Microtest SimpliFiber 850/1300 Source, SimpliFiber 1310 Source, SimpliFiber Meter User Manual

Page 1
SimpliFiber ENGLISH - 1
SimpliFiber
TM
USER GUIDE
ENGLISH
A Guide to using the Microtest SimpliFiberTM to install, manage, and troubleshoot single-mode and multimode fiber cabling systems.
SimpliFiber
TM
accurately measures power loss of
single-mode and multimode fiber optic cabling. It features automatic wavelength detection,
storage of test results, and PC database support in an easy-to-use low cost design.
C
OPYRIGHT
© 1999 M
ICROTEST
, INC. ALL
RIGHTS RESERVED
Page 2
SimpliFiber ENGLISH - 2
Contents
Chapter 1 - Introduction............... 5
The Simple Fiber Solution....................................5
The SimpliFiber Kit...............................................6
The SimpliFiber Accessory Kits ...........................7
SimpliFiber Meter .............................................8
SimpliFiber 850/1300 Source...........................9
SimpliFiber 1310 Source................................10
SimpliFiber Meter ............................................... 11
Using the Keypad...........................................11
Reading the Display .......................................12
SimpliFiber Source.............................................14
Using the Keypad...........................................14
LED Indicators................................................15
Calibration ..........................................................16
Technical Support ..............................................16
Product Versions................................................18
Chapter 2 - Measuring Loss...... 19
The Reference Value .........................................19
The Reference Methods.....................................20
Method A ........................................................21
Measuring Loss using Method A....................22
Method B ........................................................23
Measuring Loss using Method B....................24
Method C........................................................25
Measuring Loss using Method C ...................27
Page 3
SimpliFiber ENGLISH - 3
Saving Results ...................................................28
Viewing Results..................................................29
Deleting Results .................................................29
Uploading to a PC ..............................................30
Chapter 3 - Measuring Power ... 31
Measuring Power ...............................................31
Appendix A - Technical Specifica-
tions........................................... 33
SimpliFiber Meter ...............................................33
SimpliFiber Source.............................................35
Accessories........................................................36
Appendix B - Error Messages ... 37
Err 1 - Invalid Reference value...........................37
Err 2 - UNDER or OVER limit.............................37
Err 3 - Memory is full, cannot save result...........37
Err 4 - No results are stored in memory. ............38
Err 5 - Wavelength cannot be changed. ............38
Err 6 - Calibration is expired...............................38
Err 7 - Communication error between SimpliFiber
Meter and PC. ....................................................38
Err 8 - Connection error between SimpliFiber and
PC ......................................................................39
Page 4
SimpliFiber ENGLISH - 4
Page 5
SimpliFiber ENGLISH - 5
Chapter 1 - Introduction
The Simple Fiber Solution
Welcome to the Microtest family of fiber optic installation, test and diagnostic products.
SimpliFiber is a high quality fiber optic cabling test tool for easy and rapid identification of failure points in a fiber network. It consists of two units:
SimpliFiber Meter and SimpliFiber Source. SimpliFiber Meter, the optical power meter , and
SimpliFiber Source, the optical light source,
address the challenges of installing, managing, and troubleshooting multimode and single-mode fiber cabling systems.
The SimpliFiber850/1300 Source provides a consistent dual wavelength light that allows you to quickly and accurately assess the perfor­mance of fiber optic transmission paths and equipment. It also supplies a modulated signal for use with fiber identifiers.
The SimpliFiber Meter measures the power of light emerging from the fiber . By measuring optical power , SimpliFiber Meter verifies the proper installation and operations of fiber optic
Page 6
SimpliFiber ENGLISH - 6
components, such as fiber optic hub modules, repeaters, and adapter cards.
SimpliFiber also helps to identify faulty patch cables, failing splices, or bad couplers and connectors by measuring signal loss.
The SimpliFiber Meter can be used with any source operating at 850, 1300, 1310, or 1550.
The SimpliFiber 850/1300 or 1310 Source can be used with any power meter .
A hinged cover protects the units connector(s). It also allows the units to be propped up during use.
The SimpliFiber Kit
Microtest’s SimpliFiber kit contains the SimpliFiber Meter and SimpliFiber 850/1300 Source units. The kit includes the optical cleaning supplies that are needed to keep fiber connectors and adapt­ers free from contamination.
