Thank you for purchasing the SRSR Series Rotating Sliding Rail System. Please read these
instructions thoroughly before assembling this product.
PRODUCT FEATURES
- Provides easy access to rear equipment connections
- Ideal for millwork, cabinets and flush in-wall installations
- Rack frame removes for in-shop integration and on-site installation
I-00162 Rev E
IMPORTANT SAFETY INSTRUCTIONS
WARNING: A WARNING alerts you to a
!
situation that could result in serious personal
injury or death.
IMPORTANT WARNINGS AND CAUTIONS!
!
WARNING! Failure to read, understand and follow the following information can result in serious
personal injury, damage to the equipment or voiding of the warranty. It is the responsibility of the
Installer/User to ensure that this product is loaded according to specifications.
situation that may result in minor personal
injury or damage to the product
and /or property.
TOOLS REQUIRED
#2 Phillips Head Screwdriver
1/2” Wrench
Drill
Tape Measure
ASSEMBLY
1) Remove two (2) #10-32 rack screws securing
locking trim panel to SRSR base and set
aside. (FIGURE A)
2) Extend the sliding carriage on the SRSR base.
RACK SCREWS #10-32 (2)
Page 3
FIGURE A
LOCKING
TRIM PANEL
ASSEMBLY (CONTINUED)
HEX HEAD
SCREWS
#10-32 x 1/2”
(2 PER SIDE)
CABLE
MANAGEMENT
SUPPORTS (2)
LACER
BAR
3) Install both cable management supports to SRSR
base using one (1) 5/16-18 flange nut and two
(2) #10-32 x 1/2” hex head screws per side.
(FIGURE B)
4) Using provided #10-32 rack screws, install lacer
bars as desired to cable management supports
with flat side facing up and edges on outside
of supports. (FIGURE C)
LACER BAR
RACK SCREWS #10-32 (2 PER BAR)
FIGURE C
FLANGE NUTS
SRSR BASE
5/16”-18
(1 PER SIDE)
FIGURE B
5) Observe rackrail labels for proper orientation and
install front and rear rackrail pairs to rack frame
using two (2) 5/16”-18 flange nuts per rail.
(FIGURE D)
NOTE: Hand-tighten only.
REAR RACKRAIL (2)
FLANGE NUTS
5/16”-18
(2 PER RAIL)
Page 4
RACK FRAME
FRONT RACKRAIL (2)
FIGURE D
ASSEMBLY (CONTINUED)
6) Install squaring panels one third of the way down from top of front and rear rackrail using four (4)
#10-32 rack screws per panel. (FIGURE E)
NOTE: Load equipment before removing squaring panels.
7) SRSR’S WITH 25 SPACES OR MORE:Install front-to-rear braces to rackrails
as shown using two (2) 5/16”-18 flange
nuts per brace. (FIGURE F)
FLANGE NUTS 5/16”-18
(2 PER BRACE)
HANDLES
SQUARING PANEL
FIGURE E
RACK SCREWS
#10-32 (4)
FRONT TO REAR
FIGURE F
BRACES (2)
8) Fully tighten front and rear rackrails to
rack frame.
9) Remove four (4) wing nuts beneath
the sliding carriage to release the
rack frame. (FIGURE G)
10) Lift the rack frame off sliding
carriage using the provided
handles. (FIGURE G)
SLIDING
CARRIAGE
11) Position and center the SRSR
base in millwork to desired setback.
Please refer to Middle Atlantic Products
A & E spec sheet # 96-985 for complete
millwork dimensions. Maximum suggested
functional setback is 2" (more setback
reduces usable depth).
RACK
FRAME
SRSR BASE
WING NUTS (4)
FIGURE G
Page 5
ASSEMBLY (CONTINUED)
12) Extend sliding carriage forward to reveal rear
preliminary mounting hole in SRSR base.
(FIGURE H)
13) Insert fastener (not supplied) through rear
preliminary mounting hole to secure rear of
SRSR base to millwork. (FIGURE H)
REAR PRELIMINARY MOUNTING HOLE
14) Extend sliding carriage further forward to
reveal front preliminary mounting hole in
SRSR base. (FIGURE H)
FRONT
PRELIMINARY
MOUNTING
HOLE
15) Insert fastener (not supplied) through front
preliminary mounting hole to secure front of
SRSR base to millwork. (FIGURE H)
16) Verify setback clearances and complete
attachment of SRSR base to millwork using
mounting points shown on (FIGURE J) on page 7.
17) Verify setback clearances and complete
attachment of SRSR base to millwork using
FIGURE H
mounting points shown on (FIGURE J) on page 7.
!
CAUTION! Failure to install all required hardware may result in damage to the equipment
and possible injury to the user.
