Microwave Radio Communications STATXU044T1AK User Manual

STRATA TX
System
Manual Part No. 400504-1
Rev. A March 2005
Analog + Digital Portable 3.4 to 13.25 GHz Microwave Transmitter
Operator’s Guide
Notices
About This Manual
Part number 400504-1
Revision A - March 2005
The information in the manual applies to the Microwave Radio Communications (MRC) STRATA TX System.
Copyright
Proprietary Material
The information and design contained within this manual was originated by and is the property of Microwave Radio Communications. Microwave Radio Communications reserves all patent proprietary design, manufacturing, reproduction use, and sales rights thereto, and to any articles disclosed therein, except to the extent rights are expressly granted to others. The foregoing does not apply to vendor proprietary parts.
To allow for the introduction of design improvements,
specifications are subject to change without notice.
The information in this book may be reproduced by the
purchaser to the extent needed for their organization. No part of this material may be modified in any way or published for resale without the express written authorization of Microwave Radio Communications.
© 2005 Microwave Radio Communications
Microwave Radio Communications
101 Billerica Avenue - Bldg. 6
North Billerica, MA 01862-1256USA
TEL: 978.671.5700
FAX: 978.671.5800
Printed in U.S.A.
Quality Certification
Microwave Radio Communications is certified to ISO 9001:2000.
Regulatory Status
This product is certified to conform to CENELEC standards EN 55020, EN 55013, EN 50082-1, and EN 60950 and carries the CE mark.
Authorized EU representative: Vislink PLC.
Notices iSTRATA TX Operator’s Guide
Conventions
Symbols Used
Pay special attention to information marked in one of the following ways:
WARNING
CAUTION
Note
Notes provide additional information to assist you in using and maintaining the equipment.
Follow WARNINGS closely to prevent personal injury or death.
Follow CAUTIONS to prevent damage to the equipment.
On-Line Viewing
Text displayed as blue contains a hypertext link. Click on the
hypertext to jump to that destination. Click on the
blue destination to return.
The following symbols are used on the equipment:
Symbol Meaning
WARNING: General Warning. Risk of Danger
WARNING: Risk of Electric Shock
WARNING: Electrostatic Discharge. Possible Damage to Equipment
Fuse - Identifies fuses or their location.
Frame or Chassis Ground - Identifies the frame or chassis terminal.
Earth Ground - Identifies the earth Ground Terminal
Viewing this manual on-line requires Adobe Acrobat, version 4.0 or above.
Click on this icon to download your FREE copy of Adobe Acrobat Reader.
Notices iiSTRATA TX Operator’s Guide
Protective Earth Ground - Identifies any terminal which is intended for connection to an external conductor for protection against electric shock in case of a fault, or the terminal on a protective earth electrode.
Warranty Information
Product Manufactured by MRC:
a. Products manufactured by MRC are warranted against defects in material and workmanship for a period of two (2) years from date of delivery as evidenced by MRC's packing slip or other transportation receipt (unless otherwise noted).
b. MRC's sole responsibility under this warranty will be to either repair or replace, at its option, any component which fails during the applicable warranty period because of a defect in material or workmanship, provided Buyer has promptly reported same to MRC in writing. All replaced products and parts will become MRC's property.
c. MRC will honor the warranty at the repair facility designated by MRC. It is Buyer's responsibility to return, at its expense, the allegedly defective product to MRC. Buyer must obtain a Return Material Authorization (RMA) number and shipping instructions from MRC prior to returning any product under warranty. Transportation charges for the return of the product to Buyer will be paid by MRC within the United States. For all other locations, the warranty excludes all costs of shipping, customs clearance and other related charges. If MRC determines that the product is not defective within the terms of this warranty, Buyer will pay MRC all costs of handling, transportation and repairs at the then prevailing repair rates.
d. All the above warranties are contingent upon proper use of the product. These warranties will not apply (1) if adjustment, repair, or product or parts replacement is required because of accident, unusual physical, electrical or electromagnetic stress, neglect, misuse, failure of electric power, environmental controls, transportation, failure to maintained properly or otherwise in accordance with MRC specifications, or abuses other than
ordinary use; (2) if the product has been modified by Buyer or has been repaired or altered outside MRC's repair facility, unless MRC specifically authorizes such repairs or alterations in each instance; or (3) where MRC serial numbers, warranty data or quality assurance decals have been removed or altered.
e. No person, including any dealer, agent or representative of MRC is authorized to assume for MRC any other liability on its behalf except as set forth herein. If any payment is due MRC for services performed hereunder, it will be subject to the same payment terms as the original purchase.
Products Manufactured By Others:
For products not manufactured by MRC, the original manufacturer's or licensor's warranty will be assigned to Buyer to the extent permitted by the manufacturer or licensor and is in lieu of any other warranty, expressed or implied. For warranty information on a specific product, a written request should be made to MRC.
All Products:
THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES, OBLIGATIONS, AND LIABILITIES ON THE PART OF MRC. EXCEPT FOR THE EXPRESS WARRANTIES STATED HEREIN, MRC DISCLAIMS ALL WARRANTIES ON PRODUCTS FURNISHED HEREUNDER, INCLUDING, WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. MRC WILL HAVE NO RESPONSIBILITY FOR ANY PARTICULAR APPLICATION MADE OF ANY EQUIPMENT.
