Microwave Data Systems MDS 1710 A, MDS 2710A, MDS 2710D, MDS 2710C, MDS 1710 C Operation Manual

Microwave Data Systems Inc.
Rochester, NY 14620
General Business: +1 585 242-9600
FAX: +1 585 242-9620
Web: www.microwavedata.com
175 Science Parkway
A product of Microwave Data Systems Inc.
Installation & Operation Guide
MDS 05-3447A01, REV. F
SEPTEMBER 2004
Data Transceiver
Microwave Data Systems Inc.
MDS 1710 A/C
MDS 2710A/C/D
QUICK START GUIDE
Below are the basic steps for installing the transceiver. Detailed instructions are provided in “Installation
Steps” on Page 9 of this manual.
1. Install and connect the antenna system to the radio
• Use good quality, low loss coaxial cable. Keep the feedline as short as possible.
• Preset directional antennas in the direction of desired transmission/reception.
2. Connect the data equipment to the radio’s INTERFACE connector
• Connection to the radio must be made with a DB-25 Male connector. Connections for typical sys­tems are shown below.
• Connect only the required pins. Do not use a straight-through RS-232 cable with all pins wired.
•Verify the data equipment is congured as DTE. (By default, the radio is congured as DCE.)
3. Apply DC power to the radio (10.5–16 Vdc @ 2.5 A minimum)
• Observe proper polarity. The red wire is the positive lead; the black is negative.
4. Set the radio’s basic conguration with a Hand-Held Terminal (HHT)
• Set the transmit frequency (
TX xxx.xxxxx
).
• Set the receive frequency (
RX xxx.xxxxx
).
• Set/verify the data rate using the
BAUD
command. The default setting is
BAUD 4800 8N1
. (Refer to
“TRANSCEIVER PROGRAMMING” on Page 17 for command details.)
5. Verify proper operation by observing the LED display
• Refer to Tab le 5 on Page 16 for a description of the status LEDs.
•Refine directional antenna headings for maximum receive signal strength using the
RSSI
com-
mand.
DB-25 DB-25
2
3
2
3
4
5
20
6DSR
DSR
6
TXD
RXD
GND
RTS
CTS
TXD
RXD
GND
4
CTS
5
RTS
DB-9 DB-25
DB-9 to DB-25 ExampleDB-25 to DB-25 Example
11
4
5
2
3
3
2
5
20
7
RXD
TXD
DCD
GND
DSR
RTS
RXD
TXD
DCD
GND
As required for application
5
18
7
6
CTS
DSR
RTS
CTS8
6
4
5
77
GND
GND
8 8
DCD
DCD
As required for application
RTU
(DTE)
TRANSCEIVER
(DCE)
RTU
(DTE)
TRANSCEIVER
(DCE)
IN CASE OF DIFFICULTY...
MDS products are designed for long life and trouble-free operation. However, this equip­ment, as with all electronic equipment may have an occasional component failure. The following information will assist you in the event that servicing becomes necessary.
FACTORY TECHNICAL ASSISTANCE
Technical assistance for MDS products is available from our Customer Support Team during business hours (8:00 A.M.–5:30 P.M. Eastern Time). When calling, please give the complete model number of the radio, along with a description of the trouble symptom(s) that you are experiencing. In many cases, prob­lems can be resolved over the telephone, without the need for returning the unit to the factory.
Please use one of the following means for product assistance:
Phone: 585-241-5510
E-mail: techsupport@microwavedata.com
Web: www.microwavedata.com
FAX: 585-242-8369
FACTORY REPAIRS
Component-level repair of radio equipment is not recommended in the field. Many compo-
nents are installed using surface mount tech­nology, which requires specialized training and equipment for proper servicing. For this reason, the equipment should be returned to the factory for any PC board repairs. The factory is best equipped to diagnose, repair and align your radio to its proper operating specifi­cations.
If return of the equipment is necessary, you will be issued a Service Return Order (SRO) number. The SRO number will help expedite the repair so that the equipment can be repaired and returned to you as quickly as possible. Please be sure to include the SRO number on
the outside of the shipping box, and on any correspondence relating to the repair. No
equipment will be accepted for repair without an SRO number.
A statement should accompany the radio describing, in detail, the trouble symptom(s), and a description of any associated equipment normally connected to the radio. It is also important to include the name and telephone number of a person in your organization who can be contacted if additional information is required.
The radio must be properly packed for return to the factory. The original shipping container and packaging materials should be used when­ever possible. All factory returns should be addressed to:
When repairs have been completed, the equip­ment will be returned to you by the same ship­ping method used to send it to the factory. Please specify if you wish to make different shipping arrangements. To inquire about an in­process repair, you may contact our Product Services Group at: 585-241-5540 (FAX: 585­242-8400) or vie e-mail at: ProductServices@microwavedata.com.
Microwave Data Systems Inc. Product Service Department (SRO No. XXXX) 175 Science Parkway Rochester, NY 14620 USA
I-6 MDS 1710A/C and MDS2710A/C/D MDS 05-3447A01, Rev. F
NOTES
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D i
TABLE OF CONTENTS
1.0 GENERAL.................................................................................... 1
1.1 Introduction ......................................................................................1
1.2 Differences Between Models ...........................................................2
1.3 Applications ...................................................................................... 2
Point-to-Multipoint, Multiple Address Systems (MAS) ....................2
Point-to-Point System..................................................................... 3
Continuously Keyed versus Switched Carrier Operation................ 4
Single Frequency (Simplex) Operation........................................... 4
1.4 Product Congurator Codes .............................................................4
1.5 Accessories ...................................................................................... 5
2.0 GLOSSARY OF TERMS.............................................................. 5
3.0 INSTALLATION ............................................................................ 8
3.1 Installation Steps .............................................................................. 9
3.2 Transceiver Mounting .....................................................................11
3.3 Antennas and Feedlines ................................................................11
Feedlines ......................................................................................12
3.4 Power Connection .......................................................................... 12
3.5 Data Interface Connections ............................................................13
3.6 Using the Radio’s Sleep Mode ....................................................... 13
Sleep Mode Example ...................................................................13
4.0 OPERATION.............................................................................. 15
4.1 LED Indicators ................................................................................16
4.2 RSSI Measurement ........................................................................ 16
5.0 TRANSCEIVER PROGRAMMING ............................................17
5.1 Hand-Held Terminal Connection & Startup ....................................17
5.2 Hand-Held Terminal Setup .............................................................18
5.3 Keyboard Commands .....................................................................19
Entering Commands..................................................................... 19
Error Messages ............................................................................19
5.4 Detailed Command Descriptions ...................................................22
AMASK [0000 0000–FFFF FFFF] ................................................22
ASENSE [HI/LO]........................................................................... 23
BAUD [xxxxx abc]......................................................................... 23
BUFF [ON, OFF]........................................................................... 23
CKEY [ON–OFF] ..........................................................................24
CTS [0–255] .................................................................................24
DATAKEY [ON, OFF] ....................................................................24
DEVICE [DCE, CTS KEY] ............................................................24
DKEY............................................................................................ 25
ii MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
DLINK [ON/OFF/xxxx] ..................................................................25
DMGAP [xx].................................................................................. 25
DTYPE [NODE/ROOT]................................................................. 25
DUMP ...........................................................................................26
HREV............................................................................................ 26
INIT............................................................................................... 26
INIT [2710].................................................................................... 26
INIT [2720].................................................................................... 26
KEY ..............................................................................................27
MODEL......................................................................................... 27
MODEM [xxxx, NONE] .................................................................27
OWM [XXX...] ...............................................................................27
OWN [XXX...]................................................................................ 27
PTT [0–255].................................................................................. 27
PWR [20–37] ................................................................................27
RSSI .............................................................................................28
RTU [ON/OFF/0-80]......................................................................28
RX [xxx.xxxxx] ..............................................................................28
RXTOT [NONE, 1-255]................................................................. 28
SCD [0-255].................................................................................. 28
SER ..............................................................................................28
SHOW [DC, PORT, PWR].............................................................29
SNR ..............................................................................................29
SREV............................................................................................ 29
STAT ............................................................................................. 29
TEMP............................................................................................ 29
TOT [1-255, ON, OFF] ..................................................................30
TX [xxx.xxxxx]............................................................................... 30
UNIT [10000...65000] ...................................................................30
6.0 TROUBLESHOOTING............................................................... 30
6.1 LED Indicators ................................................................................31
6.2 Event Codes ...................................................................................31
Checking for Alarms—STAT command.........................................31
Major Alarms vs. Minor Alarms..................................................... 31
Event Code Denitions .................................................................32
7.0 TECHNICAL REFERENCE .......................................................33
7.1 Transceiver Specications ..............................................................33
7.2 Performing Network-Wide Remote Diagnostics ............................. 34
7.3 Bench Testing Setup ......................................................................36
7.4 Helical Filter Adjustment ................................................................37
7.5 Upgrading the Radio’s Software .....................................................38
Using Radio Software Upgrade Diskette ......................................38
Using Radio Conguration Software.............................................39
7.6 dBm-Watts-Volts Conversion Chart ................................................ 40
I-5 MDS 1710A/C and MDS2710A/C/D MDS 05-3447A01, Rev. F
length vs. loss in coaxial cables 12
Technical reference 33–40 Technical reference,
bench test setup,
36–37
TEMP command 29 Temperature, displaying internal (TEMP command) 29 Testing. See bench testing TEXT TOO LONG error message
20
Timer, set/display time-out value and status (TOT command) 30 TOT command 30 Transceiver
applications
2
conguring for operation 10 connectors and indicators, illustrated 1 diagnostics using PC software 38 dimensions, mounting 11 mounting 9, 11 programming 17–20 specications 33–34 upgrading software 38
Transmit Audio Input pinout (Pin 9) 14 Transmitter
specications
33
system specications 33
Troubleshooting 30–32
connecting Hand-Held Terminal (HHT) for displaying alarm
codes
17
performing network-wide diagnostics 34 STAT command (Status) 31 using PC software for 38
TX command 30 TXD LED
description
16
Pin 2 14
U
UNKNOWN COMMAND error message 19
I-4 MDS 1710A/C and MDS2710A/C/D MDS 05-3447A01, Rev. F
entering commands using the Hand-Held Terminal (HHT) 19 helical lter adjustment 37 installation 9 measuring RSSI with DC voltmeter 16 network-wide diagnostics 34 operation 15, 16 performance optimization 15 reading LED status indicators 16 resetting Hand-Held Terminal (HHT) 18 troubleshooting 30–32
Product
accessories 5 description 1 display model number code (MODEL command) 27 display radio serial number (SER command) 28
Programming radio as root or node 35 Programming, transceiver 17–20 PTT
command 27 pinout (Pins 14, 16) 14
PWR
command 27 LED 16
R
Radio
Conguration Software 5, 38 Inhibit pinout (Pin 12) 14 serial number, displaying (SER command) 28
Receive Audio Output pinout (Pin 11) 14 Receiver
specications
34
system specications 33 unsquelched signal (Pin 10) 14
Redundant operation, dened 8 Remote
RTU reset (Pin 15) 14 Station, dened 8 Station, illustrated 9
Resetting
Hand-Held Terminal (HHT) (SHIFT,CTRL,SPACE keys)
18
remote RTU reset (Pin 15) 14 transceiver (INIT command) 26
Revision level
display hardware (HREV command) 26 display software (SREV command) 29
RSSI
adjusting helical lter for increased signal strength
37
command 28 command, used to rene antenna heading 15 measuring 16 pinout (Pin 21) 15 vs. Vdc, illustrated 13, 16
RTS pinout (Pin 4) 14 RTU
command 28
RTU (Remote Terminal Unit)
dened 8 remote reset (Pin 15) 14
RTU simulator, 36 RUS pinout (Pin10) 14 RX command 28 RXD LED
description 16 Pin 3 14
RXTOT command 28
S
SCADA (Supervisory Control And Data Acquisition), dened 8 SCD command 28 SER command 28 Set
alarm output state (ASENSE command) 23 alarm triggers (AMASK command) 22 receive time-out timer value (RXTOT command) 28
SHOW command 29 Signal
ground (Pin 7) 14 loss due to coaxial cable length, table 12
Simplex 3
single-frequency operation 4 special case of switched carrier operation 4
Sleep mode
example implementation 13 ground on Radio Inhibit pin activates 14 Pin 12 14 shown by PWR LED status indicator 16
SNR command 29 Software
diagnostics and control used from PC 38 display revision level 29 upgrades (.S28 les) 38 upgrading 38 used for diagnostics and programming 17
Specications
diagnostics interface 34 environment 34 power 34 receiver 34 receiver system 33 transceiver 33–34 transmitter 33 transmitter system 33
SREV command 29 STAT command 29 SWR (Standing Wave Radio), dened 8
T
Tables
accessories
5
alarm code denitions 32 command summary 20 conversions, dBm-Watts-Volts 40 data interface connector pinouts 14 Hand-Held Terminal (HHT) operational settings 19 LED status indicators 16
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D iii
Copyright Notice
This Installation and Operation Guide and all software described herein are protected by copyright: © 2004 Microwave Data Systems Inc . All rights reserved. MDS reserves its right to correct errors and omissions.