18) Place rack frame on sliding carriage using
provided handles. (FIGURE G)
NOTE: Mounting studs on underside
of rack frame must be inserted into
LOCKOUT LEVER
mounting holes in sliding carriage.
19) Re-install the rack frame to the sliding
carriage using four (4) wing nuts.
(FIGURE G)
20) Depress the lockout lever on the front
of the sliding carriage and push the rack
frame into the millwork. (FIGURE I)
21) Retract the sliding carriage on the
SRSR base. (FIGURE G)
22) Replace two (2) #10-32 rack screws (from step #1)
to secure locking trim panel to SRSR base. (FIGURE G)
Page 6
FIGURE I
SRSR MOUNTING POINT LOCATIONS
SRSR-2, SRSR-4
18.125 [460]
17.34 [440]
15.78 [401]
13.97 [355]
.281 dia. [7]
2.78 [71]
1.59 [40]
0.00 [0]
(from trim)
12.125 [308]
*
11.0
[279]
8.0
[203]
*
9.59 [244]
19.19 [487]
FRONT
(12 Additional mounting
holes as shown)
SRSR-X
Preliminary Mounting Holes
*
19.23
[488]
3.78 [96]
FIGURE J
22.34 [567]
18.97 [482]
.281 dia. [7]
15.78 [401]
2.78 [71]
1.59 [40]
0.00 [0]
(from trim)
18.125 [460]
12.125 [308]
*
11.0
[279]
8.0
[203]
*
9.59 [244]
19.19 [487]
FRONT
(12 Additional mounting
holes as shown)
Page 7
3.78 [96]
23.23
[590]
Preliminary Mounting Holes
*
All dimensions in inches [dimensions
in brackets are millimeters]
SRSR ROTATING SLIDING RAIL SYSTEM
To rotate the sliding carriage, pull rotating tab as shown below. (FIGURE K) The sliding carriage
conveniently locks in the 60º and 90º positions for servicing. The the 0º position locks for closure.
ROTATING TAB
FIGURE K
LOCKOUT
LEVER
ROTATE
Page 8
CABLE MANAGEMENT TIPS
• Route cables in the direction of the rack rotation as shown. (FIGURE L)
• Select one side of rack for signal cables, and the opposite side for power cables.
• Lace cables as shown, ensuring cables are fairly taut. This ensures that the service loop
will be the correct length and not be pinched when closing the rack.
FASTEN CABLES USING WIRE TIES
AS SHOWN (HINT - LEAVE LOOSE)
TIE CABLE BUNDLES EVERY
SIX TO EIGHT INCHES. THIS
ALLOWS CABLE BUNDLES
TO LAY NEATLY TOGETHER
WHEN RACK IS IN THE
CLOSED POSITION.
REAR OF SRSR
FASTEN CABLES
APPROXIMATELY
3” FROM END
FIGURE L
ROTATE RACK IN THE DIRECTION OF CABLE ROUTING.
Page 9
INSTALLING OPTIONAL GASKET MODEL # BG17
IMPORTANT NOTE: WHEN USING THE GASKET, THE MINIMUM MILLWORK ROUGH OPENING WIDTH IS 19-5/8"
1) Remove dust and debris from
rack surface with included wipes.
CLEAN ALONG
THESE SURFACES
2) While removing paper backing,
gently pull self-adhesive gasket
from bottom to top of rack.
3) Align and adhere gasket at top of rackrail
and continue across top (if applicable).
Repeat for opposite rackrail.
NOTE: Press firmly along length of gasket.
4) Trim excess length.
HINT: If gasket is needed across the top of the
rack, the top space will require a flanged panel
or a component with a flat top.
GASKET
GASKET
Page 10
ALIGN GASKET
TO EDGE OF
FLAT SURFACE
GASKET (ON SIDES OF RACK
AND TOP OF FLANGED PANEL)
WARRANTY
Middle Atlantic Products (the "Company") warrants the SRSR SERIES ROTATING SLIDING RAIL
SYSTEM to be free from defects in material or workmanship under normal use and conditions for a
period of (3) three years from date of shipment by the Company.
The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and
exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of
and refund of the price paid for, or (b) repair or replacement at the Company's factory of the products
purchased, or any part or parts thereof, which the Company has determined to be defective after
inspection thereof at the Company's factory.
This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by
parties other than the Company, or any modification or alteration of the products. In addition, this
warranty does not cover damage due to improper handling, assembly, installation or maintenance.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EXPRESSED OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE COMPANY
BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES
WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS,
BUSINESS INTERRUPTION OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF THE
PRODUCTS PURCHASED, EVEN IF THE COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. THE COMPANY'S LIABILITY TO THE PURCHASER (OR ANY OTHER PARTY)
HEREUNDER, IF ANY, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS
PAID TO THE COMPANY.