Under the insidecover of the unit, there is a two-position fan mode switch. In the first position, the fan runs even if the compressor
of the appliance has stopped continuous operation of the fan. In the second position, the fan only runs simultaneously with the
compressor periodical duty of the fan. The continuous operation mode of the fan is preferable, since the humidity reader built in
the device continuously reads humidity, and thereforea greateraccuracy is reached. Atthe same time,continuous operation of the
fan results in better air circulationin the room. The installationwork supplier selects the mode of thefan according to the request of
the user.
:
:
3.3. Control of the fan
Switch of the fan operation
Start-up of the compressor is, due to its protection, delayed by 3 minutes. Depending on the humidity of the environment, it may
take even longer for compressor to start operating. Once the compressor stops operating, the operation is renewed automatically,
at the earliestafter three minutes. The usermust not handle the setting elementof the delay-actionrelay.
3.4. Control of the compressor
It is necessaryto makesure that the suction inlet and the exhaust outlet are not covered. It isforbidden toplace towels or clothing
items onto the exhaust outlets to dry them. The unit's cover can be cleaned with standard cleaning agents using a soft cloth or
a sponge. Ifwater dripping out of theunit, please check the condensed waterdrain and makesure the pipe isnot obstructed.
At least once a year, it is necessary to have the unit checked and cleaned by a service specialist. This is inevitable to secure a long
service life of the unit. We do not recommend the user to clean the interior elements of the unit, as this might cause a damage to the
unit. The unit containsmobile elementsand liveelements, thereforethe interiorparts mayonly becleaned bya certifiedelectrician
trained to servicerefrigerating appliances.
The unit must be installed in compliance with the local installation and electrical installation regulations !
6.1. Location of the unit
To ensure maximum efficiency, it is necessary to install the unit as high above the ground as possible. It is forbidden to install the
unit onto the ground. It is essential to ensure good air circulation by allowing at least 150 mm of free space under the unit and at
least 200 mm offree spaceabove the unit.For the purposesof maintenance,it isfurther necessary toallow atleast 200mm offree
space on bothsides of the unit.
4. MAINTENANCE INSTRUCTIONS
5. SERVICING THE UNIT
6. INSTALLATION GUIDE
5
Continuous duty of the fan
Periodical duty of the fan
WALL-MOUNTED SWIMMING POOL DEHUMIDIFIER - USER´S MANUAL