To Our Customers
We appreciate your patronage. You are our business. We promise to serve and anticipate your needs. We will strive to give you solutions that are cost effective, innovative, reliable and of the highest quality possible. We promise to build a relationship that is forthright and ethi­cal, one that builds condence and trust.
RF Safety Notices
MDS 1710, 5 Watts
The radio equipment described in this guide emits radio frequency energy. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. Do not allow people to come closer than 1.80 meters to the front of the antenna when the trans­mitter is operating with a 7 dBd (9.15 dBi) gain antenna. Use of higher gain antennas means increasing the distance accordingly.
This manual is intended to guide a professional installer to install, operate and perform basic system maintenance on the described radio.
MDS 2710A/C, 2 Watts
The radio equipment described in this guide emits radio frequency energy. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. Do not allow people to come closer than 0.425 meters to the front of the antenna when the transmitter is operating with a 0 dBd (2.15 dBi) gain antenna. Use of higher gain antennas means increasing the distance accordingly.
This manual is intended to guide a professional installer to install, operate and perform basic system maintenance on the described radio.
MDS 2710D, 5 Watts
The radio equipment described in this guide emits radio frequency energy. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. Do not allow people to come closer than 1.50 meters to the front of the antenna when the trans­mitter is operating with a 7 dBd (9.15 dBi) gain antenna. Use of higher gain antennas means increasing the distance accordingly.
This manual is intended to guide a professional installer to install, operate and perform basic system maintenance on the described radio.
RF Exposure
iv MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
ISO 9001 Registration
Microwave Data Systems’ adheres to this internationally accepted qual­ity system standard.
FCC Approval Notice
At the printing date, MDS 1710 models are approved for operation in the USA from150 to 174 MHz. MDS 2710 models are approved for opera­tion in the USA from 216 to 222 MHz. Contact MDS for current approval status.
CSA/
US
Notice
This product is available for use in Class I, Division 2, Groups A, B, C & D Hazardous Locations. Such locations are defined in Article 500 of the National Fire Protection Association publication NFPA 70, other­wise known as the National Electrical Code.
The product has been recognized for use in hazardous locations by the Canadian Standards Association (CSA), which also issues the US mark of approval (CSA/
US
). The CSA Certification is in accordance with CSA STD C22.2 No. 213-M1987. The product has been evaluated in accordance with the following standards:
• CSA Std C22.2 No. 142-M1987 - Process Control Equipment
• CSA Std C22.2 No. 213-M1987 - Non-Incendive Electrical Equipment for
Use in Class I, Division 2 Hazardous Locations
• ANSI/UL Std No. 508 - Industrial Control Equipment
• UL Std No. 1604 - Electrical Equipment for Use in Class I and II, Division
2; Class III Hazardous (Classified) Locations
FCC Part 15 Notice
The transceiver complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device is specifically designed to be used under Section 15.247 of the FCC Rules and Regulations. Any unauthorized modification or changes to this device without the express approval of Microwave Data Systems may void the user’s authority to operate this device. Further­more, this device is intended to be used only when installed in accor­dance with the instructions outlined in this manual. Failure to comply with these instructions may also void the user’s authority to operate this device.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS2710A/C/D I-3
MAS network 3 MDS 2710A/D model number codes 4 network-wide diagnostics 35 point-to-point link 3 remote station arrangement 9 RJ-11 to DB-9 adapter cable 36 RSSI vs. Vdc 13, 16 transceiver connectors & indicators 1 transceiver mounting dimensions 11
INCORRECT ENTRY error message 19 INIT command 26 INIT xx10 command 26 INIT xx20 command 26 InSite software
using to perform remote diagnostics 34
Installation 8–15
antenna 9 conguring transceiver 10 DATA INTERFACE connection 9 data interface connections 13 power 9 power connection 12 steps 9
Intrusive diagnostics (dened) 7
K
KEY command 27 Keying
continuously keyed versus switched carrier operation 4 continuously keyed, dened 4 on data (DKEY command) 25 switched carrier, dened 4
L
Latency, dened 7 LEDs
DCD
16
indicators, described 16 PWR 16 RXD 16 RXD, Pin 3 14 status indicators, illustrated 16 TXD 16 TXD, Pin 2 14
Loss. See Signal
M
MAS (Multiple Address System) 2
dened 7 illustration 3
Master Station
dened
7
keying behavior 4
MCU (Microcontroller Unit), dened 7 MODEL command 27 Model number codes
displaying (MODEL command)
27
MDS 2710A/D, illustrated 4
MODEM command 27 Modem, set speed. See MODEM command
N
Network-wide diagnostics
active messaging, dened
5
dened 7 enable/disable (DLINK command) 25 enable/disable internal RTU (RTU command) 28 illustrated 35 intrusive diagnostics, dened 7 passive messaging (dened) 7 procedures 34 set radio to Root or Node (DTYPE command) 25 set time to wait between characters (DMGAP command) 25
NOT AVAILABLE error message 20 NOT PROGRAMMED error message 20
O
Operation 15–16
environment, specications for 34
Output, 9.9 Vdc regulated, pinout (Pin 19) 15 OWM command 27 OWN command 27 Owner’s message, set/display. See OWM command Owner’s name, set/display. See OWN command
P
Passive messaging (dened) 7 Payload data (dened) 8 Performance
testing,
36–37
Pinouts on data interface 14 PLC (Programmable Logic Controller), dened 8 Point-to-multipoint
dened
8
system 2
Point-to-point
link, illustrated
3
system 3
Poll, dened 8 Power
connection
12
display DC voltage (SHOW command) 29 display RF output (SHOW command) 29 installing 9 LED status indicator (PWR LED) 16 RF, chart for converting dBm-Watts-Volts 40 specications 34
Power attenuators, use of in testing 37 Procedures
checking for alarms (STAT command)
31
connecting Hand-Held Terminal (HHT) 17 downloading new software 38
I-2 MDS 1710A/C and MDS2710A/C/D MDS 05-3447A01, Rev. F
Description, product 1 Detailed 22 DEVICE command 24 Diagnostic Channel Enable, pinout (Pin 23) 15 Diagnostics
interface specications 34 network-wide, performing 34 PC software used for 38 using InSite software for network-wide 34
Differences between models 2 Display
alarm status (STAT command)
29
alarm triggers (AMASK command) 22 all programmed settings (DUMP command) 26 baud rate and encoding (BAUD command) 23 connector port, active (SHOW command) 29 CTS line response timer (CTS command) 24 data handling mode (BUFF command) 23 DC voltage (SHOW command) 29 hardware revision leve (HREV command)l 26 key-up delay (PTT command) 27 model number code (MODEL command) 27 owner’s message (OWM command) 27 owner’s name (OWN command) 27 radio behavior (DEVICE command) 24 radio serial number (SER command) 28 receive frequency (RX command) 28 receive time-out timer value (RXTOT command) 28 RF forward output power (PWR command) 27 RF output (SHOW command) 29 RSSI (RSSI command) 28 signal-to-noise ratio (SNR command) 29 soft-carrier dekey delay (SCD command) 28 software revision level (SREV command) 29 temperature, internal (TEMP command) 29 time-out value and timer status (TOT command) 30 transmit frequency (TX command) 30
DKEY command 25 DLINK command 25
use of 35
DMGAP command 25 Downloading new software 38 DSP (Digital Signal Processing), dened 6 DSR pinout (Pin 6) 14 DTE (Data Terminal Equipment), dened 6 DTYPE command 25
use of 35
DUMP command 26
E
EEPROM FAILURE error message 20 Enable/disable
continuous keying (CKEY command)
24
diagnostic channel, pinout (Pin 23) 15 internal RTU (RTU command) 28 network-wide diagnostics (DLINK command) 25 network-wide diagnostics, procedures 35
Environment specications 34
Equalization, dened 6 Error messages 19
access denied 20 command failed 20 EEPROM failure 20 incorrect entry 19 not available 20 not programmed 20 text too long 20 unknown command 19
F
Fade margin, dened 7 Feedlines 12 Filter, helical, adjustment 37 Frame, dened 7 Frequency
adjusting helical lter when changed
37
setting. See TX and RX commands
G
Glossary 5 Ground
on Pin 12 to enable Sleep mode
14
protective (Pin 1) 14 signal (Pin 7) 14
H
Half-duplex 3
switched carrier operation 4
Hand-Held Terminal (HHT) 5
connected to transceiver, illustrated 18 connection and startup 17 display in response to STAT command, illustrated 31 entering commands 19 error messages displayed on 19 keyboard commands 19 operational settings, table 19 reinitialization display, illustrated 18 reinitializing 18
Hardware ow control, dened 7 Helical lter
adjusting
37
illustration 38
Host computer, dened 7 HREV command 26
I
Illustrations
antenna, Yagi 12 Hand-Held Terminal (HHT) connected to transceiver 18 Hand-Held Terminal (HHT) reinitialization display 18 Hand-Held Terminal display in response to STAT command 31 helical lter locations 38
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D v
Manual Revision and Accuracy
While every reasonable effort has been made to ensure the accuracy of this manual, product improvements may result in minor differences between the manual and the product shipped to you. If you have addi­tional questions or need an exact specification for a product, please con­tact our Customer Service Team using the information at the back of this guide. In addition, manual updates can often be found on the MDS Web site at www.microwavedata.com. Microwave Data Systems Inc. reserves the right to correct all errors or omissions in this document without obligation to any party.
vi MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS2710A/C/D I-1
INDEX
A
ACCESS DENIED error message 20 Accessories 5 Accessory Power pinout (Pin 18) 14 Active messaging (dened) 5 Alarms
alarm code denitions
32
major vs. minor 31 pinout (Pin 25) 15 using STAT command to display 29
AMASK command 22 Antenna
installation
9
RSSI command used to rene heading 15 system gain, dened 6 Yagi, illustrated 12
Antennas 11–12 Applications 2
Multiple Address Systems (MAS) 2 point-to-multipoint system 2 point-to-point system 3
ASENSE command 23
B
BAUD command 23 Baud rate
setting for RJ-11 DIAG port (DLINK command)
25, 35
Bench testing (radio performance), 36–37 Bit, dened 6 Bits-per-second. See BPS BPS (bits-per-second), dened
6
BUFF command 23 Byte, dened 6
C
Cable, loss due to length of coaxial 12 Cautions
use attenuation between all units in test setup
35
CKEY command 24 COMMAND FAILED error message 20 Command summary, table 20 Commands
AMASK (set/display alarm triggers)
22
ASENSE (set alarm output state) 23 BAUD (set/display rate, encoding) 23 BUFF (set/display data handling mode) 23 CKEY (enable/disable continuous keying) 24 CTS (set/display CTS line response timer) 24
DATAKEY (enable/disable transmitter keying by radio) 24 DEVICE (set/display radio behavior) 24 DKEY (deactivate transmitter after KEY command) 25 DLINK (enable/disable network-wide diagnostics) 25 DMGAP (set time to wait between characters) 25 DTYPE (set radio to Root or Node for diagnostics) 25 DUMP (display all programmed settings) 26 entering on Hand-Held Terminal (HHT) 19 Hand-Held Terminal (HHT) 19 HREV (display hardware revision level) 26 INIT (reinitialize radio to factory defaults) 26 INIT xx10 (restore standard transceiver defaults) 26 INIT xx20 (congure radio for use with P-20 chassis) 26 KEY (activate transmitter) 27 MODEL (display radio model number code) 27 MODEM (set modem speed) 27 OWM (set/display owner’s message) 27 OWN (set/display owner’s name) 27 PTT (set/display key-up delay) 27 PWR (set/display RF forward output power) 27 RSSI (display RSSI) 28 RTU (enable/disable internal RTU) 28 RX (set/display receive frequency) 28 RXTOT (set/display receive time-out timer value) 28 SCD (set/display soft-carrier dekey delay) 28 SER (display radio serial number 28 SHOW (display DC voltage, data port, RF power) 29 SNR (display signal-to-noise ratio) 29 SREV (display software revision level) 29 STAT (display current alarm status) 29 TEMP (display internal temperature) 29 TOT (set/display time-out value and timer status) 30 TX (set/display transmit frequency) 30
Conversions, dBm-Watts-Volts 40 CTS command 24 CTS pinout (Pin 5) 14
D
Data interface
connector pinouts
14
display active connector port 29 installing connection 13
DATAKEY command 24 dB. See Decibel 6 dBi, dened 6 dBm, dened 6 DCD
LED
16
pinout (Pin 8) 14
DCE (Data Cirtuit-terminating Equipment), dened 6 Decibel (dB), dened 6
40 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
7.6 dBm-Watts-Volts Conversion Chart
Table 9 is provided as a convenience for determining the equivalent
wattage or voltage of an RF power expressed in dBm.
Table 9. dBm-Watts-Volts Conversion—for 50 Ohm Systems
dBm V Po
+53 100.0 200W +50 70.7 100W +49 64.0 80W +48 58.0 64W +47 50.0 50W +46 44.5 40W +45 40.0 32W +44 32.5 25W +43 32.0 20W +42 28.0 16W +41 26.2 12.5W +40 22.5 10W +39 20.0 8W +38 18.0 6.4W +37 16.0 5W +36 14.1 4W +35 12.5 3.2W +34 11.5 2.5W +33 10.0 2W +32 9.0 1.6W +31 8.0 1.25W +30 7.10 1.0W +29 6.40 800mW +28 5.80 640mW +27 5.00 500mW +26 4.45 400mW +25 4.00 320mW +24 3.55 250mW +23 3.20 200mW +22 2.80 160mW +21 2.52 125mW +20 2.25 100mW +19 2.00 80mW +18 1.80 64mW +17 1.60 50mW +16 1.41 40mW +15 1.25 32mW +14 1.15 25mW +13 1.00 20mW +12 .90 16mW +11 .80 12.5mW +10 .71 10mW +9 .64 8mW +8 .58 6.4mW +7 .500 5mW +6 .445 4mW +5 .400 3.2mW +4 .355 2.5mW +3 .320 2.0mW +2 .280 1.6mW +1 .252 1.25mW
dBm V Po
0 .225 1.0mW
-1 .200 .80mW
-2 .180 .64mW
-3 .160 .50mW
-4 .141 .40mW
-5 .125 .32mW
-6 .115 .25mW
-7 .100 .20mW
-8 .090 .16mW
-9 .080 .125mW
-10 .071 .10mW
-11 .064
-12 .058
-13 .050
-14 .045
-15 .040
-16 .0355
dBm mV Po
-17 31.5
-18 28.5
-19 25.1
-20 22.5 .01mW
-21 20.0
-22 17.9
-23 15.9
-24 14.1
-25 12.8
-26 11.5
-27 10.0
-28 8.9
-29 8.0
-30 7.1 .001mW
-31 6.25
-32 5.8
-33 5.0
-34 4.5
-35 4.0
-36 3.5
-37 3.2
-38 2.85
-39 2.5
-40 2.25 .1µW
-41 2.0
-42 1.8
-43 1.6
-44 1.4
-45 1.25
-46 1.18
-47 1.00
-48 0.90
dBm mV Po
-49 0.80
-50 0.71 .01µW
-51 0.64
-52 0.57
-53 0.50
-54 0.45
-55 0.40
-56 0.351
-57 0.32
-58 0.286
-59 0.251
-60 0.225 .001µW
-61 0.200
-62 0.180
-63 0.160
-64 0.141
dBm µV Po
-65 128
-66 115
-67 100
-68 90
-69 80
-70 71 .1nW
-71 65
-72 58
-73 50
-74 45
-75 40
-76 35
-77 32
-78 29
-79 25
-80 22.5 .01nW
-81 20.0
-82 18.0
-83 16.0
-84 11.1
-85 12.9
-86 11.5
-87 10.0
-88 9.0
-89 8.0
-90 7.1 .001nW
-91 6.1
-92 5.75
-93 5.0
-94 4.5
-95 4.0
-96 3.51
-97 3.2
dBm µV Po
-98 2.9
-99 2.51
-100 2.25 .1pW
-101 2.0
-102 1.8
-103 1.6
-104 1.41
-105 1.27
-106 1.18
dBm nV Po
-107 1000
-108 900
-109 800
-110 710 .01pW
-111 640
-112 580
-113 500
-114 450
-115 400
-116 355
-117 325
-118 285
-119 251
-120 225 .001pW
-121 200
-122 180
-123 160
-124 141
-125 128
-126 117
-127 100
-128 90
-129 80 .1ƒW
-130 71
-131 61
-132 58
-133 50
-134 45
-135 40
-136 35
-137 33
-138 29
-139 25
-140 23 .01ƒW
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 1
1.0 GENERAL
1.1 Introduction
This guide presents installation and operating instructions for MDS 1710A/C and MDS 2710 A/C/D series digital radio transceivers.
These transceivers (Figure 1) are data telemetry radios designed to operate in a point-to-multipoint environment, such as electric utility Supervisory Control and Data Acquisition (SCADA) and distribution automation, gas field automation, water and wastewater SCADA, and on-line transaction processing applications. They use microprocessor control and Digital Signal Processing (DSP) technology to provide highly reliable communications even under adverse conditions.
MDS 1710/2710 Series radios use continuous-phase frequency shift keying (CPFSK) modulation with root duo-binary filtering (the sum of two Nyquist-shaped, root-raised cosine responses). Demodulation uses a Virterbi decoder and equalization with soft decision decoding.
Modulation and demodulation is accomplished using Digital Signal Pro­cessing (DSP). DSP adapts to differences between components from unit to unit, and ensures consistent and repeatable performance in ambient temperatures from –30 to +60 degrees Celsius. The use of Dig­ital Signal Processing eliminates the fluctuations and variations in modem operation that can degrade the operation of analog circuits.
Figure 1. Transceiver Connectors and Indicators
The transceiver is designed for trouble-free operation with data equip­ment provided by many other manufacturers, including Remote Ter­minal Units (RTUs), programmable logic controllers (PLCs), flow computers, lottery terminals, automatic teller machines, and others.
EXTERNAL
INTERFACE
CONNECTOR
(DB-25)
DIAGNOSTICS CONNECTOR (RJ-11)
13.8 VDC POWER CONNECTOR
ANTENNA CONNECTOR (TYPE “N”)
SERIAL NUMBER
LABEL
LED INDICATORS (4)
2 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
NOTE: Some features may not be available, based on the options
purchased and the applicable regulations for the region in which the radio will operate.
1.2 Differences Between Models
All models of the MDS 1710/2710 Series are very similar in appearance and functionality. The major differences are in frequency coverage, channel bandwidth and data speed. Table 1 summarizes the available models and identifies the characteristics of each.
To determine the specific settings for your radio (as originally shipped from the factory), please refer to the Product Configurator chart shown in Figure 4.
NOTE: The operating software for A, C, and D models is not inter-
changeable.
NOTE: The narrow bandwidth of the MDS 2710D transceiver is not
compatible with standard analog modems, including the widely used Bell 202T. The MDS 2710D is intended for digital RS-232 data only.
1.3 Applications
Point-to-Multipoint, Multiple Address Systems (MAS)
This is the most common application of the transceiver. It consists of a central master station and several associated remote units as shown in
Figure 2. An MAS network provides communications between a central
host computer and remote terminal units (RTUs) or other data collection devices. The operation of the radio system is transparent to the computer equipment.
Table 1. MDS 1710/2710 Series Characteristics
Radio
Model No.
Operating
Frequency
Channel
Bandwidth
Over-the-Air
Data Speed
Output
Power (W)
MDS 1710A 130–174 MHz 12.5 kHz 9600 bps 5
MDS 1710C 130–174 MHz 25 kHz 19200 bps 5
MDS 2710A 216–220 MHz 12.5 kHz 9600 bps 2
MDS 2710A 220–240 MHz 12.5 kHz 9600 bps 5
MDS 2710C 216–220 MHz 25 kHz 19200 bps 2
MDS 2710C 220-240 MHz 25 kHz 19200 bps 5
MDS 2710D 220–222 MHz 5 kHz 3200 bps 5
Consult factory for current regulatory approvals on these products.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 39
The upgrade software can be run on an IBM-compatible computer con­nected to the radio’s
DIAG. port via an RJ-11 to DB-9 adapter (MDS P/N
03-3246A01). If desired, an adapter cable may be constructed from scratch using the information shown in Figure 13.
To initiate the upgrade, insert the upgrade diskette in Drive A:. Set the working directory to
A: (example: from a DOS prompt type A:\). Next,
type
UPGRADE and press the ENTER key. (If you have the radio connected
via the Com2 serial port, type
UPGRADE-2 instead.) The upgrade soft-
ware will normally run automatically without any further prompts.
The radio’s
PWR LED will flash rapidly to confirm that a download is
in process. The download takes about two minutes.
NOTE: If a software download fails, the radio is left unprogrammed
and inoperative. This is indicated by the PWR LED flashing slowly (1 second on, 1 second off). This condition is only likely if a power failure occurred to the computer or radio during the downloading process. The download can be attempted again when the fault has been corrected.
Using Radio Configuration Software
If you already have software that you wish to download into the trans­ceiver, Radio Configuration Software (MDS P/N 03-3156A01) may be used to perform the installation. To use this method, proceed as follows:
Connect a PC to the radio’s
DIAG. port via an RJ-11 to DB-9 adapter
(MDS P/N 03-3246A01). If desired, an adapter cable may be con­structed from scratch using the information shown in Figure 13.
Run the Radio Configuration software. Under the
SYSTEM menu, select
RADIO SOFTWARE UPGRADE. Follow the prompts and online instructions
to locate the desired software and complete the upgrade.
The radio’s
PWR LED will flash rapidly to confirm that a download is
in process. The download takes about two minutes.
NOTE: If a software download fails, the radio is left unprogrammed
and inoperative. This is indicated by the PWR LED flashing slowly (1 second on, 1 second off). This condition is only likely if a power failure occurred to the computer or radio during the downloading process. The download can be attempted again when the fault has been corrected.
38 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
5. With a small adjustment tool, adjust each section of the helical filter for maximum RSSI. Re-install the cover to the transceiver.
Invisible place holder
Figure 15. Helical Filter Location
7.5 Upgrading the Radio’s Software
From time to time, new product features or software maintenance files may become available from MDS. This section describes the steps nec­essary to install new software into the transceiver using a PC connected to the radio’s
DIAG. port.
Upgrade software can be obtained in a number of ways. The MDS Web site at www.microwavedata.com contains an FTP area with software files for several radio models. You can browse the listings to see if there are files pertaining to your particular model. There is no charge for this service.
In addition, you can also contact MDS to request radio software. Soft­ware files may be sent to you via e-mail, or on a 3.5” diskette. There may be a nominal charge for the software depending on the nature of the upgrade.
NOTE: Software upgrades are distributed as ASCII files with a “.S28”
extension. These files use the Motorola S-record format.
Using Radio Software Upgrade Diskette
A software upgrade diskette may be purchased from MDS to add new product features to the radio such as Network-wide Diagnostics. The upgrade kit includes a diskette (MDS P/N 06-3501A01) with the most current radio software, authorization codes, and an instruction booklet. Contact MDS for ordering information. When calling, please have the serial number(s) available for the radio(s) that you wish to upgrade.
FRONT PANEL
OF RADIO
J301
U104
U101
U202
HELICAL
ADJUSTMENTS
U203
SHIELD COVER
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 3
Often, a radio system consists of many widely separated remote radios. A point-to-multipoint or SCADA (Supervisory Control and Data Acqui­sition) system may be a new installation for automatic, remote moni­toring of gas wells, water tank levels, electric power distribution system control and measurement, etc.
The radio system may replace a network of remote monitors currently linked to a central location via leased telephone line. At the central office of such a system, there is usually a large mainframe computer and some means of switching between individual lines coming from each remote monitor. In this type of system, there is a modulator/demodulator (modem) at the main computer, and at each remote site, usually built into the remote monitor itself. Since the cost of leasing a dedicated-pair phone line is quite high, radio is often used as an alternative communi­cation medium.
Invisible place holder
Figure 2. Typical MAS Point-to-Multipoint Network
Point-to-Point System
Where permitted, the transceiver may also be used in a point-to-point arrangement. A point-to-point system consists of just two radios—one serving as a master and the other as a remote—as shown in Figure 3. It provides a simplex or half-duplex communications link for the transfer of data between two locations.
Figure 3. Typical Point-to-Point Link
RTU
RTU
RTU
RTU
RTU
REMOTE RADIO
REMOTE RADIO
REMOTE RADIO
REMOTE RADIO
REMOTE RADIO
HOSTSYSTEM
MASTER RADIO
REMOTE
MASTER
HOST
COMPUTER
RTU
4 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
Continuously Keyed vs. Switched Carrier Operation
The keying behavior of the master station can be used to describe an MAS system.
Continuously Keyed operation means the master station transmitter is
always transmitting a carrier, even when there is no data to send. The master station is always simultaneously transmitting and continuously listening. Different frequencies must be used for transmit and receive.
Switched Carrier operation is a half-duplex mode of operation where
the master station transmitter is keyed to send data and unkeyed to receive.
Single Frequency (Simplex) Operation
Single frequency operation (also known as simplex) is a special case of switched carrier operation. Single frequency operation is automatically selected whenever the transmit and receive frequencies are set to the same value. Note that data turn-around times are increased when a single frequency configuration is used.
1.4 Product Configurator Codes
The full radio model number is printed on the radio enclosure. It pro­vides key information about how the radio was configured when it was originally shipped from the factory. See Figure 4 for an explanation of the configurator codes.
Invisible place holder
Figure 4. MDS 1710x/2710x Product Configurator Codes
THIS INFORMATION IS SUBJECT TO CHANGE.
DO NOT
USE FOR
PRODUCT ORDERING.
1710A/C,
OPERATION X= Base/Remote
MODE N= Non-redundant
INPUT VOLTAGE 1= 10.5 to 16 VDC
MODEM B= 9600 bps
DIAGNOSTICS 0= None 1= Network-wide
BANDWIDTH 1= 12.5 kHz 3= 25 kHz
FEATURES 0= Full
AGENCY N= N/A
SAFETY N= N/A
Mtg. Brackets. A= Std. B= None
5= 5 kHz
D= 3200 bps 0= None
C= 19200 bps
RX FRQ. (MHz)
A= 220-240**
A= 130-140
B=140-150 D= 150-165 E= 165-175
TX FRQ. (MHz)
1= 220-240** 2= 140-150 3= 150-165
D= Demo
C= China F= FCC I= Ind. Canada
(6.25 kHz @130-174)
2710A/C/D
4= 165-174
1= 130-140
** MDS 2710A/C Models
A= 220-222*
* MDS 2710D Models
1= 220-222*
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 37
NOTE: It is very important to use attenuation between all units in the
test setup. The amount of attenuation required will depend on the number of units being tested and the desired signal strength (RSSI) at each transceiver during the test. In no case should a signal greater than –50 dBm be applied to any transceiver in the test setup.
Invisible place holder
Figure 14. Typical setup for bench testing of radios
7.4 Helical Filter Adjustment
If the operating frequency of the radio is changed significantly, the helical filters should be adjusted for maximum received signal strength (RSSI). To adjust the filters, proceed as follows:
1. Remove the top cover from the transceiver by loosening the four screws and lifting straight up.
2. Locate the helical lters on the PC board. See Figure 15.
3. Apply a steady signal to the radio at the programmed receive fre­quency (–80 dBm level recommended; no stronger than –60 dBm). This can be done with a signal generator or an over-the-air signal.
4. Measure the radio’s RSSI using one of the following methods:
• With an HHT (See Section 5.0, TRANSCEIVER PROGRAM-
MING on page 17).
• With MDS Radio Configuration Software (See Section 7.5,
Upgrading the Radio’s Software on page 38).
• With a voltmeter connected to Pin 21 of the
DATA INTERFACE
connector (See Section 4.2, RSSI Measurement on page 16).
ANTENNA
13.
8
VDC
+
A
N
TENNA
13.8
VDC
+
ANTENNA
1
3.8
VDC
+
ANTENNA
13.
8
VDC
+
POWER ATTENUATORS
• Fixed or adjustable
• 5W Minimum Rating
POWER DIVIDER
NON-RADIATING ATTENUATOR
• Install on any unused divider ports
• 5W Minimum Rating
COMPUTER RUNNING MDS
"POLL.EXE" PROGRAM
RTU SIMULATORS MDS P/N 03-2512A01*
MASTER STATION
REMOTE
REMOTE
REMOTE
REMOTE
* Transceiver's internal RTU Simulator may be used if external simulator is unavailable. See text.
36 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
3. Program all other radios in the network as nodes by entering the
DTYPE NODE command at each radio.
4. Use the
DLINK ON and DLINK [baud rate] commands to congure the
diagnostic link protocol on the RJ-11 port of each node radio.
5. Connect same-site radios using a null-modem cable at the radios’ diagnostic ports.
6. Connect a PC on which MDS InSite software is installed to the root radio, or to one of the nodes, at the radio’s diagnostic port. (This PC may be the PC being used to collect payload data, as shown in
Figure 12.)
To connect a PC to the radio’s
DIAG. port, an RJ-11 to DB-9 adapter
(MDS P/N 03-3246A01) is required. If desired, an adapter cable may be constructed from scratch using the information shown in
Figure 13.
Invisible place holder
Figure 13. RJ-11 to DB-9 Adapter Cable
7. Launch the MDS InSite application at the PC. (See the MDS InSite User’s Guide for instructions.)
7.3 Bench Testing Setup
Figure 14 shows a sample test setup that can be used to verify the basic
operation of transceivers in a shop setting. The test can be performed with any number of remote radios by using a power divider with the required number of output connections.
The RTU simulator shown in the test setup (MDS Part No. 03-2512A01) is a microcontroller that emulates a remote terminal unit operating at 1200, 2400, 4800, or 9600 bps. Custom software is supplied with the RTU simulator that allows continuous polling of remote radios using an IBM-compatible personal computer. The software reports the number of polls sent, polls received, and the number of errors detected.
As an alternative to using an external RTU simulator, the transceiver’s internal RTU simulator may be used (see
RTU command in Table 7 on
page 20). (This will not provide as conclusive a test as an external sim-
ulator because it does not utilize the transceiver’s data connector.)
RXD
TXD
GND
2
3
5
DB-9 FEMALE
(TO COMPUTER)
TXD
RXD
GND
4
5
6
RJ-11 PLUG (TO RADIO)
RJ-11 PIN LAYOUT
1
6
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 5
1.5 Accessories
The transceiver can be used with one or more of the accessories listed in
Table 2. Contact Microwave Data Systems for ordering information.
2.0 GLOSSARY OF TERMS
If you are new to digital radio systems, some of the terms used in this guide may be unfamiliar. The following glossary explains many of these terms and will prove helpful in understanding the operation of the trans­ceiver.
Active Messaging —This is a mode of diagnostic gathering that may
interrupt SCADA system polling communications (contrast with pas-
sive messaging ). Active (or intrusive) messaging is much faster than
passive messaging because it is not dependent upon the RTU polling cycle.
Table 2. MDS 1710/2710 Series Optional Accessories
Accessory Description MDS P/N
Hand-Held Terminal Kit (HHT)
Terminal that plugs into the radio for programming, diagnostics & control. Includes carrying case, instructions and cable set.
02-1501A01
RTU Simulator Test module that simulates data from a
remote terminal unit. Comes with MDS polling software (02-2093Axx) that runs on a PC. Useful for testing radio operation.
03-2512A01
Order Wire Module External device that allows temporary
voice communication. Useful during setup & testing of the radio system.
02-1297A01
Power Supply Kit AC adaptor that converts 110/220 Vac to
12 Vdc at 30 watts.
01-3682A01
Order Wire Handset Used with Order Wire Module (above). 12-1307A01
RJ-11 to DB-9 Adapter Used to connect a PC to the radio’s
DIAG. port
03-3246A01
EIA-232 to EIA-422 Converter Assembly
External adapter plug that converts the radio’s DATA INTERFACE connector to EIA-422 compatible signaling.
03-2358A01
TTL Converter Assembly
External adapter plug that converts the radio’s DATA INTERFACE connector to TTL compatible signaling.
03-2223A01
Radio Configuration Software
Provides diagnostics of the transceiver (Windows-based PC required.)
03-3156A01
VOX Assembly External unit used to key the radio when
audio input is present.
03-1098A02
19-inch Rack Mounting Kit
Allows mounting the transceiver in a standard 19 inch rack cabinet. (Power supply and Interface Board not included.)
02-1983A02
Brown-Out Protection Board
PCB that protects against low voltage conditions.
03-2567A01
6 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
Antenna System Gain —A figure, normally expressed in dB, repre-
senting the power increase resulting from the use of a gain-type antenna. System losses (from the feedline and coaxial connectors, for example) are subtracted from this figure to calculate the total antenna system gain.
Bit —The smallest unit of digital data, often represented by a one or a
zero. Eight bits (plus start, stop, and parity bits) usually comprise a byte.
Bits-per-second —See BPS .
BPS —Bits-per-second. A measure of the information transfer rate of
digital data across a communication channel.
Byte —A string of digital data usually made up of eight data bits and
start, stop and parity bits.
Decibel (dB)—A measure computed from the ratio between two signal levels. Frequently used to express the gain (or loss) of a system.
Data Circuit-terminating Equipment—See DCE.
Data Communications Equipment—See DCE.
Data Terminal Equipment—See DTE.
dBi—Decibels referenced to an “ideal” isotropic radiator in free space.
Frequently used to express antenna gain.
dBm—Decibels referenced to one milliwatt. An absolute unit used to measure signal power, as in transmitter power output, or received signal strength.
DCE—Data Circuit-terminating Equipment (or Data Communications Equipment). In data communications terminology, this is the “modem” side of a computer-to-modem connection. The transceiver described in this guide is a DCE device.
Digital Signal Processing—See DSP.
DSP—Digital Signal Processing. In the transceiver, the DSP circuitry is
responsible for the most critical real-time tasks; primarily modulation, demodulation, and servicing of the data port.
DTE—Data Terminal Equipment. A device that provides data in the form of digital signals at its output. Connects to the DCE device.
Equalization—The process of reducing the effects of amplitude, fre­quency or phase distortion with compensating networks.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 35
Figure 12 shows an example of a setup for performing network-wide
remote diagnostics from both a Root (master station) location, and a Node (remote station) location.
Invisible place holder
Figure 12. Network-Wide Remote Diagnostics Setup
If a PC is connected to any radio in the network, intrusive polling (polling which briefly interrupts payload data transmission) can be per­formed. To perform diagnostics without interrupting payload data trans­mission, connect the PC to a radio defined as the “root” radio. A radio is defined as a root radio using the
DTYPE ROOT command locally, at the
radio.
A complete explanation of remote diagnostics can be found in MDS’ Network-Wide Diagnostics System Handbook (MDS P/N 05-3467A01). See the Handbook for more information about the basic diagnostic procedures outlined below.
1. Program one radio in the network as the root radio by entering the
DTYPE ROOT command at the radio.
2. At the root radio, use the DLINK ON and DLINK [baud rate] commands to congure the diagnostic link protocol on the RJ-11 port.
RTU
RTU
RTU
MASTER RADIO
DIAGNOSTICS COMPUTER
RUNNING InSite
PAYLOAD DATA
(To SCADA Application)
DIAGNOSTIC DATA
(To InSite)
HOST COMPUTER
NODE
(Supports Intrusive
Diagnostics Only)
ROOT
(Supports Intrusive or
Non-Intrusive Diagnostics)
34 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
RECEIVER
Frequency Range: 130-174 MHz (MDS 1710A/C)
216-220 MHz (MDS 2710 A/C) 220-240 MHz (MDS 2710A/C) 220-222 MHz (MDS 2710D)
See Figure 4 on Page 4 for detailed listing
Type: Double conversion superheterodyne
Frequency Stability: ±1.5 ppm
Maximum Usable Sensitivity: –111 dBm for 1 x 10
-6
BER
Spurious Response Rejection: 70 dB
Intermodulation Response Rejection: 65 dB
Receiver Spurious Conducted Emissions: –57 dBm, 9 kHz to 1 GHz
–47 dBm, 1 GHz to 12.5 GHz
Receiver Spurious Radiated Emissions: –57 dBm, 30 MHz to 1 GHz
–47 dBm, 1 GHz to 12.5 GHz
Bandwidth: 5 kHz (MDS 2710D)
12.5 kHz (MDS 1710A, 2710A) 25 kHz (MDS 1710C, 2710C)
PRIMARY POWER
Voltage: 13.8 Vdc Nominal (10.5 to 16 Vdc)
TX Supply Current: 2.5 amps max RX Supply Current: Operational—150 mA (nominal)
Standby (sleep)—Less than 16 mA (nominal)
Fuse: 4 Amp Polyfuse, Self-Resetting, Internal
(Remove Primary Power to Reset)
Reverse Polarity Protection: Diode across primary input
ENVIRONMENTAL
Humidity: 95% at 40 degrees C
Temperature Range: –30 to 60 degrees C (full performance)
–40 to 70 degrees C (operational)
Weight: 1.6 kilograms
Case: Die-cast Aluminum
DIAGNOSTICS INTERFACE
Signaling Standard: EIA-232
Connector: RJ-11 (may use radio’s DB-25 instead if Pin 23 is
grounded to enable diagnostics channel)
I/O Devices: MDS Hand Held Terminal or PC with MDS software
7.2 Performing Network-Wide Remote Diagnostics
Diagnostics data from a remote radio can be obtained by connecting a laptop or personal computer running MDS InSite diagnostics software to any radio in the network.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 7
Fade Margin—The greatest tolerable reduction in average received signal strength that will be anticipated under most conditions. Provides an allowance for reduced signal strength due to multipath, slight antenna movement or changing atmospheric losses. A fade margin of 20 to 30 dB is usually sufficient in most systems.
Frame—A segment of data that adheres to a specific data protocol and contains definite start and end points. It provides a method of synchro­nizing transmissions.
Hardware Flow Control—A transceiver feature used to prevent data buffer overruns when handling high-speed data from the RTU or PLC. When the buffer approaches overflow, the radio drops the clear-to-send (CTS) line, which instructs the RTU or PLC to delay further transmis­sion until CTS again returns to the high state.
Host Computer—The computer installed at the master station site, which controls the collection of data from one or more remote sites.
Intrusive Diagnostics—A mode of remote diagnostics that queries and commands radios in a network with an impact on the delivery of the system “payload” data. See Active messaging.
Latency—The delay (usually expressed in milliseconds) between when data is applied to TXD (Pin 2) at one radio, until it appears at RXD (Pin 3) at the other radio.
MAS—Multiple Address System. A radio system where a central master station communicates with several remote stations for the pur­pose of gathering telemetry data.
Master (Station)—Radio which is connected to the host computer. It is the point at which polling enters the network.
MCU—Microcontroller Unit. This is the processor responsible for con­trolling system start-up, synthesizer loading, and key-up control.
Microcontroller Unit—See MCU.
Multiple Address System—See MAS.
Network-Wide Diagnostics—An advanced method of controlling and
interrogating MDS radios in a radio network.
Non-intrusive diagnostics—See Passive messaging.
Passive messaging—This is a mode of diagnostic gathering that does
not interrupt SCADA system polling communications. Diagnostic data is collected non-intrusively over a period of time; polling messages are carried with SCADA system data (contrast with active messaging).
8 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
Payload data—This is the application’s user communication data which is sent over the radio network. It is the transfer of payload data that is the primary purpose of the radio communications network.
Point-Multipoint System—A radio communications network or system designed with a central control station that exchanges data with a number of remote locations equipped with terminal equipment.
Poll—A request for data issued from the host computer (or master PLC) to a remote radio.
PLC—Programmable Logic Controller. A dedicated microprocessor configured for a specific application with discrete inputs and outputs. It can serve as a host or as an RTU.
Programmable Logic Controller—See PLC.
Remote (Station)—A radio in a network that communicates with an
associated master station.
Remote Terminal Unit—See RTU.
Redundant Operation—A station arrangement where two transceivers
and two power supplies are available for operation, with automatic switchover in case of a failure.
RTU—Remote Terminal Unit. A data collection device installed at a remote radio site. An internal RTU simulator is provided with the trans­ceiver to isolate faults to either the external RTU or the radio.
SCADA—Supervisory Control And Data Acquisition. An overall term for the functions commonly provided through an MAS radio system.
Standing Wave Ratio—See SWR.
Supervisory Control And Data Acquisition—See SCADA.
SWR—Standing Wave Ratio. A parameter related to the ratio between
forward transmitter power and the reflected power from the antenna system. As a general rule, reflected power should not exceed 10% of the forward power ( 2:1 SWR).
3.0 INSTALLATION
There are three main requirements for installing the transceiver—ade­quate and stable primary power, a good antenna system, and the correct data connections between the transceiver and the data device. Figure 5 shows a typical remote station arrangement.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 33
7.0 TECHNICAL REFERENCE
7.1 Transceiver Specifications
TRANSMITTER SYSTEM SPECIFICATION
Operating Frequency: See Transmitter Specifications
Frequency Stability: ±1.5 ppm
Adjacent Channel Power: –65 dBc (MDS 1710A/2710A)
–60 dBc (MDS 1710C/2710C) –55 dBc (MDS 2710D)
Carrier Power Accuracy: ±2 dB
RECEIVER SYSTEM SPECIFICATION
Operating Frequency: See Receiver Specifications
Maximum Usable Sensitivity: –111 dBm for 1 x 10
-6
BER
Co-Channel Rejection: –12 dB
DATA CHARACTERISTICS
Signaling Standard: EIA-232
Connector: DB-25 Female
Data Interface Rates: 110 bps to 38.4 kbps1200, 2400, 4800, 9600,
19200, 38400 bps—asynchronous
Data Latency: 10 ms maximum, including RTS/CTS delay
Byte Length: 10 or 11 bits
TRANSMITTER
Frequency Range: 130-174 MHz (MDS 1710A/C)
216-220 MHz (MDS 2710 A/C) FCC 220-240 MHz (MDS 2710A/C) 220-222 MHz (MDS 2710D) FCC
See Figure 4 on Page 4 for detailed listing
Modulation Type: Binary CPFSK
Carrier Power: 0.1 Watts to 5 Watts @13.8 Vdc
Duty Cycle: Continuous
Output Impedance: 50 ohms
Frequency Stability: MDS 1710 ±1.0 ppm
MDS 2710 ±1.5 ppm
Channel Spacing: 6.25 kHz steps (MDS 1710A/C and 2710A/C)
5.0 kHz steps (MDS 2710D)
6.25 kHz (MDS 1710A/C @ 130-174 MHz)
Transmitter Spurious Radiated Emissions: –57 dBm, 30 MHz to 1 GHz
–47 dBm, 1 GHz to 12.5 GHz
Harmonics:
2nd harmonic: 57 dBc
3rd harmonic & higher: 57 dBc
Time-out Timer: 30 seconds (default). Selectable with TOT
command
Transmitter Keying: Data activated or RTS
32 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
Minor Alarms—report conditions that, under most circumstances will not prevent transceiver operation. This includes out-of-tolerance condi­tions, baud rate mismatches, etc. The cause of these alarms should be investigated and corrected to prevent eventual system failure.
Event Code Definitions
Table 8 contains a listing of all event codes that may be reported by the
transceiver.
Table 8. Event Codes
Event Code
Event Class Description
01 Major Improper software detected for this radio model.
02 Major The model number of the transceiver is unprogrammed.
04 Major One or both of the internal programmable synthesizer loops is
reporting an out-of-lock condition.
06 Major An unrecoverable fault was detected on the A-to-D chip. The
radio will not receive data.
07 Major One or more of the radio’s internal voltage regulators is
reporting a failure. The radio will not operate.
08 Major The system is reporting that it has not been calibrated. Factory
calibration is required for proper radio operation.
09 -- Not used.
10 Major The internal microcontroller was unable to properly program
the system to the appropriate EEPROM defaults. A hardware problem may exist.
11 -- Not used.
12 Major Receiver time-out. No data received within the specified
receiver time-out time.
13 Major Transmitter time-out. The radio was keyed for a duration
exceeding the time-out timer setting. (This alarm clears the next time the radio keys.)
14–15 -- Not used.
16 Minor Not used.
17 Minor A data parity fault has been detected on the DATA
INTERFACE connector. This usually indicates a parity setting mismatch between the radio and the RTU.
18 Minor A data framing error has been detected on the DATA
INTERFACE connector. This may indicate a baud rate mismatch between the radio and the RTU.
19–24 -- Not used.
25 Minor The 5.6 volt power regulator is out-of-tolerance. If the error is
excessive, operation may fail.
26 Minor The DC input voltage is out-of-tolerance. If the voltage is too
far out of tolerance, operation may fail.
27, 28 -- Not used
31 Minor The transceiver’s internal temperature is approaching an
out-of-tolerance condition. If the temperature drifts outside of the recommended operating range, system operation may fail.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 9
Invisible place holder
Figure 5. Typical Remote Station Arrangement
3.1 Installation Steps
Below are the basic steps for installing the transceiver. In most cases, these steps alone are sufficient to complete the installation. More detailed explanations appear at the end of these steps.
1. Mount the transceiver to a stable surface using the brackets supplied with the radio.
2. Install the antenna and antenna feedline for the station. Preset direc­tional antennas in the desired direction.
3. Connect the data equipment to the transceiver’s
DATA INTERFACE
connector. Use only the required pins for the application—Do not use a fully pinned (25 conductor) cable. Basic applications may require only the use of Pin 2 (transmit data—TXD), Pin 3 (Received Data—RXD) and Pin 7 (signal ground). The radio can be keyed with the use of the
DATAKEY command.
