Midco MPG 1.5G User Manual

Power Gas Burners
MPG Series
Power Gas Burners
The MPG series of gas burners have been developed with modular construction to make them adaptable to many applications. The MPG series is available with the blower on top as standard and also available for the tighter applications with the blower on the bottom. The burners have been UL and UL-C approved. We can provide optional valve trains and controls to meet ASME CSD-1, Factory Mutual, NFPA and GAP (formerly IRI) specifications.
At the heart of the MPG burner efficiency is the innovative burner gas manifold and its stainless steel retention plate, precision engineered to thoroughly mix gas fuel and combustion air for increased combustion efficiency. With less excess oxygen required for combustion, combustion efficiencies can be increased.
MPG Series
Power Gas Burners
Depend on Midco
®
for quality design
and proven performance
MPG 2.5G
with Optional Control Cabinet
The MPG series comes standard with a 120V electronic microprocessor flame safeguard and flame rod sensing or is available with optional UV sensing.
The MPG series of burners can be applied to numerous applications. The standard product is completely factory assembled and fire tested. The standard burner style of firing is on-off with slow opening diaphragm gas valve and fixed air shutter. We have available Hi-Lo-Off firing or 3-1 and 10-1 turndown modulation capabilities. For OEM models, we offer numerous options as well as unassembled valve trains and welded flanges to fulfill many application requirements.
The Unipower MPG GB burners are provided with a 24 volt electronic intermittent pilot ignition module with self diagnostic features employing the flame rectification of flame detection. A 120 volt ignition transformer insuring reliable pilot ignition is standard.
Contact the factory or your local Midco burner representative or distributor, or see our website at
www.midcointernational.com for their listing or additional
MPG Burner information.
MPG 2.5G
with Optional Control Cabinet
Midco International is proud to introduce our NEW line of Power Gas Burners. We have developed two MPG gas burner models that will fire from 150,000 BTU’s minimum to 2,500,000 BTU’s maximum capacity.
MPG 1.5GB
(Inverted)
Standard Features
• Factory fire tested
• Assembled main valve train
• Diaphragm and solenoid redundant main gas valves
• Pilot gas pressure regulator, tubing and manual valve shipped loose
• Main gas pressure regulator and manual valve shipped loose where applicable
• Pilot and main gas manifold pressure taps
• Diaphragm type blower air switch standard for UL
• Differential diaphragm type blower air switch standard for UL-C
• Stainless steel nozzle
• Stainless steel burner retention plate
• MPG 1.5G (B) adjustable mounting flange shipped loose
• MPG 2.5G (B) adjustable mounting flange shipped loose
• Control cabinet with terminal strip
• Microprocessor flame safeguard with LED indicating lights (120 volt only)
• Electronic intermittent pilot ignition module (24 volt only)
• On-Off firing with slow opening main gas valve and fixed air shutter
• Blower motor 115 volt 60 hertz
• Inverted blower on bottom
Modular assembly engineering
enables custom designs
• Unassembled valve train
• Stripped burner basic non-UL
• Single or dual motorized main gas valves
• High and or low gas pressure switches
• Large control cabinet with indicating lights
burner mounted or remote mount
• Welded mounting flange (insertion depth
must be specified)
• 240 volt motor with contactor
• ASME CSD-1, Factory Mutual, GAP, NFPA
components on request
• On-Off low fire start
• Hi-Lo-Off low fire start
• Fully modulating 3-1 turn down
• Fully modulating 10-1 turn down
• Modulation input signal 135 ohm,
4-20mA or 0-10 volts DC
Optional Features Optional Style of Firing
(120 Volt MPG Burners Only)
The MPG burners can be built to specific customer requests. For options not listed contact our sales team.
Midco International Inc.
4140 West Victoria Street Chicago, Illinois 60646 tel 773.604.8700 fax 773.604.4070 web www.midcointernational.com
Quality Designed for Proven Performance
809
8474-95
Printed in U.S.A.
MPG 1.5G Dimensions
4
Specifications
Minimum Input Rating *
Model Numbers Natural** Propane***
* Btu/Hr ** 1000 BTU/cu.ft. ***2500 BTU/cu.ft. (B) 24V Controls and Gas Train
Burner Manifold Pressure On-Off Natural
2
Nozzle
...Insertion ...Depth
4
Min Max
MPG 1.5G (B) 150,000 1,500,000 5" W.C. 5" W.C 30.01 to 1.20" W.C. 0.005 to 0.70 " W.C. 1/2 120 1 3/4" 5 1/2" 1 1/2"
MPG 2.5G (B) 250,000 2,500,000 4" W.C. 4" W.C 0.01 to 0.80" W.C. 0.005 to 0.50 " W.C. 3/4 140 1 3/4" 5 1/2" 2"
Motor HP
Maximum Input Rating *
Shipping Weight
Burner Manifold Pressure Propane
2
Inlet Gas Pressure Required Natural
1
Inlet Gas Pressure Required Propane
1
6" Flange Dimensions
4
for MPG 1.5G (B)
8" Flange Dimensions
4
for MPG 2.5G (B)
MPG 2.5G Dimensions
4
1. Maximum inlet pressure both gases: 14" W.C.
2. Values given based on 0" W.C. firebox pressure, altitudes to 2,000 feet. Derate burner for altitudes over 2,000 feet by 4% for each 1,000 feet over sea level.
3. For lower inlet pressures contact the factory
4. Dimensions are approximate
5. Contact Factory for Hi-Lo-Full Mod Settings
Gas Connection NPT Size
Loading...