products model# UPS-OLEBPR__ (refer to chart for model
number and compatibility). Rackmount expansion battery
pack shall be warrantied for a period of 2 years.
Replacement Battery
UPS hot swappable replacement battery pack shall be
Middle Atlantic Products model# UPS-OLRBP-_ (refer to
chart for model number and compatibility). Replacement
battery shall be warrantied for a period of 2 years.
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca
96-01236 / rev a / 6-7-16

Premium Online Series UPS
basic dimensions
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
6.00 [152]
clearance
quired for
cables
17.64 [448]
minimum
useable
depth
A
1.36 [35] face
chassis
depth
B
17.05 [433]
17.92 [455]
rear mounting
range
20.69 [526]
to
36.19 [919]
1.69 [43] handles
Model
Number
UPS-OL1500R 20.69 [526] 15.57 [395] 15 AMP
UPS-OLEBPR-2 20.69 [526] 15.57 [395] 15 AMP
UPS-OL2200R 28.26 [718] 22.26 [565] 20 AMP
UPS-OL3000R 28.26 [718] 22.26 [565] 30 AMP
UPS-OLEBPR-1 28.26 [718] 22.26 [565] 20 AMP
Minimum Useable DepthB Chassis Depth
A
Amperage
Rating
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca
2

Premium Online Series UPS
basic dimensions
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
serial port
relay output
connector
relay output connector
IP card expansion
port (UPS-OLICARD)
USB port
UPS-OL1500R, UPS-OL2200R & UPS-OL-3000R
LCD display
power switch
19.00 [483]
function
buttons
rear view
UPS-0L1500R
surge protected
comm. ports
RJ-45/RJ-11
EPO
(emergency
power off)
connector
USB port
19.00 [483]
expansion
battery connector
(UPS-OLEBPR-2)
AC input
NEMA 5-15P
input circuit
breaker
rear view
UPS-OL2200R
19.00 [483]
input circuit
breaker
3.46 [88]
2RU
IP card expansion port
(UPS-OLIPCARD)
battery backup and
surge protected outlets
4x NEMA 5-15R
non-critical load
4x NEMA 5-15R
battery backup and
surge protected outlets
3X NEMA 5-20R
UPS-OLEBPR-1 & UPS-OLEBPR-2
19.0 [483]
rear view
UPS-OLEBPR-1 & UPS-OLEBPR-2
AC input outlet
(charging only)
on board
replaceable fuse
19.00 [483]
AC circuit
breaker
AC output
outlet
DC circuit
breaker
output
cable
input
connector
3.46
[88]
2ru
serial port
EPO (emergency
ower off connector)
IP card expansion port
(UPS-OLIPCARD)
relay output connector
usb port
serial port
EPO (emergency
power off connector)
expansion battery
connector (UPS-OLEBPR-1)
surge protected comm.
ports RJ-45/RJ-11
AC input circuit breaker
expansion battery
connector (UPS-OLEBPR-1)
surge protected
what great systems are built on.
rear view
UPS-OL3000R
19.00 [483]
™
AC input
NEMA 5-20P
critical load
circuit breaker
non-critical load
NEMA l5-20
non-critical load
3x NEMA 5-20R
non-critical load
circuit breaker
battery backup and
surge protected outlets
3X NEMA 5-20R
non-critical load
NEMA L5-30
non-critical load
3X NEMA 5-20R
middleatlantic.com | middleatlantic.ca
3