Additional connections may be required for some installations. Refer to the complete list of pin functions provided in Table 4 on
page 14.
4. Measure and install the primary power for the radio. The red wire on the power cable is the positive lead; the black is negative.
13.8 VDC POWER
CABLE
13.8 VDC
2.5 A (Minimum) POWER SUPPLY
REMOTE TERMINAL UNIT
ANTENNA SYSTEM
LOW-LOSS FEEDLINE
RADIO
TRANSCEIVER
10 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
NOTE: Use the radio in negative ground systems only.
5. Set the radio conguration. The transceiver is designed for quick installation with a minimum of software conguration required in most cases. The selections that must be made or veried for new installations are:
• Transmit frequency
• Receive frequency
The operating frequencies are not set at the factory unless they were specied at the time of order. Determine the transmit and receive frequencies to be used, and follow the steps below to program them.
6. Connect a hand-held terminal (HHT) to the
DIAG. connector. When
the HHT beeps, press to receive the ready “>” prompt.
• Set the operating frequencies using the
TX xxx.xxxxx (transmit) and
RX xxx.xxxxx (receive) commands.
• Press after each command. After programming, the HHT reads PROGRAMMED OK to indicate successful entry.
• Set other transceiver parameters as required. A complete list of transceiver commands is provided in Section 5.0, TRANSCEIVER
PROGRAMMING.
ENTER
ENTER
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 31
• The correct interface between the transceiver and the connected data equipment (correct cable wiring, proper data format, timing, etc.)
6.1 LED Indicators
The LED status indicators are an important troubleshooting tool and should be checked whenever a problem is suspected. Table 5 on page 16 describes the function of each status LED.
6.2 Event Codes
When an alarm condition exists, the transceiver creates a code that can be read on an HHT connected to the
DIAG. port. These codes can be very
helpful in resolving many system difficulties. Refer to Table 8 for a def­inition of the event codes.
Checking for Alarms—STAT command
To check for alarms, enter
STAT on the HHT. If no alarms exist, the mes-
sage
NO ALARMS PRESENT appears at the top of the display (Figure 11).
Invisible place holder
Figure 11. HHT Display in Response to STAT Command
If an alarm does exist, a two-digit alarm code (00–31) is displayed and the event is identified as a Major or Minor Alarm. A brief description of the alarm is also given.
If more than one alarm exists, the word
MORE appears at the bottom of
the screen. To view additional alarms, press .
Major Alarms vs. Minor Alarms
Major Alarms—report serious conditions that generally indicate a hard­ware failure, or other abnormal condition that will prevent (or seriously degrade) further operation of the transceiver. Major alarms generally indicate the need for factory repair. Contact MDS for further assistance.
ENTER
30 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
TOT [1-255, ON, OFF]
This command sets or displays the transmitter Time-out Timer value (1–255 seconds), as well as the timer status (
ON or OFF). If the timer is
on, and the radio remains keyed for a longer duration than the
TOT value,
the transmitter is automatically unkeyed.
When this happens, the radio must be commanded back to an unkeyed state before a new keying command is accepted. The default timer value is 30 seconds.
TX [xxx.xxxxx]
This command selects or displays the radio’s transmit frequency in MHz. The frequency step size is 6.25 kHz for the MDS 2710A/C and
5.0 kHz for the MDS 2710D.
If the customer frequency has not been programmed at the factory, a default frequency will be programmed in the radio near the center of the frequency band.
UNIT [10000...65000]
This command selects or displays the radio’s unit address. The factory default setting is the last four digits of the transceiver’s serial number. The unit address is used in network diagnostics. See MDS’ Net­work-Wide Diagnostics System Handbook (MDS P/N 05-3467A01) for more information.
6.0 TROUBLESHOOTING
Successful troubleshooting of the radio system is not difficult, but it requires a logical approach. It is best to begin troubleshooting at the master station, as the rest of the system depends on the master for polling commands. If the master station has problems, the operation of the entire network can be compromised.
It is good practice to start by checking the simple things. For proper operation, all radios in the network must meet these basic requirements:
• Adequate and stable primary power. The radio contains an inter­nal self-resetting fuse (4A). Remove and re-apply primary power to reset.
• Secure connections (RF, data and power)
• An efficient and properly aligned antenna system with a good received signal strength (at least –90 dBm). It is possible for a system to operate with weaker signals, but reliability will be degraded.
• Proper programming of the transceiver’s operating parameters (see Section 5.0, TRANSCEIVER PROGRAMMING).
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 11
3.2 Transceiver Mounting
Figure 6 shows the mounting dimensions of the transceiver.
Invisible place holder
Figure 6. Transceiver Mounting Dimensions
3.3 Antennas and Feedlines
Antennas
The transceiver can be used with a number of antennas. The exact style depends on the physical size and layout of the radio system. A direc­tional Yagi (Figure 7) or corner reflector antenna is generally recom­mended at remote sites to minimize interference to and from other users. Antennas of this type are available from several manufacturers.
8.5"
216 mm
1.75"
4.44 CM
6.63"
168 mm
2.75" 70 mm
7.25" 184 mm
ALTERNATE
POSITION
5.625"
143 mm
2.25" 57 mm
2.0" 50 mm
12 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
Invisible place holder
Figure 7. Typical Yagi Antenna (mounted to mast)
Feedlines
The selection of antenna feedline is very important. Poor quality cables should be avoided as they will result in power losses that may reduce the range and reliability of the radio system.
Table 3 shows the losses that will occur when using various lengths and
types of cable at 200 MHz. Losses at 130-174 MHz will be slightly lower. Regardless of the type of cable used, it should be kept as short as possible to minimize signal loss
† Cable loss slightly lower at 130-174 MHz.
3.4 Power Connection
The transceiver can be operated from any well-filtered 10.5 to 16 Vdc power source. The power supply should be capable of providing at least
2.5 amperes of continuous current.
The red wire on the power cable is the positive lead; the black is nega­tive.
NOTE: The radio is designed for use only in negative ground systems.
Table 3. Length vs. Loss in Coaxial Cables at 200 MHz
Cable Type
3 Meters
(10 Feet)
15 Meters
(46 Feet)
30 Meters
(91 Feet)
150 Meters
(525 Feet)
RG-8A/U 0.32 dB 1.6 dB 3.2 dB 16 dB
1/2 inch HELIAX
0.10 dB 0.49 dB 0.98 dB 4.9 dB
7/8 inch HELIAX
0.05 dB 0.27 dB 0.54 dB 2.7 dB
1-1/4 inch HELIAX
0.04 dB 0.20 dB 0.40 dB 2.0 dB
1-5/8 inch HELIAX
0.03 dB 0.17 dB 0.33 dB 1.65 dB
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 29
SHOW [DC, PORT, PWR]
The
SHOW command displays different types of information based on
the command variables. The different parameters are:
DC—Display DC input/output voltages
PORT—Display the connector port (RJ-11 or DB-25) that is active
for diagnostics and control.
PWR—Display RF power output
SNR
This command continuously displays the signal-to-noise ratio of the received signal expressed in dB, until you press the Enter key. As used in this guide, the signal-to-noise measurement is based upon the signal level following equalization, for received frames.
The SNR is an indication of the received signal quality. The SNR indi­cation ranges from 10 dB to 33 dB. A value of 10 dB represents a very poor signal. A value of 24 dB represents a very good signal.
When the SNR command is used, it causes the
DIAG. port to enter an
update mode, and the signal-to-noise ratio is updated and redisplayed every 2 seconds. The SNR continuously updates until the key is pressed.
SREV
This command displays the software revision level of the transceiver firmware.
STAT
This command displays the current alarm status of the transceiver.
If no alarms exist, the message
NO ALARMS PRESENT appears at the top
of the HHT display.
If an alarm does exist, a two-digit code (00–31) is displayed and the alarm is identified as “Major” or “Minor.” A brief description of the alarm code is also given.
If more than one alarm exists, the word
MORE appears at the bottom of
the screen and additional alarms are viewed by pressing the key. Detailed descriptions of event codes are provided in Table 8 on
page 32.
TEMP
This command displays the internal temperature of the transceiver in degrees Celsius.
ENTER
ENTER
28 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
RSSI
This command continuously displays the radio’s Received Signal Strength Indication (RSSI) in dBm units, until you press the Enter key. Incoming signal strengths from –50 dBm to –120 dBm can be read.
RTU [ON/OFF/0-80]
This command re-enables or disables the radio’s internal RTU simu­lator, which runs with MDS’ proprietary polling programs (poll.exe and rsim.exe). The internal RTU simulator is available whenever a radio has diagnostics enabled. This command also sets the RTU address that the radio will respond to.
The internal RTU can be used for testing system payload data or pseudo bit error rate testing. It can also be helpful in isolating a problem to either the external RTU or the radio.
RX [xxx.xxxxx]
This command selects or displays the radio’s receive frequency in MHz. The frequency step size is 6.25 kHz for the MDS 2710A/C and 5.0 kHz for the MDS 2710D.
If the customer frequency has not been programmed at the factory, a default frequency will be programmed in the radio near the center of the frequency band.
RXTOT [NONE, 1-255]
The
RXTOT command selects or displays the receive time-out timer value
in minutes. This timer triggers an alarm (event 12) if data is not detected within the specified time.
Entering the
RXTOT command without a parameter displays the timer
value in minutes. Entering the
RXTOT command with a parameter
ranging from 0 to 255 resets the timer in minutes. Entering the
RXTOT
command with the parameter
NONE disables the timer.
SCD [0-255]
This command displays or changes the soft-carrier dekey delay in milli­seconds.
This timer specifies how long to wait after the removal of the keying signal before actually releasing the transmitter. A value of 0 millisec­onds will unkey the transmitter immediately after the removal of the keying signal.
SER
This command displays the radio’s serial number as recorded at the fac­tory.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 13
3.5 Data Interface Connections
The transceiver’s DATA INTERFACE connector is used to connect the transceiver to an external DTE data terminal that supports the EIA-232 (formally RS-232) format. The transceiver supports asynchronous data rates of up to 38400 bps. The data rate at the
DATA INTERFACE connector
may differ from the data rate used over the air.
Table 4 lists each pin on the
DATA INTERFACE connector and describes
its function.
Do not use a 25 wire (fully pinned) cable for connection to the
DATA
INTERFACE
connector. Use only the required pins for the application. Damage may result if improper connections are made. Typical applica­tions require the use of only Pins 1 through 8 for EIA-232 signaling.
3.6 Using the Radio’s Sleep Mode
In some installations, such as at solar-powered sites, it may be necessary to keep the transceiver’s power consumption to an absolute minimum. This can be accomplished using the Sleep Mode. In this mode, power consumption is reduced to less than 16 milliamperes (nominal).
Sleep mode can be enabled under RTU control by asserting a ground (or EIA-232 low) on Pin 12 of the radio’s
DATA INTERFACE connector.
When Pin 12 is opened (or an EIA-232 high is asserted), the radio will be ready to receive data within 75 milliseconds.
All normal functions are suspended while the radio is in sleep mode. The
PWR LED will be off, except for a quick flash every 5 seconds.
Sleep Mode Example
The following example describes Sleep Mode implementation in a typ­ical system. Using this information, you should be able to configure a system that will meet your own particular needs.
Example:
Suppose you need communications to each remote site only once per hour. Program the RTU to raise an EIA-232 line once each hour (DTR for example) and wait for a poll and response before lowering it again. Connect this line to Pin 12 of the radio’s
DATA INTERFACE connector. This will allow each RTU to
be polled once per hour with a significant savings in power con­sumption.
CAUTION
USE
ONLY REQUIRED
PINS
14 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
Table 4. DATA INTERFACE Connector Pinouts
Pin Number
Input/ Output Pin Description
1--Protective Ground. Connects to ground (negative supply
potential) on the radio’s PC board and chassis.
2INTXD—Transmitted Data. Accepts TX data from the
connected device.
