Mid-Continent Instrument MD50 Installation Manual And Operating Instructions

INSTALLATION MANUAL AND
OPERATING INSTRUCTIONS
MD50-( ) Series
Static Electrical Power Inverter
REV. D February 24, 2011 MANUAL NUMBER 9017039
9400 E. 34
phone 316-630-0101 fax 316-630-0723 web www.mcico.com
th
Street N., Wichita, KS 67226 USA
FOREWORD
This manual provides information intended for use by persons who, in accordance with current regulatory requirements, are qualified to install this equipment. If further information is required, please contact:
Mid-Continent Instruments
Attn: Customer Service Dept.
9400 E. 34
th
ST North
Wichita, KS 67226 USA
Phone 316-630-0101 Fax 316-630-0723
We welcome your comments concerning this manual. Although every effort has been made to keep it free of errors, some may occur. When reporting a specific problem, please describe it briefly and include the manual part number, the paragraph/figure/table number, and the page number. Send your comments to:
Mid-Continent Instruments
Attn: Technical Publications
9400 E. 34
th
ST North
Wichita, KS 67226 USA
Phone 316-630-0101, Fax 316-630-0723
info1@mcico.com
www.mcico.com
© Copyright 2010
Mid-Continent Instrument Co., Inc.
REV. D February 24, 2011 2 Manual Number 9017039
REVISION DETAIL
Date Approved Detail
Rev.
A 02/26/10 BAW/JRC Initial release. B 07/06/10 BAW/MKN Update Section 2.4 to add limitation statement regarding output. C 07/20/10 MKN/BAW Update unit picture with True Blue Power label. D 02/24/11 JDS/BAW Added section 3.3.2, and figure 3.4.
REV. D February 24, 2011 3 Manual Number 9017039
TABLE OF CONTENTS
SECTION 1 GENERAL DESCRIPTION
1.1 INTRODUCTION
1.2 TECHNICAL SPECIFICATIONS
1.2.1 ELECTRICAL ATTRIBUTES
1.2.2 PHYSICAL ATTRIBUTES
1.2.3 QUALIFICATIONS
SECTION 2 INSTALLATION CONSIDERATIONS
2.1 COOLING
2.2 EQUIPMENT LOCATION
2.3 ROUTING OF CABLES
2.4 LIMITATIONS
SECTION 3 INSTALLATION PROCEDURE
3.1 GENERAL INFORMATION
3.2 UNPACKING AND INSPECTING
3.3 CABLE HARNESS
3.3.1 WIRE GAUGE SELECTION
3.3.2 PIN ASSIGNMENT INFORMATION
3.3.3 HARNESS VERIFICATION
3.4 MOUNTING
3.5 INSTALLATION COMPLETION
SECTION 4 OPERATION
4.1 ELECTRICAL PERFORMANCE
4.2 PROTECTIVE FEATURES
SECTION 5 CONFORMANCE
5.1 CONTINUED AIRWORTHINESS STATEMENT
5.2 ENVIRONMENTAL QUALIFICATION STATEMENT
NUMBER LIST OF TABLES AND FIGURES
1.1 MODELS TABLE
1.2 PHYSICAL ATTRIBUTES TABLE
1.3 PERFORMANCE TABLE
3.3 CONNECTOR PINOUT FIGURE
3.3 CONNECTOR PINOUT TABLE
3.4 EXAMPLE WIRING DIAGRAMS
3.5 MD50 OUTLINE DRAWING FIGURE
3.6 MD50 MOUNTING ADAPTER FIGURE
4.1 THD PERFORMANCE
4.2 TEMPERATURE PERFORMANCE
REV. D February 24, 2011 4 Manual Number 9017039
SECTION 1 GENERAL DESCRIPTION
1.1 INTRODUCTION
The model MD50 series Static Electrical Power Inverter is a lightweight power converter that translates a 20 to 36 VDC input to a 115 VAC output at 60 Hertz and provides 500 watts (VA) of power. The alternating current output is defined as a pure sine wave with less than 3% of total harmonic distortion for clean, noise-free, harmonic-free power to supply nearly any common commercial or consumer load rated for a nominal input of 115VAC. The MD50 series Inverter is FAA certified to TSO C73 and tested to rigorous environmental standards and levels of RTCA DO-160. The small size and light weight in conjunction with its installation flexibility inside or outside the pressure vessel make it an ideal choice for aircraft power needs while reducing the challenges associated with other similar products.
Highlighted features include short circuit protection, overload capability, low voltage shut-down, temperature monitoring, a self-resettable over-temperature disable, and a remote on/off function. The rugged extrusion that houses the unit is designed to help dissipate heat and provide mechanical strength against vibration or other possibilities of damage. Two independent fans allow for a smaller uni t and provide a quieter operation while keeping the internal components cool and extending the life of the unit.
1.2 TECHNICAL SPECIFICATIONS
1.2.1 ELECTRICAL ATTRIBUTES
Characteristics:
Input Voltage: Rated 28VDC nominal; 20-36VDC certified Input Power: 17-25 amps; 0.2A at no load Output Voltage: 115VAC ±3% at 60 Hertz ±0.1% (single phase) Output Power: 500 watts (500 VA at power factor = 1) Output Waveform: Pure sine wave Power Factor: -0.8 to +0.8 Efficiency: 88% nominal Total Harmonic Distortion (THD): < 3%; See Figure 4.1
1.2.2 PHYSICAL ATTRIBUTES
Characteristics:
Weight: 3.9 pounds Dimensions: (not including connector mate)
Mating Connector (and cable clamp): MS3106A-18-9S or equivalent (MCI P/N 9016905-1 and -2) Mounting: Base mount – orientation not critical
1.2.3 QUALIFICATIONS
Specifications:
Qualification: FAA TSO-C73 Environmental Qualification: RTCA DO-160F Environmental Category
Altitude: -15,000 ft to +55,000 ft Temperature: -55°C to +70°C (-67°F to +158°F); See Figure 4.2
Table 1.1
6.71 inches long (8.15 inches – mounting base)
6.34 inches wide
2.74 inches high
Table 1.2
F3(Y)S2BB(RCC1)XXXXXXZXXXXXBXXXXX
Table 1.3
REV. D February 24, 2011 5 Manual Number 9017039