Any description of equipment, whether in writing or made orally by MRC or its agents, specification sheets, models, bulletins,
Notices iiiSTRATA TX Operator’s Guide
drawings, or similar materials used in connection with Buyer's order are for the sole purpose of identifying the equipment and will not be construed as an express warranty. Any suggestions by MRC or its agents regarding use, application or suitability of the equipment will not be construed as an express warranty. No warranties may be implied from any course of dealing or usage of trade. Buyer agrees that the exclusion of all warranties, other than those expressly provided herein, is reasonable.
Notices ivSTRATA TX Operator’s Guide
Contents
About This Manual - - - - - - - - - - - - - - - - - - - - - - - - i Copyright - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i Proprietary Material - - - - - - - - - - - - - - - - - - - - - - - i Quality Certification - - - - - - - - - - - - - - - - - - - - - - - i Regulatory Status - - - - - - - - - - - - - - - - - - - - - - - - - i
Conventions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ii
On-Line Viewing - - - - - - - - - - - - - - - - - - - - - - - - - - ii Symbols Used- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ii Warranty Information - - - - - - - - - - - - - - - - - - - - - - - - - iii
Product Manufactured by MRC: - - - - - - - - - - - - - - - iii
Products Manufactured By Others:- - - - - - - - - - - - - iii
All Products: - - - - - - - - - - - - - - - - - - - - - - - - - - - - iii
Introduction - - - - - - - - - - - - - - - - - - - - - - - - - 1-1
Chapter Overview - - - - - - - - - - - - - - - - - - - - - - - - - 1-1 What This Manual Covers - - - - - - - - - - - - - - - - - - - 1-1 How It’s Organized - - - - - - - - - - - - - - - - - - - - - - - - 1-1 For Whom It’s Written - - - - - - - - - - - - - - - - - - - - - - 1-2 Related Documents - - - - - - - - - - - - - - - - - - - - - - - - 1-2 Ordering Documentation - - - - - - - - - - - - - - - - - - - - 1-2 Calling for Service - - - - - - - - - - - - - - - - - - - - - - - - - 1-2 Supported Repairs - - - - - - - - - - - - - - - - - - - - - - - - 1-3 Tell Us What You Think! - - - - - - - - - - - - - - - - - - - - 1-3
Product Description- - - - - - - - - - - - - - - - - - - 2-1
Chapter Overview - - - - - - - - - - - - - - - - - - - - - - - - - 2-1 System Description - - - - - - - - - - - - - - - - - - - - - - - - 2-1
System Options - - - - - - - - - - - - - - - - - - - - - - - - 2-2
Single Unit Systems - - - - - - - - - - - - - - - - - - - - - 2-3
Multi-Unit Systems - - - - - - - - - - - - - - - - - - - - - - 2-3
Remote Control Options - - - - - - - - - - - - - - - - - - 2-3
Antenna and Power Options - - - - - - - - - - - - - - - 2-3
Mounting and Deployment Options - - - - - - - - - - - 2-5 System Integration - - - - - - - - - - - - - - - - - - - - - - 2-5
System Components - - - - - - - - - - - - - - - - - - - - - - - 2-7
STRATA TXU - - - - - - - - - - - - - - - - - - - - - - - - - - 2-7 STRATA TCU - - - - - - - - - - - - - - - - - - - - - - - - - - 2-7 STRATA ACU - - - - - - - - - - - - - - - - - - - - - - - - - - 2-8
STRATA Remote Control Panels - - - - - - - - - - - - 2-8 TXU and TCU Configurations - - - - - - - - - - - - - - - - - 2-9 Typical System Configurations - - - - - - - - - - - - - - - 2-12 For More Information - - - - - - - - - - - - - - - - - - - - - - 2-12
Routine Operation - - - - - - - - - - - - - - - - - - - - 3-1
Chapter Overview - - - - - - - - - - - - - - - - - - - - - - - - - 3-1 Overview of Controls, Indicators, and Connectors - - - 3-2
TXU Controls, Indicators, and Connectors - - - - - - 3-2
TCU Controls, Indicators, and Connectors - - - - - - 3-5
ACU Controls, Indicators, and Connectors- - - - - - 3-8
STRATA Standard Remote Control Panel Controls, Indi-
cators, and Connectors - - - - - - - - - - - - - - - - - - - - - - - - 3-9
STRATA Aircraft Remote Control Panel Controls, Indica-
tors, and Connectors - - - - - - - - - - - - - - - - - - - - - - - - - - 3-9
Preparing for Operation - - - - - - - - - - - - - - - - - - - - 3-10
Mobile Installation - - - - - - - - - - - - - - - - - - - - - - 3-10
Portable Deployment - - - - - - - - - - - - - - - - - - - - 3-10
Powering the STRATA TX System - - - - - - - - - - 3-12
Single TCU Power Up and Power Down - - - - - - 3-13
Single TXU Power up and Power Down- - - - - - - 3-14
TXU and TCU Power Up and Power Down - Co-Located
3-15
TXU and TCU Power Up and Power Down - Separate Lo-
cations - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-17
Using the STRATA TX Screens - - - - - - - - - - - - - - - 3-19 TXU and/or TCU Monitoring Operations - - - - - - - - - 3-20
Here are the tasks described:
Contents-1STRATA TX Operator’s Guide
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-20 Using the Monitor Screens in MPEG Output Mode 3-20 Using the Monitor Screens in Ext IF Input Mode 3-22 Using the Monitor Screens in COFDM - IF Mode 3-23 Using the Monitor Screens in COFDM ASI In Mode 3-24 Using the Monitor Screens in Analog - IF Mode - 3-25 Using the Monitor Screens in DVB-S Mode- - - - 3-26
TXU and/or TCU Control Operations - - - - - - - - - - - 3-27
Changing a Preset - - - - - - - - - - - - - - - - - - - - - 3-29 Setting a Channel - - - - - - - - - - - - - - - - - - - - - - 3-30 Setting Power Output - - - - - - - - - - - - - - - - - - - 3-31 Controlling TCU to TXU DC Power on Coax - - - 3-32
Front Panel vs. STRATA TX Configurator Settings - 3-34
Troubleshooting - - - - - - - - - - - - - - - - - - - - - 4-1
Chapter Overview - - - - - - - - - - - - - - - - - - - - - - - - - 4-1 Status LED - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-1 Messages on Display- - - - - - - - - - - - - - - - - - - - - - - 4-1 Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-3
Primary Error Code- - - - - - - - - - - - - - - - - - - - - - 4-3 Error Status - - - - - - - - - - - - - - - - - - - - - - - - - - 4-8 Unit ID - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-8
Operational Problems - - - - - - - - - - - - - - - - - - - - - - 4-8
Channels & Frequencies - - - - - - - - - - - - - - - A-1
Appendix Overview - - - - - - - - - - - - - - - - - - - - - - - - A-1 Initial Factory Presets - - - - - - - - - - - - - - - - - - - - - - A-1
3.4 to 3.8 GHz Channel Plan - - - - - - - - - - - - - - - A-1
4.4 to 5.0 GHz Channel Plan - - - - - - - - - - - - - - - A-2
6.4 to 7.1 GHz Channel Plan - - - - - - - - - - - - - - - A-2
6.9 to 7.5 GHz Channel Plan - - - - - - - - - - - - - - - A-3
7.4 to 8.0 GHz Channel Plan - - - - - - - - - - - - - - - A-3
7.8 to 8.5 GHz Channel Plan - - - - - - - - - - - - - - - A-4
8.2 to 8.9 GHz Channel Plan - - - - - - - - - - - - - - - A-4
10.0 to 10.7 GHz Channel Plan - - - - - - - - - - - - - A-5
10.5 to 11.2 GHz Channel Plan - - - - - - - - - - - - - A-5
10.8 to 11.5 GHz Channel Plan - - - - - - - - - - - - - A-6
12.7 to 13.25 GHz Channel Plan- - - - - - - - - - - - - A-6
Glossary - - - - - - - - - - - - - - - - - - - - - - - - - - - B-1
Contents-2STRATA TX Operator’s Guide
1
Introduction
1.1 Chapter Overview
1.3 How It’s Organized
The manuals for the STRATA TX System are organized as follows:
This chapter will introduce you to the Operator’s Guide: what it covers, how it’s organized, and for whom it’s written.
1.2 What This Manual Covers
This manual describes how to operate the STRATA TX Transmitter System.
For information on Installation, Repair, Replacement Parts, and Theory of Operation, refer to the STRATA TX Technical Reference Manual.
This manual also covers various configurations of the STRATA TX System. Your STRATA TX System will consist of one of the following configurations:
A Standalone Transmitter Control Unit (TCU)
A Standalone Transmitter Unit (TXU)
A TCU and TXU.
Your TX System may be mounted on a tripod or may be mounted in a vehicle or in an aircraft. Your TX System may also include an optional MRC AC to DC Converter Unit (ACU).
If your system is mounted in a vehicle or in an aircraft, it may include an optional MRC Remote Control Panel or Aircraft Remote Control Panel. This manual provides coverage for all of these various configurations.
Chapter
Introduction
Product Description
Routine Operation
Advanced Operation
Installation
Troubleshooting
Repair
Replacement Parts
Theory of Operation
Appendix A - Channels & Frequencies
Appendix B - Glossary
Appendix C ­Configurator Reference
Operator’s
Guide
Technical
Reference
Manual
Introduction 1-1STRATA TX Operator’s Guide
Note
The Technical Reference Manual contains everything in the Operator’s Guide, plus additional technical content.
Tuesday - Friday
8:00 AM - 7:00 PM Eastern Time (US)
(0800 - 1900 hrs US ET)
Telephone: 800-490-5700
1.4 For Whom It’s Written
This manual is intended for use by personnel assigned to operate the STRATA TX System. Users of this manual should already be familiar with basic concepts of radio, video, and audio.
1.5 Related Documents
STRATA TX System Technical Reference Manual
(part no. 400505-1)
STRATA TX System Quick Reference Card
(part no. 400506-1)
STRATA Aircraft Remote Control Panel Operator’s Guide
(part no. 400490)
STRATA Remote Control Panel Operator’s Guide (part no. 400489)
1.6 Ordering Documentation
Any of the above manuals may be ordered by contacting MRC Customer Service:
978-671-5700
Fax: 978-671-5800
When contacting Customer Service, please have the following information available:
Model number and serial number of the unit. This is located on a label on the bottom of each unit.
Approximate purchase date.
Firmware revision, which appears on the TXU or TCU alphanumeric display at startup.
or
Firmware revision(s) displayed on the Main page of the STRATA TX Configurator, when the STRATA TX Configurator is connected to the TXU or TCU.
1.7 Calling for Service
MRC Technical Support is available 24 hours a day, 7 days a week. During regular business hours you can reach our expert staff directly. After hours, your call will be forwarded to the on-call Technical Support specialist.
Business Hours: Monday
8:00 AM - 5:00 PM Eastern Time (US)
(0800 - 1700 hrs US ET)
Business Hours: Monday
8:00 AM - 5:00PM Eastern Time (US)
(0800 - 1700 hrs US ET)
Introduction 1-2STRATA TX Operator’s Guide
Tuesday - Friday
8:00 AM - 7:00PM Eastern Time (US)
(0800 - 1900 hrs US ET)
If you attempt field repair, you risk damaging your equipment. If your equipment is under warranty, you may also
affect your warranty coverage.
Telephone: 800-490-5700
978-671-5700
Fax: 978-671-5800
E-mail: support@mrcbroadcast.com
When contacting Technical Support, please have the following information available:
Model number and serial number of the unit. This is located on a label on the bottom of each unit.
Approximate purchase date.
Firmware revision, which appears on the TXU or TCU alphanumeric display at startup.
1.8 Supported Repairs
The STRATA TX System, including the TXU, TCU, and optional ACU, is designed to be compact, rugged and reliable.
1.9 Tell Us What You Think!
We’d appreciate any comments or suggestions you have about this manual. The more feedback we get, the better the manuals get!
If you’re viewing this manual electronically, it’s easy - just click on the link below send us an E-mail.
Feedback
Or, you can E-mail our Technical Support team at:
support@mrcbroadcast.com.
Be sure to tell us what product you’re writing about, and which manual - the Operator’s Guide, the Quick Reference Card, or the Technical Reference Manual.
The TXU and TCU require specialized test equipment to calibrate amplitude and frequency characteristics after repair. In addition, sealing the TXU, TCU, or optional ACU enclosures after repair requires exacting techniques and special fixtures to ensure weather resistance of the units.
Therefore, there are NO supported field repairs to either the TXU, TCU, or ACU.
Return the entire unit for factory repair.
Introduction 1-3STRATA TX Operator’s Guide
This page intentionally left blank.
Introduction 1-4STRATA TX Operator’s Guide
2
Product Description
2.1 Chapter Overview
This chapter provides an overall description of the STRATA TX System, its components, and its capabilities.
Here are the topics covered:
2.2 System Description
The STRATA TX System is a highly reliable, flexible, and compact portable microwave transmitter system ideal for tripod, airborne, or mobile installations. A typical STRATA TX System is composed of the Transmitter Unit (TXU) and the Transmitter Control Unit (TCU), as shown in Figure 2-1 on page 2-2. This modular architecture allows you the maximum flexibility in configuration, siting, and operation.
The STRATA TX System key features are:
Topic Page
System Description 2-1
System Options 2-2
Single Unit Systems 2-3
Multi-Unit Systems 2-3
Remote Control Options 2-3
Antenna and Power Options 2-3
Mounting and Deployment Options 2-5
System Integration 2-5
System Components 2-7
STRATA TXU 2-7
STRATA TCU 2-7
STRATA ACU 2-8
STRATA Remote Control Panels 2-8
TXU and TCU Configurations 2-9
Typical System Configurations 2-12
For More Information 2-12
Analog, Digital, or Analog/Digital Switchable
MPEG Encoding (4:2:0, 4:2:2)
COFDM Modulation with Selectable Guard Band Interval
Digital Modulation for QPSK, 16 QAM, and 64 QAM
NTSC or PAL Modulation with Audio (4 mono or 2 stereo)
Tripod, Half Rack, or Full Rack Mounts
Front Panel Local Control
Remote Control
Bands from 3.4 to 13.25 GHz
Product Description 2-1STRATA TX Operator’s Guide/Tech Ref Manual
Figure 2-1: STRATA TX System Block Diagram
1.84 MHz OOK Tone
y NTSC y PAL y SDI y ASI y IF
IN
RS-232
Telemetry
TCU TXU
DC Power and/or IF
+28 VDC
The STRATA TX System TXU and the TCU may be operated in stand-alone configurations depending upon specific video applications.
2.2.1 System Options
The STRATA TX System can be ordered configured for 1 of 11 specific RF bands as follows:
3.4 to 3.9 GHz
4.4 to 5.0 GHz
6.4 to 7.1 GHz
6.9 to 7.5 GHz
7.4 to 8.1 GHz
7.8 to 8.5 GHz
8.2 to 8.9 GHz
Telemetry
RF Out
RS-232
+28 VDC
10.0 to 10.7 GHz
10.5 to 11.2 GHz
10.8 to 11.5 GHz
12.7 to 13.25 GHz
MRC is constantly working to expand and upgrade the capabilities of the STRATA TX System. Consult your Sales Representative or contact the factory for the latest band availability.
The STRATA TX System (typically) consists of the following components:
TXU The Transmitter Unit (TXU) can be equipped with either an FM Modulator or COFDM/MPEG module, but not both. A High Power Unit (HPU) is also contained within the TXU housing to increase RF power output.
Product Description 2-2STRATA TX Operator’s Guide/Tech Ref Manual Product Description 2-2STRATA TX Operator’s Guide/Tech Ref Manual
TCU The Transmitter Control Unit (TCU) can be equipped with either an FM Modulator or COFDM/MPEG module, or both.
where the transmitter needs to be placed in another location.
ACU The optional AC to DC Power Converter (ACU) provides +28 VDC power from an AC power source to power one or more units in a system.
Remote Control Panels Optional Remote Control Panels are available to allow remote control of the STRATA TX System from an instrument panel during airborne or mobile operations.
2.2.2 Single Unit Systems
The TXU or TCU may be used independently in single-unit applications as follows:
The TXU may be used as a stand-alone transmitter accepting an IF input.
The TXU may be used as a stand-alone transmitter featuring FMT modulation or MPEG and COFDM.
The TCU may be used as a stand-alone unit used for FMT modulation or MPEG and COFDM, or both FMT modulation and MPEG and COFDM.
2.2.3 Multi-Unit Systems
The TXU and TCU can be configured as part of an integrated system as follows:
The TCU may contain the FMT modulator and MPEG/ COFDM module supplying an IF signal to a TXU containing only the RF transmitter.
The TXU may contain the RF modulator or MPEG/ COFDM module supplying an RF signal directly to the transmitter antenna.
2.2.4 Remote Control Options
For portable mobile or airborne operations, the STRATA TX System may be controlled by one of two models of Remote Control Panels. The Remote Control Panels are mounted in mobile racks or aircraft instrument panels and are connected via an RS-232 cable between the Remote Control Panel and the STRATA TX System.
2.2.5 Antenna and Power Options
The flexible architecture of the STRATA TX System allows a number of options for both the transmit antenna and the power.
Antenna Options The STRATA TX System is fully compatible with the MRC family of transmit antennas, including:
OmniPole omnidirectional
Megahorn compact horn
SectorScan flat panel
MicroScan parabolic
Ellipse parabolic
Contact your Sales Representative to explore the wide array of antenna choices available.
CAUTION
To prevent damage to your STRATA TX System, MRC recommends using a +28 VDC power supply. Do not exceed +36 VDC input power or damage will occur.
The TCU can be separated from the TXU in applications
Product Description 2-3STRATA TX Operator’s Guide/Tech Ref Manual
Power Options The STRATA TX System configurations operate on +28 VDC power, supplied externally. This DC power can be supplied by the optional STRATA ACU, or from another DC power source. Contact your Sales Representative for the latest details.
Note
A TCU and TXU are defined as being “co-located” when the TXU and TCU are physically separated by not greater than 6 feet.
supply must be greater than +24 VDC.
Refer to the “Installation” Chapter on page 6-1 (part of the STRATA TX Technical Reference Manual only) for additional information.
For those applications that use a TCU in a standalone mode, i.e., to generate ASI or DVB-S signals, DC power from the TCU to the TXU or from the TXU to the TCU cannot be used.
Figure 2-3: Powering the TXU from the TCU
If the TXU and TCU are co-located, power must be supplied to each unit through their individual power connectors from the same power source. See Figure 2-2. Do not use DC on coax to power the TXU or TCU when the units are co-located.
Figure 2-2: Powering the TXU and TCU Independently
STRATA
TXU
DC Power (+28 V)
If your installation calls for separating the TXU and TCU, the TXU is powered by DC supplied by the TCU or the TCU is powered by DC supplied by the TXU. The DC power is superimposed on the coaxial cable connected between the units. See Figure 2-3 and Figure 2-4.
STRATA
TCU
Branched Power Cable
STRATA
Coax
TXU
Up to 600 ft.
(180 m)
DC Power (+28 V)
Figure 2-4: Powering the TCU from the TXU
Coax
STRATA
TXU
Up to 600 ft.
(180 m)
DC Power (+28 V )
STRATA
TCU
Power Cable
STRATA
TCU
The DC input voltage to the unit co-located with the DC power
Product Description 2-4STRATA TX Operator’s Guide/Tech Ref Manual
DC power superimposed on the coaxial cable between a TCU and a TXU can be supplied from either the TCU or TXU, depending upon the location of the DC power supply. Coaxial cable length/voltage limitations exist when powering from either the TXU or TCU. These limitations are based on cable size, DC voltage input, cable resistance, and cable length. A maximum length of 600 feet (180 meters) between the TXU and TCU is supported. Contact MRC Technical Support for more information on cable requirements.
DC power required for a STRATA TX System depends upon the TX System configuration, i.e., if the TXU or TCU are operated in a standalone mode, if the TXU and TCU are co-located, or if the TXU and TCU are mounted in separate locations. See Figure 2-
5 on page 2-6 for the various STRATA TX System configurations
available.
For TX Systems that use DC power sources other than a STRATA ACU, contact MRC Technical Support for additional power information.
2.2.6 Mounting and Deployment Options
The STRATA TX offers a number of options for either mobile or portable applications.
For more details on installation of the STRATA TX in various applications, see the “Installation” Chapter on page 6-1 (part of the STRATA TX Technical Reference Manual only).
Mobile Installation For mobile applications such as in a vehicle or in an aircraft, the STRATA TX System is usually mounted in an MRC fixed mounting bracket and is installed in a bulkhead or compartment. The cabling is permanently installed and power comes from aircraft or vehicle power.
Portable Deployment In portable applications, the STRATA TX
System will be moved from place to place and set up each time. The TXU and TCU will usually be mounted in a MRC universal mounting bracket. The bracket is attached to a tripod using a mounting plate and quick release.
The cabling between the TXU and TCU is typically left in place and the power, antenna, and audio/video connections are removed at the end of each deployment.
2.2.7 System Integration
System Communication When the TXU and TCU are connected, they automatically communicate via signals superimposed on the coaxial cable between the two units. This allows them to share information on installed hardware, preset configurations, current status, and alarms.
System Operation Once the TXU and TCU are connected and communicating, the units work seamlessly together. System settings can be selected and modified from the front panel of either unit, regardless of which unit holds the hardware being configured.
System Configuration The STRATA TX System offers two levels of system configuration, designed to match the needs of different personnel.
For the field operator, the STRATA TX System has up to 9 Presets that can be selected from the front panel. Each Preset controls key parameters such as modulation, frequency, and audio and video settings. Additional settings that are front panel­controlled include band, channel, offset, and filtering.
For the advanced operator and technical staff, the STRATA TX Configurator software allows complete control of all parameters in the STRATA TX System. The STRATA TX Configurator software runs on a Windows-based PC and connects to either the TXU or the TCU via an RS-232 serial interface cable.
Product Description 2-5STRATA TX Operator’s Guide/Tech Ref Manual
Interfacing a PC to either the TXU or TCU in a connected system gives you complete control of both units. You can read the current settings, program new settings, or return the units to their factory default settings. The STRATA TX Configurator software
Figure 2-5: STRATA TX System Options
automatically detects what hardware is installed in the system and assigns the appropriate configuration to the correct hardware, regardless of which unit holds the hardware being configured.
NTSC or PAL Video with 4 Audio Channels Available
SDI, ASI, NTSC, or PAL Video + Audio
Analog Video or Digital Video + Audio
NTSC or PAL Video with 4 Audio Channels Available
70 MHz IF Input Only
SDI, ASI, NTSC, or PAL + Digitial/Analog Audio
TCU
COFDM / MPEG
& FMT
Monitor
TCU
COFDM / MPEG
Monitor
TCU
FMT Only
TXU
RF/IF Only
TXU
FMT Option
TXU
COFDM / MPEG Option
TXU
RF/IF Only
TXU
RF/IF Only
TXU
RF/IF Only
3.4 to 13.25 GHz
RF Output
RXU
Product Description 2-6STRATA TX Operator’s Guide/Tech Ref Manual
2.3 System Components
This section will provide more details about each the components of a STRATA TX System:
•STRATA TXU
STRATA TCU
•STRATA ACU
STRATA Remote Control Panels
For details on connections between the STRATA TX System components, refer to the “Installation” chapter (part of the STRATA TX Technical Reference Manual only).
2.3.1 STRATA TXU
The TXU (Figure 2-6) always contains an IF/RF module that accepts either a 70 MHz COFDM, FMT IF, or external 70 MHz input signal and up-converts these signals to the required RF band. The RF frequency synthesizer circuit included in the IF/RF unit, in conjunction with the command and control power supply module, provides the means to channelize RF video and audio signals in the TX System RF band.
The TXU, with either an analog (FMT) or digital (MPEG/COFDM) module, is integrated in the same housing as the HPU components. This provides the ability to incorporate high RF power output (12 watts of saturated RF power) into a single analog or digital transmitter assembly.
Figure 2-6: STRATA TXU
Standard U.S. FCC band plans, as well as customer-created channel plans, may be customized using the STRATA TX Configurator software.
As noted previously, the TXU may also include either an MPEG/ CODFM or FMT module (but not both), in which case the TXU serves as a stand-alone digital or analog video microwave transmission system.
2.3.2 STRATA TCU
The TCU (Figure 2-7 on page 2-8) may contain either analog or digital or both analog and digital video modulation modules. Where an application might initially employ only analog video transmission but expects to migrate to dual, switchable, analog and digital operation, the TCU may be upgraded to add the MPEG/COFDM module to add this capability.
Product Description 2-7STRATA TX Operator’s Guide/Tech Ref Manual
Figure 2-7: STRATA TCU
OUTPUT
< >
DC
Figure 2-8: AC to DC Converter
< >
DC
OUTPUT
Where only digital or analog video transmission is desired, the MPEG/COFDM or FMT modules may be installed in a TXU, thereby eliminating the need for a TCU. The STRATA TX design does not permit splitting digital and analog video modulator modules between a TXU and a TCU.
A TCU may also consist of a stand-alone configuration whereby either or both MPEG/COFDM and FMT modules may be used independent of the TXU. This configuration permits use of a TCU equipped with analog and/or digital video modulation modules for a variety of signal input and output configurations, including a digital option using NTSC or PAL composite video input and ASI (digital) signal output.
2.3.3 STRATA ACU
For fixed or portable deployment applications, the STRATA TX System may be powered by the optional AC to DC Converter (ACU). Figure 2-8.
The ACU installs as part of an integrated stack for either tripod or fixed applications. The ACU may also be used to power the TXU or TCU only when a TXU and TCU are not co-located. In this case, the TXU would receive DC power from the TCU or the TCU would receive DC power from the TXU superimposed on the coaxial cable connected between the units.
In standalone TXU or TCU operations, the optional ACU may be used to supply DC power directly to the applicable unit. In the case where a TXU and a TCU are co-located, it is recommended that both the TXU and TCU be powered directly from the ACU in lieu of supplying DC power from the TCU to the TXU or from the TXU to the TCU via the coaxial cable connected between the units.
2.3.4 STRATA Remote Control Panels
For mobile or airborne operations, two Remote Control Panel models are currently available. Contact your Sales Representative for the latest information.
Both Remote Control Panel models provide simplified transmit
Product Description 2-8STRATA TX Operator’s Guide/Tech Ref Manual
operations by allowing the operator or pilot to select either analog or digital pre-configured Presets, Channels, and Offsets, depending upon the required operating mode.
Standard Remote Control Panel The standard STRATA Remote Control Panel (Figure 2-9) provides instrument panel remote control of the STRATA TX System for mobile operations and features 9 selectable Presets.
For additional information, refer to the STRATA Remote Control Panel Operator’s Guide (part no. 400489).
Figure 2-9: Standard Remote Control Panel
For additional information, refer to the STRATA Aircraft Remote Control Panel Operator’s Guide (part no. 400490).
Figure 2-10: Aircraft Remote Control Panel
2.4 TXU and TCU Configurations
TXU Different configurations of the TXU are available, depending upon if your TX System contains a standalone TXU or if your TX System contains both a TXU and TCU. The different configurations are described below.
Aircraft Remote Control Panel The STRATA Aircraft Remote Control Panel (Figure 2-10) is a simplified version of the standard STRATA Remote Control Panel. This panel provides instrument panel remote control of the STRATA TX System for airborne operations. This model features only two Presets for ease of operation.
The unit is designed to fit a standard aircraft instrument panel and provides user-friendly controls, combined with well placed and easy to read LED displays and color indicators.
Product Description 2-9STRATA TX Operator’s Guide/Tech Ref Manual
If your TXU is equipped with either an analog (FMT) module or a digital (MPEG/COFDM) module and was ordered to operate in a standalone mode without a TCU, the front panel will contain an
AUDIO connector. See Figure 2-11 on page 2-10.
Figure 2-11: Standalone TXU Configuration
Figure 2-12: TXU - TXU with TCU Configuration
DO NOT EXCEED 36 VOLTS DC
AUDIO
Connector
SIGNAL INPUT
Connector
Front View
PWR/RS-485
Connector
If your TXU was ordered to operate with a TCU, it will not contain either analog or digital modules and will therefore not contain an
AUDIO connector. The AUDIO connector is replaced by a DC ON COAX switch. See Figure 2-12.
The DC ON COAX switch allows manual control of DC power to the TXU from the TCU or from the TCU to the TXU via DC power superimposed on the coaxial cable connected between the two units.
The rear of the TXU is identical on both configurations of the TXU, as shown in Figure 2-12.
DC ON COAX Switch
SIGNAL INPUT
Connector
DC ON COAX
OFF ON
Front View
Rear View
DO NOT EXCEED 36 VOLTS DC
PWR/RS-485
Connector
RF Output
Connector
RS-232
Connector
Product Description 2-10STRATA TX Operator’s Guide/Tech Ref Manual
TCU Several different configurations of the TCU also exist as the result of technical updates. Configuration differences are described below.
DC power to a TXU.
Figure 2-14: TCU - Newer Configuration
TCU - Older Configuration If your TCU is an older configuration, the controls and connectors contained on the TCU are similar to those shown in Figure 2-13. Older configurations do not contain the front panel DC ON COAX override switch to provide manual control of DC power to a TXU.
Figure 2-13: TCU - Older Configuration
TX
RS-232 Connector
POWER
Connector
SIGNAL OUT
Connector
TCU
Front View
Monitor (MON)
Connector
XMIT
AUDIO
Connector
RS-232 Connector
POWER
Connector
SIGNAL OUT
Connector
TX
TCU
Front View
Monitor (MON)
Connector
Rear View
XMIT
DC ON COAX Switch
AUDIO
Connector
SIGNAL IN
Connector
Rear View
SIGNAL IN
Connector
TCU - Newer Configuration If your TCU is the newer configuration, the controls and connectors contained on the TCU are similar to those shown in Figure 2-14. A DC ON COAX switch is located on the front panel to provide manual control of
Product Description 2-11STRATA TX Operator’s Guide/Tech Ref Manual
2.5 Typical System Configurations
2.6 For More Information
Typical STRATA TX System configurations are shown in Figure
2-15.
Figure 2-15: STRATA TX System Configurations
Additional detailed technical information about the STRATA TX System is contained in the STRATA TX Technical Reference Manual. Specific topics contained in the Technical Reference Manual are listed below:
Topic Chapter
Installation See Chapter 6, “Installation
Connections to other equipment
Changing settings using the Configurator software
Block Diagram See Chapter 9, “Theory of
Supported Repairs See Chapter 7, “Repair
Repair Parts See Chapter 8, “Replacement
See Chapter 6, “Installation
See Chapter 5, “Advanced
Operation
Operation
Parts
Product Description 2-12STRATA TX Operator’s Guide/Tech Ref Manual
3
Routine Operation
3.1 Chapter Overview
This chapter provides basic information that will enable you to operate your STRATA TX System.
Here are the topics covered:
Topic Page
Overview of Controls, Indicators, and Connectors
TCU Controls, Indicators, and Connectors
TCU Controls, Indicators, and Connectors
ACU Controls, Indicators, and Connectors
STRATA Standard Remote Control Panel Controls, Indicators, and Connectors
STRATA Aircraft Remote Control Panel Controls, Indicators, and Connectors
Preparing for Operation 3-10
Mobile Installation 3-10
Portable Deployment 3-10
Powering the STRATA TX System 3-12
Single TCU Power Up and Power Down 3-13
3-2
3-5
3-5
3-8
3-9
3-9
Using the STRATA TX Screens 3-19
TXU and/or TCU Monitoring Operations 3-20
Using the Monitor Screens in MPEG Output Mode
Using the Monitor Screens in Ext IF Input Mode
Using the Monitor Screens in COFDM ­IF Mode
Using the Monitor Screens in COFDM ASI In Mode
Using the Monitor Screens in Analog ­IF Mode
Using the Monitor Screens in DVB-S Mode
TXU and/or TCU Control Operations 3-27
Changing a Preset 3-29
Setting a Channel 3-30
Setting Power Output 3-31
Controlling TCU to TXU DC Power on Coax
Front Panel vs. STRATA TX Configurator Settings
3-20
3-22
3-23
3-24
3-25
3-26
3-32
3-34
Information on settings made with the STRATA TX Configurator software can be found in the “Advanced Operation” Chapter on
page 5-1 (part of the STRATA TX System Technical Reference
Manual only).
Single TXU Power up and Power Down 3-14
TXU and TCU Power Up and Power Down - Co-Located
TXU and TCU Power Up and Power Down - Separate Locations
3-15
3-17
For a summary of settings that can be made with the TXU and TCU front panel control switches and which settings are made using the STRATA TX Configurator, see Section 3.7 on page 3-
34.
Routine Operation 3-1STRATA TX Operator’s Guide/Tech Ref Manual
3.2 Overview of Controls, Indicators, and Connectors
Figure 3-1: TXU Controls, Indicators, and Connectors - Front View
This section describes the controls, indicators, and connectors used on the STRATA TX System.
3.2.1 TXU Controls, Indicators, and Connectors
Controls, indicators, and connectors contained on the TXU are identified and described below. Topics covered are as follows:
Topic Page
TXU Front Panel DC ON COAX Switch
TXU SIGNAL INPUT Connector 3-3
TXU AUDIO Connector 3-3
TXU Alphanumeric Display 3-3
TXU XMIT LED 3-3
TXU Status LED 3-4
TXU PWR/RS-485 Connector 3-4
TXU PWR Switch 3-4
TXU Control Switch 3-4
TXU RF Output Connector 3-5
TXU RS-232 Connector 3-5
Each of these controls, indicators, and connectors are described in more detail in the following paragraphs.
Controls, indicators, and connectors contained on the TXU front panel are shown in Figure 3-1. Connectors contained on the TXU rear panel are shown in Figure 3-2 on page 3-3. For configuration differences in the TXU, see “TXU and TCU
Configurations” on page 2-9.
3-2
XMIT
DC ON COAX
OFF ON
DC ON COAX Switch or AUDIO Connector
SIGNAL INPUT Connector
LED
Alpha-
numeric Display
Status LED
DO NOT EXCEED 36 VOLTS DC
Control Switch
PWR/RS-485
Connector
Power Switch
The TXU is configured using Windows PC-based STRATA TX Configurator software. For details, see the “Advanced Operation”
Chapter on page 5-1 (part of the STRATA TX System Technical
Reference Manual only).
TXU Front Panel DC ON COAX Switch DC ON COAX
switches are not contained on all configurations of the TXU. For configuration differences, see Section 2.4 on page 2-9.
If your STRATA TX System contains both a TXU and a TCU, the System allows you to power the TXU using DC power supplied from the TCU or allows you to power the TCU using DC power from the TXU. This DC power is superimposed on the coaxial cable between the TCU and the TXU. This DC power option is used when the TCU and the TXU must be deployed in two separate locations.
Routine Operation 3-2STRATA TX Operator’s Guide/Tech Ref Manual
Figure 3-2: TXU Controls, Indicators, and Connectors - Rear View
•The 75 Ohm Coax option on the Command Screen.
RF Output Connector
RS-232
Connector
When the TCU and TXU are co-located, MRC recommends both units be powered from the same DC power source.
If your STRATA TX System does not contain a TCU, the DC ON COAX switch will not be present and an AUDIO connector will be mounted in place of the switch.
If your STRATA TX System contains both a TXU and a TCU, the System gives you several ways to control DC power on the coaxial cable from the TCU to the TXU, depending on the configurations of your TCU and TXU:
•The DC ON COAX switch on the front panel of the TCU (See Figure 3-3 on page 3-6) and the DC ON COAX switch on the front panel of the TXU (Figure 3-1 on
page 3-2).
Both control methods must be enabled for DC power to be operational if your TCU and TXU configurations both contain the DC ON COAX switches. If the DC ON COAX switch is not present on your TCU, DC power can only be applied using the
75 Ohm Coax option on the command screen. The TXU DC ON COAX switch must be set to ON in either situation.
TXU SIGNAL INPUT Connector The BNC INPUT connector
provides the IF or video input to the TXU.
TXU AUDIO Connector AUDIO connectors are not contained
on all configurations of the TXU. For configuration differences, see Section 2.4 on page 2-9.
If your TXU contains an AUDIO connector, all audio inputs are applied to the front panel mounted 10-pin connector.
TXU Alphanumeric Display The TXU contains a two-line by
12-character alphanumeric display. The display works in conjunction with the Control Switch to allow you to monitor system status and to control system settings.
TXU XMIT LED When the TXU Control Switch is pressed for
one second, the transmitter changes from the standby mode to the transmit mode or changes from the transmit mode to the standby mode. When the transmitter is in the transmit mode, the XMIT LED illuminates blue. When the transmitter is in the standby mode, the XMIT LED is off.
If your STRATA TX System contains both a TXU and a TCU, pressing the Control switch on either the TXU or TCU will change the transmitter to the transmit mode or to the standby mode. The XMIT LED on both units will be on or off, depending
Routine Operation 3-3STRATA TX Operator’s Guide/Tech Ref Manual
Loading...
+ 61 hidden pages