3 OUT RXD—Received Data. Outputs received data to the
connected device.
4INRTS—Request-to-Send Input. Keys the transmitter when
RTS is at logic high.
5 OUT CTS—Clear-to-Send Output. Goes “high” after the
programmed CTS delay time has elapsed (DCE) or keys an attached radio when RF data arrives (CTS KEY).
6 OUT DSR—Data Set Ready. Provides a +6 Vdc DSR signal
through a 2.5 k resistor.
7--Signal Ground. Connects to ground (negative supply
potential) at radio’s PC board.
8 OUT DCD—Data Carrier Detect. Goes “high” when the modem
detects a data carrier from the master station.
9INTransmit Audio Input. Connects to the audio output of an
external (AFSK) modem. The input impedance is 600 . Use Pin 7 for the modem’s return lead.
10 OUT RUS—Receiver Unsquelched Sensor. Not used in most
installations, but is available as a convenience. Provides +8 Vdc through a 1 k resistor whenever the receiver squelch is open, and drops to less than 1 Vdc when the squelch is closed.
11 OUT Receive Audio Output. Connects to the audio input of an
external (AFSK) modem. The output impedance is 600 Ω, and the level is factory set to suit most installations. Use Pin 7 for the modem’s return lead.
12 IN Radio Inhibit (Sleep). A ground on this pin places the
radio into the “sleep” mode. It turns off most circuits in the radio, including transmit, receive, modem and diagnostic functions. This allows for greatly reduced power consumption, yet preserves the radio’s ability to be quickly brought online.
13 -- Do not connect—Reserved for future use.
14 IN PTT—Push to Talk. This line is used to key the radio with
an active-high signal of +5 Vdc.
15 OUT Remote RTU Reset. Do not connect—Reserved for future
use.
16 IN PTT
—Push to Talk. This line is used to key the radio with
an active-low signal of 0 Vdc.
17 -- Do not connect—Reserved for future use.
18 IN/OUT Accessory Power. Unregulated Input/Output. Provides a
source of input power for low current accessories. Excessive drain on this connection will trip self-resetting fuse F1 on the transceiver PC board. The voltage at this pin will match the input voltage to the transceiver.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 27
KEY
This command activates the transmitter. See also the
DKEY command.
MODEL
This command displays the radio’s model number code.
MODEM [xxxx, NONE]
This command selects the radio’s modem characteristics. Enter 9600 or 3200 for digital operation, or enter NONE to select analog operation. For MDS 1710 digital operation the proper settings are
9600 for the MDS
2710A,
19200 for the MDS 1710C.
For MDS 2710 operation, the proper settings are
3200 for the MDS
2710D,
9600 for the MDS 2710A, and 19200 for the MDS 2710C.
OWM [XXX...]
This is a command to display or program an owner’s message. To pro­gram the owner’s message, type
OWM then the message, followed by
.
To display the owner’s message, type
OWM then . The owner’s
message appears on the display.
OWN [XXX...]
This is a command to display or program an owner’s name. To program the owner’s name, type
OWN then the name, followed by .
To display the owner’s name, type OWN then . The owner’s name appears on the display.
PTT [0–255]
This command sets or displays the key-up delay in milliseconds.
This timer specifies how long to wait after the radio receives a key signal from either the PTT or RTS lines (on the
DATA INTERFACE), before actu-
ally keying the radio.
PWR [20–37]
NOTE: This function may not be available, depending on certification
requirements in a particular country.
This command displays or sets the desired RF forward output power set­ting of the radio. The
PWR command parameter is specified in dBm and
can range from 20 through 37. The default setting is 37 dBm (5 watts). To read the actual (measured) power output of the radio, use the
SHOW
PWR
command. A dBm-to-watts conversion chart is provided in
Section 7.6.
ENTER
ENTER
ENTER
ENTER
26 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
DUMP
This command displays all the programmed settings of the radio. The HHT display is too small to list all the command settings at one time. Therefore, this command is most useful if the command is issued from a computer or full-screen terminal.
HREV
This command displays the transceiver’s hardware revision level if it has been programmed at the factory.
INIT
The
INIT command is used to re-initialize the radio’s operating parame-
ters to the factory defaults. This may be helpful when trying to resolve configuration problems that may have resulted from the entry of one or more improper command settings. Entry of this command allows you to get back to a known working state. The following changes to the radio are made when
INIT is entered:
CTS is set to 0
DATAKEY is set to ON
DEVICE is set to DCE
PTT is set to 0
SCD is set to 0
TOT is set to 30 seconds and set to ON
PWR is set to +37 dBm (5 watts)
All other commands stay at their previously established settings.
INIT [2710]
This command sets the transceiver for operation outside the MDS model P-20 chassis by setting the following parameters as shown.
ASENSE ACTIVE HI
AMASK FFFF FFFF
(assert alarm output on all alarms)
RXTOT NONE (receive time-out timer disabled)
This command can be used subsequent to using the
INIT 2720 command
to restore the standard transceiver defaults.
INIT [2720]
This command sets the transceiver for operation inside the model P-20 chassis by setting the following parameters as shown.
ASENSE ACTIVE LO
AMASK FFFF 0000
(trigger on major alarms)
RXTOT 20 (20 minute time-out timer)
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 15
Invisible place holder
4.0 OPERATION
In-service operation of the transceiver is completely automatic. Once the unit has been properly installed and configured, operator actions are limited to observing the front panel LED status indicators for proper operation.
If all parameters are correctly set, operation of the radio can be started by following these steps:
1. Apply DC power to the transceiver.
2. Observe the LED status panel for the proper indications (Table 5).
3. If not done earlier, rene the antenna heading of the station to maxi-
mize the received signal strength (RSSI) from the master station.
Use the
RSSI command from an HHT connected to the radio’s DIAG.
connector.—See Section 5.0, TRANSCEIVER PROGRAMMING. This can also be done with a DC voltmeter as described in
Section 4.2, RSSI Measurement.
19 OUT 9.9 Vdc Regulated Output. Provides a source of
regulated voltage at 100 mA for low power accessories.
20 -- Do not connect—Reserved for future use.
21 OUT RSSI—Received Signal Strength Indication. A DC
voltmeter may be connected to this pin to read the relative strength of the incoming signal. Figure 8 is a chart showing RSSI vs. DC voltage.
22 -- Do not connect—Reserved for future use.
23 IN Diagnostic Channel Enable. A ground on this pin causes
the radio’s microcontroller to open the DB-25 DATA INTERFACE for diagnostics and control instead of the normal RJ-11 DIAG. connection.
24 -- Do not connect—Reserved for future use.
25 OUT Alarm. A logic low (less than 0.5 volts) on this pin indicates
normal operation. A logic high (greater than 4 volts) indicates that some alarm condition is present. This pin can be used as an alarm output, provided the internal series resistance of 1 k is considered.
Table 4. DATA INTERFACE Connector Pinouts (Continued)
Pin Number
Input/ Output Pin Description
16 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
4.1 LED Indicators
Table 5 describes the function of each status LED.
4.2 RSSI Measurement
As an alternative to using an HHT, the radio’s received signal strength (RSSI) may be read with a DC voltmeter connected to Pin 21 of the
DATA
INTERFACE connector. Figure 8 shows the relationship between
received signal level and the DC voltage on Pin 21 of the
DATA INTER-
FACE connector. (Note: Readings are not accurate for signals stronger
than –50 dBm.)
Invisible place holder
Figure 8. RSSI vs. Vdc (Typical)
PWR DCD TXD RXD
Table 5. LED Status Indicators
LED Name Description
PWR • Continuous—Power is applied to the radio, no problems detected.
• Rapid flash (five times-per-second)—Fault indication.
• Flashing once every 5 seconds—Radio is in Sleep mode.
DCD • Flashing—Indicates the radio is receiving intermittent data frames.
• Continuous—Radio is receiving a data signal from a continuously keyed radio.
TXD An EIA-232 mark signal is being received at the DATA INTERFACE
connector.
RXD An EIA-232 mark signal is being sent out from the DATA INTERFACE
connector.
2
2.5
3
3.5
4
–110
–90
–70
–50
+ DC VOLTS (PIN 21)
SIGNAL LEVEL (dBm)
4.5
5.0
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 25
The default selection is DCE. In this mode, CTS will go high following RTS, subject to the CTS programmable delay time. If the
DATAKEY com-
mand is set to
ON, keying can be stimulated by the input of characters at
the data port. Hardware flow control is implemented by signaling the CTS line if data arrives faster than it can be buffered and transmitted.
If
CTS KEY is selected, the radio is assumed to be controlling another
radio. The RTS line is ignored and the CTS line is used as a keyline con­trol for the other radio. CTS is asserted immediately following the receipt of RF data, but data will not be sent out the
DATA INTERFACE port
until after the CTS programmable delay time has expired. (This gives the other radio time to key.)
DKEY
This command deactivates the transmitter after it has been keyed with the KEY command.
DLINK [ON/OFF/xxxx]
This command is used to configure the local diagnostic link protocol used in network-wide diagnostics.
Entering
DLINK ON enables the diagnostic link. Entering DLINK OFF dis-
ables the diagnostic link.
To change the diagnostic link, enter
DLINK followed by one of the fol-
lowing baud rates: 1200, 2400, 4800, 9600, 19200 (default).
DMGAP [xx]
The DMGAP command sets the amount of time in milliseconds to wait after the receipt of a character before interpreting the next received char­acter as the start of a new message. When data port baud rates are slow, the gap between characters within a poll may be so long that the radio interprets the next character as the start of a new poll. When diagnostics is being performed using passive messaging (see Performing Net-
work-Wide Remote Diagnostics on page 34), this command may be used
to change this behavior.
DTYPE [NODE/ROOT]
This command establishes the local radio as a root radio or node radio for network-wide diagnostics. Entering
DTYPE NODE configures the
radio as a node radio. Entering
DTYPE ROOT configures the radio as a root
radio. Entering the
DTYPE command alone displays the current setting.
See “Performing Network-Wide Remote Diagnostics” on page 34. Two associated commands are
GATE and PEER. See MDS’ Network-Wide
Diagnostics System Handbook (MDS P/N 05-3467A01) for details.
24 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
If data buffering is ON, the radio operates in seamless mode. Data bytes will be sent over the air as quickly as possible, but the receiver buffers (stores) the data until enough bytes have arrived to cover worst-case gaps in transmission. This mode of operation is required for protocols such as MODBUS™ that do not allow gaps in their data transmission.
Note that seamless mode (
BUFF ON) is intended only for applications
where the transmitter’s baud rate is greater than or equal to the receiver’s baud rate. Adherence to this rule is left up to the user.
CKEY [ON–OFF]
The
CKEY command enables or disables the continuously-keyed func-
tion of the radio. When
CKEY is set to ON, the radio is continuously
keyed.
CTS [0–255]
The
CTS (clear-to-send) command selects or displays the timer value
associated with the CTS line response. The command parameter ranges from 0 to 255 milliseconds.
For DCE operation, the timer specifies how long to wait after the RTS line goes high, before the radio asserts CTS and the DTE can transmit the data. A CTS value of zero keys the radio and asserts the CTS line immediately after the RTS line goes high.
For CTS Key operation (see
DEVICE command), the timer specifies how
long to wait after asserting the CTS, before sending data out the
DATA
INTERFACE port. A timer value of zero means that data will be sent out
the data port without imposing a key-up delay. (Other delays may be present based on selected radio operating parameters.)
DATAKEY [ON, OFF]
The
DATAKEY command sets or displays the ability of the radio to key the
transmitter as data is received at the
DATA INTERFACE connector.
Asserting RTS keys the radio regardless of this command setting.
If
DATAKEY is set to ON, the radio will key when a full data-character is
received at the transceiver’s
DATA INTERFACE connector. If DATAKEY is
set to
OFF, the radio needs to be keyed by asserting either the RTS or
PTT signal or with the
CKEY or KEY command.