all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
UPS SPECS UPS-OL1500R UPS-OL2200R UPS-OL3000R
CONFIGURATION
Capacity (VA) 1500VA 2200VA 3000VA
Capacity (Watts) 1350W 1800W 2700W
INPUT
Cord Length and Plug Type 10ft, NEMA 5-15P 10ft, NEMA 5-20P 10ft, NEMA L5-30P
Input Voltage Range 100~125Vac
Input Frequency Range 50 / 60Hz
Input Power Factor 0.99
Cold Start Yes
OUTPUT
Output Waveform Sine wave
Output Voltage (regulated) 100, 110, 115, 120, 125Vac (Configurable) ±2%
Output Frequency 50 / 60Hz (Auto-Sensing or Configurable) ±0.25Hz
Transfer Time 0ms
Rated Power Factor 0.9 0.82 0.9
Harmonic Distortion THD < 3% at Linear Load, < 5% at Non-linear Load
Crest Factor 3:1
ECO Mode Voltage Regulation ±10%, ±15% (Configurable)
UPS Outlets (8) NEMA 5-15R
PROTECTION
Surge Protection IEC 61000-4-5 Level 3
Phone / Network Protection RJ11/RJ45 (One In/One Out)
Overload Protection
Short Circuit Protection
Specifications (3) 12V/9AH (6) 12V/9AH (6) 12V/9AH
Full Load Runtime (estimated) 4min 7min 4min
Half Load Runtime (estimated) 12min 20min 11min
Recharge Time (Typically) 5 hours for 0-100% Capacity; 4 hours for 0-90% Capacity
Sealed, Maintenance Free Yes
Hot-Swappable Yes
LCD Screen
LED Indicators
Audible Alarms Battery Mode, Battery Low, Overload, UPS Fault
Operating Temperature 32º to 104º F ( 0º to 40º C)
Operating Relative Humidity 0 to 90% Non-Condensing
On-Device Features Self-Test, Auto-Charge, Auto-Restart, Auto-Overload Recovery
Connectivity Ports (1) Serial Port (RS232), (1) USB Port, (1) Relay Out
Expansion Slot
Power Management Software Middle Atlantic Power Manager Software
Net Weight 39.6lbs (18kg) 68.2lbs (31kg)
Conformance Approvals UL and FCC
RoHS RoHS Compliant
Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec
Battery Mode: 105~130% Load for 10 sec, 131~150% Load for 2 sec
UPS Output Cut off Immediately or Input Fuse /
BATTERY
STATUS INDICATORS
Multi-Function LCD Readout that Supports: (19) Types of Read Out,
(22) Types of Function Setting, (5) Event Logs
Power On (White), Line Mode (Green), Battery Mode (Yellow),
Bypass Mode (Yellow), Fault (Red), Replace Battery (Red)
ENVIRONMENT
MANAGEMENT
(1) Expansion Slot for optional remote management cards
SOFTWARE
PHYSICAL
SAFETY
(6) NEMA 5-20R,
(1) L5-20R
Circuit Breaker Protection
(With optional UPS-OLIPCARD)
(6) NEMA 5-20R,
(1) L5-30R
BATTERY SPECS
AC Input Voltage 100~125Vac
DC Output Voltage 36Vdc 72Vdc
Amperage 60A
Net Weight 50.6lbs(23.0Kg) 96.8lbs(44.0Kg)
Specifications Qty 6 (2 x Banks of 3 Batteries) Qty 12 (2 x Banks of 6 Batteries)
Recharge Time (Typically) 5 hours for 0-100% Capacity; 4 hours for 0-90% Capacity
Interface PP45
Sealed, Maintenance Free Yes
Hot-Swappable Yes
Built-in Charger Yes
Operating Temperature 32˚F to 104˚F (0˚C to 40˚C)
Operating Relative Humidity 0 to 90% Non-Condensing
Conformance Approvals UL
RoHS RoHS Compliant
The following table shows Middle Atlantic Products, Inc. online UPS units and their corresponding online
expansion battery packs. Contact technical support at 1-800-266-7225 for more information about Middle
Atlantic Product’s Battery Replacement Program.
MAP UPS or
EBPR Part #
UPS-OL1500R 1500VA UPS UPS-OLEBPR-2 X
UPS-OL2200R 2200VA UPS UPS-OLEBPR-1 X
UPS-OL3000R 3000VA UPS UPS-OLEBPR-1 X
UPS-OLEBPR-1
UPS-OLEBPR-2
Description
2200/3000VA
UPS Expansion
Battery
1500VA UPS
Expansion
Battery
UPS-OLEBPR-2 UPS-OLEBPR-1
CONFIGURATION
PHYSICAL
BATTERY
ENVIRONMENT
SAFETY
Compatible
Expansion Battery
Packs
NA X (2 each)
NA X (Left) X (Right)
UPS-OLRBP-1 UPS-OLRBP-2 UPS-OLRBP-3 UPS-OLRBP-4
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca