Congratulations on your purchase of the ArtixScan 6000XY scanner. The 42-bit highresolution ArtixScan 6000XY is specifically for graphic arts and imaging professionals.
This manual will help you in the installation and operation of your scanner.
Scanning AreaReflectiv e: 12” x 17” (305 mm x 432 mm)
Scanning Productivity15 scans per hour (6 cm x 7 cm, 250%, 300dpi, CMYK)
Interf a c eSCSI-2
Lamp SourceCold Cathode Lamp
TemperatureOperating: 61 - 80°F (16 - 27°C)
Humidity10% - 85%
Dimensions14” x 34” x 27.5” (36 mm x 87 mm x 70 m
Net W eight147 lb (67 kg)
Pow er ConsumptionOperation: 290 W
C e r tificationsCSA, T U V, FCC class B , CF
Transparency: 12” x 17” (305 mm x 432 mm)
Stor age: -10 - 55°F
Standby: 200W
ArtixScan 6000XY Installation and Operation Manual 1
2Site Power and Working Space
This section describes the working conditions and working space for operating the
ArtixScan 6000XY .
General Requirements
Before unpacking your scanner, make sure that the site where the scanner will be
installed is big enough to allow for easier operation.
• Make sure that the operating environment for the scanner is free of dust and other
contaminants.
• Allow adequate ventilation space (no less than 10 inches) around the scanner .
• Place the scanner on a flat, stable surface that is not subject to vibration.
• Make sure that the scanning surface will not be exposed to direct sunlight or other
sources of bright light.
• A void placing the scanner close to sour ces of extreme temperature.
• A void connecting the scanner to a power sour ce that might experience power
surges.
• A void positioning the scanner in the path of heavy traffic wher e it may get bumped.
Once the scanner has been placed in a suitable location and is ready to be connected
to the host computer, it is time to pr oceed to installing the necessary har dwar e and
software components for the scanner .
SCSI cables
Your scanner should be placed within 3 feet of the computer. Use the SCSI cable that
came with your scanner.
Minimum Macintosh requirements
• Apple Power Mac with PCI bus (150 MHz)
• Apple Macintosh system software version 8.5 or higher
• CD-ROM drive
• 64MB of available RAM
• 1 GB hard disk space
• Color monitor at least 17” with 24-bit color display ability
Safety Instructions
To prevent the electric shock, the cover should only be removed by a qualified service
engineer.
2 ArtixScan 6000XY Installation and Operation Manual
This warning icon appears inside the scanner which indicates that the scanner lamps
are hot, you should wait for several minutes for them to cool off.
Scanner front and back view
A. Front view of the scanner
TMA Carriage Lock
Top Cover (TMA)
Scan Bed
Scanner Carriage Lock
Status LED Indicator
Light Button
B. Back view of the scanner
D C P ow er Input P ort
6
Ter minator Switch
TMA Connector
ArtixScan 6000XY Installation and Operation Manual 3
SCSI ID Switch
25-pin SCSI Port
50-pin SCSI Port
Unlocking scanner carriage
Unlocking TMA carriage
Tur n the scre w
countercloc kwise to
unlock the scanner
carr iage .
UNLOCK
LOCK
4 ArtixScan 6000XY Installation and Operation Manual
Tur n the screw
countercloc kwise to unlock
the TMA carr iage .
3Powering Up
This section describes the power up sequence for the ArtixScan 6000XY.
Power cable
The power cable shown below is a North American type that complies with United
States and Canadian requirements. Power cables used in other areas may have a
different look.
Voltage
The ArtixScan 6000XY scanner is preset to the voltage in your country. There is no
need to manually select the voltage; however , make sur e that the label next to the
power entry module indicates the correct voltage. Contact your dealer if the label
indicates an incorrect voltage.
Power cord connection
Caution! Make sure your scanner carriage is unlocked prior to connecting it to a
power source.
1. The scanner should be switched to the “OFF” position.
Switch the scanner’s po w er to
the “Off ” position.