DEVICE [DCE, CTS KEY]
The
DEVICE command sets or displays the device behavior of the radio.
The command parameter is either
DCE or CTS KEY.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 17
5.0 TRANSCEIVER PROGRAMMING
Programming and control of the transceiver is performed through the radio’s RJ-11
DIAG. (Diagnostics) connector with an MDS Hand-Held
Terminal (MDS P/N 02-1501A01). This section contains a reference chart (Table 7) followed by detailed descriptions for each user com­mand.
NOTE: In addition to HHT control, Windows-based software is avail-
able (MDS P/N 03-3156A01) to allow diagnostics and programming using a personal computer. An installation booklet and on-line instructions are included with the soft­ware. Contact MDS for ordering information.
5.1 Hand-Held Terminal Connection & Startup
This section gives basic information for connecting and using the MDS Hand-Held Terminal. For more information about the terminal, refer also to the instructions included with each HHT kit.
The steps below assume that the HHT has been configured for use with the transceiver (80 character screen display). If the HHT was previously used with a different model transceiver, or if its default settings have been changed, refer to Section 5.2, Hand-Held Terminal Setup for setup details.
Follow these steps to connect the HHT:
1. Connect the HHT’s coiled cord to the
DIAG. (RJ-11) jack on the
radio as shown in Figure 9. This automatically places the radio into the control and programming mode.
As an alternative, the
DATA INTERFACE (DB-25) connector may be
used for programming instead of the
DIAG. jack. With this arrange-
ment, Pin 23 of the HHT cable must be grounded to enable the diag­nostic channel. (See Table 4.)
2. When the HHT is connected, it runs through a brief self-check, ending with a beep. After the beep, press to obtain the ready “>” prompt.
ENTER
18 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
Invisible place holder
Figure 9. Hand-Held Terminal Connected to the Transceiver
5.2 Hand-Held Terminal Setup
The following is a set of instructions for re-initializing an HHT for use with the transceiver. These steps may be required if the HHT was previ­ously used with a different radio, or if the HHT default settings have been inadvertently altered.
1. Plug the HHT into the
DIAG. connector. Enable the setup mode by
pressing the , and keys in sequence. The display shown in Figure 10 appears.
Invisible place holder
Figure 10. HHT Setup Display
2. The rst of 15 menu items is displayed. Settings are reviewed by pressing the NEXT function controlled by the key. P arameter set-
tings are changed by pressing the ROLL function controlled by the
key.
ANTENNA
13.8 VDC
+
Z
CTRL
U
+
K
*
F
/
A
F1
V
,
Q
#
)
G
(
B
F2
SHIFT
ESC
W
=
R
7
M
4
H
1
C
F3
BKSP
X
0
S
8
N
5
I
2
D
F4
SP
ACE
Y
T
9
O
6
3
E
F5
ENTER
J
L
P
SHIFT
CTRL
SPACE
FF1FFF
B
C
D
E
A
E
A
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 23
Each bit that is a ‘1’ identifies an associated alarm condition that can trigger the alarm output status line. Each bit that is a ‘0’ treats the asso­ciated alarm as irrelevant when deciding whether or not to assert the alarm output status line. For more information on tailoring the alarm response, contact the MDS Technical Services Department.
ASENSE [HI/LO]
The
ASENSE command sets or displays the sense of the alarm output at
Pin 25 of the
DATA INTERFACE connector.
Entering the
ASENSE command alone shows whether the alarm output is
active high or low. Entering the
ASENSE command followed by HI or LO
resets the alarm output to active high or low.
BAUD [xxxxx abc]
This command sets (or displays) the communication attributes for the
DATA INTERFACE port. It has no effect on the RJ-11 DIAG. port.
The first parameter (
xxxxx) is baud rate. Baud rate is specified in
bits-per-second (bps) and must be one of the following speeds: 110, 300, 1200, 2400, 4800, 9600, 19200, or 38400.
The second parameter of the
BAUD command (abc) is a three-character
block indicating how the data is encoded:
a = Data bits (7 or 8) b = Parity (N for None, O for Odd, E for Even) c = Stop bits (1 or 2)
The factory default setting is 4800 baud, 8 data bits, no parity, 1 stop bit (Example:
4800 8N1).
NOTE: 7N1, 8O2, and 8E2 are invalid communication settings and are
not supported by the transceiver.
BUFF [ON, OFF]
This command sets or displays the received data handling mode of the radio. The command parameter is either
ON or OFF. The default is ON.
The setting of this parameter affects the timing of how received RF data is sent out the
INTERFACE connector. Outgoing (transmitted) data is not
affected by this setting.
If data buffering is
OFF, the radio operates with the lowest possible
average latency. Data bytes are thus sent out the
INTERFACE port as soon
as an incoming RF data frame is disassembled. Average and typical latency will both be below 10 ms, but idle character gaps may be intro­duced into the outgoing data flow.
22 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
5.4 Detailed Command Descriptions
The only critical commands for most applications are transmit and receive frequencies (
RX xxx.xxxxx, TX xxx.xxxxx). However, proper use of
the additional commands allows you to tailor the transceiver for a spe­cific use, or conduct basic diagnostics on the radio. This section gives more detailed information for the user commands previously listed in
Table 7.
In many cases, the commands shown here can be used in two ways. First, you can type only the command name to view the currently pro­grammed data. Secondly, you can set or change the existing data by typing the command, followed by a space, and then the desired entry. In the list below, allowable programming variables, if any, are shown in brackets following the command name.
AMASK [0000 0000–FFFF FFFF]
The
AMASK (alarm mask) command displays or sets which events cause
the alarm output signal to be active. Normally, the mask is
FFFF FFFF,
meaning that any of the 32 possible events will activate the alarm output signal. No special configuration is required for typical applications.
Entering the
AMASK command alone displays the current setting of
alarm events in hexadecimal format.
Entering the
AMASK command followed by an eight-digit hexadecimal
number reprograms the specified events to trigger an alarm.
The eight-digit hexadecimal number used as the command parameter is used to classify up to 32 events as alarm triggers for the alarm output status line. (See Table 8 on page 32 for a list of event codes.) The hex value for the mask corresponds to the hex value for the
STAT command
(see the
STAT command description).
TEMP
Details page 29
Display the internal temperature of the radio in degrees Celsius.
TOT [1-255, ON, OFF]
Details page 30
Set or display the Time-out Timer delay in seconds.
TX [xxx.xxxxx]
Details page 30
Set or display the transmit frequency.
UNIT [10000...65000]
Details page 30
Set or display the transceiver’s unit address.
Table 7. Command summary (Continued)
Command name Function
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 19
3. Set up the HHT as listed in Table 6.
5.3 Keyboard Commands
Table 7 is a reference chart of software commands for the transceiver.
Programmable information is shown in brackets [ ] following the com­mand name. See Section 5.4, Detailed Command Descriptions for detailed command descriptions.
Entering Commands
To enter a command, type the command, followed by an key­stroke. For programming commands, the command is followed by
and the appropriate information or values, then
.
Here are some additional points to remember when using the HHT:
• Use the key to access numbers; press again to return to letter mode.
• Use the key to edit information or commands entries.
• The flashing square cursor ( ) indicates that letter mode is selected.
• The flashing superscript rectangular cursor ( ) indicates that number mode is selected.
Error Messages
Listed below are some possible error messages that may be encountered when using the HHT:
UNKNOWN COMMAND—The command was not recognized. Refer to the
command description for command usage information.
INCORRECT ENTRY—The command format or its associated values were
not valid. Refer to the command description for command usage infor­mation.
Table 6. HHT Operational Settings
Parameter Setting Parameter Setting
Re-init HT NO Scroll On 33rd
Baud Rate 9600 Cursor ON
Comm bits 8,1,n CRLF for CR OFF
Parity Error OFF Self Test FAST
Key Repeat OFF Key Beep ON
Echo OFF Screen Size 80
Shift Keys YES Menu Mode LONG
Ctl Chars PROCS
ENTER
SPACE
ENTER
SHIFT
ESC/BKSP
20 MDS 1710A/C and MDS 2710A/C/D MDS 05-3447A01, Rev. F
COMMAND FAILED—The command was unable to successfully complete.
This may indicate an internal software problem.
NOT PROGRAMMED—Software was unable to program the internal radio
memory or the requested item was not programmed.This is a serious internal radio error. Contact MDS for assistance.
TEXT TOO LONG—Response to OWN or OWM command when too many
characters have been entered. Refer to the command description for command usage information.
NOT AVAILABLE—The entered command or parameter was valid, but it
referred to a currently unavailable choice. Refer to the command description for command usage information.
ACCESS DENIED—The command is unavailable to the user. Refer to the
command descriptions for command information.
EEPROM FAILURE— The INIT command was unable to write to EEPROM.
This is a serious internal radio error. Contact MDS for assistance.
Table 7. Command summary
Command name Function
AMASK [0000
0000–FFFF FFFF]
Details page 22
Set or display hex code identifying which events trigger an alarm.
ASENSE [HI/LO]
Details page 23
Set or display the state of the alarm output signal to ACTIVE HI or ACTIVE LO.
BAUD [xxxxx abc]
Details page 23
Set or display the DATA INTERFACE data rate and control bits.
BUFF [ON, OFF]
Details page 23
Enables or disables the internal radio data buffer.
CTS [0–255]
Details page 24
Set or display the Clear-to-Send delay in seconds.
CKEY [ON–OFF]
Details page 24
Enables or disables the continuously keyed mode. Note: Remotes cannot receive when keyed.
DATAKEY [ON, OFF]
Details page 24
Toggles between key-on-data and key-on-RTS.
DKEY
Details page 25
Dekey the radio (transmitter OFF). This is generally a radio test command.
DLINK [ON/OFF/xxxx]
Details page 25
Configures local diagnostic link protocol.
DMGAP [xx]
Details page 25
(Diagnostics) Sets the amount of time to wait after the receipt of a character before interpreting the next received character as the start of a new message.
MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 21
DTYPE [NODE/ROOT]
Details page 25
(Diagnostics) Sets up a radio as a Root or Node radio. Associated commands are GATE and PEER. (See MDS’ Network-Wide Diagnostics System Handbook (MDS P/N 05-3467A01) for details.)
DUMP
Details page 26
Display all programmable settings.
HREV
Details page 26
Display the Hardware Revision level, if programmed.
INIT
Details page 26
Set radio parameters to factory defaults.
INIT [2710]
Details page 26
Restores certain transceiver defaults before using the INIT xx20 command.
INIT [2720]
Details page 26
Configure radio for use with an MDS model P-20 chassis.
KEY
Details page 27
Key the radio (transmitter ON). This is generally used for radio testing.
MODEL
Details page 27
Display the model number of the radio.
MODEM [xxxx, NONE]
Details page 27
Set the modem characteristics of the radio.
OWM [XXX...]
Details page 27
Set or display the owner’s message.
OWN [XXX...]
Details page 27
Set or display the owner’s name.
PTT [0–255]
Details page 27
Set or display the Push-to-Talk delay in milliseconds.
PWR [20–37]
Details page 27
Set or display the transmit power setting.
RSSI
Details page 28
Display the Received Signal Strength Indication.
RTU [ON/OFF/0-80]
Details page 28
Enables or disables the radio’s internal RTU simulator and sets the RTU address.
RX [xxx.xxxxx]
Details page 28
Set or display receiver frequency.
RXTOT [NONE, 1-255]
Details page 28
Set or display the value of the receive time-out timer.
SCD [0-255]
Details page 28
Set or display the Soft-carrier Dekey delay in milliseconds.
SER
Details page 28
Display the radio serial number.
SHOW [DC, PORT, PWR]
Details page 29
Display the DC voltages, diagnostics port, and transmit power level.
SREV
Details page 29
Display the Software Revision Level.
STAT
Details page 29
Display radio status and alarms.
Table 7. Command summary (Continued)
Command name Function