The Microtest SimpliFiber kit contains:
SimpliFiber Meter
SimpliFiber 850/1300 Source
• A soft carrying case
• Four AA alkaline batteries (two for each unit)
• Fiber cleaning supplies
• ScanLink Software
Page 7
SimpliFiber ENGLISH - 7
• A communication cable to connect to the PC
• Registration Card and User Guide
The SimpliFiber Accessory Kits
Microtest’s SimpliFiber Meter allows you to use different light sources.
SimpliFiber 1310 Source, an additional source kit for the verification of single-mode fiber at 1310nm is sold separately .
SimpliFiber 1310 Source is an active laser source that work with SimpliFiber Meter to verify optical cable transmission quality .
SimpliFiber Meter will recognize all SimpliFiber Sources and set the appropriate wavelength.
Page 8
SimpliFiber ENGLISH - 8
SimpliFiber ST or SC optical receiver port
Powers SimpliFiber ON or OFF. SHFT in conjunction with other keys executes
extended functions. REF sets the Reference.
λ increases the wavelength from 850nm to 1300nm to 1310nm to 1550nm. SHFT + dBm switches the mode between dBm and dB.
SAVE saves test results. SHFT + DEL deletes results.
DB-9 Serial Connector allows attachment of a serial cable for interface with PC-based software (ScanLink).
SimpliFiber Meter
Page 9
SimpliFiber ENGLISH - 9
Powers SimpliFiber Source ON or OFF.
AUTO senses the wavelength currently used by SimpliFiber.
MOD allows you to toggle between continuous and modulated lightsource
λ turns on the 850nm or 1300nm output when cable is moved from one port to the other.
SimpliFiber 850/1300 Source
850 nm ST or SC connector port
1300 nm ST or SC connector port
Page 10
SimpliFiber ENGLISH - 10
Powers SimpliFiber Source ON or OFF.
AUTO senses the wavelength currently used by SimpliFiber.
MOD allows you to toggle between continuous and modulated lightsource
SimpliFiber 1310 Source
1310 nm ST or SC connector port
Page 11
SimpliFiber ENGLISH - 11
SimpliFiber Meter
The SimpliFiber Meter interface consists of an LCD display and a keypad.
Using the Keypad
Use the SimpliFiber Meter keypad to select the functions necessary to test and troubleshoot fiber optic cabling. Each key performs at least two functions. When multiple keys are required to activate a function, press and hold each key in the order shown below .
When turned on, SimpliFiber Meter will flash the LCD power up test and then resume the test mode that was last executed. To con­serve battery life SimpliFiber Meter will turn off automatically when no signal is detected and no key has been used for 60 minutes.
Press this button to shift to the upper key functions dB/m and DEL). When activated the word SHFT is displayed.
Press and hold this button to set the Reference. Press this button until SHFT is displayed, press it
again to display the reference value.
Press this button to change the wavelength (
λλ
λλ
λ). The sequence is: 850nm, 1300nm, 1310nm,
and 1550nm. Use this function only when
Page 12
SimpliFiber ENGLISH - 12
connecting to a lightsource other than SimpliFiber
Source. When using SimpliFiber 850/1300 or 1310 Sources in AUTO mode, the wavelength
will be detected automatically .
+ Use these buttons to change the mode between Power Meter (dBm) and Loss
Meter (dB).
Press this button to display the next available position where a test can be saved.
Press and hold this button to SAVE test results.
Press and then press and hold to DELETE the last saved test result.
Press and then press to VIEW the last saved test result.
Reading the Display
The display is operational when all LCD icons appear as shown below .
Page 13
SimpliFiber ENGLISH - 13
If no icons appear when the unit is in operation, check the batteries for correct installation or install new batteries.
Measure at 850nm wavelength Measure at 1300nm wavelength Measure at 1310nm wavelength Measure at 1550nm wavelength Align units, set Reference Send SimpliFiber in for Calibration
Low Battery power Error occurred
Successful operation Negative value Loss measurement value displayed Power measurement value displayed Current reference value being stored
Result or Error message
Page 14
SimpliFiber ENGLISH - 14
SimpliFiber
Source
The SimpliFiber Source is an active and intelli- gent light source that works with SimpliFiber Meter to verify optical cable transmission quality.
The SimpliFiber 850/1300 is an LED light source. The SimpliFiber 1310 Source is a laser light
source.
WARNING: When using SimpliFiber 1310 Source, vis-
ible and/or invisible laser radiation could be present.
Avoid direct exposure to the beam.
Using the Keypad
When turned on the SimpliFiber Source will light the LED of the last active transmission mode.
Press AUTO and SimpliFiber Meter will automatically sense the current SimpliFiber
Source wavelength. When using SimpliFiber Meter and SimpliFiber Source, AUTO mode
should always be selected, so that SimpliFiber Meter can automatically determine the
λλ
λλ
λ of the
Page 15
SimpliFiber ENGLISH - 15
transmitted light.
The transmitted light can be operated continuously or modulated. When measuring
power , use the continuous light source. When identifying fiber cables with an identifier , use the 2kHz modulated mode.
Press MOD to toggle between continuous and modulated lightsource. When Continuous Wave is selected, the LED will show a steady light; when 2kHz (modulated) is selected, the LED will blink.
Use this feature with all third party power meters.
(SimpliFiber 850/1300 Source) Press
λλ
λλ
λ
(Lambda) to manually switch the wavelength between 850 nm and 1300 nm. Connect the launch cable to the appropriate port.
LED Indicators
SimpliFiber
850/1300 Source has 5 red LED indicators. The following describes the LED activity:
LED Name Description
850nm transmitting at 850nm wavelength 1300nm transmitting at 1300nm wavelength AUTO SimpliFiber Meter is auto-sensing the
wavelength of SimpliFiber Source
Page 16
SimpliFiber ENGLISH - 16
CW/2kHz Steady for continuous light source;
flashing for modulated light source,
Low Batt Time to replace AA batteries
SimpliFiber
1310 Source has 4 red LED indica­tors. The following describes the LED activity:
LED Name Description
1310nm transmitting at 1310nm wavelength AUTO SimpliFiber Meter is auto-sensing the
wavelength of SimpliFiber Source
CW/2kHz Steady for continuous light source;
flashing for modulated light source,
Low Batt Time to replace AA batteries
Calibration
The SimpliFiber Meter should be calibrated annually with specialized Microtest equipment. Contact Microtest Technical Support for informa­tion on calibration and service requirements.
Technical Support
Note: All connectors and fiber end faces need to be clean prior to testing. Use the appropriate optical cleaning supplies to keep connectors and couplers free from contamination.
Page 17
SimpliFiber ENGLISH - 17
If you have technical questions, you may contact Microtest Technical Support by phone, fax, or e­mail.
Note: Before calling Technical Support, please have your product version number available.
Americas and Asia Pacific:
1-800-NET-FIXR (1-800-638-3497) (U.S. and Canada only) 1-800-419-8991 (FAX) (U.S. and Canada only)
1-602-952-6494 (FAX)
support@microtest.com (E-mail) www .microtest.com/support (W eb Support)
If the 1-800 service is not available, please contact your local authorized Microtest reseller.
Greater Europe, Middle East, and Africa:
+44 1 293 89 40 25 (V oice), +44 1 293 89 40 08 (F AX)
supportmte@microtest.com (E-mail)
For new product information:
World Wide Web: http://www.microtest.com sales@microtest.com (E-mail for U.S.) salesmte@microtest.com (E-mail for Europe)
For the latest cable installation, international standards, and conformance techniques:
World Wide Web page at http:// www.cabletesting.com
Page 18
SimpliFiber ENGLISH - 18
Product Versions
To display the Product Version, turn SimpliFiber Meter off.
Hold the key down while pressing the key.
Release both keys. The Product V ersion will be displayed as shown
below.
WARNING: DURING OPERATION, TEST­ING, OR MAINTENANCE OF A FIBER OP­TIC SYSTEM, NEVER LOOK INTO AN AC­TIVE FIBER OPTIC CABLE. INFRARED RADIA TION MA Y BE PRESENT AND PER­MANENT EYE DAMAGE CAN RESUL T.
Page 19
SimpliFiber ENGLISH - 19
Chapter 2 - Measuring Loss
Loss measures the signal degradation in a fiber optic cable. SimpliFiber 850/1300 Source injects a signal into the fiber cable and SimpliFiber Meter measures the received signal at 850nm or 1300nm.
Described in this chapter are the procedures for measuring loss in a fiber optic cable plant using SimpliFiber Meter and SimpliFiber Source.
Three different test methods are explained; they vary in the way the launch cables are connected when the reference value is determined.
The Reference Value
Accurate repeatable measurements of optical power and signal loss are fundamental for the installation and maintenance of fiber optic cabling.
To make an accurate measurement, you need to know the loss of your attached launch cable and the power being transmitted.
Page 20
SimpliFiber ENGLISH - 20
The reference value must be stored before a loss measurement can be calculated. SimpliFiber requires the reference value to compensate for the signal loss in the launch cable. This value is then automatically subtracted from the actual measured value to determine cable plant loss.
Note: The launch cable used to set the refer­ence value should be the same type as the cables to be tested: 50/125, 62.5/125, or single­mode
.
IMPORTANT All connectors and fiber end faces should
be cleaned prior to testing.
The Reference Methods
There are three recognized methods for refer­ence determination. Reference diagrams will show how to establish a reference for each method.
It is very important that the connections are not disturbed after the reference value is estab­lished. To assure that the effects of the connec­tors and launch cables are “zeroed out”, follow the instructions closely.
Note: When a connector is removed and then reattached, it is unlikely to go back into the exact same position. As a result, measurements will change slightly when connec­tions are made or broken.
Page 21
SimpliFiber ENGLISH - 21
METHOD A
For Method A two launch cables are used to set the reference.
Method A cancels the effects of the launch cables and one coupler for all subsequent measurements.
1. Connect a Launch Cable to SimpliFiber Meter.
2. Connect a Launch Cable to SimpliFiber Source.
3. Use a coupler to connect the two fiber ends.
4. Power on SimpliFiber Source
and press . To choose the appropriate wavelength, 850 or 1300 depending on where the
fiber is connected, press
.
5. Power on SimpliFiber Meter. The unit will auto-sense the appropriate wavelength.
Note: When using a light source other than
SimpliFiber
Source, press the to select the appropriate wave­length. Both units must be set to the same wavelength.
6. Press, hold and release the
2m Launch Cable
Coupler
2m Launch Cable
SimpliFiber
Source
METHOD A
SimpliFiber
Meter
Page 22
SimpliFiber ENGLISH - 22
button to set
and save the new reference value. The reference value will be displayed.
7. Disconnect the coupler without disturbing the fiber connections to the units.
Measuring Loss using Method A
When Method A was used to set the reference, proceed as follows:
1. Do not disconnect the launch cables from the SimpliFiber units.
2. Disconnect one launch cable from the coupler .
3. Connect the fiber to be measured between the launch cables. An extra coupler is needed.
4. SimpliFiber Meter will report the loss in dB.
5. Press and hold to
2m Launch Cable
2m Launch Cable
SimpliFiber
Source
METHOD A
Cable Under Test
SimpliFiber
Meter
Page 23
SimpliFiber ENGLISH - 23
save the test result. When using
Method A, the effects of both launch cables and one coupler are removed.
METHOD B
This method is commonly recommended by ISO 11801 and ANSI/EIA/TIA 568A.
For Method B, one launch cable is used to set the reference.
The launch cable will be canceled out for all subse­quent measurements.
1. Connect one end of a Launch Cable to SimpliFiber
Meter.
2. Connect the other end of the same Launch Cable to SimpliFiber Source.
3. Power on SimpliFiber
Source and press . To choose the appropriate wavelength, 850 or 1300,
2m Launch Cable
SimpliFiber
Source
METHOD B
SimpliFiber
Meter
Page 24
SimpliFiber ENGLISH - 24
press
.
4. Power on SimpliFiber Meter. The unit will auto- sense the appropriate wavelength.
Note: When using a light source other than
SimpliFiber
Source, press the to select the appropriate wavelength. Both units must be set to the same wavelength.
5. Press, hold and release the button to set and save the new
reference value. The reference
value will be displayed.
6. Disconnect the Launch Cable from the
SimpliFiber Meter.
Measuring Loss using Method B
When Method B was used to set the reference, proceed as follows:
1. Do not disconnect the launch cable from the SimpliFiber Source unit.
2. Connect the fiber to be measured between the SimpliFiber Meter output and the launch cable that is attached to SimpliFiber Source. An extra
Page 25
SimpliFiber ENGLISH - 25
coupler is needed.
3. SimpliFiber Meter will immediately report the loss in dB.
4. Press and hold to save the test result.
Method B removes the effect of one launch cable.
METHOD C
For Method C three launch cables and two connectors are used to set the reference. All of the launch cables and connectors are canceled. Use this method when measuring an end to end system where the patch cables need to be included in the total loss measurement.
1. Connect the first Launch Cable to SimpliFiber Meter.
2. Connect the second Launch Cable to Simpli-
2m Launch Cable
SimpliFiber
Source
METHOD B
Cable Under Test
SimpliFiber
Meter
Page 26
SimpliFiber ENGLISH - 26
Fiber Source.
3. Use two couplers to join the two launch cables with a third launch cable.
4. Power on SimpliFiber Source
and press .
5. Choose the appropriate wavelength, 850 or 1300, press
Note: When using a light source other than SimpliFiber Source,
press the to select the appropriate wavelength. Both units must be set to the same wavelength.
6. Press, hold and release the
button to set and save the
new reference value. The reference value will be displayed.
7. Disconnect the third Launch Cable, located in the center , without disturbing any connections to the couplers or adapters.
METHOD C
2m Launch Cable
Couplers
Launch Cable 2m Launch Cable
SimpliFiber
Source
SimpliFiber
Meter
Page 27
SimpliFiber ENGLISH - 27
Measuring Loss using Method C
When Method C was used to set the reference, proceed as follows:
1. Do not disconnect the launch cables from the SimpliFiber units.
2. Remove the launch cable located in the center without disturbing the couplers.
3. Connect the fiber to be measured between the launch cables.
4. SimpliFiber Meter will immediately report the loss in dB.
5. Press and hold to save the test result.
Method C removes the effect of the launch cables and the couplers.
2m Launch Cable 2m Launch Cable
SimpliFiber
Source
METHOD C
Cable Under Test
SimpliFiber
Meter
Page 28
SimpliFiber ENGLISH - 28
Saving Results
SimpliFiber Meter will store 100 test results. Each test is stored in order , e.g. 5 is the fifth test that was stored.
1. To save a test result press . A number (between 1 and 100) will flash in the lower right corner of the display .
In our example 5 is the next open storage position.
2. Press and hold the button until OK is displayed in the lower left corner of the display.
The number of the saved test will be displayed to confirm that the result was saved.
In our example test result number 5 has been saved.
Page 29
SimpliFiber ENGLISH - 29
Viewing Results
1. Press and then to display the last stored test.
A number (between 1 and 100) and the test result start flashing alternately .
Deleting Results
1. Press and then hold to delete the result.
OK and the number of the deleted test will be displayed to confirm that number 4 is available again.
Note: The most recent test will be deleted first.
Page 30
SimpliFiber ENGLISH - 30
Uploading to a PC
Test results can be uploaded to a PC using the included ScanLink software from Microtest.
1. Connect the SimpliFiber Meter serial port to the serial port on your PC with the supplied communications cable.
2. Power on SimpliFiber Meter.
3. Run the
ScanLink
software.
4. Click on (Upload) to establish commu­nications between ScanLink and SimpliFiber Meter.
5. From ScanLink’s Upload screen select SimpliFiber.
6. Select the Communications Port: Com 1 or Com 2.
7. Click Upload. Test results that are stored in SimpliFiber Meter’s
memory will be uploaded to the PC. Consult the ScanLink on-line help for further
instructions for viewing, saving, and printing test results.
8. Power the SimpliFiber Meter off when the transfer is completed.
Page 31
SimpliFiber ENGLISH - 31
Chapter 3 - Measuring Power
Measuring Power
When measuring power , the overall power is reported. Use it to quickly verify cabling and equipment problems.
1. To measure power, connect the fiber optic cable to the appropriate SimpliFiber 850/1300 Source output.
2. Connect the fiber optic cable to the SimpliFiber Meter.
3. Power on SimpliFiber Source and press .
4. To choose the appropriate wavelength, press
5. Power on SimpliFiber Meter. The unit will auto­sense the wavelength.
Note:
When using a source other than Simpli-
Fiber Source, press to select the wave-
Page 32
SimpliFiber ENGLISH - 32
length.
6. Press and then the button to change the units from dB to dBm.
7. SimpliFiber Meter will immediately report the overall power in dBm.
Page 33
SimpliFiber ENGLISH - 33
Appendix A - Technical Specifications
SimpliFiber Meter
Physical Characteristics
• Dimensions: 13.97 cm x 8.25 cm x 2.54 cm (6.25" x 3.50" x 1.25")
• Weight: 171.54 g (.38 lbs)
Power Source
• 2 AA Alkaline batteries
• Battery Life: Varies depending on usage and battery quality . On average, the batteries will last 100 hours.
User Interface
Display:Custom LCD Size: 4.42 cm x 2.15 cm (1.75" x .85") Keypad: Four momentary contact keys
Page 34
SimpliFiber ENGLISH - 34
Environmental
• Operating Temperature: 0° to 45°C (32° to 113°F)
• Storage Temperature:
-20° to 60°C (14° to 140°F)
• Humidity: 10% to 90% non-condensing
• Storage Humidity: 5 to 95%
Serial Port
• RS-232, DB 9
Memory
• Test Storage: 100 complete test results can be stored in nonvolatile flash memory
Test Functions
Optical Measurements
• Dynamic Range: +3dBm to -55dBm
• Resolution: 0.01dB
• T ypical accuracy (at -20dBm): ±0.25dB
Page 35
SimpliFiber ENGLISH - 35
SimpliFiberSource
Physical Characteristics
• Dimensions: 13.97 cm x 8.25 cm x 2.54 cm (6.25" x 3.50" x 1.25")
• Weight: 171.54 g (.38 lbs)
Power Source
• 2 AA Alkaline batteries
• Battery Life: Varies depending on usage and battery quality .
850/1300 Source: On average, the batteries will last 10-50 hours, depending on Mode
1310 Source: On average, the batteries will last 20-100 hours, depending on Mode
Wavelength
• 850, LED, > -20dBm
•1300, LED, > -20dBm
• 1310, Laser , ±20nm, > -10dBm
Environmental
• Operating Temperature: 0° to 45°C (32° to 113°F)
• Storage Temperature:
-20° to 60°C (14° to 140°F)
• Humidity: 10% to 90% non-condensing
Page 36
SimpliFiber ENGLISH - 36
• Storage Humidity: 5 to 95%
Governmental Certifications
• CE
Accessories
SimpliFiber Source 1310 ST, Model 8251-01 SimpliFiber Source 1310 SC, Model 8251-11
Fiber Optic Cable Kit ST - SC
62.5/125 Model 8252-01 50/125 Model 8252-03 Single Model 8252-05
Fiber Optic Cable Kit ST - ST
62.5/125 Model 8252-02 50/125 Model 8252-04 Single Model 8252-06
Page 37
SimpliFiber ENGLISH - 37
Appendix B - Error Mes­sages
Err 1 - Invalid Reference value.
Error code 1 indicates that the reference value is ‘under’ or ‘over’ the limits.
- Store a new Reference value.
Err 2 - UNDER or OVER limit.
The measured value is under or over the limit. The numeric values displayed on the LCD can range from -55.00 dB/dBm to 3.00 dB/dBm.
When a measurement is less than -55.00 dB/ dBm, the measured value is UNDER the limit.
When a measurement is more than 3.00 dB/ dBm, the measured value is OVER the limit.
- Remeasure
Err 3 - Memory is full, cannot save result.
Error code 3 indicates that the unit’s memory is full.
Page 38
SimpliFiber ENGLISH - 38
- Upload the stored test results to your PC.
- Delete saved results from the unit’s memory.
Err 4 - No results are stored in memory.
Error code 4 indicates that there are no results stored in the units memory.
- SimpliFiber’s memory is empty .
Err 5 - Wavelength cannot be changed.
Error code 5 indicates that the wavelength cannot be changed while the SimpliFiber Source unit is in AUTO mode.
- Change mode to CW prior to changing the wavelength
Err 6 - Calibration is expired.
Calibration values are corrupted
- Send unit in for calibration
Err 7 - Communication error between SimpliFiber Meter and PC.
Communication between PC and SimpliFiber cannot be established.
- Verify connection between SimpliFiber and the PC and retry.
Page 39
SimpliFiber ENGLISH - 39
Err 8 - Connection error between Simpli­Fiber and PC
Connection between SimpliFiber and PC is broken.
-
Verify connection between SimpliFiber and the
PC and retry.
Page 40
SimpliFiber ENGLISH - 40
Loading...