2. At the scanner back panel, connect the power cord.
3. Connect the other end of the power cord to a grounded power source.
ArtixScan 6000XY Installation and Operation Manual 5
4. Switch the scanner’ s power to the “On” position.
Switch the scanner’s
po w er to the “On”
position.
Power up self-test
The following sequence of events should take place after powering up the scanner:
• The scanner performs a self-test by homing the carriages and camera box. Through
the platen glass, you can observe the carriage moving, and you will hear a series of
clicking noises associated with the operation of the scanner motors. These “clicking” noises are normal. However , if you hear loud grinding noises or any other
abnormal sound, turn the scanner off immediately and contact your dealer .
• The Status lamp turns red for a few seconds when the scanner power is turned on.
• The Status lamp goes off when the scanner checks the power supply.
• The Status lamp turns green for about 30 seconds while the scanner performs selftest. If this step is completed successfully, the lamp r emains on green.
If an error occurs and the scanner is not able to start properly, the status indicators
will display a steady red light. If this happens, turn off the scanner and contact your
dealer.
6 ArtixScan 6000XY Installation and Operation Manual
4Connecting your scanner
This section provides information on installing the ArtixScan 6000XY on the
Macintosh. The procedures are divided into two main sections: 1) Installation for
Macintosh computers that feature built-in SCSI ports; and 2) Installation for the new
Macintosh G3/G4 computers with built-in USB ports. For the new G3/G4 computers,
you will be installing the SCSI interface card included in the scanner package.
Important: Before connecting, make sure that the computer, your scanner, and all other
devices are turned off.
Installation for Macintosh computers with built-in
SCSI ports
A. Connecting the scanner
1. Shut down your computer.
2. Connect the scanner to your computer, using the SCSI cable pr ovided in the
scanner package.
Note: See the next section for details on termination
Connect the SCSI
c able to the
Macintosh SCSI
por t.
(1)
6
SCSI
ID
OFF
ON
TERMINATION
3. Plug the power cord to the power connector at the back panel of the scanner, and
plug the other end of the power cord to your AC power source or wall outlet.
4. Turn on your scanner and wait for all the lights on the front panel to stop blinking
and stay on steady.
5. Power up your Macintosh.
ArtixScan 6000XY Installation and Operation Manual 7
B. Termination
1. If the scanner is the last device on the SCSI chain, set the internal terminator switch
on the back of the scanner to the “ON” position. There is no need to install an
external terminator on any of the other SCSI devices on the chain.
(1)
OFF
6
SCSI
ID
ON
TERMINATION
2. If the scanner is not the last device on the SCSI chain:
• Make sure the internal terminator switch located at the back of the scanner is set
to the “OFF” position.
• Make sure the last device on the SCSI chain is terminated.
If the scanner is the last
device, set the ter minator
switch to the “On” position.
Installation for the new G3/G4 Macintosh computers
(without built-in SCSI ports)
A. Installing the interface card
Before installing the interface card, make sur e you turn off your computer and
peripherals. Then follow the steps below:
8 ArtixScan 6000XY Installation and Operation Manual
1. Shut down your computer and unplug the power cord. Next, open your computer .
2. Look for an available PCI card slot (typically white or ivory) in your computer .
Remove the slot cover, and inser t the PCI SCSI car d into the slot. Push the car d in
to make sure it is seated all the way in the slot. This is important, as an improper
card connection will make you unable to use your scanner , and you will then have
to remove the computer case and reinsert the card.
SCSI Card
Inser t the SCSI card to the PCI
SCSI card into the slot.
3. Close the computer.
B. Connecting the scanner
1. Shut down your computer.
2. Connect the scanner to your computer, using the SCSI cable pr ovided in the
scanner package.
Note: See the next section for details on termination.
Connect the SCSI cable
to the Macintosh.
(1)
6
SCSI
ID
OFF
ON
TERMINATION
3. Plug the power cord to the power connector at the back panel of the scanner, and
plug the other end of the power cord to your AC power source or wall outlet.
4. Turn on your scanner and wait for the lights on the front panel to stop blinking and
ArtixScan 6000XY Installation and Operation Manual 9